FOFeifan Ouyang

Feifan Ouyang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Feifan Ouyang has a total of 268 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analgosedation for catheter ablation in deep sedation: comparison between cryoballoon and pulsed field ablation

    by Moritz Nies, Laura Rottner, Ingrid Unruh, Julius Obergassel, Jan Rieß, Niklas Schenker, Djemail Ismaili, Maria Luisa Benesch Vidal, Dominik Christmann, Johanna Skibowski, et al.

  • Open Access

    Electromagnetic interference during epicardial ablation in a patient with an extravascular implantable cardioverter-defibrillator and arrhythmogenic right ventricular cardiomyopathy: a case report

    by Matthieu Proust, Feifan Ouyang, Alexander Breitenstein, Firat Duru, Ardan M Saguner

    Background: Arrhythmogenic cardiomyopathy (ACM) is an inherited disease characterized by fibrofatty replacement, most often involving the right ventricle but potentially affecting the left or both ventricles. It predisposes to severe ventricular arrhythmia (VA). Differentiating ACM from athlete’s heart remains difficult, particularly in gene-elusive patients. Implantable cardioverter-defibrillators (ICDs) and catheter ablation are key therapeutic options. Epicardial ablation may be required for VA circuits inaccessible in an endocardial approach, but data on its feasibility in patients with extravascular ICD (EV-ICD) featuring a retrosternal lead is scarce. Case summary: A 42-year-old male athlete was admitted for syncope due to sustained ventricular tachycardia (VT) during exertion. Cardiac magnetic resonance imaging (CMR) showed a dilated right ventricle (RV) with wall akinesia and fibrosis involving the RV outflow tract. Genetic testing was negative. The diagnosis of borderline gene-elusive ACM was made. An EV-ICD was implanted for secondary prevention. Recurrent sustained VT prompted endocardial and epicardial ablation, which was feasible and successful, but radiofrequency energy application was hampered close to the retrosternal lead due to electromagnetic interference. Conclusion: This case highlights the diagnostic and therapeutic challenges of ACM in athletes. Epicardial ablation is feasible even with an EV-ICD, although electromagnetic interference may complicate ablation near the lead. High-level endurance exercise can induce ACM-like remodelling, creating phenotypic overlap with gene-elusive ACM. Early recognition, tailored ablation strategies, and appropriate device therapy are essential for the management of these patients.

  • Open Access

    Conflicting invasive electrophysiological study results in a suspected fasciculoventricular pathway: a case report

    by Alexander Welcker, Djemail Ismaili, Andreas Rillig, Feifan Ouyang

    Background: Fasciculoventricular pathways (FVPs) are variants of pre-excitation syndrome with uncertain prevalence in the human heart. This case report presents findings from an invasive electrophysiological study (EPS) that mostly fulfil the established diagnostic criteria for FVP, but also exhibit atypical features, highlighting diagnostic ambiguity in clinical practice. Case summary: A 23-year-old patient presented with a history of brief, weekly episodes of palpitations. The resting surface ECG demonstrated a pre-excitation pattern suggestive of either a parahisian or fasciculoventricular pathway. The EPS findings were largely consistent with a FVP. During junctional beats, we observed a loss of pre-excitation and normalization of HV-interval. No tachycardia was inducible, and there was no evidence of retrograde conduction via an accessory pathway. Discussion: Three potential anatomical locations of the upper FVP take-off side were considered: (i) a single FVP originating from the lower part of the His-bundle or (ii) a single FVP originating close to the upper, junctional part of the His-bundle or even from the distal part of the AV-node and (iii) the presence of an additional second accessory pathway. Based on the above-mentioned evidence, the second anatomical location of the upper FVP-insertion was most likely, differing from previous findings of FVP in the literature. A conservative, observational management strategy was adopted. Current diagnostic criteria for FVP are based on retrospective studies and case reports, lacking prospective validation. This case underscores the need for further research to refine the diagnostic approach to FVP and improve risk stratification in such patients.

