Anna Katharina Wigger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anna Katharina Wigger has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Peter Haring Bolívar
Institute of High Frequency and Quantum Electronics, University of Siegen, Siegen, Germany
8 shared publications - Anja-Katrin Bosserhoff
Institute of Biochemistry, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany
4 shared publications - Christian Weisenstein
University of Siegen, Institute for High Frequencies and Quantum Electronics , Siegen , Germany
4 shared publications - Merle Richter
High Frequency and Quantum Electronics, University of Siegen, Siegen, Germany
3 shared publications Gunnar Spickermann
Institute of High Frequency and Quantum Electronics, University of Siegen 1 , Hoelderlinstr. 3, D-57076 Siegen, Germany
2 shared publications- Robert Sczech
Institute of High Frequency and Quantum Electronics, University of Siegen, Siegen, Germany
2 shared publications
Latest Publications
- Open Access
- 1 July 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (7) , 483
Multifrequency Investigation of Single- and Double-Stranded DNA with Scalable Metamaterial-Based THz Biosensors
Due to the occurrence of THz-excited vibrational modes in biomacromolecules, the THz frequency range has been identified as particularly suitable for developing and applying new bioanalytical methods. We present a scalable THz metamaterial-based biosensor being utilized for the multifrequency investigation of single- and double-stranded DNA (ssDNA and dsDNA) samples. It is demonstrated that the metamaterial resonance frequency shift by the DNA’s presence depends on frequency. Our experiments with the scalable THz biosensors demonstrate a major change in the degree of the power function for dsDNA by 1.53 ± 0.06 and, in comparison, 0.34 ± 0.11 for ssDNA as a function of metamaterial resonance frequency. Thus, there is a significant advantage for dsDNA detection that can be used for increased sensitivity of biomolecular detection at higher frequencies. This work represents a first step for application-specific biosensors with potential advantages in sensitivity, specificity, and robustness.
- 1 July 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (7) , 483
Open AccessMultifrequency Investigation of Single- and Double-Stranded DNA with Scalable Metamaterial-Based THz Biosensors
Due to the occurrence of THz-excited vibrational modes in biomacromolecules, the THz frequency range has been identified as particularly suitable for developing and applying new bioanalytical methods. We present a scalable THz metamaterial-based biosensor being utilized for the multifrequency investigation of single- and double-stranded DNA (ssDNA and dsDNA) samples. It is demonstrated that the metamaterial resonance frequency shift by the DNA’s presence depends on frequency. Our experiments with the scalable THz biosensors demonstrate a major change in the degree of the power function for dsDNA by 1.53 ± 0.06 and, in comparison, 0.34 ± 0.11 for ssDNA as a function of metamaterial resonance frequency. Thus, there is a significant advantage for dsDNA detection that can be used for increased sensitivity of biomolecular detection at higher frequencies. This work represents a first step for application-specific biosensors with potential advantages in sensitivity, specificity, and robustness.
- Open Access
- 31 January 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (5) , 053702
Substrate-integrated microfluidics for sensitive biosensing with complementary THz metamaterials in water
Metamaterials can be utilized for a variety of applications and have emerged as a valuable tool in THz technologies. Used as THz biosensors, metasurfaces can significantly improve the sensitivity in the detection of biomolecules, but the high THz absorption of water represents a major challenge for the realization of a sensor for measurements in liquids. In this article, we propose an approach where the resonance feature of complementary asymmetric split ring resonators (CASRR) is maintained even for measurements in water, allowing highly sensitive detection of biomolecules in strongly absorbing liquids. This is enabled by the introduction of substrate-integrated microfluidics, which are shown to have a minimal effect on the transmission properties of the metamaterial. Due to this approach, the metamaterial structure design is independent from the microfluidic channels. Our simulations also show that the sensitivity of CASRR changes only marginally for lossless and highly absorbing materials. At the same time, the presented concept is easy to fabricate by standard lithography methods and can be applied to other metamaterial structures as well.
