JSJina Shim

Jina Shim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jina Shim has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Youngjin Lee

    Department of Radiological Science, Gachon University, 191, Hambangmoe-ro, Yeonsu-gu, Incheon 21936, Republic of Korea

    5 shared publications
  • Chae-Hyeon Song

    Department of Radiological Science, Gachon University, 191, Hambakmoero, Yeonsu-gu, Incheon 21936, Republic of Korea

    1 shared publication
  • Hajin Kim

    Department of Health Science, General Graduate School of Gachon University, 191, Hambangmoe-ro, Yeonsu-gu, Incheon 21936, Republic of Korea

    1 shared publication
  • Juho Park

    Department of Radiological Science, Gachon University, 191, Hambakmoe-ro, Yeonsu-gu, Incheon 21936, Republic of Korea

    1 shared publication
  • Kyu Bom Kim

    Department of Integrative Medicine, Major in Digital Healthcare, Yonsei University College of Medicine, Unju-ro, Gangman-gu, Seoul 06229, Korea

    1 shared publication
  • Kyuseok Kim

    Institute of Human Convergence Health Science, Gachon University, 191, Hambangmoe-ro, Yeonsu-gu, Incheon 21936, Republic of Korea

    1 shared publication

Latest Publications

  • Open Access

    Application and Optimization of a Fast Non-Local Means Noise Reduction Algorithm in Pediatric Abdominal Virtual Monoenergetic Images

    by Hajin Kim, Juho Park, Jina Shim, Youngjin Lee

    In this study, we applied and optimized a fast non-local means (FNLM) algorithm to reduce noise in pediatric abdominal virtual monoenergetic images (VMIs). To analyze various contrast agent concentrations, we produced contrast agent concentration samples (20, 40, 60, 80, and 100%) and inserted them into a phantom model of a one-year-old pediatric patient. Single-energy computed tomography (SECT) and dual-energy computed tomography (DECT) images were acquired from the phantom, and 40 kilo-electron-volt (keV) VMI was acquired based on the DECT images. For the 40 keV VMI, the smoothing factor of the FNLM algorithm was applied from 0.01 to 1.00 in increments of 0.01. We derived the optimized value of the FNLM algorithm based on quantitative evaluation and performed a comparative assessment with SECT, DECT, and a total variation (TV) algorithm. As a result of the analysis, we found that the average contrast to noise ratio (CNR) and coefficient of variation (COV) of each concentration were most improved at a smoothing factor of 0.02. Based on these results, we derived the optimized smoothing factor value of 0.02. Comparative evaluation shows that the optimized FNLM algorithm improves the CNR and COV results by approximately 3.14 and 2.45 times, respectively, compared with the DECT image, and the normalized noise power spectrum result shows a 10−1 mm2 improvement. The main contribution of this study is to demonstrate the effectiveness of an optimized FNLM algorithm in reducing noise in pediatric abdominal VMI, allowing high-quality images to be acquired while reducing contrast dose. This advancement has significant implications for minimizing the risk of contrast-induced toxicity, especially in pediatric patients. Our approach addresses the problem of limited datasets in pediatric imaging by providing a computationally efficient noise reduction technique and highlights the clinical applicability of the FNLM algorithm. In addition, effective noise reduction enables high-contrast imaging with minimal radiation and contrast exposure, which is expected to be suitable for repeat CT examinations of pediatric liver cancer patients and other abdominal diseases.


  • Open Access

    Evidence-Based Investigation of Coronary Calcium Score in Cardiac Computed Tomography

    by Jina Shim, Kyuseok Kim, Youngjin Lee

    This study aimed to verify whether increased body mass index (BMI) increases the noise in computed tomography (CT) images due to heightened effective thickness, impacting calcium scores. Calcium scores were measured in 30 sets of images from normal weight patients. Calcium scores were also measured in 30 sets of images from hypothetical overweight and obese patients, generated by extracting the noise from overweight and obese patients, respectively, and inserting it into the images of normal weight patients. In addition, a phantom study was performed using three calcium phantoms with intensities below the threshold of 130 Hounsfield units and three calcium phantoms with intensities above this threshold. Calcium scores were measured in the absence and presence of a bolus at the heart level to simulate an obese patient. All calcium scores were measured by three radiologists. In the patient study, the total calcium scores of the hypothetical overweight and hypothetical obese groups were 14.93% (p = 0.014) and 22.19% (p = 0.012) higher than those of the normal weight group. In the phantom study, the total calcium score of the six calcium phantoms without a bolus was 1.61% higher at a tube voltage of 120 kV than at 100 kV, and 12.06% higher at a slice thickness of 1 mm than at 3 mm. The total calcium score of the six calcium phantoms with a bolus was 0.13% higher at a tube voltage of 120 kV than at 100 kV, and 14.76% higher at a slice thickness of 1 mm than at 3 mm. These results can be used as a reference to train automated calcium scoring programs on effective thickness through deep learning to reduce calcium score errors caused by increased BMI.


