H. Celik Ozyildirim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
H. Celik Ozyildirim has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Harikrishnan Nair
Virginia Transportation Research Council, Charlottesville, VA
3 shared publications- Mary Sharifi
Virginia Transportation Research Council, Charlottesville, VA
3 shared publications - Mustaque Hossain
Virginia Transportation Research Council, Charlottesville, VA
3 shared publications - Affan Habib
Associate Director, Virginia Center for Transportation Innovation and Research (VCTIR), Virginia Department of Transportation (VDOT), 530 Edgemont Rd, Charlottesville, VA 22903
1 shared publication - Amir Behravan
Virginia Transportation Research Council
1 shared publication - Chung Wu
Associate Director, Virginia Center for Transportation Innovation and Research (VCTIR), Virginia Department of Transportation (VDOT), 530 Edgemont Rd, Charlottesville, VA 22903
1 shared publication
Latest Publications
- Open Access
- 21 April 2025
- Published by MDPI AG in Infrastructures
- Vol. 10 (4) , 101
Repair and Treatment of Alkali–Silica Reaction (ASR)-Affected Transportation Infrastructures: Review and Interview
Alkali–silica reaction (ASR) can create significant cracking, compromising the durability and structural integrity of concrete elements. Currently, there is no known way to halt or reverse ASR damage, and the expansion will continue until it impairs ride quality or structural capacity, requiring the replacement of the affected elements. For certain existing structures or structural elements, the progression of an alkali–silica reaction may slow down depending on the type, dimensions of the affected element, service conditions, and environmental factors. Early intervention with repairs, however, may delay the need for replacement and extend the service life of the structure. Repair methods, such as crack filling, sealing, and breathable coatings, help reduce moisture intake and slow expansion. These repairs can also be combined with strengthening techniques to counteract the expansive forces caused by ASRs. The primary goal of these repairs is to extend the life of the structure until replacement or abandonment is necessary. There is a lack of information regarding the long-term performance of repairs and the most widely accepted repair methods. However, the literature and knowledge from the field shows that the time gained through these repairs varies significantly depending on location and exposure conditions, indicating that replacement remains the only reliable solution. Still, given that repairs can cost only 10–20% of full replacement, they remain a viable option for agencies managing limited budgets for immediate replacement.
- 21 April 2025
- Published by MDPI AG in Infrastructures
- Vol. 10 (4) , 101
Open AccessRepair and Treatment of Alkali–Silica Reaction (ASR)-Affected Transportation Infrastructures: Review and Interview
Alkali–silica reaction (ASR) can create significant cracking, compromising the durability and structural integrity of concrete elements. Currently, there is no known way to halt or reverse ASR damage, and the expansion will continue until it impairs ride quality or structural capacity, requiring the replacement of the affected elements. For certain existing structures or structural elements, the progression of an alkali–silica reaction may slow down depending on the type, dimensions of the affected element, service conditions, and environmental factors. Early intervention with repairs, however, may delay the need for replacement and extend the service life of the structure. Repair methods, such as crack filling, sealing, and breathable coatings, help reduce moisture intake and slow expansion. These repairs can also be combined with strengthening techniques to counteract the expansive forces caused by ASRs. The primary goal of these repairs is to extend the life of the structure until replacement or abandonment is necessary. There is a lack of information regarding the long-term performance of repairs and the most widely accepted repair methods. However, the literature and knowledge from the field shows that the time gained through these repairs varies significantly depending on location and exposure conditions, indicating that replacement remains the only reliable solution. Still, given that repairs can cost only 10–20% of full replacement, they remain a viable option for agencies managing limited budgets for immediate replacement.
