    Interactive Lesion Segmentation in Whole-Body PET/CT and Longitudinal CT: The autoPET/CT-IV Challenge

    by Pauline Ornela Megne Choudja, Jakob Dexl, Zdravko Marinov, Niels Rocholl, Temke Kohlbrandt, Antoine Sanner, Katharina Jeblick, Balthasar Schachtner, Andreas Mittermeier, Anna Theresa Stüber, et al.

    Deep learning enables automated tumour segmentation in whole-body positron emission tomography and computed tomography, but robustness remains limited by heterogeneous tracer uptake, anatomical variability, and inter-center differences. We report the fourth autoPET challenge, which evaluated interactive lesion segmentation using incremental simulated user prompts and longitudinal lesion segmentation from paired baseline and follow-up scans. In the interactive task (Task 1, ~ 30,000 training and ~ 3,000 test lesions), submitted methods improved with additional user input and achieved a mean Dice similarity coefficient of 0.74 at the final interaction step, with performance remaining robust across tracers and centers. Longitudinal segmentation (Task 2, ~ 7,500 training and ~ 4,500 test lesions) was substantially more challenging, with a best mean Dice similarity coefficient of 0.38. Here, we show that interactive segmentation can combine automated inference with iterative expert input while maintaining performance across heterogeneous imaging domains, whereas longitudinal lesion prediction remains limited by temporal and anatomical variability.

  • Open Access

    Deep Learning Reconstruction Enables Substantial Radiation Dose Reduction in Ultra-High-Resolution Temporal Bone CT: a Body Donor Study

    by Lavinia Brockstedt, Sebastian Altmann, Suam Kim, Mohammed Beshr, Andrea Kronfeld, Michael J Schmeisser, Sven Schumann, Filip Pavlas, Antoine Sanner, Marc A Brockmann, et al.

    Purpose: Deep learning reconstruction may enable substantial radiation dose reduction in ultra–high-resolution (UHR) temporal bone CT, but its performance across clinically relevant dose levels remains insufficiently defined. This study evaluated vendor-specific deep learning reconstruction (DLR) compared with hybrid iterative reconstruction (HIR) in UHR volume-mode temporal bone CT and aimed to propose an indication-adapted framework for dose optimization. Methods: In this single-center body donor study, 20 temporal bones from 10 donors without pathologic findings were scanned at 11 dose levels (CTDI vol , 5.1–30.7 mGy). Images were reconstructed using HIR at standard resolution (0.5 mm, 512 2 matrix) and UHR (0.25 mm, 1024 2 and 2048 2 matrices), as well as DLR (AiCE Inner Ear) at UHR (0.25 mm, 1024 2 matrix). Three radiologists independently assessed 10 anatomical structures using a 5-point Likert scale. Signal-to-noise ratio was measured in predefined regions. Exploratory structure-specific generalized estimating equation models were used to estimate the probability of achieving optimal image quality as a function of radiation dose and reconstruction technique. Results: DLR significantly improved visualization of osseous structures compared with HIR ( p < 0.001). The exploratory dose-response analysis demonstrated reconstruction-specific trajectories, with DLR achieving higher predicted probabilities of optimal image quality than HIR at lower dose levels. For routine clinical indications, diagnostically adequate image quality was achieved with DLR at a CTDI vol of 13.3 mGy, representing a 48% dose reduction compared with HIR (CTDI vol 25.6 mGy). For high-detail assessment of delicate microanatomical structures, including the stapes and cochlea, DLR achieved excellent visualization at a CTDI vol of 17.4 mGy, corresponding to a 43% dose reduction compared with HIR (CTDI vol 30.7 mGy). Conclusion: Vendor-specific DLR enables substantial radiation dose reduction in UHR volume-mode temporal bone CT while maintaining high diagnostic image quality. These findings support an indication-adapted framework for dose optimization, suggesting a routine clinical protocol at CTDI vol 13.3 mGy and a microanatomy-optimized protocol at CTDI vol 17.4 mGy.

