Mingzhi Yang
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Mingzhi Yang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Bing Gao
State Key Laboratory of High-Efficiency and High-Quality Conversion for Electric Power, Hunan University, Changsha, China
2 shared publications - Husheng Li
School of Energy and Electrical Engineering, Hunan Institute of Science and Technology 1 , Yueyang 414000
2 shared publications - Wenhu Yang
State Key Laboratory of High-Efficiency and High-Quality Conversion for Electric Power, Hunan University, Changsha, Hunan, China
2 shared publications - Xin Yang
College of Electrical and Information Engineering, Hunan University, Changsha, China
2 shared publications - Zewei Wu
College of Electrical and Information Engineering, Hunan University, Changsha, China
2 shared publications - Haobin Zheng
School of Electrical and Information Engineering, Hunan University, Changsha 410082, China
1 shared publication
Latest Publications
- 17 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 17781-17794
Distributed-Parameter Modeling of High-Power Giant Magnetostrictive Transducers Considering Permanent Magnetic Bias
High-power giant magnetostrictive transducers (GMT) with stacked disc permanent magnets (PM) bias are widely used in industrial drive and underwater acoustics. Because they generally use large-size giant magnetostrictive rod (GMR), stacked disc PM bias will cause uneven distribution of the magneto-mechanical field in GMR, and further exacerbate the nonlinearity of the dynamic output of GMT. However, most existing models rarely consider this distributed parameter characteristic in GMT. Therefore, it is necessary to develop a model that can simulate uneven magneto-mechanical coupling characteristics and dynamic behaviors of high-power GMTs. In this paper, a dynamic distributed parameter model (DPM) of high-power GMT with PM bias is developed, which thoroughly considers magnetic uneven spatial distribution, magnetic hysteresis, and mechanical behavior under multiple excitations. This model includes a nonlinear high-precision magnetic equivalent circuit (HP-MEC), an improved J-A model considering bias magnetic field, and a mechanical model. First, model errors of DPM under different numbers of microelements was compared to determine a suitable division in GMR. Secondly, to verify the proposed model, the responses of DPM and lumped parameter model (LPM) with different PM thickness, AC frequencies were compared, and the experimental results verify the superiority of DPM. In addition, in the discussion section, DPM was used to analysis the uneven distribution of magnetic field and the distribution characteristics of dynamic output in GMT. Finally, the application of DPM in the optimal working configuration of high-power GMT is discussed.
- 17 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 17781-17794
Distributed-Parameter Modeling of High-Power Giant Magnetostrictive Transducers Considering Permanent Magnetic Bias
High-power giant magnetostrictive transducers (GMT) with stacked disc permanent magnets (PM) bias are widely used in industrial drive and underwater acoustics. Because they generally use large-size giant magnetostrictive rod (GMR), stacked disc PM bias will cause uneven distribution of the magneto-mechanical field in GMR, and further exacerbate the nonlinearity of the dynamic output of GMT. However, most existing models rarely consider this distributed parameter characteristic in GMT. Therefore, it is necessary to develop a model that can simulate uneven magneto-mechanical coupling characteristics and dynamic behaviors of high-power GMTs. In this paper, a dynamic distributed parameter model (DPM) of high-power GMT with PM bias is developed, which thoroughly considers magnetic uneven spatial distribution, magnetic hysteresis, and mechanical behavior under multiple excitations. This model includes a nonlinear high-precision magnetic equivalent circuit (HP-MEC), an improved J-A model considering bias magnetic field, and a mechanical model. First, model errors of DPM under different numbers of microelements was compared to determine a suitable division in GMR. Secondly, to verify the proposed model, the responses of DPM and lumped parameter model (LPM) with different PM thickness, AC frequencies were compared, and the experimental results verify the superiority of DPM. In addition, in the discussion section, DPM was used to analysis the uneven distribution of magnetic field and the distribution characteristics of dynamic output in GMT. Finally, the application of DPM in the optimal working configuration of high-power GMT is discussed.