  • Open Access

    Left Atrial Appendage Thrombus in Patients With Hypertrophic Cardiomyopathy and Atrial Fibrillation: Prevalence and Risk Factors

    by Leon Dinshaw, Benjamin Lippmann, Ruben Schleberger, Laura Rottner, Fabian Moser, Jannis Dickow, Paula Münkler, Marc D. Lemoine, Henrik Schneider, Bruno Reißmann, et al.

    Background: Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM) and increases stroke risk, primarily due to thromboembolism from the left atrial appendage (LAA). Oral anticoagulation (OAC) is recommended, but data on LAA thrombus (LAAT) in HCM and AF are limited. The current study aimed to assess LAAT prevalence in patients with HCM and AF. Methods: We retrospectively analyzed 170 patients with HCM and AF (mean age, 67.7±12.4 years; 57.1% men) who underwent at least one transesophageal echocardiogram (TEE) during a median follow‐up of 41.5 months (interquartile range, 15–77 months). Results: At the time of TEE, 147 (86.5%) patients were undergoing OAC, with 52 (30.6%) taking vitamin K antagonists and 95 (55.9%) taking non–vitamin K antagonist oral anticoagulants. LAAT was found in 36 patients (21.2%), with prevalence rates of 23.1% (n=12) in vitamin K antagonist users, 16.8% (n=16) in non–vitamin K antagonist oral anticoagulant users, and 34.8% (n=8) in those without OAC. Non–vitamin K antagonist oral anticoagulant use was associated with a significant LAAT risk reduction compared with no OAC (odds ratio, 0.20 [95% CI, 0.05–0.73]; P =0.02). Decreased LAA flow velocity ( P <0.001) was independently linked to LAAT. Conclusions: LAAT is common in patients with HCM and AF, even among those receiving OAC. Reduced LAA flow velocity may increase thrombus risk. TEE should be considered before rhythm‐control strategies, even in patients with HCM receiving anticoagulation, to minimize thromboembolic complications.


  • Open Access

    Long-term outcome and predictors for recurrence after medical and interventional treatment of arrhythmias at the UniverSity Heart CenTer Hamburg (TRUST): design and patient profile snapshot of a prospective clinical cohort study

    by Julius Obergassel, Jan Leon Rieß, Sandro Jaeckle, Silke van Elferen, Moritz Nies, Niklas Schenker, Marc Daniel Lemoine, Alexander Welcker, Shinwan Kany, Laura Rottner, et al.

    Aims: Optimal outcomes for patients with cardiac arrhythmias can be achieved through multimodal therapy including lifestyle support, medication, and interventions. Planning of these therapy concepts requires a detailed understanding of phenotypes, responses to therapies, and outcomes. Objective: The prospective Long-term Outcome and Predictors for Recurrence after Medical and Interventional Treatment of Arrhythmias at the University Heart Center Hamburg (TRUST) combines deep phenotypic, procedural, and follow-up information in a contemporary cohort of patients with cardiac arrhythmias. Methods and results: TRUST is an investigator-initiated, prospective, cohort study enrolling consecutive patients at the UHZ Hamburg. Comprehensive baseline work-up, imaging, and biobanking at baseline is combined with follow-up using a combination of in-person visits, online questionnaires, and remote rhythm-monitoring. Enrolment started in March 2021 and is ongoing. This paper describes the design and the clinical characteristics of the first 1500 enrolled patients with verified baseline datasets (562 women (37%), median age 64 (IQR 55, 74) years). Overall, 1077/1500 patients (71%) were seen for atrial fibrillation, 161/1500 (11%) for ventricular tachycardia and premature ventricular complexes, 239/1500 (16%) for supraventricular tachycardia, and 23/1500 (2%) patients for other reasons. Ablations, rhythm surgery, or invasive procedures were performed in 1363/1500 (91%) within 1 month after inclusion. Conclusion: This snapshot of the first 1500 patients enrolled in TRUST illustrates current characteristics and comorbidity burden in patients undergoing arrhythmia treatment. This rich data set will provide information on treatment patterns, detailed phenotypes, and follow-up, offering insights into the natural progression and treatment responses of arrhythmias in routine care.