  • Open Access

    Semi-quantitative analyses of muscle magnetic resonance imaging for pattern recognition in early idiopathic inflammatory myopathies

    by Yana Leven, Suam Kim, Antoine Sanner, Fatma Merzou, Sergio Groppa, Christopher Nelke, Ahmed Othman, Andreas Deistung, Benjamin Troppa, Alexander Mensch, et al.

    Background: Idiopathic inflammatory myopathies (IIM) are a group of autoimmune diseases characterized by skeletal muscle inflammation. Magnetic resonance imaging (MRI) is increasingly used in IIM diagnosis, yet standardized protocols and comprehensive datasets remain limited. This study aimed to characterize MRI findings across IIM subtypes, identify muscle involvement patterns, and assess correlations between imaging abnormalities and clinical severity. Methods: In this retrospective cohort study, 34 patients with IIM evaluated between 2012 and 2020 in Düsseldorf and Halle (Germany) were included: Inclusion Body Myositis (IBM, n = 9), Dermatomyositis (DM, n = 5), Polymyositis (PM, n = 6), Anti-Synthetase Syndrome (ASYS, n = 5), and Immune-mediated Necrotizing Myopathy (IMNM, n = 9). Clinical data (autoantibody status, creatine kinase [CK] levels, and muscle strength via Manual-Muscle-Testing-8 [MMT-8]) and muscle MRI findings were analysed. Muscle involvement patterns were characterized, and associations with clinical severity were evaluated using univariate linear regression. Results: MRI abnormalities were evident even in early disease stages (median disease duration: 7 months [IQR: 2–18]). Patterns of muscle involvement differed markedly across IIM subtypes; notably, ASYS and IBM showed minimal involvement of upper extremities. A significant correlation was found between MRI-visible pathology and MMT-8 scores (p = 0.027) as well as CK levels (p = 0.028). Conclusion: MRI reveals subclinical muscle involvement in early IIM and uncovers subtype-specific patterns. Given the heterogeneity of MRI findings, individualized imaging approaches are warranted. While MRI serves as a valuable adjunct in diagnosis and management of IIM, its utility depends on standardized protocols and integration with clinical and laboratory data to enable accurate interpretation and informed decision-making in clinical practice.

  • Federated Voxel Scene Graph for Intracranial Hemorrhage

    by Antoine P. Sanner, Jonathan Stieber, Nils F. Grauhan, Suam Kim, Marc A. Brockmann, Ahmed E. Othman, Anirban Mukhopadhyay

    Intracranial Hemorrhage is a potentially lethal condition whose manifestation is vastly diverse and shifts across clinical centers worldwide. Deep-learning-based solutions are starting to model complex relations between brain structures, but still struggle to generalize. While gathering more diverse data is the most natural approach, privacy regulations often limit the sharing of medical data. We propose the first application of Federated Scene Graph Generation. We show that our models can leverage the increased training data diversity. For Scene Graph Generation, they can recall up to 20% more clinically relevant relations across datasets compared to models trained on a single centralized dataset. Learning structured data representation in a federated setting can open the way to the development of new methods that can leverage this finer information to regularize across clients more effectively.

  • Open Access

    Deep learning-based detection and classification of intracranial tumors on magnetic resonance imaging

    by Mariya Kondova, Oliver Korczynski, Matthias Müller-Eschner, Winson Chan, Antoine Sanner, Ahmed Othman, Marc A. Brockmann, Sebastian Altmann