- 12 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (7) , 10257-10269
Development of a Comprehensive Dynamic Model for Giant Magnetostrictive Transducers Considering Bias Magnetic Field
Giant magnetostrictive transducers (GMT) featuring high energy density, fast responses, and large output force, are playing an increasingly important role in high-power underwater acoustic detection, acoustic sensors, precision actuation, and other fields. However, the presence of strong magnetic bias, eddy current loss, and hysteresis significantly impact the input and output responses of the transducers, making it difficult to effectively reflect the overall nonlinear characteristics of GMT. Therefore, it is crucial to establish a comprehensive dynamic model that can accurately characterize the dynamic behavior of GMT, including different bias magnetic fields, input frequencies, input amplitudes, and time domain output characteristic. To this end, a comprehensive dynamic nonlinear model, which thoroughly considers the electric, magnetic, mechanical, and their interactions, particularly under the influence of strong bias magnetic field, is developed. Firstly, a magnetic field model is constructed to incorporate both bias magnetic field and AC driving magnetic field. Secondly, an enhanced dynamic magnetization model is proposed to depict the dynamic magnetization process of GMM rod and the internal distribution of the effective magnetic field, based on the theory of energy conservation. Lastly, a multi-degree of freedom (MDOF) dynamic model, considering the distribution characteristics of the GMM rod, is constructed. In order to validate the developed dynamic model, an experimental prototype is produced. The experimental results illustrate that the proposed model is in excellent agreement with the dynamic characteristics of the GMT.
- 12 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (7) , 10257-10269
Development of a Comprehensive Dynamic Model for Giant Magnetostrictive Transducers Considering Bias Magnetic Field
Giant magnetostrictive transducers (GMT) featuring high energy density, fast responses, and large output force, are playing an increasingly important role in high-power underwater acoustic detection, acoustic sensors, precision actuation, and other fields. However, the presence of strong magnetic bias, eddy current loss, and hysteresis significantly impact the input and output responses of the transducers, making it difficult to effectively reflect the overall nonlinear characteristics of GMT. Therefore, it is crucial to establish a comprehensive dynamic model that can accurately characterize the dynamic behavior of GMT, including different bias magnetic fields, input frequencies, input amplitudes, and time domain output characteristic. To this end, a comprehensive dynamic nonlinear model, which thoroughly considers the electric, magnetic, mechanical, and their interactions, particularly under the influence of strong bias magnetic field, is developed. Firstly, a magnetic field model is constructed to incorporate both bias magnetic field and AC driving magnetic field. Secondly, an enhanced dynamic magnetization model is proposed to depict the dynamic magnetization process of GMM rod and the internal distribution of the effective magnetic field, based on the theory of energy conservation. Lastly, a multi-degree of freedom (MDOF) dynamic model, considering the distribution characteristics of the GMM rod, is constructed. In order to validate the developed dynamic model, an experimental prototype is produced. The experimental results illustrate that the proposed model is in excellent agreement with the dynamic characteristics of the GMT.
- 9 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (2) , 812-822
SPICE Modeling of a High-Power Terfenol-D Transducer Considering Losses and Magnetic Flux Leakage
Of great importance is modeling for transducer design and application to predict its performance and simulate key characteristics. The equivalent circuit modeling (ECM), one of the most powerful tools, has been widely used in the transducer industry and academia due to its outstanding merits of low simulation cost and easy usage for multi-field simulation in both time and frequency domains. Nevertheless, most of the existing equivalent circuit models for Terfenol-D transducers normally ignore three material losses, namely elastic loss, piezomagnetic loss, and magnetic loss. Additionally, the magnetic leakage due to the intrinsic poor magnetic permeability of Terfenol-D is rarely considered into the piezomagnetic coupling. Both loss effects will produce substantial errors. Therefore, an improved SPICE model for a high-power Terfenol-D transducer considering the aforementioned three losses and magnetic flux leakage (MFL) is proposed in this article, which is implemented on the platform of LTspice software. To verify the usefulness and effectiveness of the proposed technique, a high-power Terfenol-D tonpilz transducer prototype with a resonance frequency of around 1 kHz and a maximum transmitting current response (TCR) of 187.1 dB/1A/ $\mu $ Pa is built and tested. The experimental results, both in the air and water of the transducer, are in excellent agreement with the simulated results, which well validates our proposed modeling methods.
