Sharon Ho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sharon Ho has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Angelica Ly
School of Optometry and Vision Science, UNSW Sydney, Sydney, Australia
5 shared publications - Gordon Stuart Doig
Northern Clinical School Intensive Care Research Unit, Sydney Medical School, University of Sydney, Sydney, Australia
2 shared publications - Michael Kalloniatis
University of Houston College of Optometry Houston Texas USA
2 shared publications Angelica Ly
Centre for Eye Health, UNSW Medicine and Health, University of New South Wales, Sydney, Australia
1 shared publication- Arcot Sowmya
University of New South Wales
1 shared publication Gordon S. Doig
Centre for Eye Health The University of New South Wales Sydney New South Wales Australia
1 shared publication
Latest Publications
- Open Access
- 3 November 2023
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 44 (1) , 17-22
Diagnostic accuracy of community optometrists for age‐related macular degeneration using colour fundus photographs: A pilot evaluation
Purpose: The accurate diagnosis of age‐related macular degeneration (AMD) represents an important step in delaying and preventing vision loss and achieving optimal patient care. Therefore, this pilot study aimed to estimate the diagnostic accuracy of community optometrists for identifying AMD using colour fundus photographs (CFPs) to support sample size calculations for subsequent definitive studies. Methods: Five practising community optometrists were invited to classify a total of 1023 CFPs for the (1) presence of AMD, and, if applicable, (2) stage of AMD (early/intermediate/late geographic atrophy/late neovascular AMD). Diagnosis by referral centre clinicians formed the reference standard. Diagnostic accuracy was assessed by the area under the receiver operating characteristic curve (aROC). Sensitivity, specificity, positive and negative predictive values were also calculated. Results: Of the 1023 CFPs included in the study, 226 images were of AMD and 797 images were of other ocular conditions or no abnormal findings. Participating community optometrists had a mean (SD) age of 30.2 (8.9) years, 60.0% (3/5) were female and the mean number of years practising in primary eye care was 5.4 (5.4) years. Community optometrists demonstrated excellent performance for diagnosing AMD, with an aROC of 0.86 (95% CI 0.83 to 0.89), sensitivity of 84.5% (95% CI 79.1 to 89.0) and specificity of 88.0% (95% CI 85.5 to 90.1). The aROC (95% CI) for diagnosing early, intermediate, late geographic atrophy and late neovascular AMD was 0.82 (0.73 to 0.91), 0.76 (0.72 to 0.81), 0.69 (0.49 to 0.90) and 0.55 (0.34 to 0.75), respectively. Conclusions: These results justify the need for an appropriately powered definitive study to assess community clinicians' diagnostic accuracy for AMD.
- 3 November 2023
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 44 (1) , 17-22
Open AccessDiagnostic accuracy of community optometrists for age‐related macular degeneration using colour fundus photographs: A pilot evaluation
Purpose: The accurate diagnosis of age‐related macular degeneration (AMD) represents an important step in delaying and preventing vision loss and achieving optimal patient care. Therefore, this pilot study aimed to estimate the diagnostic accuracy of community optometrists for identifying AMD using colour fundus photographs (CFPs) to support sample size calculations for subsequent definitive studies. Methods: Five practising community optometrists were invited to classify a total of 1023 CFPs for the (1) presence of AMD, and, if applicable, (2) stage of AMD (early/intermediate/late geographic atrophy/late neovascular AMD). Diagnosis by referral centre clinicians formed the reference standard. Diagnostic accuracy was assessed by the area under the receiver operating characteristic curve (aROC). Sensitivity, specificity, positive and negative predictive values were also calculated. Results: Of the 1023 CFPs included in the study, 226 images were of AMD and 797 images were of other ocular conditions or no abnormal findings. Participating community optometrists had a mean (SD) age of 30.2 (8.9) years, 60.0% (3/5) were female and the mean number of years practising in primary eye care was 5.4 (5.4) years. Community optometrists demonstrated excellent performance for diagnosing AMD, with an aROC of 0.86 (95% CI 0.83 to 0.89), sensitivity of 84.5% (95% CI 79.1 to 89.0) and specificity of 88.0% (95% CI 85.5 to 90.1). The aROC (95% CI) for diagnosing early, intermediate, late geographic atrophy and late neovascular AMD was 0.82 (0.73 to 0.91), 0.76 (0.72 to 0.81), 0.69 (0.49 to 0.90) and 0.55 (0.34 to 0.75), respectively. Conclusions: These results justify the need for an appropriately powered definitive study to assess community clinicians' diagnostic accuracy for AMD.
