Mohamed Ali Torad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohamed Ali Torad has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Ali Torad
Department of Physical Therapy and Health Rehabilitation, Jouf University, Sakaka 72341, Saudi Arabia
4 shared publications - Mona Mohamed Taha
Department of Rehabilitation Sciences, College of Health and Rehabilitation Sciences, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
4 shared publications - Eslam Samy El-Mokadem
Department of Electronics and Communication Engineering, Higher Technological Institute (HTI), 10th of Ramadan City 44634, Egypt
3 shared publications - Mohamed Abdelaziz Emam
Department of Basic Sciences, Faculty of Physical Therapy, Kafrelsheikh University, Kafrelsheikh 33516, Egypt
3 shared publications - Abdelmoty M. Ahmed
Ajloun National University
2 shared publications - Samy E. El-Mokadem
Department of Computer Science Faculty of Information Systems and Computer Science October 6 University October City Egypt
2 shared publications
Latest Publications
- Open Access
- 16 November 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Real-time embedded control and performance evaluation of BLDC motors for electric vehicle applications
Brushless DC (BLDC) motors are central to modern electric vehicle (EV) drivetrains, yet achieving high efficiency and stable torque under dynamic conditions remains a significant engineering challenge. This study presents the design and real-time embedded implementation of a motor control system realised on the STM32F103C8T6 microcontroller, together with a hardware-parameterised performance characterisation used to evaluate and cross-validate its behaviour. Two established control strategies—Trapezoidal Commutation and Field-Oriented Control (FOC)—were implemented independently on the same hardware platform under identical load conditions to enable a direct, unbiased comparison. The system incorporates Hall-effect sensor-based rotor position detection, closed-loop PI control (speed for Trapezoidal, d/q current for FOC), Direct Memory Access (DMA) for high-speed data acquisition, and a Controller Area Network (CAN) / Universal Asynchronous Receiver-Transmitter (UART) framework for real-time parameter transmission to a driver-facing display. Characterised performance results, derived from the implemented hardware's own rated parameters, show that FOC achieves a peak efficiency of 92% versus 86% under Trapezoidal Control, with torque ripple reduced by approximately 40% and peak current lowered from 50 to 44 A. The characterised thermal behaviour indicates that FOC maintains motor temperatures below 70 °C at full load, whereas Trapezoidal Control approaches critical thresholds under equivalent conditions. The modular architecture supports scalability across microcontroller tiers and EV configurations, providing a validated and deployable reference for energy-efficient BLDC drive systems.
- 16 November 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessReal-time embedded control and performance evaluation of BLDC motors for electric vehicle applications
Brushless DC (BLDC) motors are central to modern electric vehicle (EV) drivetrains, yet achieving high efficiency and stable torque under dynamic conditions remains a significant engineering challenge. This study presents the design and real-time embedded implementation of a motor control system realised on the STM32F103C8T6 microcontroller, together with a hardware-parameterised performance characterisation used to evaluate and cross-validate its behaviour. Two established control strategies—Trapezoidal Commutation and Field-Oriented Control (FOC)—were implemented independently on the same hardware platform under identical load conditions to enable a direct, unbiased comparison. The system incorporates Hall-effect sensor-based rotor position detection, closed-loop PI control (speed for Trapezoidal, d/q current for FOC), Direct Memory Access (DMA) for high-speed data acquisition, and a Controller Area Network (CAN) / Universal Asynchronous Receiver-Transmitter (UART) framework for real-time parameter transmission to a driver-facing display. Characterised performance results, derived from the implemented hardware's own rated parameters, show that FOC achieves a peak efficiency of 92% versus 86% under Trapezoidal Control, with torque ripple reduced by approximately 40% and peak current lowered from 50 to 44 A. The characterised thermal behaviour indicates that FOC maintains motor temperatures below 70 °C at full load, whereas Trapezoidal Control approaches critical thresholds under equivalent conditions. The modular architecture supports scalability across microcontroller tiers and EV configurations, providing a validated and deployable reference for energy-efficient BLDC drive systems.