- 9 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (2) , 812-822
SPICE Modeling of a High-Power Terfenol-D Transducer Considering Losses and Magnetic Flux Leakage
Of great importance is modeling for transducer design and application to predict its performance and simulate key characteristics. The equivalent circuit modeling (ECM), one of the most powerful tools, has been widely used in the transducer industry and academia due to its outstanding merits of low simulation cost and easy usage for multi-field simulation in both time and frequency domains. Nevertheless, most of the existing equivalent circuit models for Terfenol-D transducers normally ignore three material losses, namely elastic loss, piezomagnetic loss, and magnetic loss. Additionally, the magnetic leakage due to the intrinsic poor magnetic permeability of Terfenol-D is rarely considered into the piezomagnetic coupling. Both loss effects will produce substantial errors. Therefore, an improved SPICE model for a high-power Terfenol-D transducer considering the aforementioned three losses and magnetic flux leakage (MFL) is proposed in this article, which is implemented on the platform of LTspice software. To verify the usefulness and effectiveness of the proposed technique, a high-power Terfenol-D tonpilz transducer prototype with a resonance frequency of around 1 kHz and a maximum transmitting current response (TCR) of 187.1 dB/1A/ $\mu $ Pa is built and tested. The experimental results, both in the air and water of the transducer, are in excellent agreement with the simulated results, which well validates our proposed modeling methods.
- Open Access
- 18 November 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (11) , 1416
Characterization of Giant Magnetostrictive Materials Using Three Complex Material Parameters by Particle Swarm Optimization
Complex material parameters that can represent the losses of giant magnetostrictive materials (GMMs) are the key parameters for high-power transducer design and performance analysis. Since the GMMs work under pre-stress conditions and their performance is highly sensitive to pre-stress, the complex parameters of a GMM are preferably characterized in a specific pre-stress condition. In this study, an optimized characterization method for GMMs is proposed using three complex material parameters. Firstly, a lumped parameter model is improved for a longitudinal transducer by incorporating three material losses. Then, the structural damping and contact damping are experimentally measured and applied to confine the parametric variance ranges. Using the improved lumped parameter model, the real parts of the three key material parameters are characterized by fitting the experimental impedance data while the imaginary parts are separately extracted by the phase data. The global sensitivity analysis that accounts for the interaction effects of the multiple parameter variances shows that the proposed method outperforms the classical method as the sensitivities of all the six key parameters to both impedance and phase fitness functions are all high, which implies that the extracted material complex parameters are credible. In addition, the stability and credibility of the proposed parameter characterization is further corroborated by the results of ten random characterizations.
- 18 November 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (11) , 1416
Open AccessCharacterization of Giant Magnetostrictive Materials Using Three Complex Material Parameters by Particle Swarm Optimization
Complex material parameters that can represent the losses of giant magnetostrictive materials (GMMs) are the key parameters for high-power transducer design and performance analysis. Since the GMMs work under pre-stress conditions and their performance is highly sensitive to pre-stress, the complex parameters of a GMM are preferably characterized in a specific pre-stress condition. In this study, an optimized characterization method for GMMs is proposed using three complex material parameters. Firstly, a lumped parameter model is improved for a longitudinal transducer by incorporating three material losses. Then, the structural damping and contact damping are experimentally measured and applied to confine the parametric variance ranges. Using the improved lumped parameter model, the real parts of the three key material parameters are characterized by fitting the experimental impedance data while the imaginary parts are separately extracted by the phase data. The global sensitivity analysis that accounts for the interaction effects of the multiple parameter variances shows that the proposed method outperforms the classical method as the sensitivities of all the six key parameters to both impedance and phase fitness functions are all high, which implies that the extracted material complex parameters are credible. In addition, the stability and credibility of the proposed parameter characterization is further corroborated by the results of ten random characterizations.