Lenka Michalcová
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lenka Michalcová has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Zdeněk Glatz
Department of Biochemistry Faculty of Science Masaryk University Brno Czech Republic
6 shared publications Hana Mlčochová
Department of Biochemistry Faculty of Science Masaryk University Brno Czech Republic
3 shared publications- Hermann Wätzig
Institute of Medicinal and Pharmaceutical Chemistry Technische Universität Braunschweig Braunschweig Germany
2 shared publications - Taťána Bržezická
Department of Biochemistry Faculty of Science Masaryk University Brno Czech Republic
2 shared publications - Adel Ehab Ibrahim
Natural and Medical Sciences Research Center, University of Nizwa
1 shared publication - Marta Pelcová
Department of Biochemistry Faculty of Science Masaryk University Brno Czech Republic
1 shared publication
Latest Publications
- Open Access
- 9 November 2026
- Published by Wiley in Journal of Separation Science
- Vol. 49 (11)
Magnetic Microparticles With Immobilized Bovine Serum Albumin as a Stationary Phase for Affinity Studies Using Pressure‐Assisted Capillary Electrochromatography. Proof of Concept
This study presents a novel pressure‐assisted capillary electrochromatography method that uses a fritless capillary column of magnetic microparticles with immobilized serum albumin to investigate the affinity interactions of drugs with plasma proteins. To the authors' knowledge, this is the first time that this type of column has been used in a study examining the binding properties of a drug–serum albumin pair. The use of magnetic particles as the chromatographic bed material offers several advantages, such as easy handling during chemical activation and subsequent protein immobilization, and relatively simple column preparation achieved by external permanent magnets around the capillary. In addition, this concept is characterized by low protein and reagent consumption, which is typical for capillary electrochromatography. Glutaraldehyde coupling was chosen for its sufficient yield of immobilized bovine serum albumin (BSA) with preserved drug‐binding properties compared to the carbodiimide method. Furthermore, the required binding capacity was increased by optimizing the length of the particle bed, which was held in the capillary by 25 pairs of permanent magnets in an attractive orientation in a 3D‐printed holder positioned inside the capillary cartridge. After optimizing the immobilization procedure and the column preparation, the column was used to determine the binding parameters of the model drug phenylbutazone (PBZ) to the pharmacologically significant Sudlow I site on the BSA molecule. Frontal electrokinetic injection and breakthrough time analysis were employed for each PBZ concentration to estimate the corresponding equilibrium binding constant. The proposed approach could be particularly useful for studying the binding of drugs to expensive or rare proteins and support the choice of lead compounds in drug development studies.
- 9 November 2026
- Published by Wiley in Journal of Separation Science
- Vol. 49 (11)
Open AccessMagnetic Microparticles With Immobilized Bovine Serum Albumin as a Stationary Phase for Affinity Studies Using Pressure‐Assisted Capillary Electrochromatography. Proof of Concept
This study presents a novel pressure‐assisted capillary electrochromatography method that uses a fritless capillary column of magnetic microparticles with immobilized serum albumin to investigate the affinity interactions of drugs with plasma proteins. To the authors' knowledge, this is the first time that this type of column has been used in a study examining the binding properties of a drug–serum albumin pair. The use of magnetic particles as the chromatographic bed material offers several advantages, such as easy handling during chemical activation and subsequent protein immobilization, and relatively simple column preparation achieved by external permanent magnets around the capillary. In addition, this concept is characterized by low protein and reagent consumption, which is typical for capillary electrochromatography. Glutaraldehyde coupling was chosen for its sufficient yield of immobilized bovine serum albumin (BSA) with preserved drug‐binding properties compared to the carbodiimide method. Furthermore, the required binding capacity was increased by optimizing the length of the particle bed, which was held in the capillary by 25 pairs of permanent magnets in an attractive orientation in a 3D‐printed holder positioned inside the capillary cartridge. After optimizing the immobilization procedure and the column preparation, the column was used to determine the binding parameters of the model drug phenylbutazone (PBZ) to the pharmacologically significant Sudlow I site on the BSA molecule. Frontal electrokinetic injection and breakthrough time analysis were employed for each PBZ concentration to estimate the corresponding equilibrium binding constant. The proposed approach could be particularly useful for studying the binding of drugs to expensive or rare proteins and support the choice of lead compounds in drug development studies.