    Background: We evaluated the capability of an AI application to independently detect, segment and classify intracranial tumors in MRI.Methods: In this retrospective single-centre study, 138 patients (65 female and 73 male) with a mean age of 35 ± 26y were included. 97 were diagnosed with an intracranial neoplasm, while 41 exhibited no intracranial pathology. Inclusion criteria were a 1.5 or 3.0T MRI dataset with the following sequences: T2 axial, T1 axial pre- and post-contrast with a slice thickness between 3 and 6 mm and no previous brain surgery. Image analysis was performed by two human readers (R1 = 5 years and R2 = 10 years of experience in brain MRI) and a deep learning (DL)-based AI model. Sensitivity, specificity and accuracy of the AI model and the human readers to detect and correctly classify brain tumors were measured. Histological results served as the gold standard.Results: The AI model reached a sensitivity of 93.81% [87.02–97.70] and a specificity of 63.41% [46.94–77.88], while human readers reached 100% [96.27–100.00] and 100% [91.40–100.00], respectively. Human readers provided a significantly higher accuracy rate with R1 0.93 (95% CI: 0.88–0.97) and R2 0.98 (95% CI: 0.94, 0.99) vs. 0.74 (95% CI: 0.66–0.81) for the AI model (P-value <0.001).Conclusion: The underlying DL-based AI algorithm can independently identify and segment intracranial tumors while providing satisfactory results for establishing the correct diagnosis. Despite its current inferiority compared to experienced radiologists, it still experiences ongoing development and it is a step towards developing an artificial intelligence-augmented radiology workflow.


  • Detection of Intracranial Hemorrhage for Trauma Patients

    by Antoine P. Sanner, Nils F. Grauhan, Merle Meyer, Laura Leukert, Marc A. Brockmann, Ahmed E. Othman, Anirban Mukhopadhyay


  • Open Access

    Federated Voxel Scene Graph for Intracranial Hemorrhage

    by Antoine P. Sanner, Jonathan Stieber, Nils F. Grauhan, Suam Kim, Marc A. Brockmann, Ahmed E. Othman, Anirban Mukhopadhyay

    Intracranial Hemorrhage is a potentially lethal condition whose manifestation is vastly diverse and shifts across clinical centers worldwide. Deep-learning-based solutions are starting to model complex relations between brain structures, but still struggle to generalize. While gathering more diverse data is the most natural approach, privacy regulations often limit the sharing of medical data. We propose the first application of Federated Scene Graph Generation. We show that our models can leverage the increased training data diversity. For Scene Graph Generation, they can recall up to 20% more clinically relevant relations across datasets compared to models trained on a single centralized dataset. Learning structured data representation in a federated setting can open the way to the development of new methods that can leverage this finer information to regularize across clients more effectively.

  • Open Access

    Impact of deep Learning-enhanced contrast on diagnostic accuracy in stroke CT angiography

    by Sebastian Steinmetz, Mario Alberto Abello Mercado, Sebastian Altmann, Antoine Sanner, Andrea Kronfeld, Marius Frenzel, Dongok Kim, Sergiu Groppa, Timo Uphaus, Marc A. Brockmann, et al.


  • Voxel Scene Graph for Intracranial Hemorrhage

    by Antoine P. Sanner, Nils F. Grauhan, Marc A. Brockmann, Ahmed E. Othman, Anirban Mukhopadhyay


  • Open Access

    Detection of Intracranial Hemorrhage for Trauma Patients

    by Antoine P. Sanner, Nils F. Grauhan, Marc A. Brockmann, Ahmed E. Othman, Anirban Mukhopadhyay

    Whole-body CT is used for multi-trauma patients in the search of any and all injuries. Since an initial assessment needs to be rapid and the search for lesions is done for the whole body, very little time can be allocated for the inspection of a specific anatomy. In particular, intracranial hemorrhages are still missed, especially by clinical students. In this work, we present a Deep Learning approach for highlighting such lesions to improve the diagnostic accuracy. While most works on intracranial hemorrhages perform segmentation, detection only requires bounding boxes for the localization of the bleeding. In this paper, we propose a novel Voxel-Complete IoU (VC-IoU) loss that encourages the network to learn the 3D aspect ratios of bounding boxes and leads to more precise detections. We extensively experiment on brain bleeding detection using a publicly available dataset, and validate it on a private cohort, where we achieve 0.877 AR30, 0.728 AP30, and 0.653 AR30, 0.514 AP30 respectively. These results constitute a relative +5% improvement in Average Recall for both datasets compared to other loss functions. Finally, as there is little data currently publicly available for 3D object detection and as annotation resources are limited in the clinical setting, we evaluate the cost of different annotation methods, as well as the impact of imprecise bounding boxes in the training data on the detection performance.