Po-Yi Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Po-Yi Lee has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Ian A. Sigal
University of Pittsburgh
3 shared publications Andrew Theophanous
Department of Bioengineering, University of Pittsburgh , Pittsburgh, PA 15261
1 shared publicationBin Yang
Department of Ophthalmology, School of Medicine, University of Pittsburgh, Pittsburgh, PA
1 shared publication- Bin Yang
Duquesne University
1 shared publication - Brett E. Bouma
Massachusetts General Hospital
1 shared publication - Chuan-Bor Chueh
Massachusetts General Hospital
1 shared publication
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (10) , 4985-4996
Polarization-Sensitive Module for Optical Coherence Tomography Instruments
Birefringence, retardance, Jones matrix, optic axis orientation, polarization-sensitive optical coherence tomography, retina.Polarization-sensitive optical coherence tomography (PS-OCT) extends OCT by analyzing the polarization states of backscattered light to quantify tissue birefringence. However, conventional implementations require polarization-diverse detection and are therefore incompatible with most commercial OCT systems. As a result, PS-OCT has largely remained restricted to specialized research groups, limiting its broader scientific and clinical use. Here, we present a modular PS-OCT framework that integrates with a standard spectral-domain OCT platform through a detachable rotating achromatic half-wave plate in the sample arm. This waveplate modulates both incident and reflected polarization states. Three or more repeated measurements at distinct waveplate orientations enable reconstruction of the sample's round-trip Jones matrix and the corresponding polarization properties. To mitigate random phase variations between repeated measurements, we introduce a phase optimization strategy. We validate the framework with imaging of birefringent phantoms and the human retina in vivo, demonstrating reliable reconstruction of retardance and optic axis orientation. In this study, we implemented a polarization-sensitive module on the SPECTRALIS platform with minimal hardware modification. The framework could potentially be extended to other OCT systems with appropriate mechanical integration and access to acquisition data. By reducing the hardware complexity typically associated with conventional PS-OCT, this framework may facilitate broader adoption of PS-OCT imaging in both research and clinical settings.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (10) , 4985-4996
Polarization-Sensitive Module for Optical Coherence Tomography Instruments
Birefringence, retardance, Jones matrix, optic axis orientation, polarization-sensitive optical coherence tomography, retina.Polarization-sensitive optical coherence tomography (PS-OCT) extends OCT by analyzing the polarization states of backscattered light to quantify tissue birefringence. However, conventional implementations require polarization-diverse detection and are therefore incompatible with most commercial OCT systems. As a result, PS-OCT has largely remained restricted to specialized research groups, limiting its broader scientific and clinical use. Here, we present a modular PS-OCT framework that integrates with a standard spectral-domain OCT platform through a detachable rotating achromatic half-wave plate in the sample arm. This waveplate modulates both incident and reflected polarization states. Three or more repeated measurements at distinct waveplate orientations enable reconstruction of the sample's round-trip Jones matrix and the corresponding polarization properties. To mitigate random phase variations between repeated measurements, we introduce a phase optimization strategy. We validate the framework with imaging of birefringent phantoms and the human retina in vivo, demonstrating reliable reconstruction of retardance and optic axis orientation. In this study, we implemented a polarization-sensitive module on the SPECTRALIS platform with minimal hardware modification. The framework could potentially be extended to other OCT systems with appropriate mechanical integration and access to acquisition data. By reducing the hardware complexity typically associated with conventional PS-OCT, this framework may facilitate broader adoption of PS-OCT imaging in both research and clinical settings.
- Open Access
- 1 January 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (01) , 1-32
Collagen microarchitecture from polarized light imaging: a biomechanics perspective
SignificanceCollagen, the main load-bearing component in tissue, is present in all animals and forms a variety of networks from the fibrils, fibers, bundles, and lamellae into which it self-assembles. The collagen microstructure is different among tissue types, and the different microstructures give rise to tissue-specific mechanical properties. Therefore, methods for visualizing collagen fibers and their orientation are essential for understanding the biomechanical properties of tissue.AimOur aim in this review is to provide the basis for understanding the methodology of polarized light imaging methods and how they can be used to characterize collagen microstructure.ApproachWe begin with a description of collagen microstructure and its relationship to tissue biomechanics, a basic formalism of polarized light, and how collagen interacts with polarized light. We then describe polarized light microscopy and its various forms, particularly instant polarized light microscopy, then polarization-sensitive optical coherence tomography, and last, polarization-resolved second-harmonic generation microscopy.ResultsWe describe methods for imaging collagen microstructure with polarized light from in vivo methods to high-resolution volumetric imaging of tissue sections.ConclusionsWe intend to help those interested in using polarized light to image and understand the relationship between collagen microstructure and biomechanics.
