Adric C. L. Jones
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Adric C. L. Jones has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Farida A. Selim
Materials Science and Engineering Fulton Schools of Engineering Arizona State University Tempe Arizona USA
3 shared publications - Andreas Wagner
Institute of Radiation Physics, Helmholtz-Zentrum Dresden – Rossendorf, Dresden 01328, Germany
2 shared publications - Maik Butterling
Institute of Radiation Physics, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328 Dresden, Germany
2 shared publications - Thai Hang Chung
Materials Science and Engineering – School for Engineering of Matter, Transport & Energy, Arizona State University, Tempe, AZ 85281, USA
2 shared publications A Banković
Institute of Physics Belgrade, University of Belgrade, Pregrevica 118, POB 68, 11080 Zemun Serbia
1 shared publication- Allen Paine Mills
Department of Physics and Astronomy, University of California, Riverside, USA
1 shared publication
Latest Publications
- Open Access
Point Defects in MoNbTi-Based Refractory Multi-Principal-Element Alloys
As emergent material candidates for extreme environments, refractory high-entropy alloys (HEAs) or refractory multi-principal-element alloys (RMPEAs) comprising refractory metals feature qualities such as high radiation tolerance, corrosion resistance, and mechanical strength. A set of MoNbTi-based RMPEA samples with Al, Cr, V, and Zr additions are prepared by spark plasma sintering and investigated for their response to irradiation using 10 MeV Si+ ions with a dose of ions/cm2. Positron annihilation spectroscopy and transmission electron microscopy are employed as atomic- and meso- scale techniques to reveal how chemical complexity, nanotwinning, and phase fractions play an important role in radiation-induced defect accumulation and damage tolerance. The study provides experimental evidence of nanotwinning acting as an effective sink for radiation-induced point defects.Open AccessPoint Defects in MoNbTi-Based Refractory Multi-Principal-Element Alloys
As emergent material candidates for extreme environments, refractory high-entropy alloys (HEAs) or refractory multi-principal-element alloys (RMPEAs) comprising refractory metals feature qualities such as high radiation tolerance, corrosion resistance, and mechanical strength. A set of MoNbTi-based RMPEA samples with Al, Cr, V, and Zr additions are prepared by spark plasma sintering and investigated for their response to irradiation using 10 MeV Si+ ions with a dose of ions/cm2. Positron annihilation spectroscopy and transmission electron microscopy are employed as atomic- and meso- scale techniques to reveal how chemical complexity, nanotwinning, and phase fractions play an important role in radiation-induced defect accumulation and damage tolerance. The study provides experimental evidence of nanotwinning acting as an effective sink for radiation-induced point defects. - 28 March 2025
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 37 (18) , 185702
Positron stopping in multilayer materials
Positron annihilation spectroscopy provides a sensitive toolset for defect characterization. In beam based studies of single-layer targets, the form of implantation profiles is well established, depending on the kinetic energy and angle of incident positrons relative to the target surface and the density and average atomic number of the target. For multilayer systems, the difference in density and across the layers makes derivation of an analytical form difficult. To date, the determination of positron stopping profiles in multilayer targets has primarily involved Monte Carlo simulations. We present here an alternative approach that estimates the energy distribution d N / d E of those positrons transmitted past each layer boundary, by fitting the remaining tail of the stopping profile after each layer with a basis set comprised of calculated stopping profiles in the same material they are transmitted through. The stopping profile in the next layer is then found by summing a series of stopping profiles in the new medium in proportion to the determined distribution d N / d E . The results of our model are compared with simulation results in a system of alternating layers of Al and Au and find reasonable agreement in the predicted profile and excellent agreement in the predicted mean implantation depth. Lastly, we derived a simple formula-based approach for the calculation of the mean implantation depth in two-layer systems that provides results in excellent agreement with the full model.
- 28 March 2025
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 37 (18) , 185702
Positron stopping in multilayer materials
Positron annihilation spectroscopy provides a sensitive toolset for defect characterization. In beam based studies of single-layer targets, the form of implantation profiles is well established, depending on the kinetic energy and angle of incident positrons relative to the target surface and the density and average atomic number of the target. For multilayer systems, the difference in density and across the layers makes derivation of an analytical form difficult. To date, the determination of positron stopping profiles in multilayer targets has primarily involved Monte Carlo simulations. We present here an alternative approach that estimates the energy distribution d N / d E of those positrons transmitted past each layer boundary, by fitting the remaining tail of the stopping profile after each layer with a basis set comprised of calculated stopping profiles in the same material they are transmitted through. The stopping profile in the next layer is then found by summing a series of stopping profiles in the new medium in proportion to the determined distribution d N / d E . The results of our model are compared with simulation results in a system of alternating layers of Al and Au and find reasonable agreement in the predicted profile and excellent agreement in the predicted mean implantation depth. Lastly, we derived a simple formula-based approach for the calculation of the mean implantation depth in two-layer systems that provides results in excellent agreement with the full model.
