Masahiro Kawakami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Masahiro Kawakami has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Masaru Kojima
Department of Materials Engineering Science, Osaka University, Toyonaka, Osaka, JAPAN
3 shared publications - Shinji Sakai
Division of Chemical Engineering, Department of Materials Engineering Science, Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama-cho, Toyonaka, Osaka 560-8531, Japan
2 shared publications - Atsushi Kubo
Graduate School of Pharmaceutical Sciences, The University of Osaka, 1-6 Yamadaoka, Suita 565-0871, Osaka, Japan
1 shared publication Masaki Nakahata
Department of Materials Engineering Science Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka, Japan
1 shared publication- Satoshi Yamaguchi
SANKEN, The University of Osaka, 8-1 Mihogaoka, Ibaraki-shi, Osaka 567-0047, Japan
1 shared publication Shinji Sakai
Department of Materials Engineering Science Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka, Japan
1 shared publication
Latest Publications
- Open Access
- 6 January 2026
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 27 (2) , 562
Photocontrol of Non-Adherent Cell Adhesion via Azobenzene–PEG–Lipid/Cyclodextrin Host–Guest Interactions
Controlling cell attachment to substrates with spatiotemporal precision is a key technological foundation in fields such as tissue engineering, cell sorting, and cell–cell interaction analysis. Among existing approaches, azobenzene-based photocontrollable systems offer a promising strategy for the reversible regulation of cell adhesion. However, most conventional systems rely on the intrinsic adhesion capacity of adherent cells. Consequently, although the importance of non-adherent cell types has grown in biomedical research, their dynamic manipulation remains insufficiently explored. In this study, we developed a versatile system to control cell adhesion based on host–guest interactions between an azobenzene–lipid conjugate and a cyclodextrin-functionalized substrate. Using human chronic myelogenous leukemia (K562) cells, we successfully demonstrated photocontrolled adhesion and detachment, confirming the applicability of this system to non-adherent cells. Furthermore, we quantitatively measured the adhesion force and observed an inverse correlation between adhesion efficiency and adhesion force for different PEG linker lengths (2k, 4k, and 8k). This finding demonstrates the critical role of the linker length in effective cell surface modification. In conclusion, the proposed system establishes a photocontrollable adhesion method applicable to non-adherent cells, demonstrating its potential as a versatile technology for broad applications.
- 6 January 2026
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 27 (2) , 562
Open AccessPhotocontrol of Non-Adherent Cell Adhesion via Azobenzene–PEG–Lipid/Cyclodextrin Host–Guest Interactions
Controlling cell attachment to substrates with spatiotemporal precision is a key technological foundation in fields such as tissue engineering, cell sorting, and cell–cell interaction analysis. Among existing approaches, azobenzene-based photocontrollable systems offer a promising strategy for the reversible regulation of cell adhesion. However, most conventional systems rely on the intrinsic adhesion capacity of adherent cells. Consequently, although the importance of non-adherent cell types has grown in biomedical research, their dynamic manipulation remains insufficiently explored. In this study, we developed a versatile system to control cell adhesion based on host–guest interactions between an azobenzene–lipid conjugate and a cyclodextrin-functionalized substrate. Using human chronic myelogenous leukemia (K562) cells, we successfully demonstrated photocontrolled adhesion and detachment, confirming the applicability of this system to non-adherent cells. Furthermore, we quantitatively measured the adhesion force and observed an inverse correlation between adhesion efficiency and adhesion force for different PEG linker lengths (2k, 4k, and 8k). This finding demonstrates the critical role of the linker length in effective cell surface modification. In conclusion, the proposed system establishes a photocontrollable adhesion method applicable to non-adherent cells, demonstrating its potential as a versatile technology for broad applications.
