Hojat Ebrahiminik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hojat Ebrahiminik has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Seyed Mohammad Tavangar
Department of Pathology, Dr. Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran
4 shared publicationsHossein Chegeni
3 shared publications- Hossein Chegini
Tirad Imaging Institute, Tehran, Iran
3 shared publications - Mahboobeh Hemmatabadi
Department of Endocrinology, Endocrinology, and Metabolism Research Center, Vali-Asr Hospital, Imam Khomeini Complex Hospital, Tehran University of Medical Sciences, Tehran, Iran
3 shared publications Mahdieh Taghvaei
Endocrinology and Metabolism Research Center (EMRC), Vali-Asr Hospital, Tehran University of Medical Sciences, Tehran, Iran
3 shared publicationsMaryam Pourashraf
Tirad Imaging Institute, Tehran, Iran
3 shared publications
Latest Publications
- 2 July 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (9) , 5170-5171
Reply to the Letter to the Editor: AI-driven thyroid malignancy prediction
- 2 July 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (9) , 5170-5171
Reply to the Letter to the Editor: AI-driven thyroid malignancy prediction
- Open Access
- 14 April 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (10) , 6624-6625
Correction: Prediction of thyroid malignancy risk using clinical and ultrasonography features and a machine learning approach
- 14 April 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (10) , 6624-6625
Open AccessCorrection: Prediction of thyroid malignancy risk using clinical and ultrasonography features and a machine learning approach
- 14 February 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (9) , 5157-5167
Prediction of thyroid malignancy risk using clinical and ultrasonography features and a machine learning approach
This study aims to develop and validate a predictive model for thyroid nodule malignancy risks using clinical and ultrasonography features and a machine learning (ML) approach. This retrospective study is based on the clinical and ultrasound characteristics of 1035 thyroid nodules (845 benign and 190 malignant) to develop and validate the risk prediction model. Employing multiple logistic regression, key features were selected in developing the model. Eight ML algorithms were evaluated for predicting the risks of malignancy. Finally, the predictive ability of the best-performing algorithm was compared against American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) and American Thyroid Association (ATA) guidelines. Based on AUC criteria (88.3, 95% CI: 81.2-94.2), sensitivity (84.2, 95% CI: 71.1-94.7), specificity (92.3, 95% CI: 88.2-95.9), positive predictive value, (71.4, 95% CI: 60.4-83.3) and negative predictive value (96.3, 95% CI: 93.5-98.8), the XGBoost algorithm exhibited superior performance over the other ML algorithms and ACR TI-RADS and ATA. These criteria were obtained for ACR TI-RADS at 54.2%, 63.2%, 48.5%, 21.1%, and 84.8%, while for ATA, they were 44.3%, 76.3%, 27.2%, 18.4%, and 81.6%. In addition, the unnecessary fine-needle aspiration (FNA) rate with ACR TI-RADS and ATA was 43% and 63%, respectively-significantly higher than the 7% obtained with XGBoost. This study demonstrated the capability of ML approaches in enhancing the accuracy of predicting thyroid malignancy risks as well as their potential benefits in optimizing healthcare resources by reducing unnecessary FNA rates. Using the proposed model through a web-based tool can facilitate clinical judgments in thyroid nodule management and personalized treatment. Question Current risk assessment systems have limitations, with high unnecessary FNA rates compared to machine learning (ML) models. Findings The XGBoost algorithm was compared to other ML algorithms, ACR TI-RADS, and ATA and demonstrated superior performance. Clinical relevance This study demonstrated the capability of ML approaches in enhancing the accuracy of predicting thyroid malignancy. The proposed web-based tool to facilitate the prediction of thyroid nodule risk is available at https://aimedlab.ir/tnr .