- Open Access
- 21 April 2023
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 43 (4) , 905-915
Optometrists' attitudes toward using OCT angiography lag behind other retinal imaging types
Purpose: While optometrists' attitudes toward established retinal imaging types are generally positive, they are unknown for optical coherence tomography angiography (OCTA). We performed a cross‐sectional survey to estimate attitudes toward OCTA and identify clinician and/or practice characteristics that influence them. Methods: A paper‐based survey was mailed to 252 randomly selected optometrists in Australia. Five‐point Likert‐scale items from a previous survey assessing attitudes toward new technology were included to probe respondent characteristics and attitudes toward retinal imaging. Performance expectancy attitudes toward OCTA were elicited by the statement ‘I believe OCTA is useful in daily practice’. Mean scores out of five (mean [SD]) were rounded and mapped to appropriate descriptive statements. Results: The response rate was 47% (118/252). The mean (SD) age of respondents was 44.0 (13.8) years and 50.8% (60/118) were female. Optometrists had 19.9 (14.0) years of clinical experience and 66.9% (79/118) worked at independent practices. In total, 8.5% (10/118) of respondents used OCTA to provide clinical care. Optometrists agreed that optical coherence tomography (OCT), colour fundus imaging, ultra‐wide field imaging and fundus autofluorescence (mean scores 3.6–4.7 out of 5) were useful in daily practice but felt neutral about whether OCTA was useful (3.4 [0.8]). Optometrists believed that OCTA was less enjoyable to use ( p < 0.0001), less endorsed by peers ( p < 0.0001) and felt less confident that they had the knowledge to interpret OCTA ( p < 0.0001) compared to other retinal imaging types. Conclusions: Optometrists are undecided on whether OCTA is useful in daily practice and had lower expectations that using OCTA would confer job performance benefits compared to other retinal imaging types. Further work is needed to advocate the benefits of using OCTA across the profession.
- 21 April 2023
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 43 (4) , 905-915
Open AccessOptometrists' attitudes toward using OCT angiography lag behind other retinal imaging types
Purpose: While optometrists' attitudes toward established retinal imaging types are generally positive, they are unknown for optical coherence tomography angiography (OCTA). We performed a cross‐sectional survey to estimate attitudes toward OCTA and identify clinician and/or practice characteristics that influence them. Methods: A paper‐based survey was mailed to 252 randomly selected optometrists in Australia. Five‐point Likert‐scale items from a previous survey assessing attitudes toward new technology were included to probe respondent characteristics and attitudes toward retinal imaging. Performance expectancy attitudes toward OCTA were elicited by the statement ‘I believe OCTA is useful in daily practice’. Mean scores out of five (mean [SD]) were rounded and mapped to appropriate descriptive statements. Results: The response rate was 47% (118/252). The mean (SD) age of respondents was 44.0 (13.8) years and 50.8% (60/118) were female. Optometrists had 19.9 (14.0) years of clinical experience and 66.9% (79/118) worked at independent practices. In total, 8.5% (10/118) of respondents used OCTA to provide clinical care. Optometrists agreed that optical coherence tomography (OCT), colour fundus imaging, ultra‐wide field imaging and fundus autofluorescence (mean scores 3.6–4.7 out of 5) were useful in daily practice but felt neutral about whether OCTA was useful (3.4 [0.8]). Optometrists believed that OCTA was less enjoyable to use ( p < 0.0001), less endorsed by peers ( p < 0.0001) and felt less confident that they had the knowledge to interpret OCTA ( p < 0.0001) compared to other retinal imaging types. Conclusions: Optometrists are undecided on whether OCTA is useful in daily practice and had lower expectations that using OCTA would confer job performance benefits compared to other retinal imaging types. Further work is needed to advocate the benefits of using OCTA across the profession.
