JLJian Li

Jian Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jian Li has a total of 230 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Author Correction: Plasmonic printing of high-performance metal oxide electronics under room temperature.

    by Zhan Gao, Yang Fu, Qiang Zhang, Jian Li, Zhiyuan Li, Guihuan Guo, Dengfeng Li, Jingkun Zhou, Dangyuan Lei, Xinge Yu

  • Open Access

    Drawn-on-skin electronic tattoo as a closed-loop sensing-stimulation system for the muscles

    by Ya Huang, Zhenlin Chen, Jingkun Zhou, Huiling Jia, Lung Chow, Yu Zhou, Shengxin Jia, Binbin Zhang, Faheem Ershad, Shubham Patel, et al.

    Simultaneous electromyography (EMG) sensing and closed-loop electrical stimulation (ES) could enable interactive muscle training, motor rehabilitation, and kinesthetic feedback. However, current systems often suffer from nonconformal device/skin interfaces, poor wearability, and anatomical variability among users, limiting signal fidelity and stimulation precision. Here, we present a fully wireless, skin-integrated electronic tattoo platform that records high-quality EMG and delivers closed-loop ES through custom drawn-on-skin, conformal electrodes with strong adhesion and high spatial accuracy. The system supports closed-loop muscle interactions across body regions and even between individuals. Machine learning models classify EMG patterns from different hand gestures with >90% accuracy and adapt ES parameters to stimulate specific muscle groups. In a heavy object holding task, users reached the required grip behavior substantially faster than unassisted controls, indicating improved neuromuscular efficiency. This closed-loop framework not only supports personalized muscle control but also supports coordinated activation across multiple sites or users, unlocking possibilities in interactive motor training, remote rehabilitation, and virtual reality environments.


  • A three-dimensional stretchable core–shell cable for soft and hybrid electronics that is patternable, recyclable and noise-resistant

    by Pengcheng Wu, Shengxin Jia, Jiyu Li, Lung Chow, Tianqi Xia, Guoqiang Xu, Chun Ki Yiu, Binbin Zhang, Zhan Gao, Xingcan Huang, et al.


  • Open Access

    Wearable Tailored Passive Radiative Cooling Textile for Flexible Electronic Integration

    by Lung Chow, Jianpeng Zhang, Zehua Peng, Denglin Ye, Binbin Zhang, Jian Li, Wooyoung Park, Chentao Du, Xingcan Huang, Chun Ki Yiu, et al.

    Textiles are ideal platforms for wearable electronics due to their inherent softness and superior thermophysiological comfort. However, conventional textiles prioritize wearer comfort at the cost of the stringent thermal‐optical demands imposed by embedded electronics, often sacrificing scalability, breathability, electronic integrability, device performance, and user safety. Here, we report a wearable tailored passive radiative cooling textile (WRCT) for seamless integration of flexible electronics. The WRCT was fabricated via a scalable, one‐step, and additive‐free wet‐spinning technique. Hierarchical phase inversion kinetics create microfibers with multiscale porosity and surface nodules, achieving solar reflectance (>95%) and mid‐infrared emissivity (0.96). This single‐material platform satisfies the conflicting requirements of wearing comfort and electronic functionality by providing breathability, flexibility, and passive daytime thermal management. These properties thermally decouple electronics from the skin and keep skin temperature below 41°C even under intense sunlight (500 W/m 2 ) combined with a localized heat load equivalent to a heat flux of approximately 17 kW/m 2 over a 142 mm 2 area, simulating high‐power microcontrollers, conditions that cause low‐temperature burns within minutes on conventional textiles. By converting a commodity polymer into an advanced thermal‐optical regulator through a mature and scalable fiber‐production process, this textile establishes a practical, safe, and manufacturable foundation for reliable, all‐day wearable electronic systems.


  • A Perspective on Non-Invasive Blood Pressure Monitoring: Bridging Emerging Principles, Enabling Technologies and Extended Applications

    by Chentao Du, Ting Xiang, Guangyao Zhao, Mengkang Deng, Zijun Liu, Zexu Yang, Jiayuan Fang, Ningxu Yuan, Siyuan Zhou, Jian Li, et al.

