WDWei Du

Wei Du

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wei Du has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Flavonoids in Hawthorn and Vitamin C Prevents Hypertension in Rats Induced by Heat Exposure

    by Wei Du, Hong-Min Fan, Yu-Xin Zhang, Xiao-Hua Jiang, Yun Li

    Background: Excessive oxidative stress is associated with hypertension in professional high-temperature working conditions. Polyphenols exhibit a cardioprotective effect. Hawthorn contains high amounts of flavonoids, though its effect on hypertension protection has yet to be studied. This study aims to investigate this effect of extract of hawthorn (EH) or its combination with vitamin C (Vit. C) in rats induced by working under a hot environment. Methods: Forty-two male rats were randomly divided into a control group under normal temperature and six treatment groups exposed at 33 ± 1 °C along with 1 h of daily treadmill running. They were orally provided with water, Vit. C (14mg/kg), EH (125, 250, and 500 mg/kg), and EH500 + Vit. C, once a day for four weeks. Results: Both EH and Vit. C alone reduced the systolic and diastolic blood pressure of rats exposed to the heat environment; however, their joint supplementation completely maintained their blood pressure to the normal level throughout the experimental period. No morphological changes were found on the intima of aorta. Moreover, the co-supplementation of EH and Vit. C prevented the changes of heat exposure in inducing oxidative stress markers, such as glutathione peroxidase, catalase, total antioxidant capacity, and nitric oxide; the synergistic action was more effective than either individual treatment of EH and Vit. C. Furthermore, the administration of EH had more potent effects on increasing superoxide dismutase, IL-2, the 70 kilodalton heat shock proteins and high sensitivity C reactive protein, and decreasing serum malondialdehyde and lipofuscin in vascular tissue than those in Vit. C group. Conclusions: A strong synergistic effect of EH and Vit. C on the prevention of hypertension under heat exposure was established, as they inhibited the oxidative stress state. This study also sets up a novel intervention strategy in animal models for investigation on the early phases of hypertension induced by heat exposure.


  • Comparison of double intravenous vasopressor automated system using nexfin versus manual vasopressor bolus administration for maintenance of haemodynamic stability during spinal anaesthesia for caesarean delivery

    by Ban Leong Sng, Wei Du, Man Xin Lee, Farida Ithnin, Deepak Mathur, Wan Ling Leong, Rehena Sultana, Nian-Lin R. Han, Alex Tiong Heng Sia

    Hypotension is a common side effect of spinal anaesthesia during caesarean delivery and is associated with maternal and foetal adverse effects. We developed an updated double intravenous vasopressor automated (DIVA) system that administers phenylephrine or ephedrine based on continuous noninvasive haemodynamic monitoring using the Nexfin device. The aim of our present study is to compare the performance and reliability of the DIVA system against Manual Vasopressor Bolus administration. A randomised, double-blind controlled trial. Single-centre, KK Women's and Children's Hospital, Singapore. Two hundred and thirty-six healthy women undergoing elective caesarean delivery under spinal anaesthesia. The primary outcome was the incidence of maternal hypotension. The secondary outcome measures were reactive hypertension, total vasopressor requirement and maternal and neonatal outcomes. The DIVA group had a significantly lower incidence of maternal hypotension, with 39.3% (46 of 117) patients having any SBP reading less than 80% of baseline compared with 57.5% (65 of 113) in the manual vasopressor bolus group (P = 0.008). The DIVA group also had fewer hypotensive episodes than the manual vasopressor bolus group (4.67 versus 7.77%; P < 0.0001). There was no difference in the incidence of reactive hypertension or the total vasopressor requirement. The DIVA group had less wobble in system performance. Maternal and neonatal outcomes were similar. The DIVA system achieved better control of maternal blood pressure after spinal anaesthesia than manual vasopressor bolus administration. Clinicaltrials.gov identifier: NCT02277730.