- 17 May 2024
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2678 (11) , 791-797
Practical Approaches to Long-Lasting Bridge Decks
Concrete bridge decks are susceptible to deterioration, mainly in the form of cracking, spalling, and delaminations; this adversely affects the ride quality and structural integrity. Causes of deterioration are excessive loading, adverse environmental conditions, chemical reactions, electrochemical corrosion, poor structural design and detailing, improper construction practices, and insufficient specifications. Cracks in bridge decks provide avenues for water and solutions, mainly the chlorides, to penetrate the concrete and substantially diminish its service life. To achieve longer-lasting bridges, the quality of both the concrete and the reinforcement must be considered. The occurrence and width of cracks in bridge decks can be reduced using high-quality concrete and corrosion-resistant reinforcement. This paper details practical approaches to achieving long-lasting bridge decks through proper attention to design, selection of materials, construction practices, and specifications.
- 17 May 2024
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2678 (11) , 791-797
Practical Approaches to Long-Lasting Bridge Decks
Concrete bridge decks are susceptible to deterioration, mainly in the form of cracking, spalling, and delaminations; this adversely affects the ride quality and structural integrity. Causes of deterioration are excessive loading, adverse environmental conditions, chemical reactions, electrochemical corrosion, poor structural design and detailing, improper construction practices, and insufficient specifications. Cracks in bridge decks provide avenues for water and solutions, mainly the chlorides, to penetrate the concrete and substantially diminish its service life. To achieve longer-lasting bridges, the quality of both the concrete and the reinforcement must be considered. The occurrence and width of cracks in bridge decks can be reduced using high-quality concrete and corrosion-resistant reinforcement. This paper details practical approaches to achieving long-lasting bridge decks through proper attention to design, selection of materials, construction practices, and specifications.
- 5 March 2023
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2677 (6) , 827-836
Mass Concrete Mixtures Optimized for Temperature Control and High Workability
Mass concrete is prone to thermal cracking, deleterious chemical reactions, and ultimate strength reduction caused by a high temperature rise. Defining mass concrete has been difficult since many factors affect the thermal behavior and the distress formation. Mass concrete is usually reinforced and may have geometric constraints that require concretes with high workability, as with self-consolidating concrete. For high workability and strength, high amounts of cementitious material are used for stability and low water–cementitious material ratios. Such amounts generally cause high water and paste contents that lead to cracking because of moisture loss and thermal contraction. In this study, a practical and useful definition of mass concrete was explored. Concretes with low cementitious material contents and high workability were investigated. To minimize the total cementitious material and paste contents, optimum aggregate gradations were considered. To achieve and maintain high workability during construction, a combination of admixtures was used that included high-range water reducing, workability-retaining, and viscosity-modifying admixtures. Laboratory testing of concretes with reduced cementitious material contents including high amounts of the supplementary cementitious materials and a combination of admixtures showed that concretes with a decreased temperature rise, high workability, and adequate strength can be obtained.
- 5 March 2023
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2677 (6) , 827-836
Mass Concrete Mixtures Optimized for Temperature Control and High Workability
Mass concrete is prone to thermal cracking, deleterious chemical reactions, and ultimate strength reduction caused by a high temperature rise. Defining mass concrete has been difficult since many factors affect the thermal behavior and the distress formation. Mass concrete is usually reinforced and may have geometric constraints that require concretes with high workability, as with self-consolidating concrete. For high workability and strength, high amounts of cementitious material are used for stability and low water–cementitious material ratios. Such amounts generally cause high water and paste contents that lead to cracking because of moisture loss and thermal contraction. In this study, a practical and useful definition of mass concrete was explored. Concretes with low cementitious material contents and high workability were investigated. To minimize the total cementitious material and paste contents, optimum aggregate gradations were considered. To achieve and maintain high workability during construction, a combination of admixtures was used that included high-range water reducing, workability-retaining, and viscosity-modifying admixtures. Laboratory testing of concretes with reduced cementitious material contents including high amounts of the supplementary cementitious materials and a combination of admixtures showed that concretes with a decreased temperature rise, high workability, and adequate strength can be obtained.
