Giada Remia
Giada Remia has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Serena Summa
Marche Polytechnic University
7 shared publications - Costanzo Di Perna
Università Politecnica delle Marche
5 shared publications - Francesca Stazi
Università Politecnica delle Marche
5 shared publications - Ambra Sebastianelli
Industrial Engineering and Mathematical Sciences Department, Università Politecnica delle Marche, via Brecce Bianche 1, 60131 Ancona, Italy
1 shared publication C. Di Perna
1 shared publicationCostanzo Di Perna
1 shared publication
Latest Publications
- 7 March 2024
- Published by Springer Nature
- p. 109-117
Educational Buildings: Analysis of IAQ as a Function of Occupant Behavior and Mechanical Ventilation Systems
- 7 March 2024
- Published by Springer Nature
- p. 109-117
Educational Buildings: Analysis of IAQ as a Function of Occupant Behavior and Mechanical Ventilation Systems
- Open Access
- 1 December 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2648 (1) , 012030
Monitoring and analysis of environmental and IAQ conditions in classrooms with controlled mechanical ventilation
Following the health emergency from COVID-19, indoor air quality control has become of paramount importance, especially inside school buildings. For this reason, in 2021, the Marche region proposed and implemented an extraordinary intervention for the safe conduct of educational activities through the installation in classrooms of controlled mechanical ventilation systems aimed at air exchange. This type of system has been installed in more than 1,200 classrooms belonging to about 130 schools throughout the Marche region. This intervention made it possible to carry out a robust experimental measurement campaign on a significant number of classrooms where controlled mechanical ventilation systems were installed. Specifically, the work proposes a replicable measurement and analysis methodology for classrooms, with the aim of monitoring thermo-hygrometric and air quality conditions for environmental comfort. Thus, the research aims to implement knowledge on environmental comfort in classrooms equipped with controlled mechanical ventilation systems. The proposed measurements and analyses cover the most important environmental variables, i.e., air temperature, relative humidity, and CO2 concentration. In addition, measurements regarding system ventilation flow rates, smoke tests and evaluations of the permeability of classrooms.
- 1 December 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2648 (1) , 012030
Open AccessMonitoring and analysis of environmental and IAQ conditions in classrooms with controlled mechanical ventilation
Following the health emergency from COVID-19, indoor air quality control has become of paramount importance, especially inside school buildings. For this reason, in 2021, the Marche region proposed and implemented an extraordinary intervention for the safe conduct of educational activities through the installation in classrooms of controlled mechanical ventilation systems aimed at air exchange. This type of system has been installed in more than 1,200 classrooms belonging to about 130 schools throughout the Marche region. This intervention made it possible to carry out a robust experimental measurement campaign on a significant number of classrooms where controlled mechanical ventilation systems were installed. Specifically, the work proposes a replicable measurement and analysis methodology for classrooms, with the aim of monitoring thermo-hygrometric and air quality conditions for environmental comfort. Thus, the research aims to implement knowledge on environmental comfort in classrooms equipped with controlled mechanical ventilation systems. The proposed measurements and analyses cover the most important environmental variables, i.e., air temperature, relative humidity, and CO2 concentration. In addition, measurements regarding system ventilation flow rates, smoke tests and evaluations of the permeability of classrooms.
- Open Access
- 29 April 2023
- Published by Elsevier in Energy and Buildings
- Vol. 292
Experimental and numerical study on a new thermal masonry block by comparison with traditional walls
- 29 April 2023
- Published by Elsevier in Energy and Buildings
- Vol. 292
Open AccessExperimental and numerical study on a new thermal masonry block by comparison with traditional walls
- Open Access
Impact on Thermal Energy Needs Caused by the Use of Different Solar Irradiance Decomposition and Transposition Models: Application of EN ISO 52016-1 and EN ISO 52010-1 Standards for Five European Cities
To solve the series of heat balances that EN ISO 52016-1 uses to simulate the dynamic hourly energy requirements of a building, detailed climatic data are required as input. Differently from air temperatures, relative humidity and wind speed, which are easily measurable and available in databases, the direct and diffuse solar irradiances incident on the different inclined and oriented surfaces, which are fundamental for the evaluation of solar gains, must be estimated using one of the many regression models available in the literature. Therefore, in this work, the energy needs of buildings were evaluated with the simplified hourly dynamic method of EN ISO 52016-1 by varying the solar irradiance sets on inclined and oriented surfaces obtained from EN ISO 52010-1 and three other pairs of solar irradiance separation and transposition models. Five European locations and two different window solar transmission coefficients (ggl) were analysed. The results showed that on average, for the heating period and for both ggl, the use of the different methods causes an average error on the calculation of the annual demand of less or slightly more than 5%; while for the cooling period, the average error on the calculation of the annual demand is 16.4% for the case study with ggl = 0.28 and 25.1% for the case study with ggl = 0.63. On the other hand, analysing the root-mean-square-error of the hourly data, using the model contained in TRNSYS as a benchmark, for most of the cases, when varying window orientations, cities and ggl, the model that diverges furthest from the others is that contained in EN ISO 52010-1.