- Open Access
- 11 January 2024
- Published by Wiley in Journal of Separation Science
- Vol. 47 (1) , e2300667
Contactless conductivity detector as a tool for improving universality and sensitivity of capillary electrophoresis‐frontal analysis: Proof of concept
Drug binding to plasma proteins influences processes such as liberation, adsorption, disposition, metabolism, and elimination of drugs, which are thus one of the key steps of a new drug development. As a result, the characterization of drug–protein interactions is an essential part of these time‐ and money‐consuming processes. It is important to determine not only the binding strength and the stoichiometry of interaction, but also the binding site of a drug on a protein molecule, because two drugs with the same binding site can mutually affect free drug concentration. Capillary electrophoresis‐frontal analysis with mobility shift affinity capillary electrophoresis is one of the most used affinity capillary electrophoresis methods for the characterization of these interactions. In this study, a well‐known sensitivity problem of most capillary electrophoresis‐frontal analyses using ultraviolet detection is solved by its combination with contactless conductivity detection, which provided sixfold lower limits of quantitation and detection. Binding parameters of the human serum albumin‐salicylic acid model affinity pair were evaluated by this newly developed approach and by the classical approach with ultraviolet detection primarily used for their mutual comparison. The results of both approaches agreed well and are also in agreement with literature data obtained using different techniques.
- 11 January 2024
- Published by Wiley in Journal of Separation Science
- Vol. 47 (1) , e2300667
Open AccessContactless conductivity detector as a tool for improving universality and sensitivity of capillary electrophoresis‐frontal analysis: Proof of concept
Drug binding to plasma proteins influences processes such as liberation, adsorption, disposition, metabolism, and elimination of drugs, which are thus one of the key steps of a new drug development. As a result, the characterization of drug–protein interactions is an essential part of these time‐ and money‐consuming processes. It is important to determine not only the binding strength and the stoichiometry of interaction, but also the binding site of a drug on a protein molecule, because two drugs with the same binding site can mutually affect free drug concentration. Capillary electrophoresis‐frontal analysis with mobility shift affinity capillary electrophoresis is one of the most used affinity capillary electrophoresis methods for the characterization of these interactions. In this study, a well‐known sensitivity problem of most capillary electrophoresis‐frontal analyses using ultraviolet detection is solved by its combination with contactless conductivity detection, which provided sixfold lower limits of quantitation and detection. Binding parameters of the human serum albumin‐salicylic acid model affinity pair were evaluated by this newly developed approach and by the classical approach with ultraviolet detection primarily used for their mutual comparison. The results of both approaches agreed well and are also in agreement with literature data obtained using different techniques.
- Open Access
- 29 June 2023
- Published by Wiley in Journal of Separation Science
- Vol. 46 (17) , e2300152
Sensitivity enhancement of capillary electrophoresis‐frontal analysis‐based method for characterization of drug‐protein interactions using on‐line sample preconcentration
Capillary electrophoresis‐frontal analysis is one of the most frequently used approaches for the study of plasma protein‐drug interactions as a substantial part of new drug development. However, the capillary electrophoresis‐frontal analysis typically combined with ultraviolet‐visible detection suffers from insufficient concentration sensitivity, particularly for substances with limited solubility and low molar absorption coefficient. The sensitivity problem has been solved in this work by its combination with an on‐line sample preconcentration. According to the knowledge of the authors this combination has never been used to characterize plasma protein‐drug binding. It resulted in a fully automated and versatile methodology for the characterization of binding interactions. Further, the validated method minimalizes the experimental errors due to a reduction in the manipulation of samples. Moreover, employing an on‐line preconcentration strategy with capillary electrophoresis‐frontal analysis using human serum albumin‐salicylic acid as a model system improves the drug concentration sensitivity 17‐fold compared to the conventional method. The value of binding constant (1.51 ± 0.63) · 104 L/mol obtained by this new capillary electrophoresis‐frontal analysis modification is in agreement with the value (1.13 ± 0.28) ·104 L/mol estimated by a conventional variant of capillary electrophoresis‐frontal analysis without the preconcentration step, as well as with literature data obtained using different techniques.