- 7 May 2022
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2676 (10) , 251-264
Construction of a Composite Pavement (Asphalt over Concrete) in Virginia
The U.S. Strategic Highway Research Program 2 (SHRP2) identified composite pavement as a “renewal solution” and the Virginia Department of Transportation (VDOT) received implementation funding to demonstrate its feasibility. In 2017, this funding was applied to support major rehabilitation of two westbound lanes of US 60 in Henrico County, Virginia, a project that essentially replaced 1.1 mi of deteriorated concrete pavement with a new composite system consisting of continuously reinforced concrete pavement (CRCP) overlaid with stone matrix asphalt (SMA). This paper documents the design and construction of this new composite pavement. It also includes results from through-the-thickness temperature monitoring and a summary of performance for the first 4 years after opening to traffic. Close oversight by researchers provided a review of challenges and associated lessons learned from the design and construction process. Current VDOT specifications and standards were sufficient for successful construction. The asphalt overlay appeared to reduce the temperature gradient within the CRCP and to moderate daily temperature swings. This insulating effect of asphalt is expected to lower curling and associated stresses in the concrete pavement, which may permit reduced concrete thickness requirements in designs and also enable longer service life. The cracks in CRCP were tight and were not expected to reflect through the SMA. Moreover, the SMA mixture was tested to be crack and rut resistant. Therefore, a crack- and rut-free long service life for this composite pavement is expected. A recent visual survey by researchers found no observable distresses after 4 years under traffic.
- 7 May 2022
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2676 (10) , 251-264
Construction of a Composite Pavement (Asphalt over Concrete) in Virginia
The U.S. Strategic Highway Research Program 2 (SHRP2) identified composite pavement as a “renewal solution” and the Virginia Department of Transportation (VDOT) received implementation funding to demonstrate its feasibility. In 2017, this funding was applied to support major rehabilitation of two westbound lanes of US 60 in Henrico County, Virginia, a project that essentially replaced 1.1 mi of deteriorated concrete pavement with a new composite system consisting of continuously reinforced concrete pavement (CRCP) overlaid with stone matrix asphalt (SMA). This paper documents the design and construction of this new composite pavement. It also includes results from through-the-thickness temperature monitoring and a summary of performance for the first 4 years after opening to traffic. Close oversight by researchers provided a review of challenges and associated lessons learned from the design and construction process. Current VDOT specifications and standards were sufficient for successful construction. The asphalt overlay appeared to reduce the temperature gradient within the CRCP and to moderate daily temperature swings. This insulating effect of asphalt is expected to lower curling and associated stresses in the concrete pavement, which may permit reduced concrete thickness requirements in designs and also enable longer service life. The cracks in CRCP were tight and were not expected to reflect through the SMA. Moreover, the SMA mixture was tested to be crack and rut resistant. Therefore, a crack- and rut-free long service life for this composite pavement is expected. A recent visual survey by researchers found no observable distresses after 4 years under traffic.
- 19 January 2022
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2676 (5) , 686-694
High-Performance Fiber Reinforced Concretes in Virginia
High-performance fiber reinforced concretes (HPFRCs) provide high workability, high compressive and tensile strengths, high ductility, and high durability. They exhibit strain and deflection hardening. The Virginia Department of Transportation (VDOT), U.S., has been experimenting with various types of HPFRC, including high early strength versions, to control cracking in transverse and longitudinal connections, shear keys, blockouts that connect adjacent members, overlays, and inverts of corrugated metal pipe culverts. This paper presents laboratory and field work using three classes of HPFRC for different VDOT applications. They have high ductility and very low permeability. In addition, Class I has normal compressive strength, Class II has high compressive strength, and Class III has high early compressive strength. Laboratory work consisted of preparing and testing of in-house or prepackaged HPFRC with varying ingredients and proportions using compression, indirect tension, flexure, and pull-out tests. Synthetic and steel fibers were added in different amounts. Mixtures were prepared in the mortar or pan mixers that produce good fiber dispersion. Laboratory and field testing indicated that all three classes of HPFRC had high ductility; strengths varied according to the class. Engineered cementitious composite in Class I had normal strength, ultra-high-performance concrete in Class II had the highest strength, and concretes in Class III had high early strength, enabling minimal traffic interruption. HPFRC selected from an appropriate class can be used successfully to enable early opening to traffic, provide a short splice length, achieve satisfactory adjacent member connections, and restrict crack width for a longer service life.
