Deepak Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Deepak Kumar has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Basil Kuriachen
4 shared publications- Basil Kuriachen
National Institute of Technology Calicut
3 shared publications - Jibin T. Philip
Indian Institute of Science, Bangalore, India
3 shared publications - Jose Mathew
National Institute of Technology Calicut
2 shared publications - Maarten Pieter de Boer
Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
2 shared publications Vinyas Mahesh
2 shared publications
Latest Publications
- 11 February 2025
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 34 (18) , 20940-20962
Enhancing the Surface Tribological Properties of Ti6Al4V by Embedding SiC and Graphite through Powder Mixed Electrical Discharge Coating
- 11 February 2025
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 34 (18) , 20940-20962
Enhancing the Surface Tribological Properties of Ti6Al4V by Embedding SiC and Graphite through Powder Mixed Electrical Discharge Coating
- 6 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Absence of Electrical Contact Resistance Degradation in MEMS Relays Subject to Hot Switching
We conduct preliminary hot switching experiments in ultra-high purity nitrogen atmosphere on MEMS relays over two orders of magnitude supply voltage, $V_{s}$ , from 0.1 V to 10 V. In the relay design presented, a contact bar contacts two fixed traces, each platinum-coated, to achieve electrical continuity. For $\boldsymbol{V}_{s}\geq 0.5 \mathrm{V}$ , negligible change in electrical contact resistance is observed over twenty million cycles. There is, however, progressive morphological counterface damage evolution, which increases with $V_{s}$ . For mechanical cycling alone, wear can be observed over a small portion of the counterfaces. For $0.1 \leq V_{s}\leq 0.5 \mathrm{V}$ , counterface areal damage is approximately the same, but qualitatively different from that due to mechanical cycling. At $V_{s} = 10 V$ , damage manifests in the form of mounds and pits in one of the contacts pairs, suggestive of field evaporation. The other contact pair exhibits material transfer, indicative of electromigration. We attribute these observations to a small time difference in when the contact bar contacts each trace. These findings contribute to the fundamental understanding of reliability of electrical contacts and are important for nanoelectromechanical relays, which will operate below 1 V and in which hot switching is preferred in logic circuitry.- 6 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Absence of Electrical Contact Resistance Degradation in MEMS Relays Subject to Hot Switching
We conduct preliminary hot switching experiments in ultra-high purity nitrogen atmosphere on MEMS relays over two orders of magnitude supply voltage, $V_{s}$ , from 0.1 V to 10 V. In the relay design presented, a contact bar contacts two fixed traces, each platinum-coated, to achieve electrical continuity. For $\boldsymbol{V}_{s}\geq 0.5 \mathrm{V}$ , negligible change in electrical contact resistance is observed over twenty million cycles. There is, however, progressive morphological counterface damage evolution, which increases with $V_{s}$ . For mechanical cycling alone, wear can be observed over a small portion of the counterfaces. For $0.1 \leq V_{s}\leq 0.5 \mathrm{V}$ , counterface areal damage is approximately the same, but qualitatively different from that due to mechanical cycling. At $V_{s} = 10 V$ , damage manifests in the form of mounds and pits in one of the contacts pairs, suggestive of field evaporation. The other contact pair exhibits material transfer, indicative of electromigration. We attribute these observations to a small time difference in when the contact bar contacts each trace. These findings contribute to the fundamental understanding of reliability of electrical contacts and are important for nanoelectromechanical relays, which will operate below 1 V and in which hot switching is preferred in logic circuitry.- 10 April 2024
- Published by Elsevier in Tribology International
- Vol. 195, 109660
Tribological and corrosion behavior of hydrided zirconium alloy
- 10 April 2024
- Published by Elsevier in Tribology International
- Vol. 195, 109660
Tribological and corrosion behavior of hydrided zirconium alloy
- 5 February 2024
- Published by Elsevier in Materials Letters
- Vol. 361
Effect of mix cubic and hexagonal phase on the mechanical and microstructural properties of friction stir welded AZ31 alloy
- 5 February 2024
- Published by Elsevier in Materials Letters
- Vol. 361
Effect of mix cubic and hexagonal phase on the mechanical and microstructural properties of friction stir welded AZ31 alloy
- Open Access
- 8 January 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (2)
Low voltage cold and hot switching in nanoswitches cleaned by in situ oxygen plasma can achieve low stable contact resistance
Reliable nanoswitch operation requires low contact voltages and stable electrical contact resistance (ECR). Surface cleanliness is crucial to prevent nanomechanical switch failure, which can occur due to the presence of insulating adventitious hydrocarbon films. In situ O2 plasma cleaning is effective but oxidizes metal surfaces. Here, the noble metal Pt, which forms PtOx, is employed to form electrodes. Previous studies report on PtOx electrical resistivity, but the effects of PtOx evolution at contacting interfaces due to electrical and mechanical stimuli have not been explored. This study investigates the impact of PtOx on ECR at low contact voltages under hot switching, cold switching, and mechanical cycling conditions. An increase in ECR upon plasma cleaning indicates the presence of a resistive PtOx layer. After hot and cold switch cycling at applied voltages of 300 mV or less, a low stable ECR is achieved. A higher contact voltage accelerates ECR stabilization. The results are consistent with PtOx film volatilization, which is primarily due to Joule heating rather than mechanical rupture. This investigation advances the understanding of interface evolution in plasma-cleaned nanoswitches.