- 29 June 2023
- Published by Wiley in Journal of Separation Science
- Vol. 46 (17) , e2300152
Open AccessSensitivity enhancement of capillary electrophoresis‐frontal analysis‐based method for characterization of drug‐protein interactions using on‐line sample preconcentration
Capillary electrophoresis‐frontal analysis is one of the most frequently used approaches for the study of plasma protein‐drug interactions as a substantial part of new drug development. However, the capillary electrophoresis‐frontal analysis typically combined with ultraviolet‐visible detection suffers from insufficient concentration sensitivity, particularly for substances with limited solubility and low molar absorption coefficient. The sensitivity problem has been solved in this work by its combination with an on‐line sample preconcentration. According to the knowledge of the authors this combination has never been used to characterize plasma protein‐drug binding. It resulted in a fully automated and versatile methodology for the characterization of binding interactions. Further, the validated method minimalizes the experimental errors due to a reduction in the manipulation of samples. Moreover, employing an on‐line preconcentration strategy with capillary electrophoresis‐frontal analysis using human serum albumin‐salicylic acid as a model system improves the drug concentration sensitivity 17‐fold compared to the conventional method. The value of binding constant (1.51 ± 0.63) · 104 L/mol obtained by this new capillary electrophoresis‐frontal analysis modification is in agreement with the value (1.13 ± 0.28) ·104 L/mol estimated by a conventional variant of capillary electrophoresis‐frontal analysis without the preconcentration step, as well as with literature data obtained using different techniques.
- Open Access
- 24 April 2023
- Published by Wiley in Electrophoresis
- Vol. 44 (13-14) , 1114-1142
Studying molecular interactions via capillary electrophoresis and microscale thermophoresis: A review
The process of choosing the most proper technique for studying the molecular interactions is based on critical factors such as instrumentation complexity, automation, experimental procedures, analysis time, consumables, and cost‐value. This review has tracked the use of affinity capillary electrophoresis (ACE) and microscale thermophoresis (MST) techniques in the evaluation of molecular binding among different molecules during the 5 years 2016–2021. ACE has proved to be an attractive technique for biomolecular characterization with high resolution efficiency where small variations in several controlling factors can much improve such efficiency compared to other analytical techniques. Meanwhile, MST has proved its higher sensitivity for smaller amounts of complex non‐purified biosamples without affecting its robustness while providing high through output. However, the main motivation to review both techniques in the proposed review was their capability to carry out all experiments without the need for immobilizing one interacting partner, besides a great flexibility in the use of buffering systems. The proposed review demonstrates the importance of both techniques in different areas of life sciences. Moreover, the recent advances in exploiting ACE and MST in other research interests have been discussed.
- 24 April 2023
- Published by Wiley in Electrophoresis
- Vol. 44 (13-14) , 1114-1142
Open AccessStudying molecular interactions via capillary electrophoresis and microscale thermophoresis: A review
The process of choosing the most proper technique for studying the molecular interactions is based on critical factors such as instrumentation complexity, automation, experimental procedures, analysis time, consumables, and cost‐value. This review has tracked the use of affinity capillary electrophoresis (ACE) and microscale thermophoresis (MST) techniques in the evaluation of molecular binding among different molecules during the 5 years 2016–2021. ACE has proved to be an attractive technique for biomolecular characterization with high resolution efficiency where small variations in several controlling factors can much improve such efficiency compared to other analytical techniques. Meanwhile, MST has proved its higher sensitivity for smaller amounts of complex non‐purified biosamples without affecting its robustness while providing high through output. However, the main motivation to review both techniques in the proposed review was their capability to carry out all experiments without the need for immobilizing one interacting partner, besides a great flexibility in the use of buffering systems. The proposed review demonstrates the importance of both techniques in different areas of life sciences. Moreover, the recent advances in exploiting ACE and MST in other research interests have been discussed.
- Open Access
- 8 July 2022
- Published by Wiley in Electrophoresis
- Vol. 43 (16-17) , 1724-1734
Comparison of mobility shift affinity capillary electrophoresis and capillary electrophoresis frontal analysis for binding constant determination between human serum albumin and small drugs
In this study, two capillary electrophoresis–based ligand binding assays, namely, mobility shift affinity capillary electrophoresis (ms‐ACE) and capillary electrophoresis‐frontal analysis (CE‐FA), were applied to determine binding parameters of human serum albumin toward small drugs under similar experimental conditions. The substances S‐amlodipine (S‐AML), lidocaine (LDC), l‐tryptophan (l‐TRP), carbamazepine (CBZ), ibuprofen (IBU), and R‐verapamil (R‐VPM) were used as the main binding partners. The scope of this comparative study was to estimate and compare both the assays in terms of their primary measure's precision and the reproducibility of the derived binding parameters. The effective mobility could be measured with pooled CV values between 0.55% and 7.6%. The precision of the r values was found in the range between 1.5% and 10%. Both assays were not universally applicable. The CE‐FA assay could successfully be applied to measure the drugs IBU, CBZ, and LDC, and the interaction toward CBZ, S‐AML, l‐TRP, and R‐VPM could be determined using ms‐ACE. The average variabilities of the estimated binding constants were 64% and 67% for CE‐FA and ms‐ACE, respectively.