- 19 January 2022
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2676 (5) , 686-694
High-Performance Fiber Reinforced Concretes in Virginia
High-performance fiber reinforced concretes (HPFRCs) provide high workability, high compressive and tensile strengths, high ductility, and high durability. They exhibit strain and deflection hardening. The Virginia Department of Transportation (VDOT), U.S., has been experimenting with various types of HPFRC, including high early strength versions, to control cracking in transverse and longitudinal connections, shear keys, blockouts that connect adjacent members, overlays, and inverts of corrugated metal pipe culverts. This paper presents laboratory and field work using three classes of HPFRC for different VDOT applications. They have high ductility and very low permeability. In addition, Class I has normal compressive strength, Class II has high compressive strength, and Class III has high early compressive strength. Laboratory work consisted of preparing and testing of in-house or prepackaged HPFRC with varying ingredients and proportions using compression, indirect tension, flexure, and pull-out tests. Synthetic and steel fibers were added in different amounts. Mixtures were prepared in the mortar or pan mixers that produce good fiber dispersion. Laboratory and field testing indicated that all three classes of HPFRC had high ductility; strengths varied according to the class. Engineered cementitious composite in Class I had normal strength, ultra-high-performance concrete in Class II had the highest strength, and concretes in Class III had high early strength, enabling minimal traffic interruption. HPFRC selected from an appropriate class can be used successfully to enable early opening to traffic, provide a short splice length, achieve satisfactory adjacent member connections, and restrict crack width for a longer service life.
- Open Access
- 11 June 2018
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2672 (27) , 78-87
Durable Concrete Overlays in Two Virginia Bridges
The purpose of this study was to implement innovative concretes with low permeability and reduced cracking potential in overlays to reduce chloride infiltration into the bridge decks. Two parallel bridges on Route 64 over Dunlap Creek in Alleghany County, Virginia, were selected for this study. For low cracking potential, relatively low water contents, shrinkage reducing admixtures, and lightweight aggregates were used. For low permeability, concretes had supplementary cementitious material and relatively low water–cementitious material ratios. In the overlays, five different materials were used: latex-modified concrete with rapid set cement; silica fume concrete alone; and silica fume concrete with shrinkage reducing admixture, lightweight coarse aggregate, and partial lightweight fine aggregate. A compressive strength of 3,000 psi at 3 days was sought. The performance of the overlay concretes was observed after two to three winters. The overlays used in this study achieved the specified strength and low permeability. There were minimal tight cracks except for one section with the latex-modified concrete with rapid set cement in the left lane of the westbound bridge. The extensive cracks in that section were attributed to plastic shrinkage from adverse weather conditions at placement and the fact that a truck had caught fire in that lane. Silica fume concrete overlays with shrinkage reducing admixture, lightweight coarse aggregate, or lightweight fine aggregate are ready for implementation in the field for low cracking overlays.
- 11 June 2018
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2672 (27) , 78-87
Open AccessDurable Concrete Overlays in Two Virginia Bridges
The purpose of this study was to implement innovative concretes with low permeability and reduced cracking potential in overlays to reduce chloride infiltration into the bridge decks. Two parallel bridges on Route 64 over Dunlap Creek in Alleghany County, Virginia, were selected for this study. For low cracking potential, relatively low water contents, shrinkage reducing admixtures, and lightweight aggregates were used. For low permeability, concretes had supplementary cementitious material and relatively low water–cementitious material ratios. In the overlays, five different materials were used: latex-modified concrete with rapid set cement; silica fume concrete alone; and silica fume concrete with shrinkage reducing admixture, lightweight coarse aggregate, and partial lightweight fine aggregate. A compressive strength of 3,000 psi at 3 days was sought. The performance of the overlay concretes was observed after two to three winters. The overlays used in this study achieved the specified strength and low permeability. There were minimal tight cracks except for one section with the latex-modified concrete with rapid set cement in the left lane of the westbound bridge. The extensive cracks in that section were attributed to plastic shrinkage from adverse weather conditions at placement and the fact that a truck had caught fire in that lane. Silica fume concrete overlays with shrinkage reducing admixture, lightweight coarse aggregate, or lightweight fine aggregate are ready for implementation in the field for low cracking overlays.
