Wayne Yong Xiang Foo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wayne Yong Xiang Foo has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Andrew Chia Chen Chou
KK Women's and Children's Hospital
2 shared publicationsDarren Keng Jin Tay
Department of Orthopaedic Surgery, Singapore General Hospital, Bukit Merah, Singapore
2 shared publicationsDenny Tijauw Tjoen Lie
Department of Orthopaedic Surgery, Singapore General Hospital, 20 College Road, Academia, Level 4, Singapore 169865, Singapore
2 shared publicationsJerry Yongqiang Chen
Department of Orthopaedic Surgery, Singapore General Hospital, Bukit Merah, Singapore
2 shared publicationsMing Han Lincoln Liow
Department of Orthopaedic Surgery, Singapore General Hospital, Bukit Merah, Singapore
2 shared publicationsSeng Jin Yeo
Department of Orthopaedic Surgery, Singapore General Hospital, Bukit Merah, Singapore
2 shared publications
Latest Publications
- Open Access
- 25 May 2026
- Published by Wiley in Arthroscopy Techniques
- Vol. 15 (8) , e70159
Techniques of Arthroscopic Anterior Syndesmosis Stabilization
Ankle sprains are among the most common sports‐related musculoskeletal injuries. Injury to the anterior inferior tibiofibular ligament, resulting in anterior syndesmotic instability, is frequently overlooked and inadequately treated. The purpose of this technical note is to (1) describe clinical examination maneuvers used to assess anterior syndesmotic stability; (2) review radiologic features suggestive of syndesmotic instability; and (3) present 2 arthroscopically assisted techniques for anterior inferior tibiofibular ligament reconstruction. The surgical techniques are described stepwise, with emphasis on indications, technical pearls, and potential pitfalls.
- 25 May 2026
- Published by Wiley in Arthroscopy Techniques
- Vol. 15 (8) , e70159
Open AccessTechniques of Arthroscopic Anterior Syndesmosis Stabilization
Ankle sprains are among the most common sports‐related musculoskeletal injuries. Injury to the anterior inferior tibiofibular ligament, resulting in anterior syndesmotic instability, is frequently overlooked and inadequately treated. The purpose of this technical note is to (1) describe clinical examination maneuvers used to assess anterior syndesmotic stability; (2) review radiologic features suggestive of syndesmotic instability; and (3) present 2 arthroscopically assisted techniques for anterior inferior tibiofibular ligament reconstruction. The surgical techniques are described stepwise, with emphasis on indications, technical pearls, and potential pitfalls.
- Open Access
- 1 April 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (2)
Generative Artificial Intelligence Chatbots for Parental Guidance in Pediatric Orthopaedics: A Pilot Feasibility Study
Background: Parents of children with pediatric orthopaedic conditions frequently have questions after their clinic visit, and a reliable postconsultation resource to address these enquiries is lacking. Online resources are variable in quality, and general purpose artificial intelligence (AI) models have demonstrated safety limitations, including unprompted treatment recommendations and citation inaccuracies. A purpose-built, supervised generative AI solution may offer a safer and more reliable alternative. Methods: A generative AI chatbot was developed using retrieval-augmented generation and trained on OrthoKids educational materials covering 5 common pediatric orthopaedic conditions: in-toeing, flatfoot, scoliosis, bow legs, and knock knees. After iterative refinement by 2 fellowship-trained pediatric orthopaedic surgeons, the chatbot was evaluated by 18 multidisciplinary clinicians using a structured 12-item 5-point Likert scale survey assessing accuracy, safety, usability, and clinical acceptability. Results: Mean scores exceeded 4.0 of 5.0 on 11 of 12 domains. Clarity of explanation achieved unanimous positive endorsement (100%), while protocol alignment received the highest mean score (4.50 ± 0.62). Citation accuracy was the lowest-rated domain (4.00 ± 0.77). No hallucinations were identified, and 88.9% of evaluators confirmed the absence of unprompted treatment recommendations. The reverse-scored safety item (Q8) demonstrated the greatest inter-rater variability (mean 3.11 ± 1.57), with orthopaedic specialists rating perceived harm substantially lower (mean 1.33) than nurses (mean 4.40). Conclusion: A purpose-built gen AI chatbot demonstrated high clinical accuracy and acceptability among multidisciplinary evaluators, with effective avoidance of unprompted treatment recommendations. These pilot findings support feasibility for use as a parental education adjunct in pediatric orthopaedic practice. Level of Evidence: Level III . See Instructions for Authors for a complete description of levels of evidence.
