Jennifer Stefani Weber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jennifer Stefani Weber has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Alejandro Figueroa
Postgraduate Program in Materials Science and Engineering (PPGMAT), Universidade de Caxias do Sul (UCS), Caxias do Sul, 95070-560, RS, Brazil
7 shared publications - Alexandre Fassini Michels
PPGMAT, Universidade de Caxias do Sul (UCS), Caxias do Sul, Brazil
6 shared publications - Bruna Louise Perotti
PPGMAT
5 shared publications - Carla Daniela Boeira
Universidade Estadual de Campinas (UNICAMP), Instituto de Física ‘Gleb Wataghin’, Campinas, Brazil
4 shared publications - Michael Cristian Goldbeck
PPGMAT
4 shared publications - Vanessa Piroli
Programa de Pós‐Graduação em Engenharia e Ciência dos Materiais (PPGMAT) Universidade de Caxias do Sul (UCS) Caxias do Sul Brazil
4 shared publications
Latest Publications
- 2 April 2026
- Published by Elsevier in Applied Surface Science
- Vol. 736
Unveiling the role of oxygen in SiC/Fe interfacial adhesion: a combined experimental and DFT study
- 2 April 2026
- Published by Elsevier in Applied Surface Science
- Vol. 736
Unveiling the role of oxygen in SiC/Fe interfacial adhesion: a combined experimental and DFT study
- Open Access
- 21 March 2026
- Published by Elsevier in Applied Surface Science Advances
- Vol. 33
Phototribology of copper surfaces
- 21 March 2026
- Published by Elsevier in Applied Surface Science Advances
- Vol. 33
Open AccessPhototribology of copper surfaces
- Open Access
- 16 January 2026
- Published by Wiley in Surface and Interface Analysis
- Vol. 58 (4) , 246-261
Amorphous Hydrogenated Silicon Carbide Interlayers: Chemical, Optical, and Tribological Behavior for Improving Adhesion of Carbon‐Based Films to Ferrous Alloy
Diamond‐like carbon thin films have been gaining attention in the last years due to their unique properties, such as low friction coefficient and high wear resistance. However, the lack of adhesion between DLC coatings and ferrous alloys complicates their wider industrial application. Amorphous hydrogenated silicon carbide (a‐SiC x :H) interlayers can be used as a solution for adhesion issues. Nonetheless, for interlayers produced with tetramethylsilane, deposition temperatures higher than 300°C may degrade the previous heat treatment of the substrate. This work aims to verify the influence of chemical, optical, morphological, and tribological properties in the adhesion of a‐C:H/a‐SiC x :H/AISI 4140 steel structures deposited with 0.8 Pa as background pressure and low interlayer deposition temperatures ( T ≤ 200°C). The results showed that both chemical and morphological properties strongly modify the adhesion behavior at low deposition temperatures. The optical absorption edge of the samples takes place in energies around 3.5 (or ~350 nm) and ~1.5 eV (or ~850 nm) for the a‐SiC x :H interlayer (mainly deposited at 150°C) and a‐C:H film deposited for 60 min, respectively. When the a‐SiC x :H temperature increased from 85°C to 200°C, the oxygen content at the interfaces and in the interlayer decreased as well as the density of defects observed in the a‐C:H surface.
- 16 January 2026
- Published by Wiley in Surface and Interface Analysis
- Vol. 58 (4) , 246-261
Open AccessAmorphous Hydrogenated Silicon Carbide Interlayers: Chemical, Optical, and Tribological Behavior for Improving Adhesion of Carbon‐Based Films to Ferrous Alloy
Diamond‐like carbon thin films have been gaining attention in the last years due to their unique properties, such as low friction coefficient and high wear resistance. However, the lack of adhesion between DLC coatings and ferrous alloys complicates their wider industrial application. Amorphous hydrogenated silicon carbide (a‐SiC x :H) interlayers can be used as a solution for adhesion issues. Nonetheless, for interlayers produced with tetramethylsilane, deposition temperatures higher than 300°C may degrade the previous heat treatment of the substrate. This work aims to verify the influence of chemical, optical, morphological, and tribological properties in the adhesion of a‐C:H/a‐SiC x :H/AISI 4140 steel structures deposited with 0.8 Pa as background pressure and low interlayer deposition temperatures ( T ≤ 200°C). The results showed that both chemical and morphological properties strongly modify the adhesion behavior at low deposition temperatures. The optical absorption edge of the samples takes place in energies around 3.5 (or ~350 nm) and ~1.5 eV (or ~850 nm) for the a‐SiC x :H interlayer (mainly deposited at 150°C) and a‐C:H film deposited for 60 min, respectively. When the a‐SiC x :H temperature increased from 85°C to 200°C, the oxygen content at the interfaces and in the interlayer decreased as well as the density of defects observed in the a‐C:H surface.
