DDDevakumar Devadhas

Devakumar Devadhas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Devakumar Devadhas has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Accuracy and Precision of Bone Scan, Magnetic Resonance Imaging (MRI) and Digital Radiography in Limb Salvage Surgery for Long Bone Tumors

    by Gomadam Kuppusamy Rangarajan, Ramachandran Krishnakumar, Devakumar Devadhas, Murugesan Karthigaiselvi, Krishnan Chandrakumar, Anand Raja

    Introduction: The aim of this study is to evaluate the level of accuracy and precision of bone scan (BS), magnetic resonance imaging (MRI) and digital radiography (DR) to measure long bone tumors to design custom made prosthesis (CMP)/modular prosthesis (MP) in limb salvage surgery (LSS). Material and methods: There are two separate groups, one is phantom study and another one is patient’s study. Phantom study: done with Jaszack phantom for gamma camera (GC) and indigenous phantom for MRI and DR. Three independent imaging professionals (nuclear medicine physicians and radiologists) measured the distance between standardized, preselected points on the Jaszack phantom in the GC and indigenous phantom on the coronal and sagittal view of the MRI scan and in DR. The measured values were compared it with the known values for phantom measurement. Patient’s study: Patients with a malignant bone tumor of the lower/upper limbs enrolled from 2020-2021 at the institute were taken up for the retrospective study. Totally 36 patients were enrolled, 24 patients were male (Ages: 2 to 45 years) and 12 patients were female (Ages: 8 to 18 years). Three independent imaging professionals measured the patient’s long bone in the BS, MRI and DR and compared with histopathological specimen measurement after LSS. Statistical analysis: Descriptive statistics using appropriate measures of central tendency, dispersion, Karl-Pearson correlation coefficient and paired t-test were employed. Results: A near perfect positive correlation was evident between all three pairs of the BS, MRI scan and DR values and a positive agreement within 1 mm was around 95%. Conclusion: For the phantom study, we conclude that GC and MRI measurements are equal in physical measurements and multiplication correction factor (MCF) = 1. DR measurements were found to be near equal physical measurements and MCF = 0.9104 and three observer’s measurements values were also near normal.

  • Correction to: Influence of Accuracy and Precision of Measurements of Long Bone Tumors in Imaging Studies—A Retrospective Study in Musculoskeletal Oncology

    by G. K. Rangarajan, R. Krishnakumar, D. Devakumar, M. Karthigaiselvi, Anand Raja, Chandrakumar Krishnan

    [This corrects the article DOI: 10.1007/s13193-022-01699-0.].

  • Influence of Accuracy and Precision of Measurements of Long Bone Tumors in Imaging Studies—A Retrospective Study in Musculoskeletal Oncology

    by G. K. Rangarajan, R. Krishnakumar, D. Devakumar, M. Karthigaiselvi, Anand Raja, Chandrakumar Krishnan

    The aim of this study is to evaluate the level of accuracy and precision of bone scan (BS), MRI, and digital radiography (DR) to measure long bone tumors to design custom-made prosthesis (CMP)/modular prosthesis (MP) in limb salvage surgery (LSS) with the help of phantom and patient’s study. There are two separate groups: one is the phantom study and another one is the patient’s study. The phantom study is done with the Jaszack Phantom for the Gamma camera and the indigenous phantom for the MRI and DR. Three independent imaging professionals (nuclear medicine physicians and radiologists) measured the distance between standardized, preselected points on the Jaszack phantom in the Gamma Camera (GC) and indigenous phantom on the coronal and sagittal view of the MRI scan and in digital radiography. The measured values were compared with the known values for phantom measurement. A total of 36 patients, which include 24 males and 12 females, 3 independent imaging professionals measured the patient’s long bone in a bone scan, MRI and DR and compared it with histopathological specimen measurement after limb salvage surgery (LSS). Descriptive statistics using appropriate measures of central tendency and dispersion were employed to describe the data. Karl-Pearson correlation coefficient was used to establish the association between continuous covariates. Paired t-test was utilized to test the differences in paired values for statistical significance. A near-perfect positive correlation was evident between all three pairs of bone scan, MRI scan, and digital radiography values, and a positive agreement within 1 mm of the bone scan, MRI scan, and DR values of all three pairs was around 95%. For the phantom study, we conclude that Gamma camera and MRI measurements are equal in physical measurements (MCF-1). DR measurements were found to be near equal physical measurements and multiplication correction factor (MCF)—0.9104 and three observer’s measurements values were also near normal. For the patient’s study, we conclude that the bone scan, MRI, and DR measurements of 3 independent imaging professionals are near normal, and it was confirmed with pathological specimen after LSS, to confirm reliability, repeatability, reproducibility, and accuracy of the tumor length to do custom-made prosthesis or modular prosthesis for the patients who are affected by osteosarcoma and Ewing’s sarcoma.

  • Customized cost-effective polymethylmethacrylate cranioplasty: a cosmetic comparison with other low-cost methods of cranioplasty

    by Manish Baldia, Mathew Joseph, Suryaprakash Sharma, Deva Kumar, Ashwin Retnam, Santosh Koshy, Reka Karuppusami

    Background Intraoperative hand-moulded cranioplasty and polymethylmethacrylate (PMMA) prostheses made from bone impressions are economical but the cosmetic results are less than satisfactory. Commercially available customized prostheses perform better but are prohibitively expensive. We evaluate the performance of a locally developed, low-cost customized PMMA cranioplasty prosthesis. Objective To compare the cosmetic outcome of 3 types of PMMA cranioplasty as well as with objective measurements on postoperative CT scans Methods This study includes 70 patients who underwent cranioplasty between March 2016 and June 2020. In this period, patients had their cranioplasty prostheses made by intra-operative hand moulding (HM), by using the removed bone as a template and making a bone impression (BI) or by 3D printing the prosthesis based on a CT scan. Cosmetic outcomes were assessed by the patient and the operating surgeon on an 8-point scale. The degree of measured anthropometric asymmetry was measured on a postoperative CT scan and correlated with the cosmetic outcome. Results Our locally produced 3D-printed cranioplasty prostheses showed a statistically better performance in cosmetic scores when compared to the HM and BI (p value < 0.001). CT anthropometric measurements significantly correlated with cosmetic outcome (p value 0.01) Conclusion Our 3D cranioplasty prostheses had better cosmetic outcomes than HM and BI prostheses, and our technique is able to produce them at 10% of the cost of the currently available commercial customized prostheses.