- Open Access
- 12 November 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (11) , 1272
Microhand Platform Equipped with Plate-Shaped End-Effectors Enables Precise Probing of Intracellular Structure Contribution to Whole-Cell Mechanical Properties
Cellular mechanical properties are critical indicators of cellular state and promising disease biomarkers. This study introduces a novel microhand system, featuring chopstick-like plate-shaped end-effectors, designed for stable and high-precision single-cell mechanical characterization. First, we automated the force sensor calibration to overcome the inefficiency and unreliability of conventional manual methods. To validate the system’s sensitivity, we precisely quantified the mechanical contributions of subcellular components, such as the actin cytoskeleton and chromatin, by measuring stiffness reductions after treatment with Cytochalasin D and Trichostatin A, respectively. Notably, when applied to a cellular model of Hutchinson–Gilford progeria syndrome, we successfully captured disease-induced mechanical alterations. A distinct population of high-stiffness cells was detected in progerin-overexpressing cells, a feature not observed in the control groups. Furthermore, by controlling the indentation speed and depth, the mechanical properties of the cytoplasm and nucleus could be distinctly evaluated. These results demonstrate that our microhand system is a highly sensitive and robust platform, capable of detecting subtle, disease-related changes and elucidating the contributions of specific subcellular structures to cell mechanics.
- 12 November 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (11) , 1272
Open AccessMicrohand Platform Equipped with Plate-Shaped End-Effectors Enables Precise Probing of Intracellular Structure Contribution to Whole-Cell Mechanical Properties
Cellular mechanical properties are critical indicators of cellular state and promising disease biomarkers. This study introduces a novel microhand system, featuring chopstick-like plate-shaped end-effectors, designed for stable and high-precision single-cell mechanical characterization. First, we automated the force sensor calibration to overcome the inefficiency and unreliability of conventional manual methods. To validate the system’s sensitivity, we precisely quantified the mechanical contributions of subcellular components, such as the actin cytoskeleton and chromatin, by measuring stiffness reductions after treatment with Cytochalasin D and Trichostatin A, respectively. Notably, when applied to a cellular model of Hutchinson–Gilford progeria syndrome, we successfully captured disease-induced mechanical alterations. A distinct population of high-stiffness cells was detected in progerin-overexpressing cells, a feature not observed in the control groups. Furthermore, by controlling the indentation speed and depth, the mechanical properties of the cytoplasm and nucleus could be distinctly evaluated. These results demonstrate that our microhand system is a highly sensitive and robust platform, capable of detecting subtle, disease-related changes and elucidating the contributions of specific subcellular structures to cell mechanics.
- 14 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (2) , 2385-2390
Automated Microhand System for Measuring Cell Stiffness By Using Two Plate End-Effectors
With the advancements in the field of life sciences, there is an increasing demand for measuring cell characteristics. In this context, we developed a small microhand system that uses two end-effectors, such as chopsticks, to grasp and carry micro-objects. In addition, we succeeded in measuring the stiffness of cells by installing a micro force sensor on the end-effector tip for measuring the reaction force during grasping. However, the stiffness measurement of micro-objects requires precise manipulation and places a significant burden on the experimenter. The problem with the previous system was it required a skilled technician to perform accurate measurements, and there was a limit to the number of cells that were measured in a single short experimental time suitable for characterizing cells. To address this problem, we introduced a simultaneous observation system that included microscopes of different magnifications and optical tweezers. Furthermore, to render stiffness measurement easier, we automated each measurement process. Through evaluation experiments, we confirmed that the system can measure the stiffness of cells with the same speed and high accuracy as the previous system.
- 14 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (2) , 2385-2390
Automated Microhand System for Measuring Cell Stiffness By Using Two Plate End-Effectors
With the advancements in the field of life sciences, there is an increasing demand for measuring cell characteristics. In this context, we developed a small microhand system that uses two end-effectors, such as chopsticks, to grasp and carry micro-objects. In addition, we succeeded in measuring the stiffness of cells by installing a micro force sensor on the end-effector tip for measuring the reaction force during grasping. However, the stiffness measurement of micro-objects requires precise manipulation and places a significant burden on the experimenter. The problem with the previous system was it required a skilled technician to perform accurate measurements, and there was a limit to the number of cells that were measured in a single short experimental time suitable for characterizing cells. To address this problem, we introduced a simultaneous observation system that included microscopes of different magnifications and optical tweezers. Furthermore, to render stiffness measurement easier, we automated each measurement process. Through evaluation experiments, we confirmed that the system can measure the stiffness of cells with the same speed and high accuracy as the previous system.