- Open Access
An ESP32-S3 Multimodal Wearable Sensor Platform with Embedded XGBoost for Focal-to-Bilateral Tonic–Clonic Seizure Detection and IoT Alerting
Wearable seizure-detection systems can provide objective event monitoring and rapid caregiver alerting without continuous bedside observation. This study presents a resource-constrained multimodal wearable sensor platform for focal-to-bilateral tonic–clonic seizure (FBTCS) detection using edge artificial intelligence and Internet of Things (IoT) communication. The prototype integrates an ESP32-S3 microcontroller, an analog electromyography (EMG) channel, an MPU6050 inertial sensor, MAX30102 photoplethysmography, GPS, a TFT display, local vibration/buzzer outputs, and Blynk cloud telemetry. The seizure–decision path uses synchronized EMG and acceleration acquired at 100 Hz in non-overlapping 10 s windows. EMG and acceleration are resampled for compatibility with the reference feature pipeline, 13 statistical features are extracted from each modality (26 total), and an 85-tree XGBoost model is executed locally. A probability threshold of 0.85 is combined with temporal smoothing, consecutive-window confirmation, and a 60 s refractory interval. Software verification showed maximum absolute probability differences of approximately 1.19 × 10−7 for random feature-vector tests and 1.49 × 10−8 for end-to-end recorded windows relative to the Python reference. Within the reported validation record covering 2643.69 h and 18 record-labeled FBTCS events, 12 events were detected (12/18; 67% sensitivity). Precision was approximately 26%, F1-score approximately 38%, the reported false-alarm rate was 0.31 per 24 h, and median detection latency was 61.5 s. Approximately 34 false alarms are estimated from the reported false-alarm rate and evaluation duration; this is an estimated count rather than a percentage or directly observed count. Hardware, local alarm, display, GPS, and cloud communication functions passed functional integration tests. The small event count, uncertain label provenance, low precision, and long latency mean that these data support an engineering proof-of-concept only and do not establish clinical applicability.
Open AccessAn ESP32-S3 Multimodal Wearable Sensor Platform with Embedded XGBoost for Focal-to-Bilateral Tonic–Clonic Seizure Detection and IoT Alerting
Wearable seizure-detection systems can provide objective event monitoring and rapid caregiver alerting without continuous bedside observation. This study presents a resource-constrained multimodal wearable sensor platform for focal-to-bilateral tonic–clonic seizure (FBTCS) detection using edge artificial intelligence and Internet of Things (IoT) communication. The prototype integrates an ESP32-S3 microcontroller, an analog electromyography (EMG) channel, an MPU6050 inertial sensor, MAX30102 photoplethysmography, GPS, a TFT display, local vibration/buzzer outputs, and Blynk cloud telemetry. The seizure–decision path uses synchronized EMG and acceleration acquired at 100 Hz in non-overlapping 10 s windows. EMG and acceleration are resampled for compatibility with the reference feature pipeline, 13 statistical features are extracted from each modality (26 total), and an 85-tree XGBoost model is executed locally. A probability threshold of 0.85 is combined with temporal smoothing, consecutive-window confirmation, and a 60 s refractory interval. Software verification showed maximum absolute probability differences of approximately 1.19 × 10−7 for random feature-vector tests and 1.49 × 10−8 for end-to-end recorded windows relative to the Python reference. Within the reported validation record covering 2643.69 h and 18 record-labeled FBTCS events, 12 events were detected (12/18; 67% sensitivity). Precision was approximately 26%, F1-score approximately 38%, the reported false-alarm rate was 0.31 per 24 h, and median detection latency was 61.5 s. Approximately 34 false alarms are estimated from the reported false-alarm rate and evaluation duration; this is an estimated count rather than a percentage or directly observed count. Hardware, local alarm, display, GPS, and cloud communication functions passed functional integration tests. The small event count, uncertain label provenance, low precision, and long latency mean that these data support an engineering proof-of-concept only and do not establish clinical applicability.
