Hua Xie
Hua Xie has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Vijay Shamdasani
Philips Healthcare, Bothell, WA, USA
2 shared publicationsAnthony Gades
Philips Healthcare,Bothell,WA,USA
1 shared publication- Artem Kaliaev
Boston Medical Center (M.A., A.K., T.N.N.), Boston, Massachusetts
1 shared publication - Congxian Jia
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
1 shared publication Cynthia R Gregory
Oregon Health & Science University,Portland,OR,USA
1 shared publication- Fahimul Huda
Department of Radiology, University of Louisville, Louisville, USA
1 shared publication
Latest Publications
- 31 January 2022
- Published by Elsevier in Journal of Clinical and Experimental Hepatology
- Vol. 12 (4) , 1091-1101
Quantitative Ultrasound Assessment of Hepatic Steatosis
- 31 January 2022
- Published by Elsevier in Journal of Clinical and Experimental Hepatology
- Vol. 12 (4) , 1091-1101
Quantitative Ultrasound Assessment of Hepatic Steatosis
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1375-1378
Compartment Syndrome Detection Using Vibration-Enabled Ultrasound Shear Wave Elastography – Simulation and Experimental Results
Ultrasound shear wave elastography (SWE) has become a clinically accepted tool for tissue characterization, cancer diagnosis, and therapy assessment. However, it is only commercially available on premium ultrasound scanners and high-performance transducers capable of sustaining high-voltage, long-duration acoustic push-pulses. Mechanical vibration is an alternative method for acoustic radiation force (ARF) to induce shear wave propagation inside soft tissue, thus enabling ultrasound SWE on low-cost and portable systems. One potential application is compartment syndrome (CS), with the acute cases commonly seen in traumatic injuries and chronic cases caused by exercise injuries. CS is a condition in which the increased pressure in the muscle compartment inhibits capillary blood flow and subsequently causes muscle ischemia. To avoid permanent muscle injury, CS must be diagnosed and treated rapidly. In this study, a vibration-enabled SWE prototype was implemented on a commercial scanner and evaluated using an in vivo swine CS model as a proof-of-concept for non-invasive CS detection.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1375-1378
Compartment Syndrome Detection Using Vibration-Enabled Ultrasound Shear Wave Elastography – Simulation and Experimental Results
Ultrasound shear wave elastography (SWE) has become a clinically accepted tool for tissue characterization, cancer diagnosis, and therapy assessment. However, it is only commercially available on premium ultrasound scanners and high-performance transducers capable of sustaining high-voltage, long-duration acoustic push-pulses. Mechanical vibration is an alternative method for acoustic radiation force (ARF) to induce shear wave propagation inside soft tissue, thus enabling ultrasound SWE on low-cost and portable systems. One potential application is compartment syndrome (CS), with the acute cases commonly seen in traumatic injuries and chronic cases caused by exercise injuries. CS is a condition in which the increased pressure in the muscle compartment inhibits capillary blood flow and subsequently causes muscle ischemia. To avoid permanent muscle injury, CS must be diagnosed and treated rapidly. In this study, a vibration-enabled SWE prototype was implemented on a commercial scanner and evaluated using an in vivo swine CS model as a proof-of-concept for non-invasive CS detection.
- 28 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 57 (11) , 2491-2502
Comparison of 2-D speckle tracking and tissue Doppler imaging in an isolated rabbit heart model
Ultrasound strain imaging has been proposed to quantitatively assess myocardial contractility. Cross-correlation- based 2-D speckle tracking (ST) and auto-correlation-based tissue Doppler imaging (TDI) [often called Doppler tissue imaging (DTI)] are competitive ultrasound techniques for this application. Compared with 2-D ST, TDI, as a 1-D method, is sensitive to beam angle and suffers from low strain signal-to-noise ratio because a high pulse repetition frequency is required to avoid aliasing in velocity estimation. In addition, ST and TDI are fundamentally different in the way that physical parameters such as the mechanical strain are derived, resulting in different estimation accuracy and interpretation. In this study, we directly compared the accuracy of TDI and 2-D ST estimates of instantaneous axial normal strain and accumulated axial normal strain using a simulated heart. We then used an isolated rabbit heart model of acute ischemia produced by left descending anterior artery ligation to evaluate the performance of the two methods in detecting abnormal motion. Results showed that instantaneous axial normal strains derived using TDI (0.36% error) were less accurate with larger variance than those derived from 2-D ST (0.08% error) given the same spatial resolution. In addition to poorer accuracy, accumulated axial normal strain estimates derived using TDI suffered from bias, because the accumulation method for TDI cannot trace along the actual tissue displacement path. Finally, we demonstrated the advantage 2-D ST has over TDI to reduce dependency on beam angle for lesion detection by estimating strains based on the principal stretches and their corresponding principal axes.
- 28 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 57 (11) , 2491-2502
Comparison of 2-D speckle tracking and tissue Doppler imaging in an isolated rabbit heart model
Ultrasound strain imaging has been proposed to quantitatively assess myocardial contractility. Cross-correlation- based 2-D speckle tracking (ST) and auto-correlation-based tissue Doppler imaging (TDI) [often called Doppler tissue imaging (DTI)] are competitive ultrasound techniques for this application. Compared with 2-D ST, TDI, as a 1-D method, is sensitive to beam angle and suffers from low strain signal-to-noise ratio because a high pulse repetition frequency is required to avoid aliasing in velocity estimation. In addition, ST and TDI are fundamentally different in the way that physical parameters such as the mechanical strain are derived, resulting in different estimation accuracy and interpretation. In this study, we directly compared the accuracy of TDI and 2-D ST estimates of instantaneous axial normal strain and accumulated axial normal strain using a simulated heart. We then used an isolated rabbit heart model of acute ischemia produced by left descending anterior artery ligation to evaluate the performance of the two methods in detecting abnormal motion. Results showed that instantaneous axial normal strains derived using TDI (0.36% error) were less accurate with larger variance than those derived from 2-D ST (0.08% error) given the same spatial resolution. In addition to poorer accuracy, accumulated axial normal strain estimates derived using TDI suffered from bias, because the accumulation method for TDI cannot trace along the actual tissue displacement path. Finally, we demonstrated the advantage 2-D ST has over TDI to reduce dependency on beam angle for lesion detection by estimating strains based on the principal stretches and their corresponding principal axes.