XYXin Yan

Xin Yan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xin Yan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Generalized Null Subtraction Factor: A Post-Filtering Framework for Contrast Enhancement in Ultrafast Ultrasound Imaging

    by Xiaodong Yang, Xin Yan, Lingling Jing, Yingqi Wang, Xinwei Su

    Poor spatial resolution and contrast remain major challenges in ultrafast ultrasound imaging. Null subtraction imaging (NSI) improves lateral resolution but often degrades speckle quality and contrast. Its extension, dynamic DC-biased NSI (dDC-NSI), mitigates this trade-off by introducing a dynamic DC bias; however, slight speckle suppression may still occur in homogeneous regions, leading to dark-region artifacts. In this work, a generalized null subtraction factor (gNSF) is proposed as a post-processing framework. gNSF applies multiple apodizations, followed by a mirror-flipping and symmetric summation operation, and defines a weighting factor based on the energy ratio between a bias term and a zero-mean sequence. By incorporating the dynamic DC bias, coherent echoes are enhanced while incoherent noise is suppressed. Phantom experiments show that gNSF achieves a contrast performance (gCNR close to 1) comparable to GCF and dDC-NSI, and superior to DAS and NSI. In addition, gNSF improves CR and sSNR by 20% and 21% compared with dDC-NSI, indicating reduced speckle over-suppression and a better balance between contrast and speckle preservation.


  • A Contrast-Enhanced Null Subtraction Imaging Method Using Dynamic DC Bias in Ultrafast Ultrasound Imaging

    by Xin Yan, Xiaodong Yang, Lingling Jing, Wei Guo, Yingqi Wang, Xinwei Su, Yuanyuan Wang

    Enhancing the resolution and contrast of ultrafast ultrasound imaging is imperative for the accuracy of clinical diagnostics. Null subtraction imaging (NSI) is a nonlinear beamforming technique capable of significantly enhancing lateral resolution. However, it suffers from issues of low-quality speckle pattern and poor contrast performance. To address this issue, we propose a novel contrast-enhanced NSI method that utilizes dynamic DC bias. Innovatively, we construct the dynamic DC bias using a generalized coherence factor (GCF) and a sigmoid transformation function that adapts the DC value based on the signal characteristics of different imaging regions. Furthermore, a normalization scheme is proposed to optimize the beamforming output, ensuring uniform pixel intensity throughout the final image. Simulation, phantom, and in vivo data are utilized for ultrasound beamforming to evaluate the performance of the proposed method. Quantitative results show that the proposed method significantly enhances the contrast ratio (CR) by 197%, the contrast-to-noise ratio (CNR) by 341%, the speckle signal-to-noise ratio (sSNR) by 302%, and the generalized contrast-to-noise ratio (gCNR) by 106% compared to the original NSI (in phantom). Point target imaging results indicate that the proposed method achieves a main lobe width slightly wider than the original NSI method, but much narrower than those of DAS and GCF. These findings confirm that the proposed method significantly enhances imaging contrast while preserving high resolution, which is of great significance for the further clinical application of ultrafast ultrasound imaging.


  • Open Access

    Low-Frequency Ultrasound Thoracic Signal Processing Based on Music Algorithm and EMD Wavelet Thresholding

    by Yinggang Zhou, Jifeng Li, Hua Yan, Xin Yan

    Ultrasound is widely used in biomedical imaging. High-frequency ultrasound at MHz is usually used for good resolution. However, ultrasound at this band cannot permeate human thorax, for it is strongly scattered and reflected by air inclusions in the thorax. Low-frequency ultrasound can bypass this limitation and capture useful information deep within the thorax. Hence, this paper presents a new signal processing method to enhance the signal quality of low-frequency ultrasound imaging by improving the signal-to-noise ratio (SNR) and reducing the mean square error (MSE). Specifically, we propose a solution that integrates the empirical mode decomposition (EMD)-based wavelet thresholding algorithm with the multiple signal classification (MUSIC) algorithm. The MUSIC algorithm pre-processes the low-frequency ultrasound signal prior to implementing the EMD-based wavelet threshold denoising algorithm for further noise reduction. We assess the effectiveness of our approach through simulation and experimental research. Results demonstrate substantial performance improvements in the quality of low-frequency ultrasound signals with SNR enhancement ranging from 2.2915 to 3.3358 dB in the simulation, and MSE decrease of 0.3018. Moreover, the experiment yields an SNR improvement range of 1.0274 to 2.9372 dB and a corresponding decrease of 0.2202 in MSE. In agreement with the simulation outcomes, these results confirm the efficacy of our proposed method as an efficient solution for improving the quality of low-frequency ultrasound signals.


  • Regional-Lag Signed Delay Multiply and Sum Beamforming in Ultrafast Ultrasound Imaging

    by Xin Yan, Yanxing Qi, Yinmeng Wang, Yuanyuan Wang

    Ultrafast ultrasound imaging provides very high frame rates but provides poor imaging quality due to unfocused beams. The delay multiply and sum (DMAS) beamformer has been used to improve ultrafast ultrasound imaging contrast but is always accompanied by oversuppression, which produces low-quality speckle images and degrades the contrast performance. A smaller maximum lag in the signed DMAS (sDMAS) contributes better speckle preservation but lower resolution for hyperechoic scatters. To overcome this tradeoff, a regional-lag signed delay multiply and sum (rsDMAS) beamformer is proposed in this article. Innovatively, a region discrimination tool realized by the generalized coherence factor (GCF) is used to limit the maximum lag for spatial coherence estimation. Subaperture coherence smoothing estimates the short-lag coherence instead of multiplication in pairs, thereby reducing calculation complexity and smoothing the speckle texture. Normalization and sign correction are also introduced to achieve better beamforming output. The simulated, phantom, and in vivo data are adopted to evaluate the effectiveness of the proposed beamformer. Numerical results show that the proposed method achieves improvements of the contrast ratio (CR) by 9%, contrast-to-noise ratio (CNR) by 41%, speckle signal-to-noise ratio (sSNR) by 41%, and generalized contrast-to-noise ratio (gCNR) by 0.0004 compared with DMAS (in simulation). Resolution experiments show that the proposed method obtains a loss of 0.07 mm in the full width at half maximum (FWHM) and the same separability of close point scatters as DMAS. These findings indicate that the proposed method achieves higher contrast performance at less obvious sacrifice of the lateral resolution than DMAS.