HXHua Xie

Hua Xie

*This is an algorithmically generated author record based on publicly available information.

Hua Xie has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Quantitative Ultrasound Assessment of Hepatic Steatosis

    by Artem Kaliaev, Wilson Chavez, Jorge Soto, Fahimul Huda, Hua Xie, Man Nguyen, Vijay Shamdasani, Stephan Anderson


  • Compartment Syndrome Detection Using Vibration-Enabled Ultrasound Shear Wave Elastography – Simulation and Experimental Results

    by Man M Nguyen, Vijay Shamdasani, Anthony Gades, Kenton W Gregory, Ramon Erkamp, Hua Xie, Meihua Zhu, Todd Graham, Jack Lazar, James M Jones, et al.

    Ultrasound shear wave elastography (SWE) has become a clinically accepted tool for tissue characterization, cancer diagnosis, and therapy assessment. However, it is only commercially available on premium ultrasound scanners and high-performance transducers capable of sustaining high-voltage, long-duration acoustic push-pulses. Mechanical vibration is an alternative method for acoustic radiation force (ARF) to induce shear wave propagation inside soft tissue, thus enabling ultrasound SWE on low-cost and portable systems. One potential application is compartment syndrome (CS), with the acute cases commonly seen in traumatic injuries and chronic cases caused by exercise injuries. CS is a condition in which the increased pressure in the muscle compartment inhibits capillary blood flow and subsequently causes muscle ischemia. To avoid permanent muscle injury, CS must be diagnosed and treated rapidly. In this study, a vibration-enabled SWE prototype was implemented on a commercial scanner and evaluated using an in vivo swine CS model as a proof-of-concept for non-invasive CS detection.


  • Comparison of 2-D speckle tracking and tissue Doppler imaging in an isolated rabbit heart model

    by Congxian Jia, Ragnar Olafsson, Sheng-Wen Huang, Theodore J. Kolias, Kang Kim, Jonathan M. Rubin, Hua Xie, Matthew O'Donnell

    Ultrasound strain imaging has been proposed to quantitatively assess myocardial contractility. Cross-correlation- based 2-D speckle tracking (ST) and auto-correlation-based tissue Doppler imaging (TDI) [often called Doppler tissue imaging (DTI)] are competitive ultrasound techniques for this application. Compared with 2-D ST, TDI, as a 1-D method, is sensitive to beam angle and suffers from low strain signal-to-noise ratio because a high pulse repetition frequency is required to avoid aliasing in velocity estimation. In addition, ST and TDI are fundamentally different in the way that physical parameters such as the mechanical strain are derived, resulting in different estimation accuracy and interpretation. In this study, we directly compared the accuracy of TDI and 2-D ST estimates of instantaneous axial normal strain and accumulated axial normal strain using a simulated heart. We then used an isolated rabbit heart model of acute ischemia produced by left descending anterior artery ligation to evaluate the performance of the two methods in detecting abnormal motion. Results showed that instantaneous axial normal strains derived using TDI (0.36% error) were less accurate with larger variance than those derived from 2-D ST (0.08% error) given the same spatial resolution. In addition to poorer accuracy, accumulated axial normal strain estimates derived using TDI suffered from bias, because the accumulation method for TDI cannot trace along the actual tissue displacement path. Finally, we demonstrated the advantage 2-D ST has over TDI to reduce dependency on beam angle for lesion detection by estimating strains based on the principal stretches and their corresponding principal axes.