- 1 April 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (2)
Open AccessGenerative Artificial Intelligence Chatbots for Parental Guidance in Pediatric Orthopaedics: A Pilot Feasibility Study
Background: Parents of children with pediatric orthopaedic conditions frequently have questions after their clinic visit, and a reliable postconsultation resource to address these enquiries is lacking. Online resources are variable in quality, and general purpose artificial intelligence (AI) models have demonstrated safety limitations, including unprompted treatment recommendations and citation inaccuracies. A purpose-built, supervised generative AI solution may offer a safer and more reliable alternative. Methods: A generative AI chatbot was developed using retrieval-augmented generation and trained on OrthoKids educational materials covering 5 common pediatric orthopaedic conditions: in-toeing, flatfoot, scoliosis, bow legs, and knock knees. After iterative refinement by 2 fellowship-trained pediatric orthopaedic surgeons, the chatbot was evaluated by 18 multidisciplinary clinicians using a structured 12-item 5-point Likert scale survey assessing accuracy, safety, usability, and clinical acceptability. Results: Mean scores exceeded 4.0 of 5.0 on 11 of 12 domains. Clarity of explanation achieved unanimous positive endorsement (100%), while protocol alignment received the highest mean score (4.50 ± 0.62). Citation accuracy was the lowest-rated domain (4.00 ± 0.77). No hallucinations were identified, and 88.9% of evaluators confirmed the absence of unprompted treatment recommendations. The reverse-scored safety item (Q8) demonstrated the greatest inter-rater variability (mean 3.11 ± 1.57), with orthopaedic specialists rating perceived harm substantially lower (mean 1.33) than nurses (mean 4.40). Conclusion: A purpose-built gen AI chatbot demonstrated high clinical accuracy and acceptability among multidisciplinary evaluators, with effective avoidance of unprompted treatment recommendations. These pilot findings support feasibility for use as a parental education adjunct in pediatric orthopaedic practice. Level of Evidence: Level III . See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 12 February 2026
- Published by Charter Services New York d/b/a Journal of Orthopaedic Experience and Innovation in Journal of Orthopaedic Experience & Innovation
Automating Cobb angle measurement in adolescent idiopathic scoliosis based on leveraging a computer vision algorithm
Introduction: The Cobb angle is the gold standard metric for evaluating adolescent idiopathic scoliosis. Currently, measurement is done manually by a physician using scoliosis radiographs, which can be time-consuming and subject to human error. We aim to evaluate the accuracy and efficiency of a computer vision algorithm in measuring Cobb angles for adolescent idiopathic scoliosis compared to manual measurement. Methods: A computer vision-based algorithm to automate the process of measuring the Cobb angle was developed using 500 annotated scoliosis radiographs and tested on 54 images. Measurements were compared to those of two orthopaedic surgeons in terms of angle accuracy, detection of multiple curves, and measurement time. The application is run locally with a model built on Tensorflow Keras using Python. Results: The algorithm can correctly identify scoliosis, correctly segment multiple curves within the same spine, and calculate a Cobb angle with a mean angle difference of 4.50 + 5.19° compared to the human measurements, within acceptable interobserver reliability. It measured Cobb angles in under 10 seconds in >95% of cases, versus an average of 3 minutes manually, representing a time savings of over 90%. All users found the software intuitive and clinically helpful. Conclusion: The algorithm can reliably and efficiently measure multiple Cobb angles in a plain coronal scoliosis radiograph in less than 10 seconds. This can potentially be deployed to improve the accuracy and efficiency of Cobb angle measurements in various healthcare settings and can potentially be used in pre-operative surgical planning and intra-operative alignment checks in the future.