- Open Access
- 22 October 2026
- Published by MDPI AG in Healthcare
- Vol. 14 (21) , 3573
Psychological Distress, Daytime Sleepiness, Fatigue, and Health-Related Quality of Life in Young Adults: A Cross-Sectional Study with Implications for Rehabilitation
Background/Objectives: This study examined associations between psychological distress, daytime sleepiness, mental and physical fatigue, and HRQoL in young adults and identified key predictors relevant for rehabilitation-oriented screening and intervention. Methods: In this cross-sectional analytical study, 371 university students (18–25 years) completed the Epworth Sleepiness Scale, Depression Anxiety Stress Scales-21, Fatigue Assessment Scale, and 12-Item Short Form Health Survey. Descriptive statistics, one-way ANOVA, multivariate general linear models, multiple linear regression, and logistic regression were applied to evaluate associations with fatigue and SF-12 physical and mental health scores and categories. Results: Most participants reported mild–moderate distress and fatigue, and about half of the participants had SF-12 scores below the sample median. Severe mental and physical fatigue were associated with substantially higher stress, anxiety, and depression than normal fatigue (all p < 0.001). Psychological variables explained 52% of the variance in mental fatigue and 30% in physical fatigue, with lower R2 for SF-12 physical (0.17) and mental health (0.29). Depression and stress were the strongest predictors of mental fatigue and low SF-12 mental health scores, whereas anxiety was more closely related to physical fatigue and physical health. Sleepiness showed weak, inconsistent associations after adjustment. Higher distress categories significantly increased the odds of HRQoL below the sample median. Conclusions: Psychological distress, particularly depression and stress, was strongly associated with fatigue and was also associated with poorer health-related quality of life, although the adjusted models indicated a more modest contribution to HRQoL. The findings support the value of considering psychological distress in rehabilitation-oriented screening while recognizing that HRQoL is influenced by multiple factors.
- 22 October 2026
- Published by MDPI AG in Healthcare
- Vol. 14 (21) , 3573
Open AccessPsychological Distress, Daytime Sleepiness, Fatigue, and Health-Related Quality of Life in Young Adults: A Cross-Sectional Study with Implications for Rehabilitation
Background/Objectives: This study examined associations between psychological distress, daytime sleepiness, mental and physical fatigue, and HRQoL in young adults and identified key predictors relevant for rehabilitation-oriented screening and intervention. Methods: In this cross-sectional analytical study, 371 university students (18–25 years) completed the Epworth Sleepiness Scale, Depression Anxiety Stress Scales-21, Fatigue Assessment Scale, and 12-Item Short Form Health Survey. Descriptive statistics, one-way ANOVA, multivariate general linear models, multiple linear regression, and logistic regression were applied to evaluate associations with fatigue and SF-12 physical and mental health scores and categories. Results: Most participants reported mild–moderate distress and fatigue, and about half of the participants had SF-12 scores below the sample median. Severe mental and physical fatigue were associated with substantially higher stress, anxiety, and depression than normal fatigue (all p < 0.001). Psychological variables explained 52% of the variance in mental fatigue and 30% in physical fatigue, with lower R2 for SF-12 physical (0.17) and mental health (0.29). Depression and stress were the strongest predictors of mental fatigue and low SF-12 mental health scores, whereas anxiety was more closely related to physical fatigue and physical health. Sleepiness showed weak, inconsistent associations after adjustment. Higher distress categories significantly increased the odds of HRQoL below the sample median. Conclusions: Psychological distress, particularly depression and stress, was strongly associated with fatigue and was also associated with poorer health-related quality of life, although the adjusted models indicated a more modest contribution to HRQoL. The findings support the value of considering psychological distress in rehabilitation-oriented screening while recognizing that HRQoL is influenced by multiple factors.
- Open Access
ESP32-S3-Based Multimodal Wearable for Remote Vital-Sign Acquisition with ECG-to-PPG Pulse-Arrival-Time Tracking and Functional Cloud Triage: An Engineering Proof of Concept
Continuous remote physiological monitoring requires low-cost sensing nodes to preserve timing fidelity while maintaining secure connectivity and interpretable escalation. This study presents an engineering proof-of-concept platform centered on an ESP32-S3 with AD8232 ECG, MAX30102 PPG/SpO2, and MAX30205 contact-temperature sensing. FreeRTOS separates nominal 100 Hz ECG/PPG acquisition from network communication, and the ECG R-wave-to-peripheral-PPG-foot interval is treated as pulse-arrival time (PAT). Telemetry is transmitted over authenticated HTTPS to a Laravel platform, while a separate FastAPI service provides human-in-the-loop normal/warning/critical functional triage. The current evidence is limited to bench-top engineering operation and synthetically constructed triage scenarios; no human-participant measurements are analyzed or reported. An ethics-approved rest-exertion-recovery protocol has been prepared for a future validation stage. The present results support system integration and engineering feasibility, while physiological accuracy, PAT-to-blood-pressure calibration, respiratory-rate agreement, classifier performance, timing reliability, and battery/power characteristics remain to be established quantitatively.
