Patrick Taiwo Ogunboyo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Patrick Taiwo Ogunboyo has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Innocent Ewean Davidson
Department of Electrical, Electronic and Computer Engineering, Cape Peninsula University of Technology, Bellville, Cape Town 7535, South Africa
3 shared publications - Remy Tiako
Discipline of Electrical, Electronic and Computer Engineering, University of KwaZulu-Natal, Durban 4001, KwaZulu-Natal, South Africa
3 shared publications Innocent E. Davidson
Cape Peninsula University of Technology
2 shared publications- Adegoke Oladipo Melodi
Federal University of Technology
1 shared publication - Emmanuel Ayomide Ekson
Olusegun Agagu University of Science and Technology
1 shared publication - Emoemi S. Magi
Olusegun Agagu University of Science and Technology
1 shared publication
Latest Publications
- 18 February 2026
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 932, 91-102
Performance Evaluation of Reverse Power Flow on Electrical Power Network with Wind Energy Source
Renewable energy sources (RES) offer outstanding attributes namely environmental-friendly and reduction in the cost of Grid system. Global power firm have embraced RES in generating electrical energy. RES, notably wind energy lessens electrical power losses on the network, nevertheless, RES incorporation into the network has adverse effect on the entire network. This research bequest critical investigation and comprehensive evaluation of reverse power flow (RPF)due to the outcome of vigorous and increased RES penetration to the Electrical Power Network. Matlab/Simulink Software is employed to carry out critical investigation on eight-bus electrical power network. The Matlab simulation was carried out with and without RES connection to the electric power network. Zones are employed for potent and effective investigation and evaluation of the network. The outcome of evaluation and analysis in sub-networks and the zones were carefully compared. The result show that RPF happens at all levels of electrical power networks, though, the penetration levels are not the same. It was revealed that RPF at the zone directly linked with the RES is higher compared with other zones.
- 18 February 2026
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 932, 91-102
Performance Evaluation of Reverse Power Flow on Electrical Power Network with Wind Energy Source
Renewable energy sources (RES) offer outstanding attributes namely environmental-friendly and reduction in the cost of Grid system. Global power firm have embraced RES in generating electrical energy. RES, notably wind energy lessens electrical power losses on the network, nevertheless, RES incorporation into the network has adverse effect on the entire network. This research bequest critical investigation and comprehensive evaluation of reverse power flow (RPF)due to the outcome of vigorous and increased RES penetration to the Electrical Power Network. Matlab/Simulink Software is employed to carry out critical investigation on eight-bus electrical power network. The Matlab simulation was carried out with and without RES connection to the electric power network. Zones are employed for potent and effective investigation and evaluation of the network. The outcome of evaluation and analysis in sub-networks and the zones were carefully compared. The result show that RPF happens at all levels of electrical power networks, though, the penetration levels are not the same. It was revealed that RPF at the zone directly linked with the RES is higher compared with other zones.
- 18 February 2026
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 932, 139-145
Development of a Predictive Model for Monthly Electricity Consumption Using Population and Weather Data with Web-Based Programming Language
Predicting accurate electricity consumption on electrical distribution network is essential for efficient energy management, particularly in institutional settings where demand fluctuates due to population growth and weather variations. Traditional prediction models often lack real-time accessibility. This study presents a browser-based simulation model for monthly electricity consumption using historical data and dynamic weather inputs, implemented with HTML, CSS, and JavaScript. The model generates forecasts by applying statistically plausible variations (±5%) to historical consumption patterns, integrated with simulated weather data for real-time scenario testing. Compared to complex machine learning approaches, this lightweight solution offers enhanced scalability, remote accessibility, and instant updates without server dependencies which makes it more applicable for smart grid systems and utility management. Results demonstrate its utility as a practical tool for preliminary energy trend analysis, supporting integration with cloud-based data sources. This research will contribute to accessible energy forecasting tools and provides a practical tool for optimizing electricity consumption on electrical distribution network in institutional environments and for institutional planning.