- Open Access
- 14 February 2023
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 43 (4) , 668-679
Drusen‐aware model for age‐related macular degeneration recognition
Introduction: The purpose of this study was to build an automated age‐related macular degeneration (AMD) colour fundus photography (CFP) recognition method that incorporates confounders (other ocular diseases) and normal age‐related changes by using drusen masks for spatial feature supervision. Methods: A range of clinical sources were used to acquire 7588 CFPs. Contrast limited adaptive histogram equalisation was used for pre‐processing. ResNet50 was used as the backbone network, and a spatial attention block was added to integrate prior knowledge of drusen features into the backbone. The evaluation metrics used were sensitivity, specificity and F1 score, which is the harmonic mean of precision and recall (sensitivity) and area under the receiver‐operating characteristic (AUC). Fivefold cross‐validation was performed, and the results compared with four other methods. Results: Excellent discrimination results were obtained with the algorithm. On the public dataset ( n = 6565), the proposed method achieved a mean (SD) sensitivity of 0.54 (0.09), specificity of 0.99 (0.00), F1 score of 0.62 (0.06) and AUC of 0.92 (0.02). On the private dataset ( n = 1023), the proposed method achieved a sensitivity of 0.92 (0.02), specificity of 0.98 (0.01), F1 score of 0.92 (0.01) and AUC of 0.98 (0.01). Conclusion: The proposed drusen‐aware model outperformed baseline and other vessel feature‐based methods in F1 and AUC on the AMD/normal CFP classification task and achieved comparable results on datasets that included other diseases that often confound classification. The method also improved results when a five‐category grading protocol was used, thereby reflecting discriminative ability of the algorithm within a real‐life clinical setting.
- 14 February 2023
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 43 (4) , 668-679
Open AccessDrusen‐aware model for age‐related macular degeneration recognition
Introduction: The purpose of this study was to build an automated age‐related macular degeneration (AMD) colour fundus photography (CFP) recognition method that incorporates confounders (other ocular diseases) and normal age‐related changes by using drusen masks for spatial feature supervision. Methods: A range of clinical sources were used to acquire 7588 CFPs. Contrast limited adaptive histogram equalisation was used for pre‐processing. ResNet50 was used as the backbone network, and a spatial attention block was added to integrate prior knowledge of drusen features into the backbone. The evaluation metrics used were sensitivity, specificity and F1 score, which is the harmonic mean of precision and recall (sensitivity) and area under the receiver‐operating characteristic (AUC). Fivefold cross‐validation was performed, and the results compared with four other methods. Results: Excellent discrimination results were obtained with the algorithm. On the public dataset ( n = 6565), the proposed method achieved a mean (SD) sensitivity of 0.54 (0.09), specificity of 0.99 (0.00), F1 score of 0.62 (0.06) and AUC of 0.92 (0.02). On the private dataset ( n = 1023), the proposed method achieved a sensitivity of 0.92 (0.02), specificity of 0.98 (0.01), F1 score of 0.92 (0.01) and AUC of 0.98 (0.01). Conclusion: The proposed drusen‐aware model outperformed baseline and other vessel feature‐based methods in F1 and AUC on the AMD/normal CFP classification task and achieved comparable results on datasets that included other diseases that often confound classification. The method also improved results when a five‐category grading protocol was used, thereby reflecting discriminative ability of the algorithm within a real‐life clinical setting.
- Open Access
- 2 December 2022
- Published by Springer Nature in Eye
- Vol. 37 (1) , 21-29
Diagnostic accuracy of OCTA and OCT for myopic choroidal neovascularisation: a systematic review and meta-analysis
Learning Objectives Upon completion of this activity, participants will be able to: 1. Describe test accuracy, pooled sensitivity and pooled specificity of optical coherence tomography angiography (OCTA) and spectral domain (SD)-OCT in diagnosing myopic choroidal neovascularization (mCNV) compared with fluorescein angiography (FA) as the reference standard, according to a meta-analysis. 2. Determine clinical recommendations for using OCTA and SD-OCT in diagnosing mCNV, according to a meta-analysis. 3. Identify other clinical and research implications of test accuracy, pooled sensitivity and pooled specificity of OCTA and SD-OCT in diagnosing mCNV compared with FA as the reference standard, according to a meta-analysis. Accreditation Statements In support of improving patient care, this activity has been planned and implemented by Medscape, LLC and Springer Nature. Medscape, LLC is jointly accredited with commendation by the Accreditation Council for Continuing Medical Education (ACCME), the Accreditation Council for Pharmacy Education (ACPE), and the American Nurses Credentialing Center (ANCC), to provide continuing education for the healthcare team. Medscape, LLC designates this Journal-based CME activity for a maximum of 1.0 AMA PRA Category 1 Credit(s)™. Physicians should claim only the credit commensurate with the extent of their participation in the activity. To participate in this journal CME activity: (1) review the learning objectives and author disclosures; (2) study the education content; (3) take the post-test with a 75% minimum passing score and complete the evaluation at http://www.medscape.org/journal/eye; (4) view/print certificate. Credit hours 1.0 Release date: Expiration date: Post-test link: https://medscape.org/eye/posttest978466 Journal CME author disclosure information Laurie Barclay, MD Freelance writer and reviewer, Medscape, LLC, and has disclosed the following relevant financial relationships: formerly owned stocks in AbbVie.