Open AccessESP32-S3-Based Multimodal Wearable for Remote Vital-Sign Acquisition with ECG-to-PPG Pulse-Arrival-Time Tracking and Functional Cloud Triage: An Engineering Proof of Concept
Continuous remote physiological monitoring requires low-cost sensing nodes to preserve timing fidelity while maintaining secure connectivity and interpretable escalation. This study presents an engineering proof-of-concept platform centered on an ESP32-S3 with AD8232 ECG, MAX30102 PPG/SpO2, and MAX30205 contact-temperature sensing. FreeRTOS separates nominal 100 Hz ECG/PPG acquisition from network communication, and the ECG R-wave-to-peripheral-PPG-foot interval is treated as pulse-arrival time (PAT). Telemetry is transmitted over authenticated HTTPS to a Laravel platform, while a separate FastAPI service provides human-in-the-loop normal/warning/critical functional triage. The current evidence is limited to bench-top engineering operation and synthetically constructed triage scenarios; no human-participant measurements are analyzed or reported. An ethics-approved rest-exertion-recovery protocol has been prepared for a future validation stage. The present results support system integration and engineering feasibility, while physiological accuracy, PAT-to-blood-pressure calibration, respiratory-rate agreement, classifier performance, timing reliability, and battery/power characteristics remain to be established quantitatively.
- Open Access
IoT-Based Isolation Ward Monitoring System Prototype
The COVID-19 pandemic exposed critical vulnerabilities in healthcare systems worldwide, placing healthcare workers (HCWs) at severe infection risk through direct patient contact. Epidemiological data confirm that HCWs were approximately seven times more likely to develop severe COVID-19 than other occupations, with over 7000 HCW deaths recorded globally by mid-2020. This paper presents the design and laboratory proof-of-concept validation of an IoT-based remote patient-monitoring system prototype—the IoT-Based Isolation Ward Monitoring System Prototype—designed to eliminate unnecessary patient-to-HCW physical contact while maintaining continuous, real-time physiological surveillance. The system integrates multi-sensor hardware comprising an AD8232 ECG module, a MAX30100 pulse oximeter, an NTC thermistor, and an MQ-135 sensor. These sensors interface with an Arduino UNO for data acquisition, while localized edge computing is executed on a Raspberry Pi 3B. A convolutional neural network (CNN) trained on the MIT-BIH Arrhythmia Database classifies heartbeats into five distinct categories. By utilizing SMOTE resampling on 109,446 samples, the network achieves an on-device inference latency of under 200 ms. The sensor data are transmitted to a Firebase Realtime Database via an authenticated REST API, which synchronizes data across dual front-end interfaces: a LabVIEW desktop dashboard for clinical oversight and a cross-platform Flutter mobile application for mobile monitoring. End-to-end technical validation under controlled laboratory conditions confirmed round-trip cloud latencies between 300 and 800 ms, error-free threshold alert generation, and sub-second latency for the integrated chat utility. The proposed system uniquely combines hardware sensing, ML-based ECG classification, cloud storage, a LabVIEW physician dashboard, and bidirectional doctor–patient mobile communication into a single unified, low-cost platform.Open AccessIoT-Based Isolation Ward Monitoring System Prototype
The COVID-19 pandemic exposed critical vulnerabilities in healthcare systems worldwide, placing healthcare workers (HCWs) at severe infection risk through direct patient contact. Epidemiological data confirm that HCWs were approximately seven times more likely to develop severe COVID-19 than other occupations, with over 7000 HCW deaths recorded globally by mid-2020. This paper presents the design and laboratory proof-of-concept validation of an IoT-based remote patient-monitoring system prototype—the IoT-Based Isolation Ward Monitoring System Prototype—designed to eliminate unnecessary patient-to-HCW physical contact while maintaining continuous, real-time physiological surveillance. The system integrates multi-sensor hardware comprising an AD8232 ECG module, a MAX30100 pulse oximeter, an NTC thermistor, and an MQ-135 sensor. These sensors interface with an Arduino UNO for data acquisition, while localized edge computing is