Adam D. Fletcher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Adam D. Fletcher has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Anthony J. Peyton
Department of Electrical and Electronic Engineering, School of Engineering, The University of Manchester, Manchester, U.K.
6 shared publications - Henok Tesfalem
Department of Electrical and Electronic Engineering, University of Manchester, Manchester, U.K.
2 shared publications - Joel Hampton
Department of Electrical and Electronic Engineering, University of Manchester, Manchester, U.K.
2 shared publications - Liam A. Marsh
Department of Electronic and Electrical Engineering, University of Manchester, Manchester M13 9PL, UK
2 shared publications - Michael Daniel O'Toole
Department of Electrical and Electronic Engineering, The University of Manchester, Manchester, U.K.
2 shared publications - Richard John Colgan
Natural Resources Institute, University of Greenwich
2 shared publications
Latest Publications
- Open Access
- 28 September 2026
- Published by Elsevier in SSRN Electronic Journal
Magnetic Induction Spectroscopy for Cellular-Structure-Related Bioimpedance Assessment
This work explores the application of Magnetic Induction Spectroscopy (MIS) as a tool for phenotyping cellular structural degradation in biological tissues, specifically plant parenchyma. The principal advantage of MIS is its non-contact operation, whereby induced eddy currents probe bulk electrical properties without physical or electrical contact, avoiding electrode-interface artefacts and sample perturbation. A previously developed differential-coil MIS sensor, with sensitivity optimised via a tuned passive network, was used to measure conductivity spectra from 70 kHz to 9 MHz. Avocado fruit, potato, and apples were subjected to three freeze-thaw cycles as a controlled model of cellular structural degradation. Across the three tissue types, freeze-thaw treatment progressively attenuated the conductivity dispersion, consistent with weakened Maxwell-Wagner interfacial polarisation and loss of cellular compartmentalisation. Correspondingly, dispersion indices, including the model-fitted conductivity dispersion magnitude, Δσ, and the ratio between the low- and high-frequency conductivity, Py, decreased, with Py falling by 40–95% from the fresh state to the third cycle. Bright-field microscopy independently confirmed progressive disruption of cellular boundaries and tissue organisation. These results support that MIS-derived dispersion metrics can provide a quantitative, label-free, non-contact, and volumetric indicator of cellular degradation in bulk biological tissues, with potential applications in biological and agri-food quality assessment.
- 28 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMagnetic Induction Spectroscopy for Cellular-Structure-Related Bioimpedance Assessment
This work explores the application of Magnetic Induction Spectroscopy (MIS) as a tool for phenotyping cellular structural degradation in biological tissues, specifically plant parenchyma. The principal advantage of MIS is its non-contact operation, whereby induced eddy currents probe bulk electrical properties without physical or electrical contact, avoiding electrode-interface artefacts and sample perturbation. A previously developed differential-coil MIS sensor, with sensitivity optimised via a tuned passive network, was used to measure conductivity spectra from 70 kHz to 9 MHz. Avocado fruit, potato, and apples were subjected to three freeze-thaw cycles as a controlled model of cellular structural degradation. Across the three tissue types, freeze-thaw treatment progressively attenuated the conductivity dispersion, consistent with weakened Maxwell-Wagner interfacial polarisation and loss of cellular compartmentalisation. Correspondingly, dispersion indices, including the model-fitted conductivity dispersion magnitude, Δσ, and the ratio between the low- and high-frequency conductivity, Py, decreased, with Py falling by 40–95% from the fresh state to the third cycle. Bright-field microscopy independently confirmed progressive disruption of cellular boundaries and tissue organisation. These results support that MIS-derived dispersion metrics can provide a quantitative, label-free, non-contact, and volumetric indicator of cellular degradation in bulk biological tissues, with potential applications in biological and agri-food quality assessment.