- 2 December 2022
- Published by Springer Nature in Eye
- Vol. 37 (1) , 21-29
Open AccessDiagnostic accuracy of OCTA and OCT for myopic choroidal neovascularisation: a systematic review and meta-analysis
Learning Objectives Upon completion of this activity, participants will be able to: 1. Describe test accuracy, pooled sensitivity and pooled specificity of optical coherence tomography angiography (OCTA) and spectral domain (SD)-OCT in diagnosing myopic choroidal neovascularization (mCNV) compared with fluorescein angiography (FA) as the reference standard, according to a meta-analysis. 2. Determine clinical recommendations for using OCTA and SD-OCT in diagnosing mCNV, according to a meta-analysis. 3. Identify other clinical and research implications of test accuracy, pooled sensitivity and pooled specificity of OCTA and SD-OCT in diagnosing mCNV compared with FA as the reference standard, according to a meta-analysis. Accreditation Statements In support of improving patient care, this activity has been planned and implemented by Medscape, LLC and Springer Nature. Medscape, LLC is jointly accredited with commendation by the Accreditation Council for Continuing Medical Education (ACCME), the Accreditation Council for Pharmacy Education (ACPE), and the American Nurses Credentialing Center (ANCC), to provide continuing education for the healthcare team. Medscape, LLC designates this Journal-based CME activity for a maximum of 1.0 AMA PRA Category 1 Credit(s)™. Physicians should claim only the credit commensurate with the extent of their participation in the activity. To participate in this journal CME activity: (1) review the learning objectives and author disclosures; (2) study the education content; (3) take the post-test with a 75% minimum passing score and complete the evaluation at http://www.medscape.org/journal/eye; (4) view/print certificate. Credit hours 1.0 Release date: Expiration date: Post-test link: https://medscape.org/eye/posttest978466 Journal CME author disclosure information Laurie Barclay, MD Freelance writer and reviewer, Medscape, LLC, and has disclosed the following relevant financial relationships: formerly owned stocks in AbbVie.
- Open Access
- 4 August 2022
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 42 (6) , 1170-1179
Attitudes of optometrists towards artificial intelligence for the diagnosis of retinal disease: A cross‐sectional mail‐out survey
Purpose: Artificial intelligence (AI)‐based systems have demonstrated great potential in improving the diagnostic accuracy of retinal disease but are yet to achieve widespread acceptance in routine clinical practice. Clinician attitudes are known to influence implementation. Therefore, this study aimed to identify optometrists' attitudes towards the use of AI to assist in diagnosing retinal disease. Methods: A paper‐based survey was designed to assess general attitudes towards AI in diagnosing retinal disease and motivators/barriers for future use. Two clinical scenarios for using AI were evaluated: (1) at the point of care to obtain a diagnostic recommendation, versus (2) after the consultation to provide a second opinion. Relationships between participant characteristics and attitudes towards AI were explored. The survey was mailed to 252 randomly selected practising optometrists across Australia, with repeat mail‐outs to non‐respondents. Results: The response rate was 53% (133/252). Respondents' mean (SD) age was 42.7 (13.3) years, and 44.4% (59/133) identified as female, whilst 1.5% (2/133) identified as gender diverse. The mean number of years practising in primary eye care was 18.8 (13.2) years with 64.7% (86/133) working in an independently owned practice. On average, responding optometrists reported positive attitudes (mean score 4.0 out of 5, SD 0.8) towards using AI as a tool to aid the diagnosis of retinal disease, and would be more likely to use AI if it is proven to increase patient access to healthcare (mean score 4.4 out of 5, SD 0.6). Furthermore, optometrists expressed a statistically significant preference for using AI after the consultation to provide a second opinion rather than during the consultation, at the point‐of‐care (+0.12, p = 0.01). Conclusions: Optometrists have positive attitudes towards the future use of AI as an aid to diagnose retinal disease. Understanding clinician attitudes and preferences for using AI may help maximise its clinical potential and ensure its successful translation into practice.
