Victor Adenis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Victor Adenis has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Elie Partouche
Jean-Marc Edeline Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, Campus CEA Saclay, Route de la Rotonde Bâtiment 151, 91400 Saclay, France
2 shared publications - Jean-Marc Edeline
Paris‐Saclay Institute of Neuroscience (Neuro‐PSI, UMR 9197) CNRS – Université Paris‐Saclay Saclay France
2 shared publications - Pierre Stahl
Oticon Medical, ITSA Medical
2 shared publications A. Jung
Eaton-Peabody Laboratories, Dept. of Otolaryngology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA
1 shared publicationAlejandro Garcia-Chavez
Eaton-Peabody Laboratories, Department of Otolaryngology, Massachusetts Eye and Ear and Harvard Medical School, Boston, USA
1 shared publication- Alix Trouillet
Neuro-X Institute Ecole Polytechnique Fdrale de,Laboratory for Soft Bioelectronic Interfaces,Lausanne,Geneva,Switzerland
1 shared publication
Latest Publications
- Open Access
Revisiting Analog Electrical Stimulation with Current Focusing in a Guinea Pig Model of Cochlear Implants
Modern cochlear implants (CIs) use pulsatile stimulation to restore hearing for individuals with severe hearing loss. CIs provide robust speech recognition in quiet but poorly represent temporal fine structure (TFS), needed for challenging listening situations. Analog stimulation preserves the acoustic waveform and may better encode TFS, yet it has not been evaluated combined with modern current-focusing strategies. We compared neural responses in the inferior colliculus (IC) evoked by CI stimuli consisting of 100 pulses/s biphasic pulse trains and 100 cycles/s sinusoidal analog stimulation with monopolar, bipolar, and tripolar electrode configurations in urethane-anesthetized guinea pigs. Following cochlear implantation, multiunit activity was recorded from the tonotopic axis of the central nucleus of the IC using 16-channel silicon probes. Detection thresholds, spread of excitation, vector strength, sustained response percentage, and temporal response properties were quantified. Analog stimulation consistently evoked significantly lower activation thresholds than pulsatile stimulation while maintaining comparable or sometimes narrower spatial selectivity across stimulation modes. In contrast, analog stimulation generated lower vector strength, larger tonic response components, and a pronounced level-dependent polarity effect. At low stimulus levels, responses were dominated by the cathodic phase of the sinusoidal waveform, whereas increasing stimulus level responses were elicited by both phases, producing synchronization at twice the stimulus frequency. These findings demonstrate that stimulation waveform strongly influences temporal coding while having relatively little effect on the spatial distribution of neural activation. These results provide a physiological basis for reexamining analog stimulation as an alternative strategy for cochlear implant sound coding.
Open AccessRevisiting Analog Electrical Stimulation with Current Focusing in a Guinea Pig Model of Cochlear Implants
Modern cochlear implants (CIs) use pulsatile stimulation to restore hearing for individuals with severe hearing loss. CIs provide robust speech recognition in quiet but poorly represent temporal fine structure (TFS), needed for challenging listening situations. Analog stimulation preserves the acoustic waveform and may better encode TFS, yet it has not been evaluated combined with modern current-focusing strategies. We compared neural responses in the inferior colliculus (IC) evoked by CI stimuli consisting of 100 pulses/s biphasic pulse trains and 100 cycles/s sinusoidal analog stimulation with monopolar, bipolar, and tripolar electrode configurations in urethane-anesthetized guinea pigs. Following cochlear implantation, multiunit activity was recorded from the tonotopic axis of the central nucleus of the IC using 16-channel silicon probes. Detection thresholds, spread of excitation, vector strength, sustained response percentage, and temporal response properties were quantified. Analog stimulation consistently evoked significantly lower activation thresholds than pulsatile stimulation while maintaining comparable or sometimes narrower spatial selectivity across stimulation modes. In contrast, analog stimulation generated lower vector strength, larger tonic response components, and a pronounced level-dependent polarity effect. At low stimulus levels, responses were dominated by the cathodic phase of the sinusoidal waveform, whereas increasing stimulus level responses were elicited by both phases, producing synchronization at twice the stimulus frequency. These findings demonstrate that stimulation waveform strongly influences temporal coding while having relatively little effect on the spatial distribution of neural activation. These results provide a physiological basis for reexamining analog stimulation as an alternative strategy for cochlear implant sound coding.