- 14 February 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (9) , 5157-5167
Prediction of thyroid malignancy risk using clinical and ultrasonography features and a machine learning approach
This study aims to develop and validate a predictive model for thyroid nodule malignancy risks using clinical and ultrasonography features and a machine learning (ML) approach. This retrospective study is based on the clinical and ultrasound characteristics of 1035 thyroid nodules (845 benign and 190 malignant) to develop and validate the risk prediction model. Employing multiple logistic regression, key features were selected in developing the model. Eight ML algorithms were evaluated for predicting the risks of malignancy. Finally, the predictive ability of the best-performing algorithm was compared against American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) and American Thyroid Association (ATA) guidelines. Based on AUC criteria (88.3, 95% CI: 81.2-94.2), sensitivity (84.2, 95% CI: 71.1-94.7), specificity (92.3, 95% CI: 88.2-95.9), positive predictive value, (71.4, 95% CI: 60.4-83.3) and negative predictive value (96.3, 95% CI: 93.5-98.8), the XGBoost algorithm exhibited superior performance over the other ML algorithms and ACR TI-RADS and ATA. These criteria were obtained for ACR TI-RADS at 54.2%, 63.2%, 48.5%, 21.1%, and 84.8%, while for ATA, they were 44.3%, 76.3%, 27.2%, 18.4%, and 81.6%. In addition, the unnecessary fine-needle aspiration (FNA) rate with ACR TI-RADS and ATA was 43% and 63%, respectively-significantly higher than the 7% obtained with XGBoost. This study demonstrated the capability of ML approaches in enhancing the accuracy of predicting thyroid malignancy risks as well as their potential benefits in optimizing healthcare resources by reducing unnecessary FNA rates. Using the proposed model through a web-based tool can facilitate clinical judgments in thyroid nodule management and personalized treatment. Question Current risk assessment systems have limitations, with high unnecessary FNA rates compared to machine learning (ML) models. Findings The XGBoost algorithm was compared to other ML algorithms, ACR TI-RADS, and ATA and demonstrated superior performance. Clinical relevance This study demonstrated the capability of ML approaches in enhancing the accuracy of predicting thyroid malignancy. The proposed web-based tool to facilitate the prediction of thyroid nodule risk is available at https://aimedlab.ir/tnr .
- Open Access
- 19 June 2023
- Published by Springer Nature in BMC Medical Imaging
- Vol. 23 (1) , 1-10
Effect of ultrasound parameters of benign thyroid nodules on radiofrequency ablation efficacy
Background and aim: Ultrasound-guided radiofrequency ablation (RFA) is a minimally invasive therapy for thyroid nodules (TNs). Understanding the determinants of RFA efficacy can improve treatment and prognosis. This study aims to investigate the relationship between ultrasound parameters of benign TNs and the efficacy of RFA. Methods: A pretest–posttest interventional study was conducted in 2021 on 250 randomly sampled patients with benign TNs, receiving RFA. For this purpose, the volume reduction (VR) and the VR ratio (VRR) of the nodules were measured at the 1-, 3-, 6-, and 12-month follow-up periods after the RFA completion. The technical success rate (TSR) of this procedure was then categorized into four states, including low (VRR < 25%), moderate (VRR = 25–49%), high (VRR = 50–74%), and very high (VRR ≥ 75). Ordered logistic regression (OLR) was further utilized to investigate the effect of the ultrasound parameters of TNs on the TSR. The analyses were notably performed using Stata 14.2. Results: The VRR at the 1-, 3-, 6-, and 12-month follow-up periods were 38.7%, 53.6%, 59.3%, and 59.9%, respectively. The mean VR was also statistically significant at all follow-ups (p < 0.001). At the 1-, 3-, and 6-month follow-up periods, the VR of over 50% was observed in 28.2%, 52.1%, and 65.2% of the nodules, respectively. The odds ratios (ORs) of the RFA success were found to be 4.3 times higher for the nodules in the left lobe compared to the right lobe (OR: 4.31, p = 0.002), 6.3 times greater for isoechoic nodules compared to hyperechoic nodules (OR: 6.39, p < 0.001), 6.2 times higher for hyper-vascular nodules compared to hypo-vascular nodules (OR: 6.25, p = 0.005), and 2.3 times greater for mixed nodules compared to solid ones (OR: 2.37, p = 0.049). Conclusion: The ultrasound parameters of TNs had a statistically significant effect on the efficacy of RFA. Small-sized, isoechoic, and hyper-vascular nodules, as well as those with mixed tissue, were observed to respond better to RFA, leading to a better prognosis in terms of VR after treatment.