- 12 February 2026
- Published by Charter Services New York d/b/a Journal of Orthopaedic Experience and Innovation in Journal of Orthopaedic Experience & Innovation
Open AccessAutomating Cobb angle measurement in adolescent idiopathic scoliosis based on leveraging a computer vision algorithm
Introduction: The Cobb angle is the gold standard metric for evaluating adolescent idiopathic scoliosis. Currently, measurement is done manually by a physician using scoliosis radiographs, which can be time-consuming and subject to human error. We aim to evaluate the accuracy and efficiency of a computer vision algorithm in measuring Cobb angles for adolescent idiopathic scoliosis compared to manual measurement. Methods: A computer vision-based algorithm to automate the process of measuring the Cobb angle was developed using 500 annotated scoliosis radiographs and tested on 54 images. Measurements were compared to those of two orthopaedic surgeons in terms of angle accuracy, detection of multiple curves, and measurement time. The application is run locally with a model built on Tensorflow Keras using Python. Results: The algorithm can correctly identify scoliosis, correctly segment multiple curves within the same spine, and calculate a Cobb angle with a mean angle difference of 4.50 + 5.19° compared to the human measurements, within acceptable interobserver reliability. It measured Cobb angles in under 10 seconds in >95% of cases, versus an average of 3 minutes manually, representing a time savings of over 90%. All users found the software intuitive and clinically helpful. Conclusion: The algorithm can reliably and efficiently measure multiple Cobb angles in a plain coronal scoliosis radiograph in less than 10 seconds. This can potentially be deployed to improve the accuracy and efficiency of Cobb angle measurements in various healthcare settings and can potentially be used in pre-operative surgical planning and intra-operative alignment checks in the future.
- 29 March 2024
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (5) , 2249-2256
Severe genu varus deformity does not affect enhanced recovery after surgery total knee arthroplasty outcomes
Introduction Enhanced recovery after surgery (ERAS) has been increasingly adopted in orthopaedic surgery. Although not an exclusion criterion, patients undergoing total knee arthroplasty (TKA) with preoperative severe varus deformity may be less likely to be enrolled for ERAS. This study aimed to compare the success of ERAS TKA between patients with severe preoperative varus deformities (≥ 15° varus) and the control group (< 15° varus to 14° valgus). Our secondary aim was to compare postoperative complications and functional outcomes between the two groups. Materials & methods 310 TKAs performed from August 2019 to February 2021 were analyzed with a follow-up of 6 months postoperatively. The primary outcome, ERAS TKA success, was defined as length of hospital stay of < 24 h. Other parameters included 30-day postoperative complications and clinical outcomes such as the original Oxford Knee Score (OKS), the Knee Society Knee (KSKS) and Function Score (KSFS), Visual Analog Scale for Pain (VAS-P), 36-Item Short-Form Health Survey (SF-36) Physical Component Summary (PCS) and SF-36 Mental Component Summary (MCS). Results There were 119 patients in the severe deformity group and 191 patients in the control group. There were no significant differences in ERAS success between the severe deformity group and control group, with both groups achieving similarly high rates (> 90%) of ERAS success. There were also no differences in 30-day postoperative complications and 6-month postoperative clinical outcomes. Conclusion Patients with severe preoperative varus deformity undergoing ERAS TKA achieved high ERAS success rates (> 90%). Genu varum is not a contraindication for ERAS TKA.
- 29 March 2024
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (5) , 2249-2256
Severe genu varus deformity does not affect enhanced recovery after surgery total knee arthroplasty outcomes
Introduction Enhanced recovery after surgery (ERAS) has been increasingly adopted in orthopaedic surgery. Although not an exclusion criterion, patients undergoing total knee arthroplasty (TKA) with preoperative severe varus deformity may be less likely to be enrolled for ERAS. This study aimed to compare the success of ERAS TKA between patients with severe preoperative varus deformities (≥ 15° varus) and the control group (< 15° varus to 14° valgus). Our secondary aim was to compare postoperative complications and functional outcomes between the two groups. Materials & methods 310 TKAs performed from August 2019 to February 2021 were analyzed with a follow-up of 6 months postoperatively. The primary outcome, ERAS TKA success, was defined as length of hospital stay of < 24 h. Other parameters included 30-day postoperative complications and clinical outcomes such as the original Oxford Knee Score (OKS), the Knee Society Knee (KSKS) and Function Score (KSFS), Visual Analog Scale for Pain (VAS-P), 36-Item Short-Form Health Survey (SF-36) Physical Component Summary (PCS) and SF-36 Mental Component Summary (MCS). Results There were 119 patients in the severe deformity group and 191 patients in the control group. There were no significant differences in ERAS success between the severe deformity group and control group, with both groups achieving similarly high rates (> 90%) of ERAS success. There were also no differences in 30-day postoperative complications and 6-month postoperative clinical outcomes. Conclusion Patients with severe preoperative varus deformity undergoing ERAS TKA achieved high ERAS success rates (> 90%). Genu varum is not a contraindication for ERAS TKA.