- 8 January 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (2)
Open AccessLow voltage cold and hot switching in nanoswitches cleaned by in situ oxygen plasma can achieve low stable contact resistance
Reliable nanoswitch operation requires low contact voltages and stable electrical contact resistance (ECR). Surface cleanliness is crucial to prevent nanomechanical switch failure, which can occur due to the presence of insulating adventitious hydrocarbon films. In situ O2 plasma cleaning is effective but oxidizes metal surfaces. Here, the noble metal Pt, which forms PtOx, is employed to form electrodes. Previous studies report on PtOx electrical resistivity, but the effects of PtOx evolution at contacting interfaces due to electrical and mechanical stimuli have not been explored. This study investigates the impact of PtOx on ECR at low contact voltages under hot switching, cold switching, and mechanical cycling conditions. An increase in ECR upon plasma cleaning indicates the presence of a resistive PtOx layer. After hot and cold switch cycling at applied voltages of 300 mV or less, a low stable ECR is achieved. A higher contact voltage accelerates ECR stabilization. The results are consistent with PtOx film volatilization, which is primarily due to Joule heating rather than mechanical rupture. This investigation advances the understanding of interface evolution in plasma-cleaned nanoswitches.
- 21 September 2023
- Published by Elsevier in Materials Letters
- Vol. 353
Role of interfacial shear strength in nanotribological behaviour of PTA deposited Colmonoy 6 coating on SS304 steel
- 21 September 2023
- Published by Elsevier in Materials Letters
- Vol. 353
Role of interfacial shear strength in nanotribological behaviour of PTA deposited Colmonoy 6 coating on SS304 steel
- Top Cited Papers
- 3 March 2023
- Published by Elsevier in Progress in Materials Science
- Vol. 136
Recent advances in tribology of high entropy alloys: A critical review
- 3 March 2023
- Published by Elsevier in Progress in Materials Science
- Vol. 136
Top Cited PapersRecent advances in tribology of high entropy alloys: A critical review
- 25 October 2022
- Published by Springer Nature in Transactions of the Indian Institute of Metals
- Vol. 76 (9) , 2353-2361
Study of Tribological Properties of EN8 Steel against Inconel X-750 Alloy under Dry and Lubricated Conditions
- 25 October 2022
- Published by Springer Nature in Transactions of the Indian Institute of Metals
- Vol. 76 (9) , 2353-2361
Study of Tribological Properties of EN8 Steel against Inconel X-750 Alloy under Dry and Lubricated Conditions
- 19 January 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology
- Vol. 236 (9) , 1761-1781
Optimization of tribological parameters to enhance wear and friction properties of Ti6Al4V alloy using Taguchi method
The present study is an endeavor to investigate the wear and friction behavior of Ti6Al4V against alumina (Al2O3) using a pin-on-disc tribometer at room temperature. The tests were performed for a given range of loads (10–90 N) and sliding velocities (0.5–4 m/s) for a sliding distance of 3000 m. The wear rate increased continuously with load and showed transition behavior with respect to the sliding velocity. Minimum friction was observed at the intermediate sliding velocities. Using the Taguchi tool, it was found that the load influenced the wear rate more significantly than the sliding velocity and the behavior was the opposite for the coefficient of friction. A wear model was predicted using regression, and subsequent confirmatory tests were carried out to validate the same. The ex-situ characterization of both worn-out surfaces and wear debris was conducted using Scanning Electron Microscope (SEM) along with the Energy Dispersion Spectroscopy (EDS) to study the surface morphology and level of oxidation, respectively. The wear mechanism was found to be a combination of adhesion, abrasion, oxidation, and delamination wear. The distinct lower wear rates at higher loads and velocities were attributed to the formation of Ti8O15 revealed by the X-ray diffraction (XRD) study.
