DBDaniel W. Byrne

Daniel W. Byrne

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daniel W. Byrne has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Randomized Evaluation of an Autoimmune Disease Prediction Model — AURA (AUtoimmune Risk Assessment)

    by April Barnado, Ryan P. Moore, Henry J. Domenico, Emily Grace, Sarah Green, Ashley Suh, Nikol Nikolova, Bryan Han, Allison B. McCoy, Daniel W. Byrne


  • Open Access

    Development and external validation of the NEO-READY model to predict date of discharge among premature neonatal intensive care patients

    by Hannah Lonsdale, Kevin Patel, Henry Domenico, Ryan S. Moore, Allison B. McCoy, Benjamin French, S. Trent Rosenbloom, Daniel W. Byrne, Robert E. Freundlich, Mhd Wael Alrifai

    OBJECTIVE: To develop a parsimonious, interpretable, and accurate model for predicting discharge for premature infants in the NICU that is suitable for prospective evaluation and integration into clinical workflows. STUDY DESIGN: Using routinely available electronic health record data, we developed and validated NEOnatal Reliable Estimation of Approaching Discharge in Young infants (NEO-READY), a daily-updating model that predicts likelihood of discharge within 5 days for premature infants. RESULTS: Data from 702 infants were used to develop the model, and data from 201 infants were used for temporal external validation. The model includes 13 predictors and two interaction terms and demonstrated excellent discrimination across development (AUC = 0.88, 95% CI 0.87-0.90) and validation (0.90, 0.88-0.91) cohorts. CONCLUSION: This work represents step 1 toward our long-term goal: integrating the NEO-READY model into clinical workflows as part of a comprehensive strategy to improve discharge preparedness, reduce discharge delays, and optimize NICU resources.

  • Open Access

    Quantifying the Accuracy of Clinician Risk Assessment for Postpartum Hemorrhage

    by Ashley N. Lewis, Diego Villela-Franyutti, Henry J. Domenico, Daniel W. Byrne, Michaela K. Farber, Holly B. Ende

    Objective: To measure the accuracy of postpartum hemorrhage (PPH) risk assessment performed by unaided individual clinicians, to inform future comparison to alternative risk assessment methods. Methods: Prospective PPH risk assessments were collected from obstetric care team clinicians at two quaternary medical centers in the United States (Vanderbilt University Medical Center, Brigham and Women’s Hospital) from January 2022 to January 2023, following written informed consent from the providers. The data included a cohort of both vaginal and cesarean deliveries (CD). For each assessment, the clinician quantified the patient’s predicted PPH risk on a scale from 0 to 100% and rated their confidence in these assessments using a 5-point Likert scale, ranging from ‘not at all confident’ to ‘completely confident’. Medical records were reviewed 24 hours postpartum to assess the dichotomous outcome of PPH, defined as blood loss ≥1000 mL. The accuracy of these predictions was evaluated using the area under the receiver operating characteristic curve (AUC). Results: Of 271 patients, 32 (11.8%) experienced PPH, accounting for 11.4% (104/915) of assessments. The overall AUC was 0.64 (95% confidence interval (CI): 0.58–0.71). Prediction accuracy was higher for CD than for vaginal deliveries, with AUCs of 0.82 (95% CI: 0.72–0.91) and 0.56 (95% CI: 0.48–0.63), respectively. No significant differences in the accuracy of assessments were observed according to physician specialty, physician experience level, or confidence level of the assessment. Conclusion: Overall unaided clinician performance in predicting PPH was moderate, with an AUC of 0.64. Predictions were more accurate for patients undergoing CD. Further study is needed to understand how clinician performance compares to other modalities of risk prediction.


  • Open Access

    Implementable Prediction of Pressure Injuries in Hospitalized Adults: Model Development and Validation

    by Thomas J Reese, Henry J Domenico, Antonio Hernandez, Daniel W Byrne, Ryan P Moore, Jessica B Williams, Brian J Douthit, Elise Russo, Allison B McCoy, Catherine H Ivory, et al.

