Xin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xin Zhang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Qihe Shan
Navigation College, Dalian Maritime University, Dalian 116026, China
2 shared publications - Chun Lung Philip Chen
South China University of Technology
1 shared publication - Fei Teng
Marine Electrical Engineering College, Dalian Maritime University, Dalian, China
1 shared publication - Qiongyue Zhang
Navigation College
1 shared publication - Qiuye Sun
Northeastern University
1 shared publication - Tieshan Li
University of Electronic Science and Technology of China
1 shared publication
Latest Publications
- 3 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Cybernetics
- Vol. 55 (2) , 917-926
Distributed Resilient Energy Management for Seaport Microgrid Against Stealthy Attacks With Limited Security Defense Resource
This article investigates the distributed resilient energy management (EM) strategy for the seaport microgrid under stealthy attacks. First, based on an analysis of seaport microgrid characteristics, we construct an EM model that aims at minimizing both operating cost and security defense resource (SDR) cost. Second, we present a distributed, resilient strategy by defining node security levels and establishing dynamic security intervals. We prove that the gap between the obtained feasible solution and the optimal one is bounded. The designed strategy is capable of tolerating the effect of the unlimited number of stealthy attacked nodes on the seaport microgrid. In addition, given the limited SDRs for the resilient EM of the island seaport microgrid, a distributed mechanism for searching the minimum security connected dominating set (MSCDS) is proposed to minimize the size of trusted nodes. Finally, simulation results demonstrate the effectiveness of the proposed strategy. Note to Practitioners: This article addresses the vulnerability of the seaport microgrid, a critical issue that impacts EM and disrupts seaport operations. Current approaches to seaport EM do not account for potential attacks. Meanwhile, existing methods for attack resilience often overlook the costs of security resources. We propose a new approach for the distributed and resilient EM of the island seaport microgrid. Secure operation is achieved by protecting the fewest trusted nodes, thereby conserving SDRs. We then show how this algorithm (searching the MSCDS) can be efficiently designed. Preliminary simulations indicate its feasibility, though it has yet to be tested in a production environment. Future research will focus on designing trusted nodes within dynamic topologies.
- 3 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Cybernetics
- Vol. 55 (2) , 917-926
Distributed Resilient Energy Management for Seaport Microgrid Against Stealthy Attacks With Limited Security Defense Resource
This article investigates the distributed resilient energy management (EM) strategy for the seaport microgrid under stealthy attacks. First, based on an analysis of seaport microgrid characteristics, we construct an EM model that aims at minimizing both operating cost and security defense resource (SDR) cost. Second, we present a distributed, resilient strategy by defining node security levels and establishing dynamic security intervals. We prove that the gap between the obtained feasible solution and the optimal one is bounded. The designed strategy is capable of tolerating the effect of the unlimited number of stealthy attacked nodes on the seaport microgrid. In addition, given the limited SDRs for the resilient EM of the island seaport microgrid, a distributed mechanism for searching the minimum security connected dominating set (MSCDS) is proposed to minimize the size of trusted nodes. Finally, simulation results demonstrate the effectiveness of the proposed strategy. Note to Practitioners: This article addresses the vulnerability of the seaport microgrid, a critical issue that impacts EM and disrupts seaport operations. Current approaches to seaport EM do not account for potential attacks. Meanwhile, existing methods for attack resilience often overlook the costs of security resources. We propose a new approach for the distributed and resilient EM of the island seaport microgrid. Secure operation is achieved by protecting the fewest trusted nodes, thereby conserving SDRs. We then show how this algorithm (searching the MSCDS) can be efficiently designed. Preliminary simulations indicate its feasibility, though it has yet to be tested in a production environment. Future research will focus on designing trusted nodes within dynamic topologies.
- Open Access
- 31 January 2022
- Published by Wiley in Complexity
- Vol. 2022 (1)
Distributed Energy Management for Port Power System under False Data Injection Attacks
This paper investigates a distributed energy management strategy for the port power system under false data injection attacks. The attacker can tamper with the interaction information of energy equipment, penetrate the boundary between port information system and port power system, and cause serious operation failure of port energy equipment. Firstly, a hierarchical topology is proposed to allocate the security resources of the port power system. Secondly, by reconstructing the topological structure of the port information system, the robustness of the information system is improved, and the impact of false data injection attacks on the port power system is reduced, which realizes secure distributed energy management of the port power system. Finally, the simulation results show the effectiveness of the proposed strategy, and the defense capability of the port power system is improved.
- 31 January 2022
- Published by Wiley in Complexity
- Vol. 2022 (1)
Open AccessDistributed Energy Management for Port Power System under False Data Injection Attacks
This paper investigates a distributed energy management strategy for the port power system under false data injection attacks. The attacker can tamper with the interaction information of energy equipment, penetrate the boundary between port information system and port power system, and cause serious operation failure of port energy equipment. Firstly, a hierarchical topology is proposed to allocate the security resources of the port power system. Secondly, by reconstructing the topological structure of the port information system, the robustness of the information system is improved, and the impact of false data injection attacks on the port power system is reduced, which realizes secure distributed energy management of the port power system. Finally, the simulation results show the effectiveness of the proposed strategy, and the defense capability of the port power system is improved.