  • Open Access

    Pulsed Field Ablation Using a Novel Biphasic Catheter vs Thermal Ablation for Paroxysmal Atrial Fibrillation

    by Weidong Lin, Huimin Chu, Chuangshi Wang, Dong Chang, Xiaomeng Yin, Yuegang Wang, Chenyang Jiang, Yizhou Xu, Qiwei Liao, Jian Yang, et al.


  • Open Access

    General anaesthesia and deep sedation for monopolar pulsed field ablation using a lattice-tip catheter combined with a novel three-dimensional mapping system

    by Andreas Rillig, Jun Hirokami, Fabian Moser, Stefano Bordignon, Laura Rottner, Tohoku Shota, Ilaria My, Andrea Urbani, Marc Lemoine, Joseph Kheir, et al.

    Aims: A novel three-dimensional mapping platform combined with a lattice-tip catheter that can toggle between monopolar pulsed field ablation (PFA) and radiofrequency energy delivery was recently launched. So far, the system was predominantly applied in general anaesthesia (GA), not in deep sedation. Methods and results: Patients with symptomatic paroxysmal or persistent atrial fibrillation (AF) were enrolled, and pulmonary vein isolation (PVI) and ablation of additional linear lesion sets were performed either in GA or in deep sedation. Pulsed field ablation was applied exclusively to perform ipsilateral PVI. A total of 63 patients (35% female, 75% persistent AF, mean age 64 ± 9 years) were included in the analysis with 23 patients treated in GA and 40 patients in deep sedation. Acute efficacy was comparable in both groups with a PVI rate of 100%. Additional 74 lesion sets were performed in the total cohort. Mean procedure and lab occupancy time in the GA and deep sedation group was 96 ± 24 min vs. 100 ± 23 min (P = 0.52) and 165 ± 40 min vs. 131 ± 35 min (P = 0.0008). Mean dose area product was 489 (216;1093) vs. 452 (272;882) cGycm2 in the GA and the deep sedation group (P = 0.82). There was one conversion from deep sedation to GA. There were no map shifts observed in any group. Pericardial tamponade occurred in one patient of the deep sedation group. Conclusion: The use of a novel ablation platform in conjunction with a lattice-tip catheter in deep sedation is feasible, effective, and associated with significantly shorter lab occupancy time when compared with GA.


  • Unexpected transient atrioventricular block and slow junctional rhythm using pulsed field ablation for slow pathway modification: Excited or cautious for ablators

    by Caijie Shen, Rong Bai, Zhenyu Jia, Mingjun Feng, Yibo Yu, Xianfeng Du, Guohua Fu, Tao Wu, Yongxing Jiang, He Jin, et al.


  • Open Access

    Atrial tachyarrhythmia prevention by Shensong Yangxin after catheter ablation for persistent atrial fibrillation: the SS-AFRF trial

    by He Huang, Yu Liu, Wei Shuai, Chenyang Jiang, Menghe Zhang, Xiufen Qu, Wenqing Zheng, Hao Yang, Fan Liu, Bo Yu, et al.

