Bowen Tian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bowen Tian has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Chifu Yang
School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, China
2 shared publications - Feng Jiang
School of Artificial Intelligence, Nanjing University of Information Science and Technology, Nanjing 210044, China
2 shared publications - Tao Yang
School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, China
2 shared publications - Hao Guo
Faculty of Computing, Harbin Institute of Technology, Harbin, China
1 shared publication - Jiayi Yu
Zhongnan University of Economics and Law
1 shared publication - Zhen Ding
School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, China
1 shared publication
Latest Publications
- Open Access
Design and Evaluation of a Novel Variable Stiffness Hip Joint Exoskeleton
An exoskeleton is a wearable device with human–machine interaction characteristics. An ideal exoskeleton should have kinematic and kinetic characteristics similar to those of the wearer. Most traditional exoskeletons are driven by rigid actuators based on joint torque or position control algorithms. In order to achieve better human–robot interaction, flexible actuators have been introduced into exoskeletons. However, exoskeletons with fixed stiffness cannot adapt to changing stiffness requirements during assistance. In order to achieve collaborative control of stiffness and torque, a bionic variable stiffness hip joint exoskeleton (BVS-HJE) is designed in this article. The exoskeleton proposed in this article is inspired by the muscles that come in agonist–antagonist pairs, whose actuators are arranged in an antagonistic form on both sides of the hip joint. Compared with other exoskeletons, it has antagonistic actuators with variable stiffness mechanisms, which allow the stiffness control of the exoskeleton joint independent of force (or position) control. A BVS-HJE model was established to study its variable stiffness and static characteristics. Based on the characteristics of the BVS-HJE, a control strategy is proposed that can achieve independent adjustment of joint torque and joint stiffness. In addition, the variable stiffness mechanism can estimate the output force based on the established mathematical model through an encoder, thus eliminating the additional force sensors in the control process. Finally, the variable stiffness properties of the actuator and the controllability of joint stiffness and joint torque were verified through experiments.
Open AccessDesign and Evaluation of a Novel Variable Stiffness Hip Joint Exoskeleton
An exoskeleton is a wearable device with human–machine interaction characteristics. An ideal exoskeleton should have kinematic and kinetic characteristics similar to those of the wearer. Most traditional exoskeletons are driven by rigid actuators based on joint torque or position control algorithms. In order to achieve better human–robot interaction, flexible actuators have been introduced into exoskeletons. However, exoskeletons with fixed stiffness cannot adapt to changing stiffness requirements during assistance. In order to achieve collaborative control of stiffness and torque, a bionic variable stiffness hip joint exoskeleton (BVS-HJE) is designed in this article. The exoskeleton proposed in this article is inspired by the muscles that come in agonist–antagonist pairs, whose actuators are arranged in an antagonistic form on both sides of the hip joint. Compared with other exoskeletons, it has antagonistic actuators with variable stiffness mechanisms, which allow the stiffness control of the exoskeleton joint independent of force (or position) control. A BVS-HJE model was established to study its variable stiffness and static characteristics. Based on the characteristics of the BVS-HJE, a control strategy is proposed that can achieve independent adjustment of joint torque and joint stiffness. In addition, the variable stiffness mechanism can estimate the output force based on the established mathematical model through an encoder, thus eliminating the additional force sensors in the control process. Finally, the variable stiffness properties of the actuator and the controllability of joint stiffness and joint torque were verified through experiments.
- Open Access
Study on the Control Method of Knee Joint Human–Exoskeleton Interactive System
The advantages of exoskeletons based on the Bowden cable include being lightweight and flexible, thus being convenient in assisting humans. However, the performance of an exoskeleton is limited by the structure and human–exoskeleton interaction, which is analyzed from the established mathematical model of the human–exoskeleton system. In order to improve the auxiliary accuracy, corresponding control methods are proposed. The disturbance observer is designed to compensate for disturbances and parameter perturbations in the inner loop. The human–exoskeleton interaction feedforward model is integrated into the admittance control, which overcomes the limitation of the force loading caused by the friction of the Bowden cable and the change in stiffness of the human–exoskeleton interaction. Furthermore, an angle prediction method using the encoder as the signal source is designed to reduce the disturbance of the force loading caused by human motion. Finally, the effectiveness of the design method proposed in this paper is verified through experiments.
Open AccessStudy on the Control Method of Knee Joint Human–Exoskeleton Interactive System
The advantages of exoskeletons based on the Bowden cable include being lightweight and flexible, thus being convenient in assisting humans. However, the performance of an exoskeleton is limited by the structure and human–exoskeleton interaction, which is analyzed from the established mathematical model of the human–exoskeleton system. In order to improve the auxiliary accuracy, corresponding control methods are proposed. The disturbance observer is designed to compensate for disturbances and parameter perturbations in the inner loop. The human–exoskeleton interaction feedforward model is integrated into the admittance control, which overcomes the limitation of the force loading caused by the friction of the Bowden cable and the change in stiffness of the human–exoskeleton interaction. Furthermore, an angle prediction method using the encoder as the signal source is designed to reduce the disturbance of the force loading caused by human motion. Finally, the effectiveness of the design method proposed in this paper is verified through experiments.