Juan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Juan Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Di Zhu
College of Electrical Engineering, Northeast Electric Power University, Jilin, China
1 shared publication - Dongfeng Yang
Northeast Electric Power University
1 shared publication - Hao Wang
Key Laboratory of Modern Power System Simulation and Control and Renewable Energy Technology, Ministry of Education, Northeast Electric Power University, Jilin, China
1 shared publication - Haoran Zhang
State Grid Heilongjiang Electric Power Company Ltd., Harbin Power Supply Company, Harbin, China
1 shared publication - Hui Li
School of Electrical Engineering, Northeast Electric Power University, Jilin, China
1 shared publication - Jingyue Wang
College of Electrical Engineering, Northeast Electric Power University, Jilin, China
1 shared publication
Latest Publications
- Open Access
- 1 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 142883-142898
Research on Distributed Photovoltaic Microgrid System Based on Dual-Output T-Type Three-Level Converter
For adapt to the function of distributed photovoltaic microgrid system of “self-generating and self-using, margin grid-connected”, from the perspective of cost saving and reducing converter volume, the paper proposed a distributed photovoltaic microgrid system (DTPV-MGS) based on the dual output T-type three-level converter (DT-TLC). The DT-TLC structure can output two sets of AC current with controllable frequency and amplitude. The working principle of the circuit is analyzed in this paper. The upper output of the DT-TLC can be directly connected to the AC source / load operating at different amplitudes and frequencies without additional AC/DC/AC converter units. The lower output is connected to the distribution network through the LCL filter to complete the grid connection. The grid-connected control method of the system is designed. Double-loop control method of grid-connected inverter based on voltage-vector directional control (VO-DCC ) is used to control the reference signal of the grid-connected port. For the structure, a time-sharing modulation SVPWM technology is proposed to output the required three-phase AC voltage. In order to reduce the complex workload of SVPWM in the experiment process., a carrier-based pulse width modulation (CBPWM) based on SVPWM is proposed. The switch drive signal is obtained by comparing the modulation wave with the carrier wave. Finally, the feasibility of the proposed DT-TLC-DTPV-MGS, the effectiveness of the modulation method and the control method are experimentally verified.
- 1 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 142883-142898
Open AccessResearch on Distributed Photovoltaic Microgrid System Based on Dual-Output T-Type Three-Level Converter
For adapt to the function of distributed photovoltaic microgrid system of “self-generating and self-using, margin grid-connected”, from the perspective of cost saving and reducing converter volume, the paper proposed a distributed photovoltaic microgrid system (DTPV-MGS) based on the dual output T-type three-level converter (DT-TLC). The DT-TLC structure can output two sets of AC current with controllable frequency and amplitude. The working principle of the circuit is analyzed in this paper. The upper output of the DT-TLC can be directly connected to the AC source / load operating at different amplitudes and frequencies without additional AC/DC/AC converter units. The lower output is connected to the distribution network through the LCL filter to complete the grid connection. The grid-connected control method of the system is designed. Double-loop control method of grid-connected inverter based on voltage-vector directional control (VO-DCC ) is used to control the reference signal of the grid-connected port. For the structure, a time-sharing modulation SVPWM technology is proposed to output the required three-phase AC voltage. In order to reduce the complex workload of SVPWM in the experiment process., a carrier-based pulse width modulation (CBPWM) based on SVPWM is proposed. The switch drive signal is obtained by comparing the modulation wave with the carrier wave. Finally, the feasibility of the proposed DT-TLC-DTPV-MGS, the effectiveness of the modulation method and the control method are experimentally verified.
- Open Access
- 13 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 123603-123615
DC Voltage Utilization Improvement to Enlarge Power Balance Constraint Range for Photovoltaic Cascaded Inverter
In the three-phase photovoltaic (PV) cascaded inverter, the output power of PV arrays is not equal due to the difference of solar radiation, temperature and other factors, which leads to the over modulation of PV cascaded inverter. In order to solve the above problems, the carrier phase-shifted PWM (CPS-PWM) control strategy based on third harmonic injection is proposed in this paper, taking a single-stage high-frequency-link isolated cascaded PV inverter topology with clamping circuits as an example. It can not only improve the utilization of DC voltage, but also enlarge the power balance constraint range between the units in the phase of cascaded PV inverter, so as to ensure that all units can avoid over modulation under some serious power imbalance cases, and will not increase the third harmonic component injection of grid current. Firstly, the topology and working principle of the proposed inverter based on CPS-PWM control strategy are introduced. Then, the improved CPS-PWM control strategy which can improve the DC voltage utilization of the PV cascaded inverter is analyzed, and the control strategy of intra-phase power balance is emphatically analyzed in the overall control strategy of PV cascaded inverter system, and it is discussed that the proposed control strategy can also enlarge the power balance constraint range between the units of the cascaded inverter. Finally, the effectiveness of the proposed PV cascaded inverter based on the improved CPS-PWM control strategy is verified by the simulation and experimental results.
- 13 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 123603-123615
Open AccessDC Voltage Utilization Improvement to Enlarge Power Balance Constraint Range for Photovoltaic Cascaded Inverter
In the three-phase photovoltaic (PV) cascaded inverter, the output power of PV arrays is not equal due to the difference of solar radiation, temperature and other factors, which leads to the over modulation of PV cascaded inverter. In order to solve the above problems, the carrier phase-shifted PWM (CPS-PWM) control strategy based on third harmonic injection is proposed in this paper, taking a single-stage high-frequency-link isolated cascaded PV inverter topology with clamping circuits as an example. It can not only improve the utilization of DC voltage, but also enlarge the power balance constraint range between the units in the phase of cascaded PV inverter, so as to ensure that all units can avoid over modulation under some serious power imbalance cases, and will not increase the third harmonic component injection of grid current. Firstly, the topology and working principle of the proposed inverter based on CPS-PWM control strategy are introduced. Then, the improved CPS-PWM control strategy which can improve the DC voltage utilization of the PV cascaded inverter is analyzed, and the control strategy of intra-phase power balance is emphatically analyzed in the overall control strategy of PV cascaded inverter system, and it is discussed that the proposed control strategy can also enlarge the power balance constraint range between the units of the cascaded inverter. Finally, the effectiveness of the proposed PV cascaded inverter based on the improved CPS-PWM control strategy is verified by the simulation and experimental results.