- 19 June 2023
- Published by Springer Nature in BMC Medical Imaging
- Vol. 23 (1) , 1-10
Open AccessEffect of ultrasound parameters of benign thyroid nodules on radiofrequency ablation efficacy
Background and aim: Ultrasound-guided radiofrequency ablation (RFA) is a minimally invasive therapy for thyroid nodules (TNs). Understanding the determinants of RFA efficacy can improve treatment and prognosis. This study aims to investigate the relationship between ultrasound parameters of benign TNs and the efficacy of RFA. Methods: A pretest–posttest interventional study was conducted in 2021 on 250 randomly sampled patients with benign TNs, receiving RFA. For this purpose, the volume reduction (VR) and the VR ratio (VRR) of the nodules were measured at the 1-, 3-, 6-, and 12-month follow-up periods after the RFA completion. The technical success rate (TSR) of this procedure was then categorized into four states, including low (VRR < 25%), moderate (VRR = 25–49%), high (VRR = 50–74%), and very high (VRR ≥ 75). Ordered logistic regression (OLR) was further utilized to investigate the effect of the ultrasound parameters of TNs on the TSR. The analyses were notably performed using Stata 14.2. Results: The VRR at the 1-, 3-, 6-, and 12-month follow-up periods were 38.7%, 53.6%, 59.3%, and 59.9%, respectively. The mean VR was also statistically significant at all follow-ups (p < 0.001). At the 1-, 3-, and 6-month follow-up periods, the VR of over 50% was observed in 28.2%, 52.1%, and 65.2% of the nodules, respectively. The odds ratios (ORs) of the RFA success were found to be 4.3 times higher for the nodules in the left lobe compared to the right lobe (OR: 4.31, p = 0.002), 6.3 times greater for isoechoic nodules compared to hyperechoic nodules (OR: 6.39, p < 0.001), 6.2 times higher for hyper-vascular nodules compared to hypo-vascular nodules (OR: 6.25, p = 0.005), and 2.3 times greater for mixed nodules compared to solid ones (OR: 2.37, p = 0.049). Conclusion: The ultrasound parameters of TNs had a statistically significant effect on the efficacy of RFA. Small-sized, isoechoic, and hyper-vascular nodules, as well as those with mixed tissue, were observed to respond better to RFA, leading to a better prognosis in terms of VR after treatment.
- Open Access
- 25 November 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (12) , 2950
Intraoperative Assessment of High-Risk Thyroid Nodules Based on Electrical Impedance Measurements: A Feasibility Study
Precise diagnosis of thyroid nodules is challenging due to non-diagnostic/inconclusive results and uncertainties about the malignancy of follicular neoplasms (FNs), even in frozen-section pathology. Therefore, surgical management, especially in Bethesda III and IV categories, may be complicated, and sometimes a second surgery may be required. The Thyroid Nodule Impedance Measurement System (TN-IMS) consists of a metallic patch attached to submental skin and a G20 I.V. cannula inserted into the targeted nodules. Two impedance-based parameters named Z1kHz and impedance phase slope (IPS) in 100 kHz to 500 kHz of the thyroid nodules are recorded and compared with their histopathological results as the gold standard. TN-IMS was intra-surgically applied to 103 human thyroid nodules and normal thyroid tissues. A remarkable consistency between defined co-ranges of Z1kHz/IPS and the histopathological status of specimens was achieved (p < 0.001). Based on these measurements, it was concluded that intraoperative bioelectrical impedance scanning of thyroid nodules would be a helpful complementary approach to detecting high-risk excision-required thyroid nodules.
- 25 November 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (12) , 2950
Open AccessIntraoperative Assessment of High-Risk Thyroid Nodules Based on Electrical Impedance Measurements: A Feasibility Study
Precise diagnosis of thyroid nodules is challenging due to non-diagnostic/inconclusive results and uncertainties about the malignancy of follicular neoplasms (FNs), even in frozen-section pathology. Therefore, surgical management, especially in Bethesda III and IV categories, may be complicated, and sometimes a second surgery may be required. The Thyroid Nodule Impedance Measurement System (TN-IMS) consists of a metallic patch attached to submental skin and a G20 I.V. cannula inserted into the targeted nodules. Two impedance-based parameters named Z1kHz and impedance phase slope (IPS) in 100 kHz to 500 kHz of the thyroid nodules are recorded and compared with their histopathological results as the gold standard. TN-IMS was intra-surgically applied to 103 human thyroid nodules and normal thyroid tissues. A remarkable consistency between defined co-ranges of Z1kHz/IPS and the histopathological status of specimens was achieved (p < 0.001). Based on these measurements, it was concluded that intraoperative bioelectrical impedance scanning of thyroid nodules would be a helpful complementary approach to detecting high-risk excision-required thyroid nodules.