- 31 January 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (5) , 053702
Open AccessSubstrate-integrated microfluidics for sensitive biosensing with complementary THz metamaterials in water
Metamaterials can be utilized for a variety of applications and have emerged as a valuable tool in THz technologies. Used as THz biosensors, metasurfaces can significantly improve the sensitivity in the detection of biomolecules, but the high THz absorption of water represents a major challenge for the realization of a sensor for measurements in liquids. In this article, we propose an approach where the resonance feature of complementary asymmetric split ring resonators (CASRR) is maintained even for measurements in water, allowing highly sensitive detection of biomolecules in strongly absorbing liquids. This is enabled by the introduction of substrate-integrated microfluidics, which are shown to have a minimal effect on the transmission properties of the metamaterial. Due to this approach, the metamaterial structure design is independent from the microfluidic channels. Our simulations also show that the sensitivity of CASRR changes only marginally for lossless and highly absorbing materials. At the same time, the presented concept is easy to fabricate by standard lithography methods and can be applied to other metamaterial structures as well.
- Open Access
- 31 May 2021
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 42 (6) , 607-646
THz Detection of Biomolecules in Aqueous Environments—Status and Perspectives for Analysis Under Physiological Conditions and Clinical use
Bioanalytical THz sensing techniques have proven to be an interesting and viable tool for the label-free detection and analysis of biomolecules. However, a major challenge for THz bioanalytics is to perform investigations in the native aqueous environments of the analytes. This review recapitulates the status and future requirements for establishing THz biosensing as a complementary toolbox in the repertoire of standard bioanalytic methods. The potential use in medical research and clinical diagnosis is discussed. Under these considerations, this article presents a comprehensive categorization of biochemically relevant analytes that have been investigated by THz sensing techniques in aqueous media. The detectable concentration levels of ions, carbohydrates, (poly-)nucleotides, active agents, proteins and different biomacromolecules from THz experiments are compared to characteristic physiological concentrations and lower detection limits of state-of-the-art bioanalytical methods. Finally, recent experimental developments and achievements are discussed, which potentially pave the way for THz analysis of biomolecules under clinically relevant conditions.
- 31 May 2021
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 42 (6) , 607-646
Open AccessTHz Detection of Biomolecules in Aqueous Environments—Status and Perspectives for Analysis Under Physiological Conditions and Clinical use
Bioanalytical THz sensing techniques have proven to be an interesting and viable tool for the label-free detection and analysis of biomolecules. However, a major challenge for THz bioanalytics is to perform investigations in the native aqueous environments of the analytes. This review recapitulates the status and future requirements for establishing THz biosensing as a complementary toolbox in the repertoire of standard bioanalytic methods. The potential use in medical research and clinical diagnosis is discussed. Under these considerations, this article presents a comprehensive categorization of biochemically relevant analytes that have been investigated by THz sensing techniques in aqueous media. The detectable concentration levels of ions, carbohydrates, (poly-)nucleotides, active agents, proteins and different biomacromolecules from THz experiments are compared to characteristic physiological concentrations and lower detection limits of state-of-the-art bioanalytical methods. Finally, recent experimental developments and achievements are discussed, which potentially pave the way for THz analysis of biomolecules under clinically relevant conditions.
- Open Access
THz detection of biomolecules in aqueous environments -- status and perspectives for analysis under physiological conditions and clinical use
Bioanalytical THz sensing techniques have proven to be an interesting and viable tool for the label-free detection and analysis of biomolecules. However, a major challenge for THz bioanalytics is to perform investigations in the native aqueous environments of the analytes. This review recapitulates the status and future requirements for establishing THz biosensing as a complementary toolbox in the repertoire of standard bioanalytic methods. The potential use in medical research and clinical diagnosis is discussed. Under these considerations, this article presents a comprehensive categorization of biochemically relevant analytes that have been investigated by THz sensing techniques in aqueous media. The detectable concentration levels of ions, carbohydrates, (poly-)nucleotides, active agents, proteins and different biomacromolecules from THz experiments are compared to characteristic physiological concentrations and lower detection limits of state-of-the-art bioanalytical methods. Finally, recent experimental developments and achievements are discussed, which potentially pave the way for THz analysis of biomolecules under clinically relevant conditions.