- Open Access
- 22 July 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (30) , 33636-33644
Silicon and Silver Low-Energy Ion Implantation into Titanium Plates for Improved Biocompatibility
Surface modification of implant materials continues to address the issue of osseointegration. Moreover, combining osseointegration with bactericidal or antifouling properties in implants remains an open question for debate. Over the years, silver has been widely used as an agent for killing and preventing bacterial proliferation. Silicon, on the other hand, has been linked to improved osteogenic activity. In this work, titanium plates were incorporated with both Ag and Si ions through low-energy ion implantation, and surface characterization was carried out to validate the process. Ti plates containing 43 μg cm–2 Ag were further enriched with small amounts of Si, as verified by glow discharge optical emission spectroscopy (GD-OES) and energy-dispersive X-ray spectroscopy (EDS). This added step increased surface roughness by approximately 11% and led to a statistically significant difference in wettability, rendering hydrophilic features (from angles around 90° to below 70° for the Ag + Si condition)both of which influence biocompatibility. Electrochemical tests showed a more reactive surface for implanted samples but nonetheless demonstrated stability over 28 days. Further research should focus on increasing the Si doping in Ti and evaluating subsequent in vitro conditions.
- 22 July 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (30) , 33636-33644
Open AccessSilicon and Silver Low-Energy Ion Implantation into Titanium Plates for Improved Biocompatibility
Surface modification of implant materials continues to address the issue of osseointegration. Moreover, combining osseointegration with bactericidal or antifouling properties in implants remains an open question for debate. Over the years, silver has been widely used as an agent for killing and preventing bacterial proliferation. Silicon, on the other hand, has been linked to improved osteogenic activity. In this work, titanium plates were incorporated with both Ag and Si ions through low-energy ion implantation, and surface characterization was carried out to validate the process. Ti plates containing 43 μg cm–2 Ag were further enriched with small amounts of Si, as verified by glow discharge optical emission spectroscopy (GD-OES) and energy-dispersive X-ray spectroscopy (EDS). This added step increased surface roughness by approximately 11% and led to a statistically significant difference in wettability, rendering hydrophilic features (from angles around 90° to below 70° for the Ag + Si condition)both of which influence biocompatibility. Electrochemical tests showed a more reactive surface for implanted samples but nonetheless demonstrated stability over 28 days. Further research should focus on increasing the Si doping in Ti and evaluating subsequent in vitro conditions.
- 25 July 2024
- Published by Wiley in Surface and Interface Analysis
- Vol. 56 (11) , 770-780
Influence of the base pressure in deposition of a‐SiCx interlayers for adhesion of Diamond‐Like Carbon on metallic alloy
Diamond‐like carbon (DLC) is an amorphous material widely used in industrial applications due to its chemical, mechanical, and tribological properties and, also, for decorative purposes. However, its low adhesion to ferrous alloys reduces its effectiveness in certain applications, necessitating the use of adhesion interlayers to reduce stresses at the interfaces and enhance the density of strong bonds. In this context, the factors that promote good adhesion in this system and specify the parameters must be understood in detail. Thus, the present study aims to assess the influence of the base pressure on the deposition of an amorphous silicon carbide adhesion interlayer between DLC coating and a ferrous alloy substrate. Microstructural, physicochemical, morphological, and mechanotribological analyses were conducted to understand the adhesion behavior in terms of structural and chemical aspects. In addition to the influence of the interlayer thickness, the elemental Si/C ratios and the relative oxygen content have an impact on the maximum load supported by the coatings, as well as the different delamination mechanisms generated in adhesion tests.
- 25 July 2024
- Published by Wiley in Surface and Interface Analysis
- Vol. 56 (11) , 770-780
Influence of the base pressure in deposition of a‐SiCx interlayers for adhesion of Diamond‐Like Carbon on metallic alloy
Diamond‐like carbon (DLC) is an amorphous material widely used in industrial applications due to its chemical, mechanical, and tribological properties and, also, for decorative purposes. However, its low adhesion to ferrous alloys reduces its effectiveness in certain applications, necessitating the use of adhesion interlayers to reduce stresses at the interfaces and enhance the density of strong bonds. In this context, the factors that promote good adhesion in this system and specify the parameters must be understood in detail. Thus, the present study aims to assess the influence of the base pressure on the deposition of an amorphous silicon carbide adhesion interlayer between DLC coating and a ferrous alloy substrate. Microstructural, physicochemical, morphological, and mechanotribological analyses were conducted to understand the adhesion behavior in terms of structural and chemical aspects. In addition to the influence of the interlayer thickness, the elemental Si/C ratios and the relative oxygen content have an impact on the maximum load supported by the coatings, as well as the different delamination mechanisms generated in adhesion tests.