- Open Access
Approximating the Performance of a Time-Domain Pulsed Induction EMI Sensor with Multiple Frequency-Domain FEM Simulations for Improved Modelling of Arctic Sea-Ice Thickness
One of the key challenges with developing pulsed induction (PI) electromagnetic induction (EMI) sensors for use in the Arctic is the inaccessibility of the environment, which makes in situ testing prohibitively expensive. To mitigate this, sensor development can be streamlined through the creation of a robust simulation strategy with which to optimize features such as coil turns and geometry. Building on work that previously presented a method for simulating an Arctic PI sensor via a time-domain finite element model (FEM), this paper presents a method for approximating a time-domain simulation with multiple frequency-domain simulations. A comparison between the fast Fourier transform (FFT) of a time-domain simulation and a collection of frequency-domain simulations is presented. These are validated against empirical data with a PI sensor over seawater, with an air gap used as a proxy for sea ice. Using the method described, a range of coils is simulated with dimensions from m up to m, demonstrating the ability of this approach to enable comparison of sensor performance over a wider parameter space. For a parametric sweep over 10 sensor-to-seawater lift-off distances, the improvement from the time-domain simulation (of a 402 s window) to the frequency-domain simulation (comprising 100 discrete frequencies) represents a reduction in simulation time from 38,013 min to 141 min.Open AccessApproximating the Performance of a Time-Domain Pulsed Induction EMI Sensor with Multiple Frequency-Domain FEM Simulations for Improved Modelling of Arctic Sea-Ice Thickness
One of the key challenges with developing pulsed induction (PI) electromagnetic induction (EMI) sensors for use in the Arctic is the inaccessibility of the environment, which makes in situ testing prohibitively expensive. To mitigate this, sensor development can be streamlined through the creation of a robust simulation strategy with which to optimize features such as coil turns and geometry. Building on work that previously presented a method for simulating an Arctic PI sensor via a time-domain finite element model (FEM), this paper presents a method for approximating a time-domain simulation with multiple frequency-domain simulations. A comparison between the fast Fourier transform (FFT) of a time-domain simulation and a collection of frequency-domain simulations is presented. These are validated against empirical data with a PI sensor over seawater, with an air gap used as a proxy for sea ice. Using the method described, a range of coils is simulated with dimensions from m up to m, demonstrating the ability of this approach to enable comparison of sensor performance over a wider parameter space. For a parametric sweep over 10 sensor-to-seawater lift-off distances, the improvement from the time-domain simulation (of a 402 s window) to the frequency-domain simulation (comprising 100 discrete frequencies) represents a reduction in simulation time from 38,013 min to 141 min. - Open Access
- 7 November 2025
- Published by MDPI AG in Instruments
- Vol. 9 (4) , 27
Evaluation of a Low-Power Computer Vision-Based Positioning System for a Handheld Landmine Detector Using AprilTag Markers
A positioning system employing visual fiducial markers (AprilTags) has been implemented for use with handheld mine detection equipment. To be suitable for a battery-powered real-time application, the system has been designed to operate at low power (<100 mW) and frame rates between 30 and 50 fps. The system has been integrated into an experimental dual-mode detector system. Position-indexed metal detector and ground-penetrating radar data from laboratory and field trials are presented. The accuracy and precision of the vision-based system are found to be 1.2 cm and 0.5 cm, respectively.
- 7 November 2025
- Published by MDPI AG in Instruments
- Vol. 9 (4) , 27
Open AccessEvaluation of a Low-Power Computer Vision-Based Positioning System for a Handheld Landmine Detector Using AprilTag Markers
A positioning system employing visual fiducial markers (AprilTags) has been implemented for use with handheld mine detection equipment. To be suitable for a battery-powered real-time application, the system has been designed to operate at low power (<100 mW) and frame rates between 30 and 50 fps. The system has been integrated into an experimental dual-mode detector system. Position-indexed metal detector and ground-penetrating radar data from laboratory and field trials are presented. The accuracy and precision of the vision-based system are found to be 1.2 cm and 0.5 cm, respectively.
