Anthony N. Aggouras
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anthony N. Aggouras has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Brianne K. Connizzo
Boston University
2 shared publications A. Samuel Flemister
University of Rochester, Department of Orthopaedic Surgery, Rochester, New York, NY, USA
1 shared publication- Emma J. Stowe
Department of Biomedical Engineering, Boston University, Boston, MA 02215, United States
1 shared publication - John Ketz
Department of Orthopaedics & Physical Performance, University of Rochester Medical Center, Rochester, NY, USA
1 shared publication Laura C. Slane
Department of Mechanical Engineering, University of Rochester, Rochester, New York, NY, USA
1 shared publicationMark R. Buckley
Department of Biomedical Engineering, University of Rochester, Rochester, New York, NY, USA
1 shared publication
Latest Publications
- Open Access
Aged Tendons Exhibit Altered Mechanisms of Strain-Dependent Extracellular Matrix Remodeling
Aging is a primary risk factor for degenerative tendon injuries, yet the etiology and progression of this degeneration is poorly understood. While aged tendons have innate cellular differences that support a reduced ability to maintain mechanical tissue homeostasis, the response of aged tendons to altered levels of mechanical loading has not yet been studied. To address this question, we subjected young and aged murine flexor tendon explants to various levels of in vitro tensile strain. We first compared the effect of static and cyclic strain on matrix remodeling in young tendons, finding that cyclic strain is optimal for studying remodeling in vitro . We then investigated the remodeling response of young and aged tendon explants after 7 days of varied mechanical stimulus (stress-deprivation, 1%, 3%, 5%, or 7% cyclic strain) via assessment of tissue composition, biosynthetic capacity, and degradation profiles. We hypothesized that aged tendons would show muted adaptive responses to changes in tensile strain and exhibit a shifted mechanical setpoint, at which the remodeling balance is optimal. Interestingly, we found 1% cyclic strain best maintains native physiology while promoting ECM turnover for both age groups. However, aged tendons display fewer strain-dependent changes, suggesting a reduced ability to adapt to altered levels of mechanical loading. This work has significant impact in understanding the regulation of tissue homeostasis in aged tendons, which can inform clinical rehabilitation strategies for treating elderly patients.
Open AccessAged Tendons Exhibit Altered Mechanisms of Strain-Dependent Extracellular Matrix Remodeling
Aging is a primary risk factor for degenerative tendon injuries, yet the etiology and progression of this degeneration is poorly understood. While aged tendons have innate cellular differences that support a reduced ability to maintain mechanical tissue homeostasis, the response of aged tendons to altered levels of mechanical loading has not yet been studied. To address this question, we subjected young and aged murine flexor tendon explants to various levels of in vitro tensile strain. We first compared the effect of static and cyclic strain on matrix remodeling in young tendons, finding that cyclic strain is optimal for studying remodeling in vitro . We then investigated the remodeling response of young and aged tendon explants after 7 days of varied mechanical stimulus (stress-deprivation, 1%, 3%, 5%, or 7% cyclic strain) via assessment of tissue composition, biosynthetic capacity, and degradation profiles. We hypothesized that aged tendons would show muted adaptive responses to changes in tensile strain and exhibit a shifted mechanical setpoint, at which the remodeling balance is optimal. Interestingly, we found 1% cyclic strain best maintains native physiology while promoting ECM turnover for both age groups. However, aged tendons display fewer strain-dependent changes, suggesting a reduced ability to adapt to altered levels of mechanical loading. This work has significant impact in understanding the regulation of tissue homeostasis in aged tendons, which can inform clinical rehabilitation strategies for treating elderly patients.
- 15 March 2023
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 41 (10) , 2261-2272
Earlier proteoglycan turnover promotes higher efficiency matrix remodeling in MRL/MpJ tendons
While most mammalian tissue regeneration is limited, the Murphy Roths Large (MRL/MpJ) mouse has been identified to regenerate several tissues, including tendon. Recent studies have indicated that this regenerative response is innate to the tendon tissue and not reliant on a systemic inflammatory response. Therefore, we hypothesized that MRL/MpJ mice may also exhibit a more robust homeostatic regulation of tendon structure in response to mechanical loading. To assess this, MRL/MpJ and C57BL/6J flexor digitorum longus tendon explants were subjected to stress‐deprived conditions in vitro for up to 14 days. Explant tendon health (metabolism, biosynthesis, and composition), matrix metalloproteinase (MMP) activity, gene expression, and tendon biomechanics were assessed periodically. We found a more robust response to the loss of mechanical stimulus in the MRL/MpJ tendon explants, exhibiting an increase in collagen production and MMP activity consistent with previous in vivo studies. This greater collagen turnover was preceded by an early expression of small leucine‐rich proteoglycans and proteoglycan‐degrading MMP‐3, promoting efficient regulation and organization of newly synthesized collagen and allowing for more efficient overall turnover in MRL/MpJ tendons. Therefore, mechanisms of MRL/MpJ matrix homeostasis may be fundamentally different from that of B6 tendons and may indicate better recovery from mechanical microdamage in MRL/MpJ tendons. We demonstrate here the utility of the MRL/MpJ model in elucidating mechanisms of efficient matrix turnover and its potential to shed light on new targets for more effective treatments for degenerative matrix changes brought about by injury, disease, or aging.