executed on a Raspberry Pi 3B. A convolutional neural network (CNN) trained on the MIT-BIH Arrhythmia Database classifies heartbeats into five distinct categories. By utilizing SMOTE resampling on 109,446 samples, the network achieves an on-device inference latency of under 200 ms. The sensor data are transmitted to a Firebase Realtime Database via an authenticated REST API, which synchronizes data across dual front-end interfaces: a LabVIEW desktop dashboard for clinical oversight and a cross-platform Flutter mobile application for mobile monitoring. End-to-end technical validation under controlled laboratory conditions confirmed round-trip cloud latencies between 300 and 800 ms, error-free threshold alert generation, and sub-second latency for the integrated chat utility. The proposed system uniquely combines hardware sensing, ML-based ECG classification, cloud storage, a LabVIEW physician dashboard, and bidirectional doctor–patient mobile communication into a single unified, low-cost platform. - Open Access
- 1 February 2026
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 15 (1) , 237-252
Design and evaluation of a Python-based network automation system for internet of things devices
The increasing demand for the internet of things (IoT) and massive machine-type communications has significantly expanded network size and complexity. Recent research indicates that 95% of network tasks are monitored manually, leading to configuration complexity, human errors, faults, downtime risks, and time consumption. Network automation emerges as a practical solution by reducing administrative overhead and enabling reliable, scalable, and self-managing networks through scripting and standardized programming languages. This paper proposes a model for automated networks using Python-based methods, specifically Paramiko, Netmiko, and the network automation and programmability abstraction layer with multivendor support (NAPALM), to configure the enhanced interior gateway routing protocol (EIGRP) within the graphical network simulator-3(GNS3) environment. The performance of the automated network was evaluated using two scenarios: with threading and without threading. Key metrics included execution time, configuration accuracy, error rates, and resource utilization. Simulation results demonstrate that the automated approach significantly outperforms manual configuration. In addition, the automated model with threading outperformed the automated model without threading, achieving execution time reductions up to 67% and 100% configuration accuracy with zero errors. These findings underscore the effectiveness of the proposed system for automating complex network tasks in large-scale IoT deployments.
- 1 February 2026
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 15 (1) , 237-252
Open AccessDesign and evaluation of a Python-based network automation system for internet of things devices
The increasing demand for the internet of things (IoT) and massive machine-type communications has significantly expanded network size and complexity. Recent research indicates that 95% of network tasks are monitored manually, leading to configuration complexity, human errors, faults, downtime risks, and time consumption. Network automation emerges as a practical solution by reducing administrative overhead and enabling reliable, scalable, and self-managing networks through scripting and standardized programming languages. This paper proposes a model for automated networks using Python-based methods, specifically Paramiko, Netmiko, and the network automation and programmability abstraction layer with multivendor support (NAPALM), to configure the enhanced interior gateway routing protocol (EIGRP) within the graphical network simulator-3(GNS3) environment. The performance of the automated network was evaluated using two scenarios: with threading and without threading. Key metrics included execution time, configuration accuracy, error rates, and resource utilization. Simulation results demonstrate that the automated approach significantly outperforms manual configuration. In addition, the automated model with threading outperformed the automated model without threading, achieving execution time reductions up to 67% and 100% configuration accuracy with zero errors. These findings underscore the effectiveness of the proposed system for automating complex network tasks in large-scale IoT deployments.