- Open Access
Magnetic Induction Spectroscopy-Based Non-Contact Assessment of Avocado Fruit Condition
This study demonstrates that the ripeness of avocado fruits can be analyzed using frequency-dependent electrical conductivity and permittivity through a non-invasive Magnetic Induction Spectroscopy (MIS) method. Utilizing an MIS system for conductivity and permittivity measurements of a large sample set () of avocado fruits across multiple frequencies from 100 kHz to 3 MHz enables clear observation of their dispersion behavior and the evolution of their spectra over ripening time in a completely non-contact manner. For the entire sample batch, the conductivity spectrum exhibits a general upward shift and spectral flattening over ripening time. To further quantify these features, normalized gradient analysis and equivalent circuit modeling were employed, and statistical analysis confirmed the correlations between electrical parameters and ripening stages. The trend characteristics of the normalized gradient parameter provide a basis for defining the three ripening stages within the 22-day period: early pre-ripe stage (0–5 days), ripe stage (5–15 days), and overripe stage (after 15 days). The equivalent circuit model, which is both physically interpretable and fitted to experimental data, revealed that the ripening process of avocado fruits is characterized by a weakening of capacitive structures and an increase in extracellular solution conductivity, suggesting changes in cellular integrity and extracellular composition, respectively. The results also highlight significant inter-sample variability, which is inherent to biological samples. To further investigate individual conductivity variation trends, Gaussian Mixture Model (GMM) clustering and Principal Component Analysis (PCA) was conducted for exploratory sample classification and visualization. Through this approach, the sample set was classified into three categories, each corresponding to distinct conductivity variation patterns.Open AccessMagnetic Induction Spectroscopy-Based Non-Contact Assessment of Avocado Fruit Condition
This study demonstrates that the ripeness of avocado fruits can be analyzed using frequency-dependent electrical conductivity and permittivity through a non-invasive Magnetic Induction Spectroscopy (MIS) method. Utilizing an MIS system for conductivity and permittivity measurements of a large sample set () of avocado fruits across multiple frequencies from 100 kHz to 3 MHz enables clear observation of their dispersion behavior and the evolution of their spectra over ripening time in a completely non-contact manner. For the entire sample batch, the conductivity spectrum exhibits a general upward shift and spectral flattening over ripening time. To further quantify these features, normalized gradient analysis and equivalent circuit modeling were employed, and statistical analysis confirmed the correlations between electrical parameters and ripening stages. The trend characteristics of the normalized gradient parameter provide a basis for defining the three ripening stages within the 22-day period: early pre-ripe stage (0–5 days), ripe stage (5–15 days), and overripe stage (after 15 days). The equivalent circuit model, which is both physically interpretable and fitted to experimental data, revealed that the ripening process of avocado fruits is characterized by a weakening of capacitive structures and an increase in extracellular solution conductivity, suggesting changes in cellular integrity and extracellular composition, respectively. The results also highlight significant inter-sample variability, which is inherent to biological samples. To further investigate individual conductivity variation trends, Gaussian Mixture Model (GMM) clustering and Principal Component Analysis (PCA) was conducted for exploratory sample classification and visualization. Through this approach, the sample set was classified into three categories, each corresponding to distinct conductivity variation patterns. - Open Access
Adaptation of a Differential Scanning Calorimeter for Simultaneous Electromagnetic Measurements
Although much information can be gained about thermally induced microstructural changes in metals through the measurement of their thermophysical properties using a differential scanning calorimeter (DSC), due to competing influences on the signal, not all microstructural changes can be fully characterised this way. For example, accurate characterisation of recrystallisation, tempering, and changes in retained delta ferrite in alloyed steels becomes complex due to additional signal changes due to the Curie point, oxidation, and the rate (and therefore the magnitude) of transformation. However, these types of microstructural changes have been shown to invoke strong magnetic and electromagnetic (EM) responses; therefore, simultaneous EM measurements can provide additional complementary data which can help to emphasise or deconvolute these complex signals and develop a more complete understanding of certain metallurgical phenomena. This paper discusses how a DSC machine has been modified to incorporate an EM sensor consisting of two copper coils printed onto either side of a ceramic substrate, with one coil acting as a transmitter and the other as a receiver. The coil is interfaced with a custom-built data acquisition system, which provides current to the transmit coil, records signals from the receive coil, and is controlled by a graphical user interface which allows the user to select multiple excitation frequencies. The equipment has a useable frequency range of approximately 1–100 kHz and outputs phase and magnitude readings at a rate of approximately 50 samples per second. Simultaneous DSC-EM measurements were performed on a nickel sample up to a temperature of 600 °C, with the reversable ferromagnetic to paramagnetic transition in the nickel sample invoking a clear EM response. The results show that the combined DSC-EM apparatus has the potential to provide a powerful tool for the analysis of thermally induced microstructural changes in metals, feeding into research on steel production, development of magnetic and conductive materials, and many more areas.