- 15 March 2023
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 41 (10) , 2261-2272
Earlier proteoglycan turnover promotes higher efficiency matrix remodeling in MRL/MpJ tendons
While most mammalian tissue regeneration is limited, the Murphy Roths Large (MRL/MpJ) mouse has been identified to regenerate several tissues, including tendon. Recent studies have indicated that this regenerative response is innate to the tendon tissue and not reliant on a systemic inflammatory response. Therefore, we hypothesized that MRL/MpJ mice may also exhibit a more robust homeostatic regulation of tendon structure in response to mechanical loading. To assess this, MRL/MpJ and C57BL/6J flexor digitorum longus tendon explants were subjected to stress‐deprived conditions in vitro for up to 14 days. Explant tendon health (metabolism, biosynthesis, and composition), matrix metalloproteinase (MMP) activity, gene expression, and tendon biomechanics were assessed periodically. We found a more robust response to the loss of mechanical stimulus in the MRL/MpJ tendon explants, exhibiting an increase in collagen production and MMP activity consistent with previous in vivo studies. This greater collagen turnover was preceded by an early expression of small leucine‐rich proteoglycans and proteoglycan‐degrading MMP‐3, promoting efficient regulation and organization of newly synthesized collagen and allowing for more efficient overall turnover in MRL/MpJ tendons. Therefore, mechanisms of MRL/MpJ matrix homeostasis may be fundamentally different from that of B6 tendons and may indicate better recovery from mechanical microdamage in MRL/MpJ tendons. We demonstrate here the utility of the MRL/MpJ model in elucidating mechanisms of efficient matrix turnover and its potential to shed light on new targets for more effective treatments for degenerative matrix changes brought about by injury, disease, or aging.
- 27 January 2022
- Published by SAGE Publications in Foot & Ankle International
- Vol. 43 (5) , 683-693
Impingement in Insertional Achilles Tendinopathy Occurs Across a Larger Range of Ankle Angles and Is Associated With Increased Tendon Thickness
Background: Insertional Achilles tendinopathy (IAT) is characterized by tendon degeneration and thickening near the tendon-bone insertion. 11 Calcaneal impingement is believed to contribute to the pathogenesis of IAT. 5 However, it is unclear how increased tendon thickness in individuals with IAT influences impingement. This study aimed to compare Achilles tendon impingement in individuals with and without IAT. Methods: Eight healthy adults and 12 adults with clinically diagnosed symptomatic IAT performed a passive flexion exercise during which ankle flexion angle, anterior-posterior (A-P) thickness, and an ultrasonographic image sequence of the Achilles tendon insertion were acquired. The angle of ankle plantarflexion at which the calcaneus first impinges the Achilles tendon, defined as the impingement onset angle, was identified by (1) a anonymized observer (visual inspection method) and (2) a computational image deformation-based approach (curvature method). Results: Although the 2 methods provided different impingement onset angles, the measurements were strongly correlated ( R 2 = 0.751, P < .05). The impingement onset angle and the thickness of the Achilles tendon insertion were greater in subjects with clinically diagnosed IAT ( P = .0048, P = .0047). Furthermore, impingement onset angle proved to have a moderate correlation with anterior-posterior thickness ( R 2 = 0.454, P < .05). Conclusion: Our findings demonstrated that increased tendon thickness in IAT patients is associated with larger impingement onset angles, raising the range of ankle angles over which the tendon is exposed to impingement. Clinical Relevance: Increased susceptibility to impingement may exacerbate or perpetuate the pathology, highlighting the need for clinical strategies to reduce impingement in IAT patients.
- 27 January 2022
- Published by SAGE Publications in Foot & Ankle International
- Vol. 43 (5) , 683-693
Impingement in Insertional Achilles Tendinopathy Occurs Across a Larger Range of Ankle Angles and Is Associated With Increased Tendon Thickness
Background: Insertional Achilles tendinopathy (IAT) is characterized by tendon degeneration and thickening near the tendon-bone insertion. 11 Calcaneal impingement is believed to contribute to the pathogenesis of IAT. 5 However, it is unclear how increased tendon thickness in individuals with IAT influences impingement. This study aimed to compare Achilles tendon impingement in individuals with and without IAT. Methods: Eight healthy adults and 12 adults with clinically diagnosed symptomatic IAT performed a passive flexion exercise during which ankle flexion angle, anterior-posterior (A-P) thickness, and an ultrasonographic image sequence of the Achilles tendon insertion were acquired. The angle of ankle plantarflexion at which the calcaneus first impinges the Achilles tendon, defined as the impingement onset angle, was identified by (1) a anonymized observer (visual inspection method) and (2) a computational image deformation-based approach (curvature method). Results: Although the 2 methods provided different impingement onset angles, the measurements were strongly correlated ( R 2 = 0.751, P < .05). The impingement onset angle and the thickness of the Achilles tendon insertion were greater in subjects with clinically diagnosed IAT ( P = .0048, P = .0047). Furthermore, impingement onset angle proved to have a moderate correlation with anterior-posterior thickness ( R 2 = 0.454, P < .05). Conclusion: Our findings demonstrated that increased tendon thickness in IAT patients is associated with larger impingement onset angles, raising the range of ankle angles over which the tendon is exposed to impingement. Clinical Relevance: Increased susceptibility to impingement may exacerbate or perpetuate the pathology, highlighting the need for clinical strategies to reduce impingement in IAT patients.