- 23 January 2022
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 45 (5) , 677-684
Ultrasound-Guided Radiofrequency Ablation of Locally Recurrent Thyroid Carcinoma
Introduction We aimed to evaluate the effectiveness and safety of radiofrequency ablation (RFA) for non-surgical treatment of locally recurrent thyroid cancers, in both well-differentiated and medullary thyroid carcinomas (DTC and MTC) that are not amenable to traditional treatments. Methods We conducted a retrospective review of 48 patients with 103 recurrent tumors (81 DTC, 22 MTC) who underwent ultrasound-guided RFA. Patients were followed for 12–37 months to observe the outcomes and complications. Results 64 tumors (62.1%) completely disappeared at the last follow-up visit with 61 (59.2%) being resolved within 12 months. Technical success (volume reduction ratio (VRR) > 50%) was 96% (n = 99) in all tumors. The mean largest diameter of treated tumors decreased from 11.2 ± 5.3 to 2.4 ± 3.4 mm (p value < 0.001), and the mean volume decreased from 501.0 ± 807.0 to 41.6 ± 97.1 mm3 at the last follow-up (mean VRR = 91%). Our patients had a 77.1% recurrence-free survival rate (11 recurrences, 7 DTC, 4 MTC), with an overall mean recurrence-free survival time of 34.6 months (95% confidence interval, 30.0–39.1). We observed 3 cases with complications (voice changes in DTC patients) that completely resolved during follow-ups. Conclusion RFA is a safe and effective alternative to repetitive surgeries in recurrent loco-regional DTCs as well as MTCs. Level of Evidence Level 3, Non-randomized controlled cohort/follow-up study.
- 23 January 2022
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 45 (5) , 677-684
Ultrasound-Guided Radiofrequency Ablation of Locally Recurrent Thyroid Carcinoma
Introduction We aimed to evaluate the effectiveness and safety of radiofrequency ablation (RFA) for non-surgical treatment of locally recurrent thyroid cancers, in both well-differentiated and medullary thyroid carcinomas (DTC and MTC) that are not amenable to traditional treatments. Methods We conducted a retrospective review of 48 patients with 103 recurrent tumors (81 DTC, 22 MTC) who underwent ultrasound-guided RFA. Patients were followed for 12–37 months to observe the outcomes and complications. Results 64 tumors (62.1%) completely disappeared at the last follow-up visit with 61 (59.2%) being resolved within 12 months. Technical success (volume reduction ratio (VRR) > 50%) was 96% (n = 99) in all tumors. The mean largest diameter of treated tumors decreased from 11.2 ± 5.3 to 2.4 ± 3.4 mm (p value < 0.001), and the mean volume decreased from 501.0 ± 807.0 to 41.6 ± 97.1 mm3 at the last follow-up (mean VRR = 91%). Our patients had a 77.1% recurrence-free survival rate (11 recurrences, 7 DTC, 4 MTC), with an overall mean recurrence-free survival time of 34.6 months (95% confidence interval, 30.0–39.1). We observed 3 cases with complications (voice changes in DTC patients) that completely resolved during follow-ups. Conclusion RFA is a safe and effective alternative to repetitive surgeries in recurrent loco-regional DTCs as well as MTCs. Level of Evidence Level 3, Non-randomized controlled cohort/follow-up study.
- 10 May 2021
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 44 (10) , 1651-1656
Hydrodissection: A Novel Approach for Safe Core Needle Biopsy of Small High-Risk Subcapsular Thyroid Nodules
Purpose To evaluate the safety and effectiveness of core needle biopsy (CNB) under the assistance of hydrodissection (HDS). Materials and Methods Of 2325 patients requiring biopsy of thyroid lesions, 21 high-risk patients with subcapsular nodules smaller than 10 mm were recruited into this study. All patients underwent HDS with 0.9% saline solution followed by ultrasound (US)-guided CNB with an 18-gauge semi-automated biopsy needle. The separation success rate (SSR) of the HDS, technical success rate (TSR) of CNB, histopathologic success rate (HSR), and complications were assessed. Results Both the SSR of HDS and TSR of CNB were 100% (21/21). The HSR of the thyroid nodules was 85.7% (18/21). No major complications were recorded. Conclusion HDS before CNB can successfully lead to safe biopsy of small subcapsular thyroid nodules. Level of Evidence Level 4, Case Series
- 10 May 2021
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 44 (10) , 1651-1656
Hydrodissection: A Novel Approach for Safe Core Needle Biopsy of Small High-Risk Subcapsular Thyroid Nodules
Purpose To evaluate the safety and effectiveness of core needle biopsy (CNB) under the assistance of hydrodissection (HDS). Materials and Methods Of 2325 patients requiring biopsy of thyroid lesions, 21 high-risk patients with subcapsular nodules smaller than 10 mm were recruited into this study. All patients underwent HDS with 0.9% saline solution followed by ultrasound (US)-guided CNB with an 18-gauge semi-automated biopsy needle. The separation success rate (SSR) of the HDS, technical success rate (TSR) of CNB, histopathologic success rate (HSR), and complications were assessed. Results Both the SSR of HDS and TSR of CNB were 100% (21/21). The HSR of the thyroid nodules was 85.7% (18/21). No major complications were recorded. Conclusion HDS before CNB can successfully lead to safe biopsy of small subcapsular thyroid nodules. Level of Evidence Level 4, Case Series