Open AccessAdaptation of a Differential Scanning Calorimeter for Simultaneous Electromagnetic Measurements
Although much information can be gained about thermally induced microstructural changes in metals through the measurement of their thermophysical properties using a differential scanning calorimeter (DSC), due to competing influences on the signal, not all microstructural changes can be fully characterised this way. For example, accurate characterisation of recrystallisation, tempering, and changes in retained delta ferrite in alloyed steels becomes complex due to additional signal changes due to the Curie point, oxidation, and the rate (and therefore the magnitude) of transformation. However, these types of microstructural changes have been shown to invoke strong magnetic and electromagnetic (EM) responses; therefore, simultaneous EM measurements can provide additional complementary data which can help to emphasise or deconvolute these complex signals and develop a more complete understanding of certain metallurgical phenomena. This paper discusses how a DSC machine has been modified to incorporate an EM sensor consisting of two copper coils printed onto either side of a ceramic substrate, with one coil acting as a transmitter and the other as a receiver. The coil is interfaced with a custom-built data acquisition system, which provides current to the transmit coil, records signals from the receive coil, and is controlled by a graphical user interface which allows the user to select multiple excitation frequencies. The equipment has a useable frequency range of approximately 1–100 kHz and outputs phase and magnitude readings at a rate of approximately 50 samples per second. Simultaneous DSC-EM measurements were performed on a nickel sample up to a temperature of 600 °C, with the reversable ferromagnetic to paramagnetic transition in the nickel sample invoking a clear EM response. The results show that the combined DSC-EM apparatus has the potential to provide a powerful tool for the analysis of thermally induced microstructural changes in metals, feeding into research on steel production, development of magnetic and conductive materials, and many more areas.
- Open Access
Balancing of Resonant Differential Coils for Broadband Inductive Sensor Systems
Differential coils are frequently implemented in inductive sensing systems. They can be considered as a single coil that is made up of two or more subcoils, wound in series opposition. They can be used on the transmit or receive side of measurement systems, and, if designed correctly, ensure no coupling between coils under background conditions. By cancelling background coupling, the receive electronics only needs to be able to measure the change in coupling produced by a target. This allows for a more efficient use of the dynamic range, and for larger receive-side amplifier gain, thereby improving SNR. When subcoils are not electrically similar, it can be hard to engineer the coil to be perfectly balanced across a wide bandwidth. This paper presents an analytical model of a resonant differential coil pair that is tested and applied on a planar metal detector for the detection of buried objects. The model demonstrates the capability to balance an arbitrary differential coil pair, which has a broad applicability across a range of inductive sensor applications such as metal detection and non-destructive testing. The method is applied to the practical system. The results show that the correction resulting from this method ensures a stable balance across a significantly enhanced bandwidth. In the case studied here, the bandwidth of the experimental system is increased from 20 kHz to 90 kHz.