    Cardiovascular disease (CVD), the leading global cause of death, highlights the critical need for effective blood pressure management. Non-invasive blood pressure (NIBP) monitoring, compared with invasive methods, enables home-based and long-term use, supporting early detection and continuous care. Despite significant progress, challenges remain, including accuracy issues, insufficient validation in real-world settings, limited application-specific sensor designs, and inadequate calibration standards and validation platforms. These gaps call for a systematic review to clarify the unmet needs and future research directions. This article reviews current advances in four key areas: (1) novel NIBP estimation principles designed to minimize user intervention; (2) flexible and wearable electronics that improve accuracy and comfort; (3) integration with theranostic applications and broader healthcare scenarios enabled by NIBP technologies; (4) calibration and validation strategies that enhance reliability and accuracy. With the rapid growth of home healthcare and AI-enabled wearable systems, addressing these challenges is essential to advance personalized, precise and stable cardiovascular medicine.


  • Open Access

    Assessment of Acute Stress and Chronic Stress for Mental Health Management by a Fully Integrated Wearable Biosystem

    by Hongwei Chu, Wooyoung Park, Yue Hu, Zhenhe Huang, Rui Shi, Jiyu Li, Zhiyuan Li, Mengge Wu, Yuyu Gao, Guangyao Zhao, et al.

    Mental stress has been a paramount concern worldwide, serving as a critical element for the optimal functioning and thriving of families, communities, and societies. However, the evaluation of the mental stress state in current clinical practice relies on symptom criteria associated with self-reported psychometric tools and behavioral manifestations, which raises the concerns of both accuracy issue and difficulty in identifying classifications. Continuous and quantitative assessments of mental stress-related physical/biomarkers based on wearable technologies is a very feasible way to solve the hurdle, while the implementation of such technology at clinical scales remains quite challenging and has yet to be documented. Herein, we report the collection of advances in sensing strategies, system integration, and model construction for mental health monitoring and management. A set of physical/biomarkers (cortisol, glucose, body temperature, and heart rate) are selected based on the systematic studies on the stress-correlated physiological pathways to form the marker panel. Corresponding stable and sustainable sensing systems are established upon the optimization of nanomaterials and nanostructure design. Comprehensive indicators are further generated based on algorithm bonuses for acute and chronic stress assessment. The fully integrated reusable wearable biosystem demonstrates its effectiveness in identifying, quantifying, and tracking the prognosis of stress in paradigmatic stress scenarios and clinical applications of social anxiety disorder/depression. The technology reported here presents a promising solution for customized mental stress management to facilitate the development of healthcare in psychological well-being.


  • Top Cited Papers
    Open Access

    Tactile-Transparent Wearable Sensor for Clinician-Friendly Pulse Wave Velocity Monitoring and Cardiovascular Risk Profiling

    by Senlin Hou, Xiaotong Chen, Dani S. Assi, Yu Feng, Chun-Ka Wong, Jingting Tian, Jian Li, Xiaodong Yu, Binghe Guan, Xiaohu Zhu, et al.

    Arterial stiffening is an independent risk factor for cardiovascular diseases, particularly affecting organs with low vascular resistance, such as the brain and kidneys. Pulse wave velocity (PWV) is the clinical gold standard for arterial stiffness assessment; however, conventional equipment requires complex setups and trained operators, limiting real-world and point-of-care monitoring. Here, we introduce a tactile-transparent wearable (TTW) sensor that preserves physicians' tactile pulse palpation abilities while providing quantitative cardiovascular risk assessment by integrating flexible Polydimethylsiloxane (PDMS) electrodes and ultrathin graphene oxide dielectric films. In a clinical study with 20 healthy volunteers (aged 22-60 years), the TTW sensor showed strong agreement with Doppler ultrasound for carotid-radial PWV (Pearson's r = 0.88, p < 0.001; mean difference = - 0.084 m/s) and identified that arterial stiffness is significantly correlated with age and BMI (both p < 0.001). High-fidelity waveform analysis further provided dynamic vascular risk indices (augmentation index, reflection index, stiffness index) not accessible by Doppler. This TTW sensor democratizes arterial stiffness assessment, providing transformative potential for preventive cardiology and enabling widespread adoption, especially in resource-limited or community healthcare settings.