- 18 February 2026
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 932, 139-145
Development of a Predictive Model for Monthly Electricity Consumption Using Population and Weather Data with Web-Based Programming Language
Predicting accurate electricity consumption on electrical distribution network is essential for efficient energy management, particularly in institutional settings where demand fluctuates due to population growth and weather variations. Traditional prediction models often lack real-time accessibility. This study presents a browser-based simulation model for monthly electricity consumption using historical data and dynamic weather inputs, implemented with HTML, CSS, and JavaScript. The model generates forecasts by applying statistically plausible variations (±5%) to historical consumption patterns, integrated with simulated weather data for real-time scenario testing. Compared to complex machine learning approaches, this lightweight solution offers enhanced scalability, remote accessibility, and instant updates without server dependencies which makes it more applicable for smart grid systems and utility management. Results demonstrate its utility as a practical tool for preliminary energy trend analysis, supporting integration with cloud-based data sources. This research will contribute to accessible energy forecasting tools and provides a practical tool for optimizing electricity consumption on electrical distribution network in institutional environments and for institutional planning.
- 23 June 2025
- Published by Trans Tech Publications, Ltd. in Advanced Engineering Forum
- Vol. 56, 85-100
Sub-Saharan Africa Electric Power Distribution Networks Performance Enhancement Prospect
This research sought to assess the enhancement prospects of electric distribution feeders in Sub-Saharan Africa networks for improving electric power supply to end users. Selected feeder’s network was mapped out for element verification and to produce a map of the feeder, which is pertinent for developing single line and impedance diagrams of the network. The map designing was carried out in AutoCAD workspace. The study was aimed at evaluating Sub-Saharan Africa power electric distribution problems and solution proposals for effective application of existing primary electric distribution power supply. Time series load data on the sample distribution feeder were analyzed to evaluate feeder failure rates, mean down times per outage, and availability. The Sub-Saharan Africa electric distribution transformers voltage profiles and loading were computed by employing explicit assessment. Setbacks recorded on the Sub-Saharan Africa networks comprise: unacceptability fragile voltage profile as a result of poor voltage from transmission station. Mitigating these founded problems expect the power generating industry to establish classic, regular and designed sustenance exercises and fast methods to feedback and reduce the rate of failure in the electric system and time of malfunctioning and system interruptions. The computed Sub-Saharan Africa electric distribution network average availability for the year power supplies in the feeder is 0.68, which is far below the world acceptable standard of 0.999. In view of this, the power- producing industry in Sub-Saharan African nations must ensure that voltage coming out from transmission station is of acceptable standard.
- 23 June 2025
- Published by Trans Tech Publications, Ltd. in Advanced Engineering Forum
- Vol. 56, 85-100
Sub-Saharan Africa Electric Power Distribution Networks Performance Enhancement Prospect
This research sought to assess the enhancement prospects of electric distribution feeders in Sub-Saharan Africa networks for improving electric power supply to end users. Selected feeder’s network was mapped out for element verification and to produce a map of the feeder, which is pertinent for developing single line and impedance diagrams of the network. The map designing was carried out in AutoCAD workspace. The study was aimed at evaluating Sub-Saharan Africa power electric distribution problems and solution proposals for effective application of existing primary electric distribution power supply. Time series load data on the sample distribution feeder were analyzed to evaluate feeder failure rates, mean down times per outage, and availability. The Sub-Saharan Africa electric distribution transformers voltage profiles and loading were computed by employing explicit assessment. Setbacks recorded on the Sub-Saharan Africa networks comprise: unacceptability fragile voltage profile as a result of poor voltage from transmission station. Mitigating these founded problems expect the power generating industry to establish classic, regular and designed sustenance exercises and fast methods to feedback and reduce the rate of failure in the electric system and time of malfunctioning and system interruptions. The computed Sub-Saharan Africa electric distribution network average availability for the year power supplies in the feeder is 0.68, which is far below the world acceptable standard of 0.999. In view of this, the power- producing industry in Sub-Saharan African nations must ensure that voltage coming out from transmission station is of acceptable standard.