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Influence des stratégies de stimulation électrique des implants cochléaires sur les réponses neuronales du cortex auditif du cobaye
L’implant cochléaire, la neuroprothèse la plus répandue et la plus réussie de nos jours, permet à des sujets sourds profonds de récupérer une perception auditive permettant une compréhension du langage. Bien que les technologies et les processeurs actuels aient grandement évoluées depuis ces vingt dernières années, la stratégie optimale pour coder l'intensité sonore dans l’implant n’a pas encore été trouvée. L'accès à des indices physiologiques est difficile chez le patient humain alors qu’il est relativement simple chez l’animal. Le but de cette thèse était de développer un modèle animal (cobaye) d'implantation cochléaire et d'étudier la réponse du système auditif à différentes stratégies de stimulation. Les réponses du nerf auditif et des neurones du cortex auditif primaire ont été obtenues lors de stimulations via un implant cochléaire simplifié.Nous avons observé que l’importante variabilité inter-individuelle dans l’efficacité de 2 stratégies (augmentation d’amplitude vs. de durée des pulses électriques) à augmenter les réponses du nerf auditif se répercute au niveau du cortex auditif. Les tests de nouvelles formes de pulses (pulses asymétriques ou en rampes) sur les réponses des neurones corticaux suggèrent que ce type de pulses permettrait de réduire l’étendue corticale activée par la stimulation électrique même aux charges les plus élevées. Là aussi, une importante variabilité inter-individuelle a été observée. Cela a conduit à ce que les activations corticales les plus proches de l’activation normalement observée par des sons purs, soient obtenues soit avec une forme de pulses soit une autre. Cette thèse prône donc qu’il est indispensable d’avoir accès à de nombreuses stratégies de stimulation sur chaque sujet afin de choisir celle la plus adaptée pour un patient donné.
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Influence des stratégies de stimulation électrique des implants cochléaires sur les réponses neuronales du cortex auditif du cobaye
L’implant cochléaire, la neuroprothèse la plus répandue et la plus réussie de nos jours, permet à des sujets sourds profonds de récupérer une perception auditive permettant une compréhension du langage. Bien que les technologies et les processeurs actuels aient grandement évoluées depuis ces vingt dernières années, la stratégie optimale pour coder l'intensité sonore dans l’implant n’a pas encore été trouvée. L'accès à des indices physiologiques est difficile chez le patient humain alors qu’il est relativement simple chez l’animal. Le but de cette thèse était de développer un modèle animal (cobaye) d'implantation cochléaire et d'étudier la réponse du système auditif à différentes stratégies de stimulation. Les réponses du nerf auditif et des neurones du cortex auditif primaire ont été obtenues lors de stimulations via un implant cochléaire simplifié.Nous avons observé que l’importante variabilité inter-individuelle dans l’efficacité de 2 stratégies (augmentation d’amplitude vs. de durée des pulses électriques) à augmenter les réponses du nerf auditif se répercute au niveau du cortex auditif. Les tests de nouvelles formes de pulses (pulses asymétriques ou en rampes) sur les réponses des neurones corticaux suggèrent que ce type de pulses permettrait de réduire l’étendue corticale activée par la stimulation électrique même aux charges les plus élevées. Là aussi, une importante variabilité inter-individuelle a été observée. Cela a conduit à ce que les activations corticales les plus proches de l’activation normalement observée par des sons purs, soient obtenues soit avec une forme de pulses soit une autre. Cette thèse prône donc qu’il est indispensable d’avoir accès à de nombreuses stratégies de stimulation sur chaque sujet afin de choisir celle la plus adaptée pour un patient donné.
- Open Access
- 18 April 2025
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 9 (9) , 1403-1417
High-resolution prosthetic hearing with a soft auditory brainstem implant in macaques
Individuals with compromised cochlear nerves are ineligible for cochlear implants and instead rely on auditory brainstem implants (ABIs). Most users of ABIs experience sound awareness, which aids in lip reading, yet not speech intelligibility. Here we engineered a dual-site (brainstem and cortex) implantable system, scaled to macaque anatomy, for the analysis of auditory perception evoked by electrical stimulation of the cochlear nucleus. A soft multichannel ABI, fabricated using thin-film processing, provided high-resolution auditory percepts, with spatially distinct stimulation sites eliciting cortical responses akin to frequency-specific tuning. Behavioural responses collected over several months were sufficiently precise to distinguish stimulations from adjacent channels. Soft multichannel ABIs may aid the rehabilitation of individuals with profound hearing loss who are ineligible for cochlear implants.
- 18 April 2025
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 9 (9) , 1403-1417
Open AccessHigh-resolution prosthetic hearing with a soft auditory brainstem implant in macaques
Individuals with compromised cochlear nerves are ineligible for cochlear implants and instead rely on auditory brainstem implants (ABIs). Most users of ABIs experience sound awareness, which aids in lip reading, yet not speech intelligibility. Here we engineered a dual-site (brainstem and cortex) implantable system, scaled to macaque anatomy, for the analysis of auditory perception evoked by electrical stimulation of the cochlear nucleus. A soft multichannel ABI, fabricated using thin-film processing, provided high-resolution auditory percepts, with spatially distinct stimulation sites eliciting cortical responses akin to frequency-specific tuning. Behavioural responses collected over several months were sufficiently precise to distinguish stimulations from adjacent channels. Soft multichannel ABIs may aid the rehabilitation of individuals with profound hearing loss who are ineligible for cochlear implants.