  • Top Cited Papers
    Open Access

    A skin-interfaced three-dimensional closed-loop sensing and therapeutic electronic wound bandage

    by Xingcan Huang, Qiang Zhang, Yawen Yang, Lung Chow, Jie Ma, Guoqiang Xu, Fang Guo, Xinxin He, Zhiyuan Li, Guangyao Zhao, et al.

    Chronic wound healing is a complex and long-standing problem, that has been a major and critical clinical concern around the world for years. Recent advances in digital wound dressings open new possibilities for solving the problem. Here, we report a battery-free, fully permeable, skin-adhesive, stretchable electronic wound bandage (iSAFE) for intelligent wound management. This electronic bandage exhibits superior properties in multiple features and can be conformally adhered to the skin wound. In addition, the iSAFE can accurately assess the wound conditions in-situ and thus adaptively perform localized drug release. The results from both in vitro and in vivo studies on animals prove the validity of wound monitoring, wound healing boosting and intelligent closed-loop wound management. Clinical trials on patients across age 18 to 95 with various types of wounds are performed. These results all indicate the unique and universality of the reported technology for wound monitoring and management.


  • Plasmonic printing of high-performance metal oxide electronics under room temperature

    by Zhan Gao, Yang Fu, Qiang Zhang, Jian Li, Zhiyuan Li, Guihuan Guo, Dengfeng Li, Jingkun Zhou, Dangyuan Lei, Xinge Yu

    Solution-processed metal oxide (MO) thin-film transistors present substantial promise for next-generation large-area, low-cost electronics. However, challenges like prolonged high-temperature annealing (at >400 °C) and a lack of universal, high-resolution printing technology hinder their widespread applications. Here we report a processing technology, termed ‘plasmonic printing’, for fabricating high-performance, solution-processed all-MO thin-film electronics under room temperature and ambient conditions. This process leverages femtosecond-laser-excited silver nanowires to induce plasmonic local heating, facilitating rapid (<0.3 s) and localized conversion of MO precursors into high-quality MO thin films, including conductor, dielectric and semiconductor. Remarkably, these MO thin films exhibit superior electrical performance without the requirement of special gases or high-temperature treatment, thereby enhancing the fabrication efficiency. Furthermore, precise pattern control is demonstrated, enabling the fabrication of high-density, solution-processed all-MO transistor arrays (48,400 transistors per square centimetre) and integrated logic gates with uniformity and precision. This technology presents a promising pathway for the cost-effective and high-throughput printing of high-density, complex, multilayered solution-processed MO electronics, delivering performance on par with vacuum-based counterparts.


  • Top Cited Papers
    Open Access

    Skin-interfaced multimodal sensing and tactile feedback system as enhanced human-machine interface for closed-loop drone control

    by Chunki Yiu, Yiming Liu, Wooyoung Park, Jian Li, Xingcan Huang, Kuanming Yao, Yuyu Gao, Guangyao Zhao, Hongwei Chu, Jingkun Zhou, et al.

    Unmanned aerial vehicles have undergone substantial development and market growth recently. With research focusing on improving control strategies for better user experience, feedback systems, which are vital for operator awareness of surroundings and flight status, remain underdeveloped. Current bulky manipulators also hinder accuracy and usability. Here, we present an enhanced human-machine interface based on skin-integrated multimodal sensing and feedback devices for closed-loop drone control. This system captures hand gestures for intuitive, rapid, and precise control. An integrated tactile actuator array translates the drone’s posture into two-dimensional tactile information, enhancing the operator’s perception of the flight situation. Integrated obstacle detection and neuromuscular electrical stimulation–based force feedback system enable collision avoidance and flight path correction. This closed-loop system combines intuitive controls and multimodal feedback to reduce training time and cognitive load while improving flight stability, environmental awareness, and the drone’s posture. The use of stretchable electronics also addresses wearability and bulkiness issues in traditional systems, advancing human-machine interface design.