ZGZhijun Gu

Zhijun Gu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhijun Gu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Micromechanical Transmitter with Only One BAW Magneto-Electric Antenna

    by Si Chen, Junru Li, Yang Gao, Jianbo Li, Hongmei Dong, Zhijun Gu, Wanchun Ren

    Implantable medical devices have been facing the severe challenge of wireless communication for a long time. Acoustically actuated magnetoelectric (ME) transducer antennas have attracted lots of attention due to their miniaturization, high radiation efficiency and easy integration. Here, we fully demonstrate the possibility of using only one bulk acoustic wave (BAW) actuated ME transducer antenna (BAW ME antenna) for communication by describing the correspondence between the BAW ME antenna and components of the traditional transmitter in detail. Specifically, we first demonstrate that the signal could be modulated by applying a direct current (DC) magnetic bias and exciting different resonance modes of the BAW ME antenna with frequencies ranging from medium frequency (MF) (1.5 MHz) to medium frequency (UHF) (2 GHz). Then, two methods of adjusting the radiation power of the BAW ME antenna are proposed to realize signal amplification, including increasing the input voltage and using higher order resonance. Finally, a method based on electromagnetic (EM) perturbation is presented to simulate the transmission process of the BAW ME antenna via the finite element analysis (FEA) model. The simulation results match the radiation pattern of magnetic dipoles perfectly, which verifies both the model and our purpose.


  • Open Access

    Design and Optimization of a BAW Magnetic Sensor Based on Magnetoelectric Coupling

    by Wanchun Ren, Jintong Li, Guo Liu, Jiarong Chen, Si Chen, Zhijun Gu, Jianbo Li, Junru Li, Yang Gao

    Magnetic sensors actuated by bulk acoustic wave (BAW) have attracted extensive attention due to the fact of their high sensitivity, GHz-level high frequency, and small size. Different from previous studies, suppression of energy loss and improvement in energy conversion efficiency of the BAW magnetoelectric (ME) sensor were systematically considered during the device design in this work. Finite element analysis models of material (magnetic composite), structure (ME heterostructure), and device (BAW ME magnetic sensor) were established and analyzed in COMSOL software. Additionally, the magnetic composite was prepared by radio frequency magnetron sputtering, and its soft magnetism was characterized by magnetic hysteresis loop and surface roughness. The research results demonstrate that after inserting four layers of 5 nm Al2O3 films, a performance of 86.7% eddy current loss suppression rate, a less than 1.1% magnetostriction degradation rate, and better soft magnetism were achieved in 600 nm FeGaB. Furthermore, compared with other structures, the two-layer piezomagnetic/piezoelectric heterostructure had a better ME coupling performance. Eventually, the design of the BAW ME magnetic sensor was optimized by the resonance-enhanced ME coupling to match the resonance frequency between the magnetic composite and the BAW resonator. When a 54,500 A/m direct current bias magnetic field was applied, the sensor worked at the first-order resonance frequency and showed good performance. Its linearity was better than 1.30%, the sensitivity was as high as 2.33 μmV/A, and the measurement range covered 0–5000 A/m.