- Open Access
- 11 June 2018
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2672 (27) , 56-64
Bridge Substructure Repairs with Self-Consolidating Concrete and Galvanic Anodes
Historically, the Virginia Department of Transportation (VDOT) has repaired chloride-contaminated reinforced concrete bridge substructure elements that contain vertical and overhead sections with either shotcrete or a conventional A3 (3,000 psi) or A4 (4,000 psi) concrete. This study investigated using self-consolidating concrete (SCC), which has a high flow rate, bonds well, has low permeability, and provides smooth surfaces, as another option. The study also explored the use of galvanic anodes to control corrosion activity in SCC repairs. In VDOT’s Lynchburg and Staunton Districts, SCC repairs were made with and without the use of galvanic anodes. This provided a means for determining the benefit of using the anodes. The needed repair areas were determined by visual observation and sounding. After 7 years of service, SCC repair areas with and without anodes did not exhibit corrosion activity; small vertical cracks were evident in the SCC but did not affect performance. The anodes can provide protection to the steel immediately adjacent to the repair areas. However, unrepaired concrete areas away from the patched area with anodes now require additional repairs. SCC can be successfully placed; however, attention should be paid to form pressure and slump loss. Selection of repair areas should be based on corrosion-related measurements such as half-cell or chloride content, rather than sounding. Progression of corrosion demonstrates the necessity of removing all chloride-contaminated concrete not just adjacent to, but also away from the reinforcement, as anodes in the repair area will provide protection only in a narrow area around the patch.
- 11 June 2018
- Published by SAGE Publications in Transportation Research Record: Journal of the Transportation Research Board
- Vol. 2672 (27) , 56-64
Open AccessBridge Substructure Repairs with Self-Consolidating Concrete and Galvanic Anodes
Historically, the Virginia Department of Transportation (VDOT) has repaired chloride-contaminated reinforced concrete bridge substructure elements that contain vertical and overhead sections with either shotcrete or a conventional A3 (3,000 psi) or A4 (4,000 psi) concrete. This study investigated using self-consolidating concrete (SCC), which has a high flow rate, bonds well, has low permeability, and provides smooth surfaces, as another option. The study also explored the use of galvanic anodes to control corrosion activity in SCC repairs. In VDOT’s Lynchburg and Staunton Districts, SCC repairs were made with and without the use of galvanic anodes. This provided a means for determining the benefit of using the anodes. The needed repair areas were determined by visual observation and sounding. After 7 years of service, SCC repair areas with and without anodes did not exhibit corrosion activity; small vertical cracks were evident in the SCC but did not affect performance. The anodes can provide protection to the steel immediately adjacent to the repair areas. However, unrepaired concrete areas away from the patched area with anodes now require additional repairs. SCC can be successfully placed; however, attention should be paid to form pressure and slump loss. Selection of repair areas should be based on corrosion-related measurements such as half-cell or chloride content, rather than sounding. Progression of corrosion demonstrates the necessity of removing all chloride-contaminated concrete not just adjacent to, but also away from the reinforcement, as anodes in the repair area will provide protection only in a narrow area around the patch.
