YMYumi Mashimo

Yumi Mashimo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yumi Mashimo has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    22-gauge Co-Cr versus stainless-steel Franseen needles for endoscopic ultrasound-guided tissue acquisition in patients with solid pancreatic lesions

    by Yuki Tanisaka, Masafumi Mizuide, Akashi Fujita, Ryuhei Jinushi, Rie Shiomi, Takahiro Shin, Kei Sugimoto, Tomoaki Tashima, Yumi Mashimo, Shomei Ryozawa

    Background/Aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) using Franseen needles is reportedly useful for its high diagnostic yield. This study compared the diagnostic yield and puncturing ability of EUS-TA using 22-gauge cobalt-chromium (CO-Cr) needles with those of stainless-steel Franseen needles in patients with solid pancreatic lesions.Methods: Outcomes were compared between the 22-gauge Co-Cr Franseen needle (December 2019 to November 2020; group C) and stainless-steel needle (November 2020 to May 2022; group S).Results: A total of 155 patients (group C, 75; group S, 80) were eligible. The diagnostic accuracy was 92.0% in group C and 96.3% in group S with no significant intergroup differences (p=0.32). The rate of change in the operator (from training fellows to experts) was 20.0% (15/75) in group C and 7.5% (6/80) in group S. Stainless-steel Franseen needles showed less inter-operator difference than Co-Cr needles (p=0.03).Conclusions: Both Co-Cr and stainless-steel Franseen needles showed high diagnostic ability. Stainless-steel Franseen needles are soft and flexible; therefore, the range of puncture angles can be widely adjusted, making them suitable for training fellows to complete the procedure.


  • Endoscopic mucosal resection with over-the-scope clip (EMR-O) for colorectal tumors: A single-center case series

    by Takahiro Muramatsu, Tomoaki Tashima, Tsubasa Ishikawa, Yumi Mashimo, Shomei Ryozawa

    Background: We developed a new endoscopic resection method that combines endoscopic mucosal resection (EMR) with an over-the-scope clip (OTSC), termed EMR-O. In this study, we aimed to evaluate the short-term outcomes of EMR-O for colorectal tumors. Method: In total, 9 consecutive patients who underwent EMR-O from September 2017 and October 2022 were retrospectively enrolled. Patients' characteristics and treatment outcomes were evaluated. Result: The En bloc and R0 resection rates were 100% and 89%. The median resected specimen size was 16 (10-27) mm, with a median resected tumor size was 8 (5-17) mm. The median procedure time was 10 (7-15) min. There were no intraoperative or delayed perforation and postoperative bleeding. Discussion: Although EMR-O has limitations in target lesion size, it has the advantages of a short procedure time and the prevention of perforation.

  • Endoscopic ultrasound‑guided biliary drainage in patients with surgically altered anatomy: a systematic review and Meta‑analysis

    by Yuki Tanisaka, Masafumi Mizuide, Akashi Fujita, Ryuhei Jinushi, Rie Shiomi, Takahiro Shin, Dai Hirata, Rie Terada, Tomoaki Tashima, Yumi Mashimo, et al.

    Endoscopic retrograde cholangiopancreatography is technically challenging to perform in patients with surgically altered anatomy (SAA). For these patients, endoscopic ultrasound-guided biliary drai...


  • Open Access

    Balloon enteroscope-assisted endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy

    by Yuki Tanisaka, Masafumi Mizuide, Akashi Fujita, Tomoya Ogawa, Hiromune Katsuda, Yoichi Saito, Kazuya Miyaguchi, Ryuhei Jinushi, Rie Terada, Yuya Nakano, et al.

    Yuki Tanisaka*, Masafumi Mizuide, Akashi Fujita, Tomoya Ogawa, Hiromune Katsuda, Yoichi Saito, Kazuya Miyaguchi, Ryuhei Jinushi, Rie Terada, Yuya Nakano, Tomoaki Tashima, Yumi Mashimo, and Shomei Ryozawa. Int J Gastrointest Interv 2022;11:5-12. https://doi.org/10.18528/ijgii210058


  • A retrospective cohort study of factors influencing long procedure times in colorectal endoscopic submucosal dissection

    by Kazuya Miyaguchi, Tomoaki Tashima, Rie Terada, Ryuhei Jinushi, Yuya Nakano, Hiromune Katsuda, Tomoya Ogawa, Akashi Fujita, Yuki Tanisaka, Masafumi Mizuide, et al.

    To evaluate the outcomes and factors influencing colorectal endoscopic submucosal dissection (ESD) with a long procedure time. In this single-center, retrospective study, we included 1,100 patients with 1,199 lesions who underwent colorectal ESD between April 2016 and December 2020. ESD was performed using an advanced system knife for lesions >20 mm. An S-O clip was used as the traction device. The long-time group (LP; procedure time >120 min) and normal-time group (NP; procedure time <120 min) were compared. The procedure times were 166.86 and 44.72 min in the LP and NP groups, respectively. The completion rate was higher in the NP group (96.5% vs. 83.5%, p = .001); the completed lesions were resected en bloc. Multivariate analysis revealed 18.8% and 7.8% of submucosal fibrosis in the LP and NP groups, respectively (odds ratio [OR] = 2.410, p = .026). Compared to the NP group, the LP group presented larger maximum lesion sizes and higher rates of R1 resection, and traction device use. Time to introduction of traction device use was longer in the LP than in the NP group (126.05 vs. 21.72 min; p < .001). Fibrosis tends to occur cecal lesions (OR 2.436, p = .011) and laterally spreading tumor-non-granular-pseudo-depressed (LST-NG-PD) (OR 2.6181, p = .001). Lesion size and fibrosis were factors associated with a long procedure time in colonic ESD. For fibrotic lesions (LST-NG-PD and cecal lesions), it is necessary to consider early use of traction devices and advisable to plan a strategy for the use of traction devices.


  • Hazardous repeat bleeding after colorectal endoscopic submucosal dissection in a patient with immune thrombocytopenia: complete hemostasis using an over-the-scope clip

    by Kazuya Miyaguchi, Tomoaki Tashima, Kei Sugimoto, Yumi Mashimo, Hiroyuki Imaeda, Shomei Ryozawa

    A 76-year-old man diagnosed with early-stage colorectal cancer was referred to our hospital for endoscopic submucosal dissection (ESD). The patient had a low platelet count (31,000/µL) due to immune thrombocytopenia (ITP). The cancerous lesion was completely resected without any adverse events. A blood test performed 1 day post-ESD showed no progression of anemia and the initial postoperative course was uneventful. However, 7 days after ESD, dark red stools were observed, and we performed an emergency colonoscopy. We stopped the bleeding twice using hemoclips and hemostatic forceps. Since the patient’s platelet count remained below 50,000/µL, we started thrombopoietin receptor agonist treatment with eltrombopag (12.5 mg/day) for thrombocytopenia. Although the platelet count increased, the patient experienced rebleeding for the fourth time and underwent an emergency colonoscopy, during which we used an over-the-scope clip (OTSC) to achieve hemostasis. No rebleeding occurred after OTSC intervention, and the platelet count stabilized at approximately 50,000/µL. We discharged the patient on Day 34 after ESD. Although the guidelines do not specify a target platelet count for performing ESD, a platelet count < 50,000/µL should be considered low. Furthermore, an OTSC may be useful for treating intractable bleeding.