- 8 July 2022
- Published by Wiley in Electrophoresis
- Vol. 43 (16-17) , 1724-1734
Open AccessComparison of mobility shift affinity capillary electrophoresis and capillary electrophoresis frontal analysis for binding constant determination between human serum albumin and small drugs
In this study, two capillary electrophoresis–based ligand binding assays, namely, mobility shift affinity capillary electrophoresis (ms‐ACE) and capillary electrophoresis‐frontal analysis (CE‐FA), were applied to determine binding parameters of human serum albumin toward small drugs under similar experimental conditions. The substances S‐amlodipine (S‐AML), lidocaine (LDC), l‐tryptophan (l‐TRP), carbamazepine (CBZ), ibuprofen (IBU), and R‐verapamil (R‐VPM) were used as the main binding partners. The scope of this comparative study was to estimate and compare both the assays in terms of their primary measure's precision and the reproducibility of the derived binding parameters. The effective mobility could be measured with pooled CV values between 0.55% and 7.6%. The precision of the r values was found in the range between 1.5% and 10%. Both assays were not universally applicable. The CE‐FA assay could successfully be applied to measure the drugs IBU, CBZ, and LDC, and the interaction toward CBZ, S‐AML, l‐TRP, and R‐VPM could be determined using ms‐ACE. The average variabilities of the estimated binding constants were 64% and 67% for CE‐FA and ms‐ACE, respectively.
- 12 January 2022
- Published by Wiley in Electrophoresis
- Vol. 43 (9-10) , 955-963
Extending the application potential of capillary electrophoresis/frontal analysis for drug‐plasma protein studies by combining it with mass spectrometry detection
CE/frontal analysis (CE/FA) is probably one of the most frequently used modes of CE for studying affinity interactions. It is typically performed with classic UV‐Vis detection that suffers from low concentration sensitivity. To overcome this limitation, the applicability of CE/FA in combination with ESI‐MS detection for the investigation of drug–HSA interactions was demonstrated. The developed new method combines the advantages of CE/FA, such as low sample consumption and no labeling or immobilization of interacting partners, with the benefits of MS detection, such as higher selectivity and sensitivity; moreover, it can be used for molecules lacking a fluorophore or chromophore. The binding parameters of tolbutamide (TL) and glimepiride (GLP), first‐ and second‐generation antidiabetics that differ strongly in their solubility in aqueous solutions, were investigated by this CE/FA‐MS method. This method, in contrast to the CE/FA method with the most commonly used UV‐Vis detection, is more sensitive; an almost three times lower LOD was reached. The binding parameters of TL and GLP were investigated by this CE/FA‐MS method and compared with the literature data. The binding constant value of TL obtained by UV‐Vis detection was lower than the value obtained by the method hyphenated with MS detection, which is probably given by the influence of the ESI parameters on the stability of drug–HSA complex. In addition, the ratio of TL and HSA concentrations was divergent in both of the experimental approaches. Finally, it can be concluded that both detection methods have their strengths and weaknesses.
- 12 January 2022
- Published by Wiley in Electrophoresis
- Vol. 43 (9-10) , 955-963
Extending the application potential of capillary electrophoresis/frontal analysis for drug‐plasma protein studies by combining it with mass spectrometry detection
CE/frontal analysis (CE/FA) is probably one of the most frequently used modes of CE for studying affinity interactions. It is typically performed with classic UV‐Vis detection that suffers from low concentration sensitivity. To overcome this limitation, the applicability of CE/FA in combination with ESI‐MS detection for the investigation of drug–HSA interactions was demonstrated. The developed new method combines the advantages of CE/FA, such as low sample consumption and no labeling or immobilization of interacting partners, with the benefits of MS detection, such as higher selectivity and sensitivity; moreover, it can be used for molecules lacking a fluorophore or chromophore. The binding parameters of tolbutamide (TL) and glimepiride (GLP), first‐ and second‐generation antidiabetics that differ strongly in their solubility in aqueous solutions, were investigated by this CE/FA‐MS method. This method, in contrast to the CE/FA method with the most commonly used UV‐Vis detection, is more sensitive; an almost three times lower LOD was reached. The binding parameters of TL and GLP were investigated by this CE/FA‐MS method and compared with the literature data. The binding constant value of TL obtained by UV‐Vis detection was lower than the value obtained by the method hyphenated with MS detection, which is probably given by the influence of the ESI parameters on the stability of drug–HSA complex. In addition, the ratio of TL and HSA concentrations was divergent in both of the experimental approaches. Finally, it can be concluded that both detection methods have their strengths and weaknesses.