- 3 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Canadian Journal of Electrical and Computer Engineering
- Vol. 41 (2) , 105-115
Effectiveness of Dynamic Voltage Restorer for Unbalance Voltage Mitigation and Voltage Profile Improvement in Secondary Distribution System
To make a secondary distribution system operate at its optimal performance, the use of an advanced power custom power device known as dynamic voltage restorer (DVR) has been proposed and researched. Optimum performance means acceptable voltage profile, increased reliability of supply, no overloading of cables and distribution transformers, the absence of unbalances in both voltage and current phases, and acceptable loss. This study involves the effective mitigation of power quality disturbance in secondary distribution networks as a result of voltage variation and voltage imbalance using a very effective power electronics-based custom power controller known as DVR. A DVR is connected between the secondary distribution transformer and the customer load along a feeder with a radial arrangement. An innovative new design-model of the DVR has been proposed and developed using dq0 controller and the proportional integral controller method. Model simulations were carried out using MATLAB/Simulink in Sim Power System tool box. The simulation results attest to the optimal performance of the proposed DVR configuration in mitigating the power quality problems, correcting voltage unbalance, and enhancing the voltage profile at the customer side to a statutory limit of ±5.
- 3 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Canadian Journal of Electrical and Computer Engineering
- Vol. 41 (2) , 105-115
Effectiveness of Dynamic Voltage Restorer for Unbalance Voltage Mitigation and Voltage Profile Improvement in Secondary Distribution System
To make a secondary distribution system operate at its optimal performance, the use of an advanced power custom power device known as dynamic voltage restorer (DVR) has been proposed and researched. Optimum performance means acceptable voltage profile, increased reliability of supply, no overloading of cables and distribution transformers, the absence of unbalances in both voltage and current phases, and acceptable loss. This study involves the effective mitigation of power quality disturbance in secondary distribution networks as a result of voltage variation and voltage imbalance using a very effective power electronics-based custom power controller known as DVR. A DVR is connected between the secondary distribution transformer and the customer load along a feeder with a radial arrangement. An innovative new design-model of the DVR has been proposed and developed using dq0 controller and the proportional integral controller method. Model simulations were carried out using MATLAB/Simulink in Sim Power System tool box. The simulation results attest to the optimal performance of the proposed DVR configuration in mitigating the power quality problems, correcting voltage unbalance, and enhancing the voltage profile at the customer side to a statutory limit of ±5.
- 6 August 2018
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 37, 52-61
Electrical Distribution Industry - Long Term Load Forecast on Ilesha Road 11kV Feeder, Akure, Ondo State, Nigeria
This paper presents an investigative study on a selected 11 kV distribution feeder network in Akure township, Nigeria, aimed at evaluating power distribution problems and solution proposals for effective application of existing 11 kV feeders for power supply within Nigeria. Based on peak loads recorded on the feeder for 8 years a long term load forecast up to 2021 was carried out using “Trend’ and “Growth’ functions in Excel worksheet. These functions use Method of Least Squares. The peak network load is 8 MW and the expected load in 2021 is 14.5 MW (18.5 MVA at 0.8 power factor) after an exponential growth rate of 0.6 MW per annum. There is need to increase the rating of the power transformer feeding the feeder in order to enhance the security power supply to the network. Furthermore, the Power Company must provide standard input voltage (1.05x11 kV) to the network in order to normalize end-users voltage quality.