  • Open Access

    No-Reference-Based and Noise Level Evaluations of Cinematic Rendering in Bone Computed Tomography

    by Jina Shim, Youngjin Lee

    Cinematic rendering (CR) is a new 3D post-processing technology widely used to produce bone computed tomography (CT) images. This study aimed to evaluate the performance quality of CR in bone CT images using blind quality and noise level evaluations. Bone CT images of the face, shoulder, lumbar spine, and wrist were acquired. Volume rendering (VR), which is widely used in the field of diagnostic medical imaging, was additionally set along with CR. A no-reference-based blind/referenceless image spatial quality evaluator (BRISQUE) and coefficient of variation (COV) were used to evaluate the overall quality of the acquired images. The average BRISQUE values derived from the four areas were 39.87 and 46.44 in CR and VR, respectively. The difference between the two values was approximately 1.16, and the difference between the resulting values increased, particularly in the bone CT image, where metal artifacts were observed. In addition, we confirmed that the COV value improved by 2.20 times on average when using CR compared to VR. This study proved that CR is useful in reconstructing bone CT 3D images and that various applications in the diagnostic medical field will be possible.


  • Open Access

    Usefulness Evaluation for Nonlocal Means Algorithm in Low-Dose Computed Tomography with Various Iterative Reconstruction Intensities and Kernels: A Pilot Study

    by Chaehyeon Song, Yubin Jin, Jina Shim, Seong-Hyeon Kang, Youngjin Lee

    The aim of this study was to evaluate the application feasibility of the nonlocal means (NLM) noise reduction algorithm in low-dose computed tomography (CT) images using an advanced modeled iterative reconstruction (ADMIRE) iterative reconstruction technique-based tin filter with various applied parameters. Low-dose CT images were based on high pitch and tin filters and acquired using slices of the aortic arch, the four chambers of the heart, and the end of the heart. Intensities A2 and A3 as well as kernels B40 and B59 were used as the parameters for the ADMIRE technique. The NLM denoising algorithm was modeled based on the principle of weighting between pixels; the contrast-to-noise ratio (CNR), edge rise distance (ERD), and blind/referenceless image spatial quality evaluator (BRISQUE) were used as image quality evaluation parameters. The CNR result was the highest, with an average of 43.51 in three slices when the proposed NLM denoising algorithm was applied to CT images acquired using the ADMIRE intensity 2 and B59 kernel. The ERD results were similar to those obtained using the ADMIRE intensity 2 and B59 kernel in the CT image acquired using the proposed method. In addition, BRISQUE, which can evaluate the overall image quality, showed a similar trend to the ERD results. In conclusion, the NLM noise reduction algorithm is expected to maximize image quality by preserving efficient edge information while improving noise characteristics in low-dose CT examinations.

  • Open Access

    Metallic Component Preserving Algorithm Based on the Cerebral Computed Tomography Angiography in Aneurysm Surgery

    by Jina Shim, Su Hwan Lee, Youngjin Lee, Kyu Bom Kim, Kyuseok Kim

    The purpose of this study was to investigate the viability of the proposed method in preventing the loss of metallic components including the clip and coil in cerebral computed tomography angiography (CTA). Forty patients undergoing surgery for aneurysms carried metallic materials. The proposed method is based on conventional bone subtraction CTA (BS-CTA) system. Briefly, the position of metal components was determined using the threshold value and a region of interest (ROI). An appropriate threshold was used to separate the background from the target materials based on the Otsu method. A three-dimensional (3D) rendering was performed from the proposed BS-CTA data carrying the extracted target information. The accuracy of clip and coil region measured using the dice similarity coefficient (DSC) and bidirectional Hausdorff distance (HD) is reported. The metallic components of the proposed BS-CTA were significantly visualized in various patient cases. Quantitative evaluation using the proposed method is based on the mean DSC of 0.93 with a standard deviation (SD) of ±0.05 (e.g., maximum value = 0.99, minimum value = 0.75, 95% confidence interval (CI) = 0.91 to 0.95, and all p < 0.05). The mean HD was 1.50 voxels with an SD of ± 0.58 (e.g., maximum value = 5.95, minimum value = 0.12, 95% CI = 1.10 to 1.90, and all p < 0.05). The proposed method demonstrates effective segmentation of the metallic component and application to the existing conventional BS-CTA system.