TKTodd Kozlowski

Todd Kozlowski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Todd Kozlowski has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Absolute length sensing in a long-baseline, high-finesse optical cavity

    by Todd Kozlowski, Henry Frädrich, Aaron D. Spector

    The relative phase between two lasers in the transmission of an optical cavity can be used to continuously measure its absolute length with sub-micron precision. The first laser is kept on resonance with the cavity, while a second laser is phase-locked to the first with a frequency separation equal to an integer multiple of the cavity’s initial free spectral range. As the free spectral range frequency changes due to cavity length changes, the second laser de-tunes slightly from resonance and gains an additional phase offset in the transmission of the cavity. The cavity length changes can be calibrated in terms of this phase offset. This technique is applied to a high-finesse optical cavity with a length of 123 m, transforming it into a strainmeter with nanostrain sensitivity to long-term and transient seismic events. We report absolute length changes associated with anthropogenic noise, a distant earthquake, and the diurnal and semidiurnal earth tides.

  • Open Access

    Demonstration of an interferometric technique for measuring vacuum magnetic birefringence with an optical cavity

    by Aaron D. Spector, Todd Kozlowski, Laura Roberts

    Vacuum magnetic birefringence (VMB) is an effect predicted by quantum electrodynamics in which the vacuum behaves as a nonlinear optical medium and exhibits a birefringence in the presence of a magnetic field. In this work, an interferometric scheme is introduced to measure this effect by sensing the changes in the frequencies of fields stabilized to the resonances of an optical cavity. Results are presented from a prototype setup with this sensing technique implemented on a 19-m test cavity without a magnetic field. We propose using this scheme for a measurement of VMB with a 245-m-long optical cavity and a string of 24 superconducting magnets, arranged for the ALPS II experiment. In this manuscript we examine potential sources of noise in the prototype and project these results in terms of the sensitivity of the full-scale experiment.


  • Open Access

    Design and performance of the ALPS II regeneration cavity

    by Todd Kozlowski, Li-Wei Wei, Aaron D. Spector, Ayman Hallal, Henry Fraedrich, Daniel C. Brotherton, Isabella Oceano, Aldo Ejlli, Hartmut Grote, Harold Hollis, et al.

    The regeneration cavity (RC) is a critical component of the Any Light Particle Search II (ALPS II) experiment. It increases the signal from possible axions and axion-like particles in the experiment by nearly four orders of magnitude. The total round-trip optical losses of the power circulating in the cavity must be minimized in order to maximize the resonant enhancement of the cavity, which is an important figure of merit for ALPS II. Lower optical losses also increase the cavity storage time, and with the 123 meter long ALPS II RC we have demonstrated the longest storage time of a two-mirror optical cavity. We measured a storage time of 7.17±0.01ms, equivalent to a linewidth of 44.4 Hz and a finesse of 27,500 at a wavelength of 1064 nm.


  • Open Access

    Optical cavity characterization with a mode-matched heterodyne sensing scheme

    by Aaron D. Spector, Todd Kozlowski

    We describe a technique for measuring the complex reflectivity of an optical cavity with a resonant local oscillator laser and an auxiliary probe laser, each coupled via opposite ends of the cavity. A heterodyne sensing scheme is then used to observe the phase and amplitude of the interference beat-note between the promptly reflected field and the cavity-transmitted field injected through the far mirror. Since the local oscillator laser must pass through the cavity before interfering with the probe laser these measurements are not only independent of the spatial coupling of either laser to the cavity, but also obtained at the in-situ position of the cavity eigenmode. This technique was demonstrated on a 19 m cavity to measure the individual transmissivities of each of the mirrors as well as the round-trip optical losses to an accuracy of several parts per million.


  • Design of the ALPS II optical system

    by M. Diaz Ortiz, J. Gleason, H. Grote, A. Hallal, M.T. Hartman, H. Hollis, K.-S. Isleif, A. James, K. Karan, T. Kozlowski, et al.