    Background: Numerous pressure injury prediction models have been developed using electronic health record data, yet hospital-acquired pressure injuries (HAPIs) are increasing, which demonstrates the critical challenge of implementing these models in routine care. Objective: To help bridge the gap between development and implementation, we sought to create a model that was feasible, broadly applicable, dynamic, actionable, and rigorously validated and then compare its performance to usual care (ie, the Braden scale). Methods: We extracted electronic health record data from 197,991 adult hospital admissions with 51 candidate features. For risk prediction and feature selection, we used logistic regression with a least absolute shrinkage and selection operator (LASSO) approach. To compare the model with usual care, we used the area under the receiver operating curve (AUC), Brier score, slope, intercept, and integrated calibration index. The model was validated using a temporally staggered cohort. Results: A total of 5458 HAPIs were identified between January 2018 and July 2022. We determined 22 features were necessary to achieve a parsimonious and highly accurate model. The top 5 features included tracheostomy, edema, central line, first albumin measure, and age. Our model achieved higher discrimination than the Braden scale (AUC 0.897, 95% CI 0.893-0.901 vs AUC 0.798, 95% CI 0.791-0.803). Conclusions: We developed and validated an accurate prediction model for HAPIs that surpassed the standard-of-care risk assessment and fulfilled necessary elements for implementation. Future work includes a pragmatic randomized trial to assess whether our model improves patient outcomes.


  • Open Access

    Artificial Intelligence for Improved Patient Outcomes—The Pragmatic Randomized Controlled Trial Is the Secret Sauce

    by Daniel W. Byrne, Henry J. Domenico, Ryan P. Moore

    Byrne DW, et al. Korean J Radiol. 2024 Feb;25(2):123-125. https://doi.org/10.3348/kjr.2023.1016


  • External validation of a predictive model for reintubation after cardiac surgery: A retrospective, observational study

    by Robert E. Freundlich, Jacob C. Clifton, Richard H. Epstein, Pratik P. Pandharipande, Tristan R. Grogan, Ryan P. Moore, Daniel W. Byrne, Michael Fabbro, Ira S. Hofer


  • Palliative Care Exposure Relative to Predicted Risk of Six-Month Mortality in Hospitalized Adults

    by Rajiv Agarwal, Henry J. Domenico, Sreenivasa R. Balla, Daniel W. Byrne, Jennifer G. Whisenant, Marcella C. Woods, Barbara J. Martin, Mohana B. Karlekar, Marc L. Bennett


  • Spectral Doppler Index Mapping of the Umbilicoplacental Circulation and Pregnancy Outcome

    by Shoshana Haberman, Luis A. Bracero, Daniel W. Byrne

    Objective: To determine the value of Doppler measurements obtained by a new multigate Doppler modality, the spectral Doppler index mapping (SDIM) technique, to predict adverse outcome among pregnant women with normal conventional umbilical artery (UA) Doppler indices. Design: A cross-sectional prospective cohort study. Subjects: 183 women with well-dated singleton pregnancies who underwent prenatal ultrasound examination between 18 and 40 weeks of gestation were included in the study. At the time of the initial Doppler examination, all patients had normal UA and uterine artery Doppler indices, size appropriate for gestational age, no evidence of fetal anomalies or fetal distress. Methods: SDIM data included the distribution curves of the pulsatility indices (PI) as well as the mean of the PI detected in the placenta and in the umbilical cord. The mean PI values were also calculated using conventional spectral Doppler sonography. Logistic regression analysis was used to control for gestational age while assessing various Doppler variables in predicting outcome. Results: Adverse outcomes occurred in 26.6% of the pregnancies. In pregnancies with adverse outcome, the umbilicoplacental PI gradient was significantly lower (0.10 vs. 0.28, p < 0.003), the maximum intraplacental PI value was higher (1.28 vs. 1.16, p = 0.031), and there was a greater proportion with skewed UA distribution curves. Using forward stepwise logistic regression to compare the predictive value of the conventional Doppler ultrasound with SDIM, we found that the most accurate predictors of adverse outcome were the maximum intraplacental PI value (p < 0.028), skewed distributions (p = 0.002) and the gradient between the umbilical and intraplacental PI distributions (p = 0.006). Conclusions: Our results suggest that the SDIM system may enhance the ability of Doppler technology to predict obstetrical outcomes in patients with normal UA Doppler indices.