Open AccessBalancing of Resonant Differential Coils for Broadband Inductive Sensor Systems
Differential coils are frequently implemented in inductive sensing systems. They can be considered as a single coil that is made up of two or more subcoils, wound in series opposition. They can be used on the transmit or receive side of measurement systems, and, if designed correctly, ensure no coupling between coils under background conditions. By cancelling background coupling, the receive electronics only needs to be able to measure the change in coupling produced by a target. This allows for a more efficient use of the dynamic range, and for larger receive-side amplifier gain, thereby improving SNR. When subcoils are not electrically similar, it can be hard to engineer the coil to be perfectly balanced across a wide bandwidth. This paper presents an analytical model of a resonant differential coil pair that is tested and applied on a planar metal detector for the detection of buried objects. The model demonstrates the capability to balance an arbitrary differential coil pair, which has a broad applicability across a range of inductive sensor applications such as metal detection and non-destructive testing. The method is applied to the practical system. The results show that the correction resulting from this method ensures a stable balance across a significantly enhanced bandwidth. In the case studied here, the bandwidth of the experimental system is increased from 20 kHz to 90 kHz.
- 29 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (4) , 6109-6118
Physics-Guided Deep Learning for Plate Permeability Estimation With Single to Multiple Frequency Transformation of Eddy-Current Testing
Eddy-current testing technique has been extensively explored for estimating the electromagnetic property of steel plates in various industrial applications. In this article, a physics-guided deep learning (DL) method is proposed to estimate the permeability of plate in high thickness with probe liftoff. A simplified analytical model is derived, which realises the single to multiple frequency inductance transformation and calculates the related physical properties of the measurement configuration. A constant is found, which is a fundamental coefficient describing the first-order nature of the sensor response to a plate and it is insensitive to plate properties and probe dimensions. The nonlinear mapping from physical information, derived from the simplified analytical model, to plate permeability is constructed by the DL model based on the modified ResNet18-1D. Numerical simulations and experiments have been performed to evaluate the proposed method for permeability estimation with various plate materials and probe liftoff. The method achieves real-time accurate estimation of plate permeability with a relative error lower than 3%.
- 29 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (4) , 6109-6118
Physics-Guided Deep Learning for Plate Permeability Estimation With Single to Multiple Frequency Transformation of Eddy-Current Testing
Eddy-current testing technique has been extensively explored for estimating the electromagnetic property of steel plates in various industrial applications. In this article, a physics-guided deep learning (DL) method is proposed to estimate the permeability of plate in high thickness with probe liftoff. A simplified analytical model is derived, which realises the single to multiple frequency inductance transformation and calculates the related physical properties of the measurement configuration. A constant is found, which is a fundamental coefficient describing the first-order nature of the sensor response to a plate and it is insensitive to plate properties and probe dimensions. The nonlinear mapping from physical information, derived from the simplified analytical model, to plate permeability is constructed by the DL model based on the modified ResNet18-1D. Numerical simulations and experiments have been performed to evaluate the proposed method for permeability estimation with various plate materials and probe liftoff. The method achieves real-time accurate estimation of plate permeability with a relative error lower than 3%.
- Open Access
- 18 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (11) , 10699-10707
Calibration of a Finite Element Forward Model in Eddy Current Inspection
We report on the use of a novel constrained optimisation algorithm for calibrating the finite element model in an eddy current inspection application. An accurate finite element forward model is often important in such eddy current applications for training neural networks or as part of an iterative solver. However, the subject of calibration of the model has not received much attention in the literature to date. We consider a multi-frequency, eddy current depth profiling application, which is important for non-destructive testing in the nuclear industry. In the optimisation algorithm, we use a Levenberg-Marquardt algorithm and a bisection search to ensure constraints are satisfied, coupled with a truncated Gradient and Hessian method. We calibrate two types of finite element models, one using a filament representation for the coils and the other using a full 3D approach. The results show the feasibility of using the constrained non-linear optimisation algorithm for tuning the finite element model parameters. The mean signal-noise ratio after tuning on a truncated spectrum was 29.47 dB for the 3D model and 28.96 dB for the filament; in contrast the mean SNR using the measured coil parameters was 1.48 dB and 4.98 dB for the two uncalibrated models, respectively. The results show that a filament model is competitive with a 3D model of the coils (within the nuclear graphite application); therefore, a computationally faster filament model can be used with minimal effect on accuracy.