- 4 August 2022
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 42 (6) , 1170-1179
Open AccessAttitudes of optometrists towards artificial intelligence for the diagnosis of retinal disease: A cross‐sectional mail‐out survey
Purpose: Artificial intelligence (AI)‐based systems have demonstrated great potential in improving the diagnostic accuracy of retinal disease but are yet to achieve widespread acceptance in routine clinical practice. Clinician attitudes are known to influence implementation. Therefore, this study aimed to identify optometrists' attitudes towards the use of AI to assist in diagnosing retinal disease. Methods: A paper‐based survey was designed to assess general attitudes towards AI in diagnosing retinal disease and motivators/barriers for future use. Two clinical scenarios for using AI were evaluated: (1) at the point of care to obtain a diagnostic recommendation, versus (2) after the consultation to provide a second opinion. Relationships between participant characteristics and attitudes towards AI were explored. The survey was mailed to 252 randomly selected practising optometrists across Australia, with repeat mail‐outs to non‐respondents. Results: The response rate was 53% (133/252). Respondents' mean (SD) age was 42.7 (13.3) years, and 44.4% (59/133) identified as female, whilst 1.5% (2/133) identified as gender diverse. The mean number of years practising in primary eye care was 18.8 (13.2) years with 64.7% (86/133) working in an independently owned practice. On average, responding optometrists reported positive attitudes (mean score 4.0 out of 5, SD 0.8) towards using AI as a tool to aid the diagnosis of retinal disease, and would be more likely to use AI if it is proven to increase patient access to healthcare (mean score 4.4 out of 5, SD 0.6). Furthermore, optometrists expressed a statistically significant preference for using AI after the consultation to provide a second opinion rather than during the consultation, at the point‐of‐care (+0.12, p = 0.01). Conclusions: Optometrists have positive attitudes towards the future use of AI as an aid to diagnose retinal disease. Understanding clinician attitudes and preferences for using AI may help maximise its clinical potential and ensure its successful translation into practice.
- 13 January 2022
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 105 (6) , 562-572
Clinical decision support in primary care for better diagnosis and management of retinal disease
Misdiagnosis of retinal disease is a common problem in primary care that can lead to irreversible vision loss and false-positive referrals, resulting in inappropriate use of health services. Clinical decision support systems describe tools that leverage information technology to provide timely recommendations that assist clinicians in the decisions they make about the care of a patient. They, therefore, have the potential to reduce the rate of misdiagnosis by promoting evidence-based medicine and more effective and efficient healthcare. This narrative review aims to support primary care practitioners in better understanding the current and emerging capacity of clinical decision support systems in eye care. Different types of clinical decision support systems are discussed, using current examples and evidence from the available literature to demonstrate how they may improve diagnostic effectiveness and aid the management of retinal disease. Comments are made on the future directions of clinical decision support in primary eye care and the potential applications of artificial intelligence.
- 13 January 2022
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 105 (6) , 562-572
Clinical decision support in primary care for better diagnosis and management of retinal disease
Misdiagnosis of retinal disease is a common problem in primary care that can lead to irreversible vision loss and false-positive referrals, resulting in inappropriate use of health services. Clinical decision support systems describe tools that leverage information technology to provide timely recommendations that assist clinicians in the decisions they make about the care of a patient. They, therefore, have the potential to reduce the rate of misdiagnosis by promoting evidence-based medicine and more effective and efficient healthcare. This narrative review aims to support primary care practitioners in better understanding the current and emerging capacity of clinical decision support systems in eye care. Different types of clinical decision support systems are discussed, using current examples and evidence from the available literature to demonstrate how they may improve diagnostic effectiveness and aid the management of retinal disease. Comments are made on the future directions of clinical decision support in primary eye care and the potential applications of artificial intelligence.