- 1 April 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (4) , 043903
Development of a pulsed, variable-energy positron beam for atomic scale defect studies
Positron annihilation spectroscopy provides a sensitive means of non-destructive characterization of materials, capable of probing single atom vacancies in solids with 10−7 sensitivity. We detail here the development of a magnetically guided, variable energy, pulsed positron beam designed to conduct depth-dependent defect studies in metals, semiconductors, and dielectrics, which will be the first of its kind in the United States. The design of the target stage provides capabilities for measurements during in situ annealing up to 800 °C and incorporates a new approach to minimize the background due to energetic backscattered positrons. The developed beam at Bowling Green State University provides a powerful tool for characterization of thin films, devices, and ion irradiated materials.
- 1 April 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (4) , 043903
Development of a pulsed, variable-energy positron beam for atomic scale defect studies
Positron annihilation spectroscopy provides a sensitive means of non-destructive characterization of materials, capable of probing single atom vacancies in solids with 10−7 sensitivity. We detail here the development of a magnetically guided, variable energy, pulsed positron beam designed to conduct depth-dependent defect studies in metals, semiconductors, and dielectrics, which will be the first of its kind in the United States. The design of the target stage provides capabilities for measurements during in situ annealing up to 800 °C and incorporates a new approach to minimize the background due to energetic backscattered positrons. The developed beam at Bowling Green State University provides a powerful tool for characterization of thin films, devices, and ion irradiated materials.
- Open Access
- 25 March 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 131 (12) , 125903
The mechanism behind the high radiation tolerance of Fe–Cr alloys
Fe–Cr alloys are at the forefront for high radiation tolerant materials with long-standing validated performance. Yet, the detailed mechanism behind their high radiation resistance is in question and understanding the effect of varying Cr percentage is a grand challenge limiting further improvements. Here, we applied depth-resolved positron annihilation lifetime spectroscopy and Doppler broadening spectroscopy to study the effect of Cr alloying on the formation and evolution of atomic size clusters induced by ion-irradiation in Fe. We also used atom probe tomography to investigate the possible presence of Cr clusters or α′ phase precipitates with high Cr composition. The study reveals that the well-known resistance to radiation in Fe–Cr alloys may arise from the stabilization of vacancy clusters around Cr atoms, which act as sinks for radiation-induced defects. This implies that Cr atoms do not provide a direct sink for interstitials; rather defect complexes that consist of Cr atoms and vacancies, in turn, act as sinks for irradiation-induced vacancies and interstitials. we also find that lower amounts of Cr create smaller defect clusters that act as efficient sinks for radiation damage, but larger quantities of Cr form a defect structure that is less homogenous and larger in size, resulting in less efficient damage recombination. No evidence of α′ was found before or after irradiation, which indicates that it does not contribute to the observed radiation tolerance.
- 25 March 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 131 (12) , 125903
Open AccessThe mechanism behind the high radiation tolerance of Fe–Cr alloys
Fe–Cr alloys are at the forefront for high radiation tolerant materials with long-standing validated performance. Yet, the detailed mechanism behind their high radiation resistance is in question and understanding the effect of varying Cr percentage is a grand challenge limiting further improvements. Here, we applied depth-resolved positron annihilation lifetime spectroscopy and Doppler broadening spectroscopy to study the effect of Cr alloying on the formation and evolution of atomic size clusters induced by ion-irradiation in Fe. We also used atom probe tomography to investigate the possible presence of Cr clusters or α′ phase precipitates with high Cr composition. The study reveals that the well-known resistance to radiation in Fe–Cr alloys may arise from the stabilization of vacancy clusters around Cr atoms, which act as sinks for radiation-induced defects. This implies that Cr atoms do not provide a direct sink for interstitials; rather defect complexes that consist of Cr atoms and vacancies, in turn, act as sinks for irradiation-induced vacancies and interstitials. we also find that lower amounts of Cr create smaller defect clusters that act as efficient sinks for radiation damage, but larger quantities of Cr form a defect structure that is less homogenous and larger in size, resulting in less efficient damage recombination. No evidence of α′ was found before or after irradiation, which indicates that it does not contribute to the observed radiation tolerance.