- 1 January 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (01) , 1-32
Open AccessCollagen microarchitecture from polarized light imaging: a biomechanics perspective
SignificanceCollagen, the main load-bearing component in tissue, is present in all animals and forms a variety of networks from the fibrils, fibers, bundles, and lamellae into which it self-assembles. The collagen microstructure is different among tissue types, and the different microstructures give rise to tissue-specific mechanical properties. Therefore, methods for visualizing collagen fibers and their orientation are essential for understanding the biomechanical properties of tissue.AimOur aim in this review is to provide the basis for understanding the methodology of polarized light imaging methods and how they can be used to characterize collagen microstructure.ApproachWe begin with a description of collagen microstructure and its relationship to tissue biomechanics, a basic formalism of polarized light, and how collagen interacts with polarized light. We then describe polarized light microscopy and its various forms, particularly instant polarized light microscopy, then polarization-sensitive optical coherence tomography, and last, polarization-resolved second-harmonic generation microscopy.ResultsWe describe methods for imaging collagen microstructure with polarized light from in vivo methods to high-resolution volumetric imaging of tissue sections.ConclusionsWe intend to help those interested in using polarized light to image and understand the relationship between collagen microstructure and biomechanics.
- 11 June 2025
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 147 (8) , 1-34
Lamina Cribrosa Hypoxia Sensitivity to Variations of Anatomy and Vascular Factors
Insufficient oxygenation in the lamina cribrosa (LC) may contribute to axonal damage and glaucomatous vision loss. To understand the range of susceptibilities to glaucoma, we aimed to identify key factors influencing LC oxygenation and examine if these factors vary with anatomical differences between eyes. We reconstructed three-dimensional, eye-specific LC vessel networks from histological sections of four healthy monkey eyes. For each network, we generated 125 models varying vessel radius, oxygen consumption rate, and arteriole perfusion pressure. Using hemodynamic and oxygen supply modeling, we predicted blood flow distribution and tissue oxygenation in the LC. ANOVA assessed the significance of each parameter. Our results showed that vessel radius had the greatest influence on LC oxygenation, followed by anatomical variations. Arteriole perfusion pressure and oxygen consumption rate were the third and fourth most influential factors, respectively. The LC regions are well perfused under baseline conditions. These findings highlight the importance of vessel radius and anatomical variation in LC oxygenation, providing insights into LC physiology and pathology. Pathologies affecting vessel radius may increase the risk of LC hypoxia, and anatomical variations could influence susceptibility. Conversely, increased oxygen consumption rates had minimal effects, suggesting that higher metabolic demands, such as those needed to maintain intracellular transport despite elevated intra-ocular pressure (IOP), have limited impact on LC oxygenation.
- 11 June 2025
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 147 (8) , 1-34
Lamina Cribrosa Hypoxia Sensitivity to Variations of Anatomy and Vascular Factors
Insufficient oxygenation in the lamina cribrosa (LC) may contribute to axonal damage and glaucomatous vision loss. To understand the range of susceptibilities to glaucoma, we aimed to identify key factors influencing LC oxygenation and examine if these factors vary with anatomical differences between eyes. We reconstructed three-dimensional, eye-specific LC vessel networks from histological sections of four healthy monkey eyes. For each network, we generated 125 models varying vessel radius, oxygen consumption rate, and arteriole perfusion pressure. Using hemodynamic and oxygen supply modeling, we predicted blood flow distribution and tissue oxygenation in the LC. ANOVA assessed the significance of each parameter. Our results showed that vessel radius had the greatest influence on LC oxygenation, followed by anatomical variations. Arteriole perfusion pressure and oxygen consumption rate were the third and fourth most influential factors, respectively. The LC regions are well perfused under baseline conditions. These findings highlight the importance of vessel radius and anatomical variation in LC oxygenation, providing insights into LC physiology and pathology. Pathologies affecting vessel radius may increase the risk of LC hypoxia, and anatomical variations could influence susceptibility. Conversely, increased oxygen consumption rates had minimal effects, suggesting that higher metabolic demands, such as those needed to maintain intracellular transport despite elevated intra-ocular pressure (IOP), have limited impact on LC oxygenation.
- 31 January 2022
- Published by Elsevier in Experimental Eye Research
- Vol. 217, 108967
Real-time imaging of optic nerve head collagen microstructure and biomechanics using instant polarized light microscopy
- 31 January 2022
- Published by Elsevier in Experimental Eye Research
- Vol. 217, 108967
Real-time imaging of optic nerve head collagen microstructure and biomechanics using instant polarized light microscopy