- 18 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (11) , 10699-10707
Open AccessCalibration of a Finite Element Forward Model in Eddy Current Inspection
We report on the use of a novel constrained optimisation algorithm for calibrating the finite element model in an eddy current inspection application. An accurate finite element forward model is often important in such eddy current applications for training neural networks or as part of an iterative solver. However, the subject of calibration of the model has not received much attention in the literature to date. We consider a multi-frequency, eddy current depth profiling application, which is important for non-destructive testing in the nuclear industry. In the optimisation algorithm, we use a Levenberg-Marquardt algorithm and a bisection search to ensure constraints are satisfied, coupled with a truncated Gradient and Hessian method. We calibrate two types of finite element models, one using a filament representation for the coils and the other using a full 3D approach. The results show the feasibility of using the constrained non-linear optimisation algorithm for tuning the finite element model parameters. The mean signal-noise ratio after tuning on a truncated spectrum was 29.47 dB for the 3D model and 28.96 dB for the filament; in contrast the mean SNR using the measured coil parameters was 1.48 dB and 4.98 dB for the two uncalibrated models, respectively. The results show that a filament model is competitive with a 3D model of the coils (within the nuclear graphite application); therefore, a computationally faster filament model can be used with minimal effect on accuracy.
- 13 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (15) , 17005-17016
Electrical Resistivity Reconstruction of Graphite Moderator Bricks From Multi-Frequency Measurements and Artificial Neural Networks
This paper discusses an artificial neural inversion approach for non-destructive testing of the graphite moderator bricks that make up the cores of Advanced Gas-Cooled Reactors (AGR). The study employed fully connected feedforward neural networks consisting of four hidden layers and trained with backpropagation approach using Levenberg-Marquardt optimisation algorithm. The approach is based on multi-frequency (MF) eddy current (EC) measurements, and combinations of simulated and measured datasets from a laboratory sample and one of the operating reactor core, along with different regularisation parameters were used to train and test the networks. Various types of artificially generated errors were added to the data during training procedures, which in turn allowed for error tolerance and improved the generalisation of the ANNs to unseen test datasets. First, the ANN was tested using unseen simulated data, followed by the measurements collected from laboratory sample and one of the operating reactor core. The first test from the unseen simulated data showed mean profile error ranging between 1.30% and 8.20%, whereas the profiles estimated from reactor core measurements showed mean profile error ranging between 1.84% and 17.80% when compared with the resistivity measurements from trepanned graphite sample taken out of the reactor core. Further comparison of the network outputs against the profiles estimated using traditional iterative inversion algorithm indicates reasonable agreement between the two approaches with the exception of one case, but the solution time for the ANN was found to be over three orders of magnitude faster than the iterative inversion algorithm.
- 13 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (15) , 17005-17016
Electrical Resistivity Reconstruction of Graphite Moderator Bricks From Multi-Frequency Measurements and Artificial Neural Networks
This paper discusses an artificial neural inversion approach for non-destructive testing of the graphite moderator bricks that make up the cores of Advanced Gas-Cooled Reactors (AGR). The study employed fully connected feedforward neural networks consisting of four hidden layers and trained with backpropagation approach using Levenberg-Marquardt optimisation algorithm. The approach is based on multi-frequency (MF) eddy current (EC) measurements, and combinations of simulated and measured datasets from a laboratory sample and one of the operating reactor core, along with different regularisation parameters were used to train and test the networks. Various types of artificially generated errors were added to the data during training procedures, which in turn allowed for error tolerance and improved the generalisation of the ANNs to unseen test datasets. First, the ANN was tested using unseen simulated data, followed by the measurements collected from laboratory sample and one of the operating reactor core. The first test from the unseen simulated data showed mean profile error ranging between 1.30% and 8.20%, whereas the profiles estimated from reactor core measurements showed mean profile error ranging between 1.84% and 17.80% when compared with the resistivity measurements from trepanned graphite sample taken out of the reactor core. Further comparison of the network outputs against the profiles estimated using traditional iterative inversion algorithm indicates reasonable agreement between the two approaches with the exception of one case, but the solution time for the ANN was found to be over three orders of magnitude faster than the iterative inversion algorithm.