- 18 June 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 336-349
Rehabilitation of a Continuously Reinforced Concrete Pavement in Virginia
Asphalt overlays are typically used to extend the service life of continuously reinforced concrete pavement (CRCP) because they can be placed in one or more layers while traffic uses the adjacent lane and they can be opened to traffic in a short time. However, asphalt overlays must be replaced or resurfaced approximately every 10 years. Hydraulic cement concrete (HCC) overlays have also been used on occasion to rehabilitate and extend the life of CRCP longer than an asphalt overlay. However, HCC overlays are often not considered as an alternative to asphalt because of the higher initial cost of HCC. As the price of asphalt continues to increase, HCC overlays are becoming more competitive on an initial cost basis and more economical on a life cycle cost basis. The Virginia Department of Transportation recently initiated a project to rehabilitate a CRCP on US 58 using both bonded and unbonded concrete overlays. US 58 Westbound in Southampton County (MP 16.13 to MP 20.90) was selected as the candidate for the concrete overlay application. In Southampton County, US 58 is a four-lane, divided primary highway. Within the project limits, the existing pavement is an 8-in. continuously reinforced concrete pavement (CRCP) placed over a 6-in. cement treated aggregate (CTA) layer. VDOT specifies CTA as the dense graded aggregate stabilized with 4% cement by weight. The project includes two different overlay applications. The eastern portion of the pavement (about 2.6 miles) is a 4-in. bonded concrete overlay and the western section (about 2.2 miles) is a 7-in. unbonded concrete overlay with 1-in. asphalt separation layer. Saw cutting is used to form joints at 6-ft by 6-ft panels for unbonded overlay. Dowels are not used at the joints but tie bars are used along the center line of the pavement and on both shoulders. The shoulders along the unbounded overlay have the same concrete thickness as the mainline. The shoulders along the bonded overlay are asphalt. The objective of this project is to evaluate both bonded and unbonded hydraulic cement concrete (HCC) overlays to determine if they are a cost-effective and practical solution for extending the service life of existing CRCP. Initial conditions of the pavement and overlays along with the construction challenges are summarized.
- 18 June 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 336-349
Rehabilitation of a Continuously Reinforced Concrete Pavement in Virginia
Asphalt overlays are typically used to extend the service life of continuously reinforced concrete pavement (CRCP) because they can be placed in one or more layers while traffic uses the adjacent lane and they can be opened to traffic in a short time. However, asphalt overlays must be replaced or resurfaced approximately every 10 years. Hydraulic cement concrete (HCC) overlays have also been used on occasion to rehabilitate and extend the life of CRCP longer than an asphalt overlay. However, HCC overlays are often not considered as an alternative to asphalt because of the higher initial cost of HCC. As the price of asphalt continues to increase, HCC overlays are becoming more competitive on an initial cost basis and more economical on a life cycle cost basis. The Virginia Department of Transportation recently initiated a project to rehabilitate a CRCP on US 58 using both bonded and unbonded concrete overlays. US 58 Westbound in Southampton County (MP 16.13 to MP 20.90) was selected as the candidate for the concrete overlay application. In Southampton County, US 58 is a four-lane, divided primary highway. Within the project limits, the existing pavement is an 8-in. continuously reinforced concrete pavement (CRCP) placed over a 6-in. cement treated aggregate (CTA) layer. VDOT specifies CTA as the dense graded aggregate stabilized with 4% cement by weight. The project includes two different overlay applications. The eastern portion of the pavement (about 2.6 miles) is a 4-in. bonded concrete overlay and the western section (about 2.2 miles) is a 7-in. unbonded concrete overlay with 1-in. asphalt separation layer. Saw cutting is used to form joints at 6-ft by 6-ft panels for unbonded overlay. Dowels are not used at the joints but tie bars are used along the center line of the pavement and on both shoulders. The shoulders along the unbounded overlay have the same concrete thickness as the mainline. The shoulders along the bonded overlay are asphalt. The objective of this project is to evaluate both bonded and unbonded hydraulic cement concrete (HCC) overlays to determine if they are a cost-effective and practical solution for extending the service life of existing CRCP. Initial conditions of the pavement and overlays along with the construction challenges are summarized.