MUMuhammad Umair

Muhammad Umair

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Muhammad Umair has a total of 118 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Black-Blood Cinematic Rendering of the Pulmonary Vasculature: A Negative-Contrast Intraluminal Preset

    by Haseeb Ur Rehman, Amy Avakian, Muhammad Umair

    Cinematic rendering (CR) is a physically based three-dimensional (3D) computed tomography (CT) visualization technique that has been applied chiefly to the external surface morphology of vascular structures. Intraluminal CR has previously been described for the cardiac chambers as black-blood cinematic rendering (BBCR), in which the opacity assigned to the contrast-enhanced blood pool is suppressed. Here, we describe the adaptation of that principle to the pulmonary vasculature as a negative-contrast intraluminal preset, in which the opacified blood pool is rendered semi-transparent so that the vessel lumen is displayed as a low-signal channel delineated by the enhancing vessel wall. We report the acquisition and rendering conditions under which the appearance was obtained in a single illustrative case performed for chest pain and showing no pulmonary vascular pathology, together with the rendering platform, base preset, and lighting configuration; the attenuation-band settings that define the appearance were tuned for the individual examination rather than applied as a fixed parameter set, were not recorded, and cannot be supplied as numerical values, so a stepwise construction procedure is given in their place. Intermediate rather than maximal compartment-specific opacification was required for the transfer function to separate lumen from wall; the case presented was acquired in an early pulmonary arterial phase, and a late split-bolus acquisition is an alternative route to the same condition that was not used here. In the case presented, the lumen of segmental and up to third-order subsegmental pulmonary arterial and venous branches was visually demonstrated on qualitative assessment by a single reader, and the preset remained stable when applied unchanged across the reconstructed 40–80% R–R window for four-dimensional display, which is a partial rather than a complete cardiac cycle reconstruction. Preset construction was less successful at the central pulmonary arteries and veins, where dense opacification and proximity to the cardiac blood pool reduced the contrast available to the transfer function. This is a single-case technical description. It demonstrates that the appearance can be produced under defined conditions and sets out the procedure by which it was constructed; it does not establish that the exact parameter values are recoverable or transferable, and it does not establish diagnostic performance, which will require prospective comparison against conventional reformats in adequately powered studies.

  • Open Access

    Feasibility and Diagnostic Yield of Left Atrial Appendage Imaging in Comprehensive CT Stroke Protocols

    by Kaitlyn E. Heintzelman, Enrique M. Carrera, Katherine Burkhardt, Haseeb Ur Rehman, Amy Avakian, Muhammad Umair, Ahsan Khan

    Background/Objectives: Cardioembolic sources account for a substantial minority of ischemic strokes, and in non-valvular atrial fibrillation nearly all left atrial thrombi form in the left atrial appendage (LAA). We asked whether extending a standard CT stroke protocol caudally to cover the LAA would add diagnostic yield for LAA thrombus. Methods: We retrospectively reviewed 616 consecutive patients imaged using a revised CT stroke protocol at a single academic center between March 2018 and March 2020. The acquisition was single-phase, arterial and non-gated. Two cardiothoracic radiologists reassessed every study for adequacy of LAA opacification and for thrombus. Acute stroke was confirmed in 418 patients, of whom 342 had adequate opacification and formed the analysis cohort. Clinical characteristics, stroke etiology, echocardiographic results and dose-length product were abstracted. Results: LAA thrombus was identified on CT in 10 of 342 patients (2.9%). Seven underwent transthoracic echocardiography (TTE), and all were negative; none underwent transesophageal echocardiography (TEE). Atrial fibrillation was more frequent in the thrombus cohort (60% vs. 21.1%, p = 0.010). Among the 332 patients without CT thrombus, 265 of 266 TTE and 17 of 18 TEE studies were also negative, and two patients had positive echocardiography despite a negative CT. Mean dose-length product for the extended protocol was 5054.8 ± 2772.5 mGy·cm and did not differ significantly from the standard protocol (p = 0.66). Conclusions: Extending the CT stroke protocol to the LAA was technically feasible and did not significantly increase radiation dose, but added little diagnostic yield. CT-detected thrombus was not confirmed on subsequent echocardiography. Because no patient in the thrombus cohort underwent TEE, these findings are reported as unconfirmed rather than false-positive and no estimate of diagnostic accuracy can be derived. On current evidence, the extended protocol should complement rather than replace echocardiography.