Open AccessTHz detection of biomolecules in aqueous environments -- status and perspectives for analysis under physiological conditions and clinical use
Bioanalytical THz sensing techniques have proven to be an interesting and viable tool for the label-free detection and analysis of biomolecules. However, a major challenge for THz bioanalytics is to perform investigations in the native aqueous environments of the analytes. This review recapitulates the status and future requirements for establishing THz biosensing as a complementary toolbox in the repertoire of standard bioanalytic methods. The potential use in medical research and clinical diagnosis is discussed. Under these considerations, this article presents a comprehensive categorization of biochemically relevant analytes that have been investigated by THz sensing techniques in aqueous media. The detectable concentration levels of ions, carbohydrates, (poly-)nucleotides, active agents, proteins and different biomacromolecules from THz experiments are compared to characteristic physiological concentrations and lower detection limits of state-of-the-art bioanalytical methods. Finally, recent experimental developments and achievements are discussed, which potentially pave the way for THz analysis of biomolecules under clinically relevant conditions.
- 11 February 2021
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 38 (3) , 815-824
Reducing errors in THz material parameter determination by model-based time-domain extraction methods
We demonstrate a reduction of THz material parameter estimation errors by a factor of 40, using a time-domain material-model-based extraction method, in comparison with the respective frequency-domain approach. Based on simulated and experimentally measured THz time-domain spectroscopy data with different levels of the signal-to-noise ratios (SNR), an improved robustness of the time-domain scheme with regard to noise is demonstrated. This approach thereby provides an additional tool for the extraction of material parameters, which is especially suited for the evaluation of spectral data of samples with strong resonant absorption features, even if the SNR at those features drops below 0 dB. The cause for the difference in performance between the frequency-domain and time-domain methods is identified and a formal description provided.
- 11 February 2021
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 38 (3) , 815-824
Reducing errors in THz material parameter determination by model-based time-domain extraction methods
We demonstrate a reduction of THz material parameter estimation errors by a factor of 40, using a time-domain material-model-based extraction method, in comparison with the respective frequency-domain approach. Based on simulated and experimentally measured THz time-domain spectroscopy data with different levels of the signal-to-noise ratios (SNR), an improved robustness of the time-domain scheme with regard to noise is demonstrated. This approach thereby provides an additional tool for the extraction of material parameters, which is especially suited for the evaluation of spectral data of samples with strong resonant absorption features, even if the SNR at those features drops below 0 dB. The cause for the difference in performance between the frequency-domain and time-domain methods is identified and a formal description provided.
- 20 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 3 (5) , 649-655
Broadband Terahertz Analysis of Energetic Materials—Influence of Crystal Structure and Additives
A detailed broadband analysis of energetic materials using THz time-domain spectroscopy with a bandwidth from 0.2 to 6.4 THz is presented. Dependencies of the resonance features on different sample parameters are evaluated via spectroscopic investigation of several energetic materials (TNT, C4, RDX, PETN, AN) in transmission and reflection experiments. A strong dependency of the resonance features on the manufacturing process of an explosive is observed especially with TNT. The THz measurements of the TNT samples are compared to powder X-ray diffraction measurements. Furthermore, it is observed that additive compounds with a flat frequency response offset the THz reflection of an explosive, but the recognition capability of a resonance feature is not influenced.
- 20 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 3 (5) , 649-655
Broadband Terahertz Analysis of Energetic Materials—Influence of Crystal Structure and Additives
A detailed broadband analysis of energetic materials using THz time-domain spectroscopy with a bandwidth from 0.2 to 6.4 THz is presented. Dependencies of the resonance features on different sample parameters are evaluated via spectroscopic investigation of several energetic materials (TNT, C4, RDX, PETN, AN) in transmission and reflection experiments. A strong dependency of the resonance features on the manufacturing process of an explosive is observed especially with TNT. The THz measurements of the TNT samples are compared to powder X-ray diffraction measurements. Furthermore, it is observed that additive compounds with a flat frequency response offset the THz reflection of an explosive, but the recognition capability of a resonance feature is not influenced.