- 27 September 2023
- Published by Elsevier in Clinical Biomechanics
- Vol. 110, 106115
Abduction causes increased strain gradient compared to forward flexion: Evidence from a cadaver model of simultaneous strain study of the rotator cuff tendons
- 27 September 2023
- Published by Elsevier in Clinical Biomechanics
- Vol. 110, 106115
Abduction causes increased strain gradient compared to forward flexion: Evidence from a cadaver model of simultaneous strain study of the rotator cuff tendons
- 30 January 2022
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 142 (12) , 3977-3985
All-polyethylene unicompartmental knee arthroplasty is associated with increased risks of poorer knee society knee score and lower satisfaction in obese patients
Background Although metal-backed tibial component (MB) is biomechanically superior to all-polyethylene (AP) implants in fixed-bearing unicompartmental knee arthroplasty (UKA), recent studies have shown comparable functional outcomes between the two. However, no study has examined this comparison in obese patients (BMI ≥ 30 kg/m2). We investigated whether functional outcomes between the two implants differ among obese patients, and whether the extent of obesity influences these outcomes. Patients and methods Four hundred twenty-two UKA implants from 347 obese patients were reviewed retrospectively. Patients were assessed using the Knee Society Knee Score (KSKS) and Function Score (KSFS), the original Oxford Knee Score (OKS), and SF-36 Physical Component Summary (PCS) and Mental Component Summary (MCS). Minimal clinically important difference (MCID) attainment was recorded. Patients’ fulfillment of expectations and satisfaction with the surgery outcome was also graded. Patients were further divided into lower obesity (BMI 30–34.9 kg/m2) and higher obesity (BMI ≥ 35 kg/m2) to examine effect modification. Results There were no differences in functional outcomes and quality-of-life scores, MCID attainment of functional scores, as well as satisfaction and expectation fulfillment between AP and MB. Among higher obesity patients, AP was associated with a poorer KSKS (p = 0.031) and lower proportion of satisfaction fulfillment (p = 0.041) 2 years postoperatively compared to MB. Conclusion We found no differences in functional and quality-of-life outcomes between fixed-bearing AP and MB tibial components among obese patients who underwent UKA. However, among higher obesity patients (BMI ≥ 35 kg/m2), patients with AP tibial component were associated with lower KSKS score and a lower proportion of attaining satisfaction fulfillment 2 years postoperatively.
- 30 January 2022
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 142 (12) , 3977-3985
All-polyethylene unicompartmental knee arthroplasty is associated with increased risks of poorer knee society knee score and lower satisfaction in obese patients
Background Although metal-backed tibial component (MB) is biomechanically superior to all-polyethylene (AP) implants in fixed-bearing unicompartmental knee arthroplasty (UKA), recent studies have shown comparable functional outcomes between the two. However, no study has examined this comparison in obese patients (BMI ≥ 30 kg/m2). We investigated whether functional outcomes between the two implants differ among obese patients, and whether the extent of obesity influences these outcomes. Patients and methods Four hundred twenty-two UKA implants from 347 obese patients were reviewed retrospectively. Patients were assessed using the Knee Society Knee Score (KSKS) and Function Score (KSFS), the original Oxford Knee Score (OKS), and SF-36 Physical Component Summary (PCS) and Mental Component Summary (MCS). Minimal clinically important difference (MCID) attainment was recorded. Patients’ fulfillment of expectations and satisfaction with the surgery outcome was also graded. Patients were further divided into lower obesity (BMI 30–34.9 kg/m2) and higher obesity (BMI ≥ 35 kg/m2) to examine effect modification. Results There were no differences in functional outcomes and quality-of-life scores, MCID attainment of functional scores, as well as satisfaction and expectation fulfillment between AP and MB. Among higher obesity patients, AP was associated with a poorer KSKS (p = 0.031) and lower proportion of satisfaction fulfillment (p = 0.041) 2 years postoperatively compared to MB. Conclusion We found no differences in functional and quality-of-life outcomes between fixed-bearing AP and MB tibial components among obese patients who underwent UKA. However, among higher obesity patients (BMI ≥ 35 kg/m2), patients with AP tibial component were associated with lower KSKS score and a lower proportion of attaining satisfaction fulfillment 2 years postoperatively.