  • Open Access

    Cinematic Rendering of a Fenestrated Patent Foramen Ovale Within a Left-Sided Atrial Septal Pouch

    by Amy Avakian, Muhammad Umair

    Photorealistic cinematic rendering disclosed a fenestrated patent foramen ovale embedded within the otherwise fused inferior wall of a left-sided septal pouch. The fenestrations were not resolvable on conventional axial, multiplanar, or oblique long-axis reformats because of partial volume averaging across the thin septum primum. This case illustrates a diagnostic ceiling of cross-sectional reformatting and a complementary anatomic role for cinematic rendering in thin-tissue interatrial septal pathology.

  • Open Access

    Large Language Models for Patient Education in Cardiovascular Imaging: Prospective Observational Comparative Study

    by Ahmed Marey, Basudha Pal, Ayşenur Buz Yaşar, Shree Rath, Giulia Francese, Hossam M Ghorab, Julia Niemierko, Muhammad Shah Wali Jamal, Muhammad Umair

    Background: Large language models (LLMs) are increasingly used to support digital health communication, yet their reliability in patient-facing cardiovascular imaging education remains uncertain. Cardiovascular imaging involves complex terminology and procedural details that many patients struggle to understand, creating a need for accurate, clear, and reassuring explanations. While prior evaluations of conversational AI have focused primarily on diagnostic reasoning or clinician-oriented tasks, few studies have systematically compared contemporary LLMs in their ability to communicate effectively with patients. Objective: This study aimed to compare the accuracy, clarity, completeness, and patient-centered communication quality of responses generated by 3 state-of-the-art conversational agents (DeepSeek, GPT-o1, and GPT-4o) when addressing real-world patient questions about cardiovascular imaging. Methods: A prospective methodological evaluation was conducted using 84 unique patient-centered questions curated from authoritative cardiovascular information sources and online patient forums. Each question was independently submitted to DeepSeek, GPT-o1, and GPT-4o in isolated sessions to avoid contextual contamination. Two cardiovascular radiologists scored each response across 4 domains (accuracy, clarity and appropriateness, completeness, and user engagement and reassurance) using a standardized 3-point rubric (total score range 4-12). Discrepancies were resolved through predefined adjudication procedures. Because the scores were ordinal, median domain and composite scores with IQRs were summarized and compared across the 3 models using the Kruskal-Wallis test, with ε2 as an effect size. Statistical significance was defined as an α value of .05. Results: Across the 84 patient questions, all 3 models produced largely accurate, clear, and complete responses, with comparably high scores across the accuracy, clarity, and completeness domains (median 3 of 3, IQR 3-3 in each). The only meaningful difference appeared in user engagement and reassurance. A “good” engagement rating was assigned to 96.4% (81/84) of DeepSeek responses and 98.8% (83/84) of GPT-o1 responses but only 53.6% (45/84) of GPT-4o responses (Kruskal-Wallis P<.001). Composite scores were correspondingly lower for GPT-4o (median 11, IQR 10-12) than for DeepSeek and GPT-o1 (both median 12, IQR 11-12; P<.001). No significant differences were observed across models for accuracy (P=.91), clarity (P=.06), or completeness (P=.65), and no unsafe statements were identified in any model. Conclusions: DeepSeek and GPT-o1 consistently delivered accurate, clear, and patient-centered explanations of cardiovascular imaging questions, whereas GPT-4o, despite comparable technical accuracy, provided less engaging and reassuring communication. These findings suggest that affective qualities rather than factual correctness represent the main differentiator among current LLMs in patient education tasks. As conversational agents become integrated into cardiovascular imaging workflows, attention to communication tone, emotional support, and health literacy alignment will be essential to ensure safe and effective patient use.