Open AccessImpact on Thermal Energy Needs Caused by the Use of Different Solar Irradiance Decomposition and Transposition Models: Application of EN ISO 52016-1 and EN ISO 52010-1 Standards for Five European Cities
To solve the series of heat balances that EN ISO 52016-1 uses to simulate the dynamic hourly energy requirements of a building, detailed climatic data are required as input. Differently from air temperatures, relative humidity and wind speed, which are easily measurable and available in databases, the direct and diffuse solar irradiances incident on the different inclined and oriented surfaces, which are fundamental for the evaluation of solar gains, must be estimated using one of the many regression models available in the literature. Therefore, in this work, the energy needs of buildings were evaluated with the simplified hourly dynamic method of EN ISO 52016-1 by varying the solar irradiance sets on inclined and oriented surfaces obtained from EN ISO 52010-1 and three other pairs of solar irradiance separation and transposition models. Five European locations and two different window solar transmission coefficients (ggl) were analysed. The results showed that on average, for the heating period and for both ggl, the use of the different methods causes an average error on the calculation of the annual demand of less or slightly more than 5%; while for the cooling period, the average error on the calculation of the annual demand is 16.4% for the case study with ggl = 0.28 and 25.1% for the case study with ggl = 0.63. On the other hand, analysing the root-mean-square-error of the hourly data, using the model contained in TRNSYS as a benchmark, for most of the cases, when varying window orientations, cities and ggl, the model that diverges furthest from the others is that contained in EN ISO 52010-1.
- Open Access
Comparative and Sensitivity Analysis of Numerical Methods for the Discretization of Opaque Structures and Parameters of Glass Components for EN ISO 52016-1
The EN ISO 52016-1:2017 standard introduced a new methodology for the hourly calculation of energy needs that allows the study of the dynamic energy performance of buildings. In this study, a comparative analysis was carried out between two heat transfer models for opaque building elements: the one described in the new standard EN ISO 52016-1:2017 (Annex B) and that proposed by the Italian national annex (Annex A). The analysis, carried out on 1854 cases, showed better results for the heating period than for the cooling period, with a lower Root-Mean-Square Error and Coefficient of Variation of the Root-Mean-Square Error for the model proposed by the Italian National Annex. Increasing the performance of the building by decreasing the solar transmission coefficient of the glazed surfaces leads to a worse Root-Mean-Square Error of about 11%. In addition, a sensitivity analysis of the thermo-physical parameters of the opaque building components was carried out and an alternative method for the calculation of the solar transmission coefficient was evaluated. The latter was able to improve the Root-Mean-Square Error of summer solar gains by 46.7% compared to the method proposed by the standard.
Open AccessComparative and Sensitivity Analysis of Numerical Methods for the Discretization of Opaque Structures and Parameters of Glass Components for EN ISO 52016-1
The EN ISO 52016-1:2017 standard introduced a new methodology for the hourly calculation of energy needs that allows the study of the dynamic energy performance of buildings. In this study, a comparative analysis was carried out between two heat transfer models for opaque building elements: the one described in the new standard EN ISO 52016-1:2017 (Annex B) and that proposed by the Italian national annex (Annex A). The analysis, carried out on 1854 cases, showed better results for the heating period than for the cooling period, with a lower Root-Mean-Square Error and Coefficient of Variation of the Root-Mean-Square Error for the model proposed by the Italian National Annex. Increasing the performance of the building by decreasing the solar transmission coefficient of the glazed surfaces leads to a worse Root-Mean-Square Error of about 11%. In addition, a sensitivity analysis of the thermo-physical parameters of the opaque building components was carried out and an alternative method for the calculation of the solar transmission coefficient was evaluated. The latter was able to improve the Root-Mean-Square Error of summer solar gains by 46.7% compared to the method proposed by the standard.