- 6 August 2018
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 37, 52-61
Electrical Distribution Industry - Long Term Load Forecast on Ilesha Road 11kV Feeder, Akure, Ondo State, Nigeria
This paper presents an investigative study on a selected 11 kV distribution feeder network in Akure township, Nigeria, aimed at evaluating power distribution problems and solution proposals for effective application of existing 11 kV feeders for power supply within Nigeria. Based on peak loads recorded on the feeder for 8 years a long term load forecast up to 2021 was carried out using “Trend’ and “Growth’ functions in Excel worksheet. These functions use Method of Least Squares. The peak network load is 8 MW and the expected load in 2021 is 14.5 MW (18.5 MVA at 0.8 power factor) after an exponential growth rate of 0.6 MW per annum. There is need to increase the rating of the power transformer feeding the feeder in order to enhance the security power supply to the network. Furthermore, the Power Company must provide standard input voltage (1.05x11 kV) to the network in order to normalize end-users voltage quality.
- 30 March 2018
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 35, 60-76
Investigation of Voltage Unbalance Profile in Low Voltage Electrical Distribution Network with Normal Mode Operation Using MATLAB
With ever increasing use of semiconductor devices and information technology (ICT) equipment in the industry, homes and offices, power quality is gaining attention to both industry and the electric utility. Power voltage quality cause huge economic losses to businesses all over the world. It is estimated to cost industry and commerce about €100 billion per annum in European Union, since voltage quality problem is one of the major power quality disturbances. This paper presents an investigative a study of the 11/0.4 kV, low voltage electrical distribution network and analyzes voltage unbalance. It recommends an effective method of improving the voltage profile and reducing the voltage unbalance to acceptable standard. The network was modelled using distribution network standard parameters for low voltage distribution network using MATLAB/Simulink sim power system tool box. The simulation results show that the percentage voltage unbalance, correct voltage profile and minimum voltage drop of 0.5 km distribution feeder line is of standard acceptable statutory limit, hence the distribution line operates at optimum performance. However, it is also established that the voltage profile for distribution network feeder lengths of 0.8 km to 5 km for balanced and unbalanced distribution lines from the beginning to the customer terminal of the distribution lengths are less than the acceptable allowable limit of – 5 %, of the nominal voltage value, hence voltages are inadmissible for customers use. Moreso, the percentage voltage unbalance, voltage profile and voltage drop on 0.8 km to 5 km distribution feeder line are all less than standard acceptable statutory limit, hence the distribution line operates below optimum performance. It was established that mitigating these problems require the electricity distribution company to install an effective voltage boosting devices along the network lengths in order provide admissible, permissible and normalize end users standard acceptable voltage.
- 30 March 2018
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 35, 60-76
Investigation of Voltage Unbalance Profile in Low Voltage Electrical Distribution Network with Normal Mode Operation Using MATLAB
With ever increasing use of semiconductor devices and information technology (ICT) equipment in the industry, homes and offices, power quality is gaining attention to both industry and the electric utility. Power voltage quality cause huge economic losses to businesses all over the world. It is estimated to cost industry and commerce about €100 billion per annum in European Union, since voltage quality problem is one of the major power quality disturbances. This paper presents an investigative a study of the 11/0.4 kV, low voltage electrical distribution network and analyzes voltage unbalance. It recommends an effective method of improving the voltage profile and reducing the voltage unbalance to acceptable standard. The network was modelled using distribution network standard parameters for low voltage distribution network using MATLAB/Simulink sim power system tool box. The simulation results show that the percentage voltage unbalance, correct voltage profile and minimum voltage drop of 0.5 km distribution feeder line is of standard acceptable statutory limit, hence the distribution line operates at optimum performance. However, it is also established that the voltage profile for distribution network feeder lengths of 0.8 km to 5 km for balanced and unbalanced distribution lines from the beginning to the customer terminal of the distribution lengths are less than the acceptable allowable limit of – 5 %, of the nominal voltage value, hence voltages are inadmissible for customers use. Moreso, the percentage voltage unbalance, voltage profile and voltage drop on 0.8 km to 5 km distribution feeder line are all less than standard acceptable statutory limit, hence the distribution line operates below optimum performance. It was established that mitigating these problems require the electricity distribution company to install an effective voltage boosting devices along the network lengths in order provide admissible, permissible and normalize end users standard acceptable voltage.