  • Open Access

    Four-Dimensional Cine Cinematic Rendering of Structural Heart and Mechanical Circulatory Support Devices: An Illustrative Technical Experience

    by Amy Avakian, Muhammad Umair

    Patients with implanted cardiac devices are a rapidly growing imaging population, and electrocardiogram-gated cardiac computed tomography (CT) is increasingly used to characterize device geometry, multi-device relationships, and dynamic behavior across the cardiac cycle. Cinematic rendering (CR) is a photorealistic three-dimensional (3D) visualization technique for cardiac CT whose established contribution in this population is communicative: it conveys 3D device geometry and material distinctions within a single rendered volume. We describe a demonstrative case series extending CR across the cardiac cycle—time-resolved “4D cine” CR—to depict dynamic device behavior and time-resolved multi-device interaction in a single volume; this is an illustrative technical experience rather than a systematic evaluation of diagnostic performance. Illustrative examples include an EVOQUE transcatheter tricuspid valve rendered together with concurrent surgical mitral and transcatheter aortic valves, a left atrial appendage occlusion device, a normally positioned Impella catheter, and a HeartMate 3 left ventricular assist device (LVAD). Across cases, 4D cine CR feasibility scaled inversely with metallic burden—the aggregate volume and radiodensity of metallic device components within the scan field—with renderings informative for low-metal nitinol and catheter devices but substantially degraded by streak artifact in high-metal LVAD housings. This relationship was observed qualitatively in a small selected series and is offered as an initial observation rather than an established characteristic of the technique. We discuss current limitations and emerging directions such as photon-counting detector CT, metal artifact reduction, and artificial-intelligence-assisted post-processing that may extend 4D cine CR in this population.

  • Open Access

    Cinematic Rendering as an Adjunct in Coronary CT Angiography: A Case Series on Myocardial Bridging and Intracameral-Appearing Coronary Courses

    by Yael Sarig, Amy Avakian, Muhammad Umair

    Background/Objectives: Myocardial bridging is a common anatomic variant in which an epicardial coronary artery takes an intramyocardial course. A true intracameral, or intracavitary, coronary course is rare. On coronary CT angiography (CTA), multiplanar and curved planar reformations answer most of these questions, but some cases stay equivocal because of partial-volume effects, cardiac motion, and loss of depth cues. A vessel next to a thin or fat-infiltrated wall can also mimic an intracameral course. Cinematic rendering (CR) is a photorealistic three-dimensional post-processing method that uses Monte Carlo path tracing with global illumination to reproduce natural depth and soft-tissue shading. Methods: In this retrospective, single-center, four-patient case series, we describe patients in whom CR was used alongside standard two-dimensional and reformatted CTA after the planar reconstructions had been read as equivocal. The cases were purposively selected as illustrative examples rather than consecutively enrolled, and the report is intended to be hypothesis-generating. Results: In two patients with left anterior descending (LAD) myocardial bridging, CR showed the tunneled segment with depth and was useful for discussion with referring clinicians and for teaching. In two patients whose coronary segment looked intracameral on planar images, CR showed intact overlying myocardium, which favored an intramyocardial course over chamber entry. Conclusions: In these selected patients, CR did not add anatomic information that was unavailable on expert reformations. It appeared to improve perceived depth and reader confidence in these equivocal cases and was useful for communication and teaching; no quantitative image analysis or formal reader study was performed. Because this is a small, retrospective case series without a comparison group, these observations are illustrative and hypothesis-generating and cannot be extrapolated to coronary CTA in general; prospective comparative studies are needed to determine whether CR adds diagnostic value over standard reconstructions.