- Open Access
- 12 September 2022
- Published by Wiley in Journal of Sensors
- Vol. 2022, 1-11
Smart Garage Utilizing Internet of Things (IoT)
People in urban regions face a daily problem finding parking slot for their vehicles. So, this study develops a network architecture based on Internet of Things platform. A system improves the efficiency of the current cloud-based smart-parking system. This study suggested a system that assists users in automatically finding a free parking space at the lowest cost. With an application, a user can request to reserve a parking slot. The application moves a driver directly into the free slot in a garage. Also, it utilizes the distance and total number of free spaces in each garage to determine the user nearest parking slot and cost. The garage slot cost will be charged by user credit once the user entered the garage or reserved a parking slot through the application. The system proposed a novel system which picks up a parking slot, reserves, and pays for it through mobile application. The proposed system can easily be deployed in the actual world.
- 12 September 2022
- Published by Wiley in Journal of Sensors
- Vol. 2022, 1-11
Open AccessSmart Garage Utilizing Internet of Things (IoT)
People in urban regions face a daily problem finding parking slot for their vehicles. So, this study develops a network architecture based on Internet of Things platform. A system improves the efficiency of the current cloud-based smart-parking system. This study suggested a system that assists users in automatically finding a free parking space at the lowest cost. With an application, a user can request to reserve a parking slot. The application moves a driver directly into the free slot in a garage. Also, it utilizes the distance and total number of free spaces in each garage to determine the user nearest parking slot and cost. The garage slot cost will be charged by user credit once the user entered the garage or reserved a parking slot through the application. The system proposed a novel system which picks up a parking slot, reserves, and pays for it through mobile application. The proposed system can easily be deployed in the actual world.
- Open Access
- 27 January 2022
- Published by MDPI AG in Journal of Sensor and Actuator Networks
- Vol. 11 (1) , 9
Seamless Handover Scheme for MEC/SDN-Based Vehicular Networks
With the recent advances in the fifth-generation cellular system (5G), enabling vehicular communications has become a demand. The vehicular ad hoc network (VANET) is a promising paradigm that enables the communication and interaction between vehicles and other surrounding devices, e.g., vehicle-to-vehicle (V2V) and vehicle-to-everything (V2X) communications. However, enabling such networks faces many challenges due to the mobility of vehicles. One of these challenges is the design of handover schemes that manage the communications at the intersection of coverage regions. To this end, this work considers developing a novel seamless and efficient handover scheme for V2X-based networks. The developed scheme manages the handover process while vehicles move between two neighboring roadside units (RSU). The developed mechanism is introduced for multilane bidirectional roads. The developed scheme is implemented by multiple-access edge computing (MEC) units connected to the RSUs to improve the implementation time and make the handover process faster. The considered MEC platform deploys an MEC controller that implements a control scheme of the software-defined networking (SDN) controller that manages the network. The SDN paradigm is introduced to make the handover process seamless; however, implementing such a controlling scheme by the introduction of an MEC controller achieves the process faster than going through the core network. The developed handover scheme was evaluated over the reliable platform of NS-3, and the results validated the developed scheme. The results obtained are presented and discussed.
- 27 January 2022
- Published by MDPI AG in Journal of Sensor and Actuator Networks
- Vol. 11 (1) , 9
Open AccessSeamless Handover Scheme for MEC/SDN-Based Vehicular Networks
With the recent advances in the fifth-generation cellular system (5G), enabling vehicular communications has become a demand. The vehicular ad hoc network (VANET) is a promising paradigm that enables the communication and interaction between vehicles and other surrounding devices, e.g., vehicle-to-vehicle (V2V) and vehicle-to-everything (V2X) communications. However, enabling such networks faces many challenges due to the mobility of vehicles. One of these challenges is the design of handover schemes that manage the communications at the intersection of coverage regions. To this end, this work considers developing a novel seamless and efficient handover scheme for V2X-based networks. The developed scheme manages the handover process while vehicles move between two neighboring roadside units (RSU). The developed mechanism is introduced for multilane bidirectional roads. The developed scheme is implemented by multiple-access edge computing (MEC) units connected to the RSUs to improve the implementation time and make the handover process faster. The considered MEC platform deploys an MEC controller that implements a control scheme of the software-defined networking (SDN) controller that manages the network. The SDN paradigm is introduced to make the handover process seamless; however, implementing such a controlling scheme by the introduction of an MEC controller achieves the process faster than going through the core network. The developed handover scheme was evaluated over the reliable platform of NS-3, and the results validated the developed scheme. The results obtained are presented and discussed.