- 19 January 2018
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 34, 81-101
Voltage Unbalance Mitigation and Voltage Profile Enhancement in Secondary Distribution System Using Dynamic Voltage Restorer
This study addresses the effective mitigation of power quality disturbance such as unbalanced voltage, voltage fluctuation, voltage variation of secondary distribution network using dynamic voltage restorer (DVR). To make distribution system operate at its best performance and minimum loss, DVR is employed. The proposed system is designed using MATLAB/Simulink in Sim Power System tool box. Considering, nevertheless, that standard acceptable performance implies correct voltage profile, minimum loss, no phase shift for voltage and current, absence of overloading of transformers and electrical wires, and acceptable frequency deviation. The new setup of DVR has been put forward using dq0 controller and proportional integral (PI) controller method to improve voltage profile, correct unbalance voltage and enhance power quality problems in secondary distribution network. The simulation results attest to the ability of the proposed DVR configuration in mitigating the power quality problems in secondary distribution network.
- 19 January 2018
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 34, 81-101
Voltage Unbalance Mitigation and Voltage Profile Enhancement in Secondary Distribution System Using Dynamic Voltage Restorer
This study addresses the effective mitigation of power quality disturbance such as unbalanced voltage, voltage fluctuation, voltage variation of secondary distribution network using dynamic voltage restorer (DVR). To make distribution system operate at its best performance and minimum loss, DVR is employed. The proposed system is designed using MATLAB/Simulink in Sim Power System tool box. Considering, nevertheless, that standard acceptable performance implies correct voltage profile, minimum loss, no phase shift for voltage and current, absence of overloading of transformers and electrical wires, and acceptable frequency deviation. The new setup of DVR has been put forward using dq0 controller and proportional integral (PI) controller method to improve voltage profile, correct unbalance voltage and enhance power quality problems in secondary distribution network. The simulation results attest to the ability of the proposed DVR configuration in mitigating the power quality problems in secondary distribution network.
- 12 January 2017
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 28, 142-156
Application of Dynamic Voltage Restorer for Power Quality Improvement in Low Voltage Electrical Power Distribution Network: An Overview
Dynamic Voltage Restorer (DVR) is a series connected power electronics based custom power device that is used to improve voltage disturbances in low voltage electrical power distribution network. Power quality requirement is one of the most important concerns for power system. The parts of the DVR is made up of voltage source inverter, injection/booster transformer, a harmonic filter, an energy storage device and a bypass switch. The DVR is used to inject three phase voltage in series and in synchronism with the network voltages in order to compensate voltage disturbances with a benefit of active /reactive power control. This paper presents a review of the researches on the dynamic voltage restorer application for power quality improvement in low voltage electrical power distribution networks. It describes power quality issues, principle of operation of DVR, basic components of DVR, DVRs control topologies in distribution network, DVR control strategies and compensation techniques.
- 12 January 2017
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 28, 142-156
Application of Dynamic Voltage Restorer for Power Quality Improvement in Low Voltage Electrical Power Distribution Network: An Overview
Dynamic Voltage Restorer (DVR) is a series connected power electronics based custom power device that is used to improve voltage disturbances in low voltage electrical power distribution network. Power quality requirement is one of the most important concerns for power system. The parts of the DVR is made up of voltage source inverter, injection/booster transformer, a harmonic filter, an energy storage device and a bypass switch. The DVR is used to inject three phase voltage in series and in synchronism with the network voltages in order to compensate voltage disturbances with a benefit of active /reactive power control. This paper presents a review of the researches on the dynamic voltage restorer application for power quality improvement in low voltage electrical power distribution networks. It describes power quality issues, principle of operation of DVR, basic components of DVR, DVRs control topologies in distribution network, DVR control strategies and compensation techniques.