- Open Access
- 31 January 2023
- Published by MDPI AG in Brain Sciences
- Vol. 13 (2) , 250
What Is the Benefit of Ramped Pulse Shapes for Activating Auditory Cortex Neurons? An Electrophysiological Study in an Animal Model of Cochlear Implant
In all commercial cochlear implant (CI) devices, the activation of auditory nerve fibers is performed with rectangular pulses that have two phases of opposite polarity. Recently, several papers proposed that ramped pulse shapes could be an alternative shape for efficiently activating auditory nerve fibers. Here, we investigate whether ramped pulse shapes can activate auditory cortex (ACx) neurons in a more efficient way than the classical rectangular pulses. Guinea pigs were implanted with CI devices and responses of ACx neurons were tested with rectangular pulses and with four ramped pulse shapes, with a first-phase being either cathodic or anodic. The thresholds, i.e., the charge level necessary for obtaining significant cortical responses, were almost systematically lower with ramped pulses than with rectangular pulses. The maximal firing rate (FR) elicited by the ramped pulses was higher than with rectangular pulses. As the maximal FR occurred with lower charge levels, the dynamic range (between threshold and the maximal FR) was not modified. These effects were obtained with cathodic and anodic ramped pulses. By reducing the charge levels required to activate ACx neurons, the ramped pulse shapes should reduce charge consumption and should contribute to more battery-efficient CI devices in the future.
- 31 January 2023
- Published by MDPI AG in Brain Sciences
- Vol. 13 (2) , 250
Open AccessWhat Is the Benefit of Ramped Pulse Shapes for Activating Auditory Cortex Neurons? An Electrophysiological Study in an Animal Model of Cochlear Implant
In all commercial cochlear implant (CI) devices, the activation of auditory nerve fibers is performed with rectangular pulses that have two phases of opposite polarity. Recently, several papers proposed that ramped pulse shapes could be an alternative shape for efficiently activating auditory nerve fibers. Here, we investigate whether ramped pulse shapes can activate auditory cortex (ACx) neurons in a more efficient way than the classical rectangular pulses. Guinea pigs were implanted with CI devices and responses of ACx neurons were tested with rectangular pulses and with four ramped pulse shapes, with a first-phase being either cathodic or anodic. The thresholds, i.e., the charge level necessary for obtaining significant cortical responses, were almost systematically lower with ramped pulses than with rectangular pulses. The maximal firing rate (FR) elicited by the ramped pulses was higher than with rectangular pulses. As the maximal FR occurred with lower charge levels, the dynamic range (between threshold and the maximal FR) was not modified. These effects were obtained with cathodic and anodic ramped pulses. By reducing the charge levels required to activate ACx neurons, the ramped pulse shapes should reduce charge consumption and should contribute to more battery-efficient CI devices in the future.
- Open Access
- 31 January 2022
- Published by MDPI AG in Brain Sciences
- Vol. 12 (2) , 205
Increased Threshold and Reduced Firing Rate of Auditory Cortex Neurons after Cochlear Implant Insertion
The cochlear implant (CI) is the most successful neuroprosthesis allowing thousands of patients with profound hearing loss to recover speech understanding. Recently, cochlear implants have been proposed to subjects with residual hearing and, in these cases, shorter CIs were implanted. To be successful, it is crucial to preserve the patient’s remaining hearing abilities after the implantation. Here, we quantified the effects of CI insertion on the responses of auditory cortex neurons in anesthetized guinea pigs. The responses of auditory cortex neurons were determined before and after the insertion of a 300 µm diameter CI (six stimulating electrodes, length 6 mm). Immediately after CI insertion there was a 5 to 15 dB increase in the threshold for cortical neurons from the middle to the high frequencies, accompanied by a decrease in the evoked firing rate. Analyzing the characteristic frequency (CF) values revealed that in large number of cases, the CFs obtained after insertion were lower than before. These effects were not detected in the control animals. These results indicate that there is a small but immediate cortical hearing loss after CI insertion, even with short length CIs. Therefore, efforts should be made to minimize the damages during CI insertion to preserve the cortical responses to acoustic stimuli.
- 31 January 2022
- Published by MDPI AG in Brain Sciences
- Vol. 12 (2) , 205
Open AccessIncreased Threshold and Reduced Firing Rate of Auditory Cortex Neurons after Cochlear Implant Insertion
The cochlear implant (CI) is the most successful neuroprosthesis allowing thousands of patients with profound hearing loss to recover speech understanding. Recently, cochlear implants have been proposed to subjects with residual hearing and, in these cases, shorter CIs were implanted. To be successful, it is crucial to preserve the patient’s remaining hearing abilities after the implantation. Here, we quantified the effects of CI insertion on the responses of auditory cortex neurons in anesthetized guinea pigs. The responses of auditory cortex neurons were determined before and after the insertion of a 300 µm diameter CI (six stimulating electrodes, length 6 mm). Immediately after CI insertion there was a 5 to 15 dB increase in the threshold for cortical neurons from the middle to the high frequencies, accompanied by a decrease in the evoked firing rate. Analyzing the characteristic frequency (CF) values revealed that in large number of cases, the CFs obtained after insertion were lower than before. These effects were not detected in the control animals. These results indicate that there is a small but immediate cortical hearing loss after CI insertion, even with short length CIs. Therefore, efforts should be made to minimize the damages during CI insertion to preserve the cortical responses to acoustic stimuli.