- 19 January 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology
- Vol. 236 (9) , 1761-1781
Optimization of tribological parameters to enhance wear and friction properties of Ti6Al4V alloy using Taguchi method
The present study is an endeavor to investigate the wear and friction behavior of Ti6Al4V against alumina (Al2O3) using a pin-on-disc tribometer at room temperature. The tests were performed for a given range of loads (10–90 N) and sliding velocities (0.5–4 m/s) for a sliding distance of 3000 m. The wear rate increased continuously with load and showed transition behavior with respect to the sliding velocity. Minimum friction was observed at the intermediate sliding velocities. Using the Taguchi tool, it was found that the load influenced the wear rate more significantly than the sliding velocity and the behavior was the opposite for the coefficient of friction. A wear model was predicted using regression, and subsequent confirmatory tests were carried out to validate the same. The ex-situ characterization of both worn-out surfaces and wear debris was conducted using Scanning Electron Microscope (SEM) along with the Energy Dispersion Spectroscopy (EDS) to study the surface morphology and level of oxidation, respectively. The wear mechanism was found to be a combination of adhesion, abrasion, oxidation, and delamination wear. The distinct lower wear rates at higher loads and velocities were attributed to the formation of Ti8O15 revealed by the X-ray diffraction (XRD) study.
- 30 April 2021
- Published by ASME International in Journal of Tribology
- Vol. 143 (5)
Effect of Heat Treatment and Electric Discharge Alloying on the Tribological Performance of Selective Laser Melted AlSi10Mg
Selective laser melting (SLM) is an emerging additive manufacturing (AM) technology for fabrication of complex lightweight components along with improved mechanical properties. However, the properties are highly influenced by the continual heating and cooling during deposition, variation in local temperature, size, and shape of melt pool, and solidification growth rate. Therefore, postprocessing is very often required to control various properties of additive manufactured components. The present work investigates the influence of various postprocessing methods such as heat treatment and electric discharge alloying (EDA) on ambient and elevated temperature wear behavior of selective laser melted AlSi10Mg alloy and compared with its tribological behavior with cast AlSi10Mg. The dry wear tests were conducted using a pin on disk (POD) tribometer with EN-31 as counter body. The EDA treated SLM AlSi10Mg showed the least wear-rate and coefficient of friction (COF) at both ambient and elevated temperatures (1.05 × 10−4 mm3/Nm and 0.434 and 3.12 × 10−5 mm3/Nm and 0.531, respectively) due to its higher hardness (189.8 HV) as compared with other samples. The wear-rate and COF of cast specimen are found to be highest among all specimens at both ambient and elevated temperatures (1.34 × 10−4 mm3/Nm and 0.528 and 4.49 × 10−5 mm3/Nm and 0.724, respectively). Lower wear-rate and higher COF are observed at elevated temperature due to the excessive formation of wear-resistant oxides (Al2O3, SiO2, and MgO) and glaze layers for all samples compared with ambient temperature wear behaviors of its counterparts. Abrasive wear, adhesive wear, oxidation wear, and surface delamination are the prominent wear mechanisms observed for ambient and elevated temperatures for all the specimens.
- 30 April 2021
- Published by ASME International in Journal of Tribology
- Vol. 143 (5)
Effect of Heat Treatment and Electric Discharge Alloying on the Tribological Performance of Selective Laser Melted AlSi10Mg
Selective laser melting (SLM) is an emerging additive manufacturing (AM) technology for fabrication of complex lightweight components along with improved mechanical properties. However, the properties are highly influenced by the continual heating and cooling during deposition, variation in local temperature, size, and shape of melt pool, and solidification growth rate. Therefore, postprocessing is very often required to control various properties of additive manufactured components. The present work investigates the influence of various postprocessing methods such as heat treatment and electric discharge alloying (EDA) on ambient and elevated temperature wear behavior of selective laser melted AlSi10Mg alloy and compared with its tribological behavior with cast AlSi10Mg. The dry wear tests were conducted using a pin on disk (POD) tribometer with EN-31 as counter body. The EDA treated SLM AlSi10Mg showed the least wear-rate and coefficient of friction (COF) at both ambient and elevated temperatures (1.05 × 10−4 mm3/Nm and 0.434 and 3.12 × 10−5 mm3/Nm and 0.531, respectively) due to its higher hardness (189.8 HV) as compared with other samples. The wear-rate and COF of cast specimen are found to be highest among all specimens at both ambient and elevated temperatures (1.34 × 10−4 mm3/Nm and 0.528 and 4.49 × 10−5 mm3/Nm and 0.724, respectively). Lower wear-rate and higher COF are observed at elevated temperature due to the excessive formation of wear-resistant oxides (Al2O3, SiO2, and MgO) and glaze layers for all samples compared with ambient temperature wear behaviors of its counterparts. Abrasive wear, adhesive wear, oxidation wear, and surface delamination are the prominent wear mechanisms observed for ambient and elevated temperatures for all the specimens.