Shunta Sato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shunta Sato has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Sousuke Nakamura
Graduate School of Science and Engineering, Hosei University, Tokyo, Japan
1 shared publication- Sousuke Nakamura
Faculty of Science and Engineering, Hosei University, Tokyo, Japan
1 shared publication Yoshinori Tsuruda
Graduate School of Science and Engineering, Hosei University, Tokyo, Japan
1 shared publicationYuji Tanaka
Graduate School of Science and Engineering, Hosei University, Tokyo, Japan
1 shared publication
Latest Publications
- Open Access
Proposal of Wireless Charging Which Enables Magnetic Field Suppression at Foreign Object Location
In the wireless power transmission (WPT) to electric vehicles (EVs) in parking lots, there is a risk of abnormal heat generation due to the absorption of the magnetic field in metallic foreign objects. Accordingly, currently available products are equipped with a function that automatically halts power transmission when a metallic foreign object is detected. However, if possible, continuing power transmission while suppressing the magnetic field absorption may be an another solution. Therefore, this paper proposes a novel function which enables wireless power transmission with high efficiency while suppressing the magnetic field absorption of metallic foreign objects. In this study, it was assumed that a metallic foreign body was present in an arbitrary point in a two-dimensional plane and the power transmission was conducted by the phased array WPT. An algorithm using particle swarm optimization (PSO) to search for the optimal combination of the phase and amplitude of the coil input voltages together with coil arrangements, in terms of both magnetic field suppression and transmission efficiency, is proposed. The simulation was performed with the lower efficiency boundary set as 85% and the load power set as 11 kW, in reference to the SAE J2954 standard. As a result, it was confirmed that the magnetic field suppression effect increased in accordance with the increase in the number of transmission (Tx) coils, thus indicating the effectiveness of the proposed algorithm.
Open AccessProposal of Wireless Charging Which Enables Magnetic Field Suppression at Foreign Object Location
In the wireless power transmission (WPT) to electric vehicles (EVs) in parking lots, there is a risk of abnormal heat generation due to the absorption of the magnetic field in metallic foreign objects. Accordingly, currently available products are equipped with a function that automatically halts power transmission when a metallic foreign object is detected. However, if possible, continuing power transmission while suppressing the magnetic field absorption may be an another solution. Therefore, this paper proposes a novel function which enables wireless power transmission with high efficiency while suppressing the magnetic field absorption of metallic foreign objects. In this study, it was assumed that a metallic foreign body was present in an arbitrary point in a two-dimensional plane and the power transmission was conducted by the phased array WPT. An algorithm using particle swarm optimization (PSO) to search for the optimal combination of the phase and amplitude of the coil input voltages together with coil arrangements, in terms of both magnetic field suppression and transmission efficiency, is proposed. The simulation was performed with the lower efficiency boundary set as 85% and the load power set as 11 kW, in reference to the SAE J2954 standard. As a result, it was confirmed that the magnetic field suppression effect increased in accordance with the increase in the number of transmission (Tx) coils, thus indicating the effectiveness of the proposed algorithm.
- 18 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1555-1560
Basic Investigation on Wireless Power Transfer System via Magnetic Resonant Coupling with Magnetic Field Suppression at an Any Point
In recent years, attention has been drawn to wireless power transfer of an electric vehicle via magnetic resonance coupling as a transmission method. Although the wireless power transfer enables to reduce the risk of electric shock and the loss of time for connecting the power cable, there are problems that underlie in leakage of magnetic field generated along with the wireless power transfer, absorbed by surrounding objects. Therefore, in this paper, we investigated the number and allocation of the coils of the phased array coil which we believe to have the potential of suppressing the magnetic field absorption while maintaining the transmission efficiency. The optimization of the phased array coil arrangement and the phase and amplitude of the input voltage was done using the Particle Swarm Optimization (PSO). As a result, there were five variationsin the arrangement of the RX coil, and the most effectivemagnetic field suppression was achieved in the configurationwith two TX coils, and the magnetic field was suppressed by -83.4%, compared to the configuration of a general MRC-WPT.
- 18 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1555-1560
Basic Investigation on Wireless Power Transfer System via Magnetic Resonant Coupling with Magnetic Field Suppression at an Any Point
In recent years, attention has been drawn to wireless power transfer of an electric vehicle via magnetic resonance coupling as a transmission method. Although the wireless power transfer enables to reduce the risk of electric shock and the loss of time for connecting the power cable, there are problems that underlie in leakage of magnetic field generated along with the wireless power transfer, absorbed by surrounding objects. Therefore, in this paper, we investigated the number and allocation of the coils of the phased array coil which we believe to have the potential of suppressing the magnetic field absorption while maintaining the transmission efficiency. The optimization of the phased array coil arrangement and the phase and amplitude of the input voltage was done using the Particle Swarm Optimization (PSO). As a result, there were five variationsin the arrangement of the RX coil, and the most effectivemagnetic field suppression was achieved in the configurationwith two TX coils, and the magnetic field was suppressed by -83.4%, compared to the configuration of a general MRC-WPT.