- 25 March 2013
- Published by AIP Publishing in Applied Physics Letters
- Vol. 102 (12) , 121102
Uncooled antenna-coupled terahertz detectors with 22 μs response time based on BiSb/Sb thermocouples
We report on fast terahertz detectors based on antenna-coupled BiSb/Sb thermoelements operating at room temperature. A response time of the thermocouples as low as 22 μs and a noise equivalent power of at 1 kHz modulation frequency is measured in air at room temperature. The integration capability of these mass producible devices enables large-scale detector arrays for real-time terahertz imaging applications. Due to the fast response time, multiplexing of the detectors can be used to reduce the required readout circuits.- 25 March 2013
- Published by AIP Publishing in Applied Physics Letters
- Vol. 102 (12) , 121102
Uncooled antenna-coupled terahertz detectors with 22 μs response time based on BiSb/Sb thermocouples
We report on fast terahertz detectors based on antenna-coupled BiSb/Sb thermoelements operating at room temperature. A response time of the thermocouples as low as 22 μs and a noise equivalent power of at 1 kHz modulation frequency is measured in air at room temperature. The integration capability of these mass producible devices enables large-scale detector arrays for real-time terahertz imaging applications. Due to the fast response time, multiplexing of the detectors can be used to reduce the required readout circuits.- 30 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 1 (1) , 183-200
THz Active Imaging Systems With Real-Time Capabilities
This paper presents a survey of the status of five active THz imaging modalities which we have developed and investigated during the last few years with the goal to explore their potential for real-time imaging. We start out by introducing a novel waveguide-based all-electronic imaging system which operates at 812 GHz. Its salient feature is a 32-pixel linear detector array heterodyne-operated at the eighth subharmonic. This array in combination with a telescope optics for object distances of 2-6 m reaches a data acquisition speed suited for real-time imaging. The second system described then is again an all-electronic scanner (now for around 300 GHz ), designed for object distances of ≥ 8 m , which combines mechanical scanning in vertical direction, synthetic-aperture image generation in horizontal direction, and frequency-modulated continuous-wave sweeping for the depth information. The third and fourth systems follow an optoelectronic approach by relying on several- to multi-pixel parallel electrooptic detection. One imager is based on a pulsed THz-OPO and homodyne detection with a CCD camera, the other on either continuous-wave electronic or femtosecond optoelectronic THz sources and a photonic-mixing device (PMD) camera. The article concludes with a description of the state of the art of imaging with focal-plane arrays based on CMOS field-effect transistors.
- 30 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 1 (1) , 183-200
THz Active Imaging Systems With Real-Time Capabilities
This paper presents a survey of the status of five active THz imaging modalities which we have developed and investigated during the last few years with the goal to explore their potential for real-time imaging. We start out by introducing a novel waveguide-based all-electronic imaging system which operates at 812 GHz. Its salient feature is a 32-pixel linear detector array heterodyne-operated at the eighth subharmonic. This array in combination with a telescope optics for object distances of 2-6 m reaches a data acquisition speed suited for real-time imaging. The second system described then is again an all-electronic scanner (now for around 300 GHz ), designed for object distances of ≥ 8 m , which combines mechanical scanning in vertical direction, synthetic-aperture image generation in horizontal direction, and frequency-modulated continuous-wave sweeping for the depth information. The third and fourth systems follow an optoelectronic approach by relying on several- to multi-pixel parallel electrooptic detection. One imager is based on a pulsed THz-OPO and homodyne detection with a CCD camera, the other on either continuous-wave electronic or femtosecond optoelectronic THz sources and a photonic-mixing device (PMD) camera. The article concludes with a description of the state of the art of imaging with focal-plane arrays based on CMOS field-effect transistors.