    Despite advances in technology and techniques, the recurrence rate of persistent atrial fibrillation (AF) following catheter ablation remains high. The Shensong Yangxin (SSYX) capsule, a renowned traditional Chinese medicine formula, is used in the treatment of cardiac arrhythmias. This trial aimed to investigate whether the SSYX can improve clinical outcomes in patients who have undergone catheter ablation for persistent AF. A multi-centre, randomized, double-blind, placebo-controlled clinical trial was conducted at 66 centres in China among 920 patients with persistent AF undergoing first ablation. Participants were randomized to oral SSYX, 1.6 g (.4 g/granule) thrice daily (n = 460), or matched placebo (n = 460) for 12 months. The primary endpoint was recurrent atrial tachyarrhythmias lasting for ≥30 s following a blanking period of 3 months. Secondary endpoints included time to first documented atrial tachyarrhythmias, AF burden, cardioversion, stroke/systemic embolism, changes in echocardiographic parameters, and quality-of-life (QoL) score. Analyses were performed according to the intention-to-treat principle. A total of 920 patients underwent randomization (460 assigned to SSYX group and 460 assigned to placebo group). During the follow-up of 12 months, patients assigned to SSYX had a higher event-free rate from recurrent atrial tachyarrhythmias when compared with the placebo group (12-month Kaplan–Meier event-free rate estimates, 85.5% and 77.7%, respectively; hazard ratio, .6; 95% confidence interval .4–.8; P = .001). Patients assigned to receive SSYX had a better QoL score at 12 months compared to those randomized to placebo. There was no significant difference in the incidence of serious adverse events between the two groups. Treatment with SSYX following radiofrequency catheter ablation for persistent AF reduced the incidence of recurrent atrial tachyarrhythmias and led to clinically significant improvements in QoL during a 12-month follow-up in a Chinese population. A total of 920 Chinese patients with persistent AF undergoing first ablation were randomized to oral SSYX or matched placebo for 12 months. The recurrence of atrial arrhythmia (left), Kaplan–Meier curves depicting the time to the first recurrence of atrial arrhythmia after the 3-month blanking period (middle), and quality of life at 12-month follow-up (right) were evaluated. SSYX, Shensong Yangxin; CI, confidence interval; AF, atrial fibrillation; RD, rate difference; HR, hazard ratio.


  • Open Access

    Pulsed-field- vs. cryoballoon-based pulmonary vein isolation: lessons from repeat procedures

    by Marc D Lemoine, Julius Obergassel, Sandro Jaeckle, Moritz Nies, Sophia Taraba, Celine Mencke, Jan Rieß, Ilaria My, Laura Rottner, Fabian Moser, et al.

    Pulsed-field ablation (PFA) is an emerging technology to perform pulmonary vein isolation (PVI). Initial data demonstrated high safety and efficacy. Data on long-term PVI durability and reconduction patterns in comparison to established energy sources for PVI are scarce. We compare findings in repeat ablation procedures after a first PFA to findings in repeat ablation procedures after a first cryoballoon ablation (CBA) based PVI. A total of 550 consecutively enrolled patients underwent PFA or CBA index PVI. Repeat ablations in patients with symptomatic atrial arrhythmia recurrences were analysed. A total of 22/191 (12%) patients after index PFA-PVI and 44/359 (12%) after CBA-PVI underwent repeat ablation. Reconduction of any pulmonary vein (PV) was detected by multipolar spiral mapping catheter at each PV with careful evaluation of PV potentials and by 3D-mapping in 16/22 patients (73%) after PFA-PVI and in 33/44 (75%) after CBA-PVI (P = 1.000). Of 82 initially isolated PVs after PFA-PVI, 31 (38%) were reconducting; of 169 isolated PVs after CBA-PVI, 63 (37%) were reconducting (P = 0.936). Clinical atrial tachycardia occurred similarly in patients after PFA (5/22; 23%) and CBA (7/44; 16%; P = 0.515). Roof lines were set more often after PFA- (8/22; 36%) compared with CBA-PVI (5/44; 11%; P = 0.023). Repeat procedure duration [PFA: 87 (76, 123) min; CBA: 93 (75, 128) min; P = 0.446] was similar and fluoroscopy time [PFA: 11 (9, 14) min; CBA: 11 (8, 14) min; P = 0.739] equal between groups at repeat ablation. During repeat ablation after previous PFA- or CBA-based PVI, electrical PV-reconduction rates and patterns were similar.