  • Open Access

    Four-Dimensional Cinematic Rendering of a Presumed Aortic Valve Papillary Fibroelastoma on Coronary CT Angiography

    by Muhammad Umair, Amy Avakian

    Four-dimensional cinematic rendering represents a convergence of physically based volumetric visualization and time-resolved cardiac imaging, enabling simultaneous assessment of structure and motion within a continuous spatial context. Its application to valvular pathology remains limited. We present a technical implementation of four-dimensional cinematic rendering applied to retrospectively electrocardiographically gated coronary computed tomography angiography for characterization of a presumed aortic valve papillary fibroelastoma. This approach enabled direct visualization of lesion morphology, stalk attachment, and dynamic mobility while preserving spatial relationships to valve cusps and the coronary ostium. In contrast to conventional two-dimensional and static three-dimensional techniques, four-dimensional cinematic rendering provided continuous spatial and temporal coherence, reducing interpretive fragmentation across imaging planes. Used as an adjunct to conventional cross-sectional interpretation, this method allows anatomical detail and functional behavior to be assessed concurrently, with potential implications for risk stratification and procedural planning in valvular disease.

  • Open Access

    Magnetic Particle Imaging for Pulmonary Applications: Technological Advances, Biological Insights, and Clinical Translation

    by Shiva Toumaj, Ahmed Afifi, Muhiddin Dervis, Doaa Mashaly, Abdallah Abudraz, Abdulahi Hassan, Mohamad Rustm, Sachin Jambawalikar, Muhammad Umair

    Background: Magnetic particle imaging (MPI) is an emerging, tracer-based modality that directly detects superparamagnetic iron oxide nanoparticles (SPIONs) with exceptional sensitivity, quantitative signal behavior, and full immunity to air–tissue susceptibility artifacts. These features make MPI particularly well-suited for pulmonary imaging, where traditional techniques such as computed tomography (CT), magnetic resonance imaging (MRI), and nuclear medicine-based ventilation/perfusion (V/Q) imaging are limited by radiation exposure, low contrast, and motion-related signal degradation. Objective: This review synthesizes the current state of MPI for lung imaging, with emphasis on its physical principles, tracer development, preclinical applications, and its potential role in assessing pulmonary perfusion, vascular integrity, inflammation, and therapeutic responses. Methods: A systematic evaluation of preclinical studies was performed across three major application domains: pulmonary perfusion mapping, cell tracking and therapeutic monitoring, and vascular injury and permeability assessment. Study designs, SPION formulations, MPI acquisition strategies, and validation methods, including histopathology, biodistribution, broncho-alveolar lavage fluid (BALF) analysis, and Evans Blue assays, were examined to characterize methodological consistency and imaging performance. Results: MPI consistently demonstrated high-contrast, quantitative visualization of pulmonary blood flow, endothelial barrier disruption, inflammatory signaling, and transplanted or inhaled cell populations. Tracer engineering played a critical role: macroaggregated albumin superparamagnetic iron oxide nanoparticles (MAA-SPIONs) enabled capillary-level perfusion mapping, LS-008 improved temporal resolution and vascular delineation, Synomag/Synomag-D allowed quantification of vascular leakage in acute and chronic lung injury, and vascular cell adhesion molecule-1 (VCAM-1)-targeted probes provided molecular-level assessment of inflammation. Hybrid MPI-CT and MPI-MRI approaches further enhanced anatomic localization and enabled accurate pulmonary blood volume (PBV) estimation. Across studies, MPI measurements showed strong agreement with established biological assays and remained free of the artifacts that limit CT and MRI in the lung. Conclusions: Preclinical evidence demonstrates that MPI is a robust, radiation-free, and quantitatively precise modality for functional and molecular lung imaging. Its ability to map perfusion, track therapeutic agents, and noninvasively quantify vascular permeability positions MPI as a promising future alternative or complement to CT, MRI, and nuclear medicine for pulmonary assessment. Continued tracer optimization, system scaling, and clinical validation are key steps toward translating MPI into routine clinical use.


  • Influence of computed tomography reconstruction algorithms on coronary artery calcium scores and reader agreement

    by Lee D. Yang, Yosef A. Cohen, Todd C. Pulerwitz, Benjamin Navot, Kevin J. O'GOrman, Michelle Castillo, Julia S. Bauer, Kenton P. Kaplan, Luca Bremner, Boyu Peng, et al.