- 1 January 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (1) , 013305
A resistive-anode based position-sensitive Rydberg atom detector
We describe here the development and characterization of a position-sensitive detector for Rydberg atom experiments. The detector builds on an earlier design that field-ionized incident Rydberg positronium (Ps) atoms and then electrostatically focused the freed positrons onto a micro-channel plate (MCP) detector without the use of a position sensitive anode. In this design, pulses from the MCP are deposited onto a resistive anode, providing a means of measuring the incident particles’ x, y positions. The first detector constructed utilized a pair of MCPs in a chevron configuration and was used to observe the focusing of Rydberg Ps atoms from an electrostatic mirror. A second detector, developed for use in a measurement of the 1S–2S interval of Ps, incorporates three MCPs in a Z-stack configuration to produce larger pulses. Using a UV-induced signal, we have characterized the performance of the assembled detectors, finding a spatial resolution of mm for the largest induced pulses and for pulse widths of ∼7–10 ns FWHM; pulse times can be resolved to better than 1 ns. The Ps induced signal is anticipated to yield pulses times larger, which are expected to achieve a spatial resolution of mm. Appropriate lenses could make possible applications involving either imaging a large area or magnifying a small area of the incident Ps spatial distribution.- 1 January 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (1) , 013305
A resistive-anode based position-sensitive Rydberg atom detector
We describe here the development and characterization of a position-sensitive detector for Rydberg atom experiments. The detector builds on an earlier design that field-ionized incident Rydberg positronium (Ps) atoms and then electrostatically focused the freed positrons onto a micro-channel plate (MCP) detector without the use of a position sensitive anode. In this design, pulses from the MCP are deposited onto a resistive anode, providing a means of measuring the incident particles’ x, y positions. The first detector constructed utilized a pair of MCPs in a chevron configuration and was used to observe the focusing of Rydberg Ps atoms from an electrostatic mirror. A second detector, developed for use in a measurement of the 1S–2S interval of Ps, incorporates three MCPs in a Z-stack configuration to produce larger pulses. Using a UV-induced signal, we have characterized the performance of the assembled detectors, finding a spatial resolution of mm for the largest induced pulses and for pulse widths of ∼7–10 ns FWHM; pulse times can be resolved to better than 1 ns. The Ps induced signal is anticipated to yield pulses times larger, which are expected to achieve a spatial resolution of mm. Appropriate lenses could make possible applications involving either imaging a large area or magnifying a small area of the incident Ps spatial distribution.- Open Access
- 1 April 2009
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 162 (1) , 012002
Low energy positron interactions - trapping, transport and scattering
Recent experiments, theory and modelling of positron interactions with atoms and molecules are discussed. The first half of the paper is devoted to binary collisions between positrons and crossed beams of atoms or molecules (in this case neon) and the second half deals with ensembles of non-interacting positrons, otherwise known as swarms which are transported through the background gas. We review the recent results on measurements of the cross sections based on obtained from collisional positron traps and subsequent calculations of transport properties of positron swarms that may be used to model thermalization experiments, collisional traps and possible applications of positrons in materials science and biomedicine. It was found that kinetic phenomena occur in positron transport that are mainly the result of the positronium (Ps) formation which has a larger cross section than elastic scattering in most gases and at the same time is a non-conservative process. Most importantly negative differential conductivity (NDC) occurs only for the bulk drift velocity while it does not exist for the flux property, a phenomenon that has not been observed for electrons.
- 1 April 2009
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 162 (1) , 012002
Open AccessLow energy positron interactions - trapping, transport and scattering
Recent experiments, theory and modelling of positron interactions with atoms and molecules are discussed. The first half of the paper is devoted to binary collisions between positrons and crossed beams of atoms or molecules (in this case neon) and the second half deals with ensembles of non-interacting positrons, otherwise known as swarms which are transported through the background gas. We review the recent results on measurements of the cross sections based on obtained from collisional positron traps and subsequent calculations of transport properties of positron swarms that may be used to model thermalization experiments, collisional traps and possible applications of positrons in materials science and biomedicine. It was found that kinetic phenomena occur in positron transport that are mainly the result of the positronium (Ps) formation which has a larger cross section than elastic scattering in most gases and at the same time is a non-conservative process. Most importantly negative differential conductivity (NDC) occurs only for the bulk drift velocity while it does not exist for the flux property, a phenomenon that has not been observed for electrons.