- Open Access
- 28 February 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 42 (2)
Bias voltage influence on the a-SiCx:H interlayer deposition using tetramethylsilane: Decorative applications of a-C:H thin films on steel
Hydrogenated amorphous carbon (a-C:H) is a type of coating vastly applied on steel alloys due to its low friction coefficient, high hardness, and chemical inertness. Also, its characteristic brilliant black color like onyx stone is desirable for decorative applications. Despite the beneficial properties conferred to ferrous substrates, the adhesion of a-C:H films is weakened by its residual stress. In order to improve the adhesion of a-C:H films/steel alloy structures, one adopted strategy is the addition of an interlayer. This research investigated the influence of the bias voltage applied on the deposition of hydrogenated amorphous silicon carbide (a-SiCx:H) interlayers, with tetramethylsilane (TMS) as the precursor, to promote adhesion in a-C:H/a-SiCx:H/ferrous alloy structures for decorative applications. The thicker interlayer was achieved at −600 V. Two regimes were proposed to explain this behavior considering ionization rates and resputtering rates and chemical reactions in plasma. The chemical structure in different regions of the a-SiCx:H interlayer was analyzed in detail. An increase in the applied bias voltage leads to oxygen incorporation at the a-C:H/a-SiCx:H interface. Higher bias voltages result in lower silicon content at the a-SiCx:H/steel interface, which is correlated to the −800 V sample’s poor adhesion. Finally, we have included a discussion about a new range of loads when a decorative piece is held by the hand where the critical loads for delamination of a-C:H coatings measured here are good enough for decorative applications.
- 28 February 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 42 (2)
Open AccessBias voltage influence on the a-SiCx:H interlayer deposition using tetramethylsilane: Decorative applications of a-C:H thin films on steel
Hydrogenated amorphous carbon (a-C:H) is a type of coating vastly applied on steel alloys due to its low friction coefficient, high hardness, and chemical inertness. Also, its characteristic brilliant black color like onyx stone is desirable for decorative applications. Despite the beneficial properties conferred to ferrous substrates, the adhesion of a-C:H films is weakened by its residual stress. In order to improve the adhesion of a-C:H films/steel alloy structures, one adopted strategy is the addition of an interlayer. This research investigated the influence of the bias voltage applied on the deposition of hydrogenated amorphous silicon carbide (a-SiCx:H) interlayers, with tetramethylsilane (TMS) as the precursor, to promote adhesion in a-C:H/a-SiCx:H/ferrous alloy structures for decorative applications. The thicker interlayer was achieved at −600 V. Two regimes were proposed to explain this behavior considering ionization rates and resputtering rates and chemical reactions in plasma. The chemical structure in different regions of the a-SiCx:H interlayer was analyzed in detail. An increase in the applied bias voltage leads to oxygen incorporation at the a-C:H/a-SiCx:H interface. Higher bias voltages result in lower silicon content at the a-SiCx:H/steel interface, which is correlated to the −800 V sample’s poor adhesion. Finally, we have included a discussion about a new range of loads when a decorative piece is held by the hand where the critical loads for delamination of a-C:H coatings measured here are good enough for decorative applications.
- 22 September 2023
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 41 (6)
Si-containing interlayer using tetramethylsilene for diamondlike carbon film adhesion on low-alloy steel: The role of the interlayer deposition time
Diamondlike carbon (DLC) coatings provide interesting properties for industrial applications. However, the low adhesion of DLC coatings on any type of ferrous alloy compromises technological applications. One possible solution to this issue is the application of adhesion interlayers. The aim of this study is to investigate the adhesion of DLC films on low-alloy steel through the use of silicon-containing interlayers at different deposition times using tetramethylsilane. The role of time on the physical-chemical, microstructural, and tribological properties of the material system was evaluated. The interlayer thickness linearly increased and greater contributions of silicon bonds were measured as a function of the interlayer deposition time. Nevertheless, longer deposition times increased the roughness and defect ratio in DLC coatings. Although good enough adhesion for decorative applications was acquired, no drastic variation in the average critical load (∼4.2 N) for delamination was observed at different deposition times for the samples that achieved adhesion.
- 22 September 2023
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 41 (6)
Si-containing interlayer using tetramethylsilene for diamondlike carbon film adhesion on low-alloy steel: The role of the interlayer deposition time
Diamondlike carbon (DLC) coatings provide interesting properties for industrial applications. However, the low adhesion of DLC coatings on any type of ferrous alloy compromises technological applications. One possible solution to this issue is the application of adhesion interlayers. The aim of this study is to investigate the adhesion of DLC films on low-alloy steel through the use of silicon-containing interlayers at different deposition times using tetramethylsilane. The role of time on the physical-chemical, microstructural, and tribological properties of the material system was evaluated. The interlayer thickness linearly increased and greater contributions of silicon bonds were measured as a function of the interlayer deposition time. Nevertheless, longer deposition times increased the roughness and defect ratio in DLC coatings. Although good enough adhesion for decorative applications was acquired, no drastic variation in the average critical load (∼4.2 N) for delamination was observed at different deposition times for the samples that achieved adhesion.
- 7 March 2022
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 5 (3) , 3763-3772
Adhesion of Amorphous Carbon Nanofilms on Ferrous Alloy Substrates Using a Nanoscale Silicon Interlayer: Implications for Solid-State Lubrication
- 7 March 2022
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 5 (3) , 3763-3772
Adhesion of Amorphous Carbon Nanofilms on Ferrous Alloy Substrates Using a Nanoscale Silicon Interlayer: Implications for Solid-State Lubrication