Nívea Rosa de Morais
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nívea Rosa de Morais has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Camilla Medeiros Araujo
Physiotherapy Department Universidade Federal de Pernambuco (UFPE) Recife Brazil
2 shared publications - Cinara Sacomori
Facultad de Medicina Clinica Alemana, Universidad del Desarrollo, Santiago, Chile
2 shared publications - Diego de Sousa Dantas
Department of Physiotherapy, Federal University of Pernambuco (UFPE), Recife, Brazil
2 shared publications
Latest Publications
- 17 July 2022
- Published by Wiley in Neurourology and Urodynamics
- Vol. 41 (7) , 1631-1632
Response to: Symptoms assessed by pad test for urinary incontinence depend on pressure generated for diagnostic test accuracy
- 17 July 2022
- Published by Wiley in Neurourology and Urodynamics
- Vol. 41 (7) , 1631-1632
Response to: Symptoms assessed by pad test for urinary incontinence depend on pressure generated for diagnostic test accuracy
- 3 February 2022
- Published by Wiley in Neurourology and Urodynamics
- Vol. 41 (3) , 696-709
Pad test for urinary incontinence diagnosis in adults: Systematic review of diagnostic test accuracy
Introduction: The pad test is an assessment tool for urinary incontinence (UI) severity classification and therapeutic response monitoring. However, the reliability and reproducibility of this test have been questioned.Objectives: To summarize the evidence regarding the accuracy measures and reproducibility of different pad test protocols for assessing UI.Methods: A systematic review of the diagnostic accuracy of this tool was performed (CRD42020219392). Eligibility criteria: Studies reporting data on the accuracy measures and reproducibility of the pad test when used for detecting UI in adult men and women. Data sources: MEDLINE, Science Direct, Cochrane, Web of Science, LILACS, and Pedro. Data extraction and synthesis: Two reviewers independently screened the articles, extracted the data, and evaluated the risk of bias (RoB) using the QUADAS‐2 tool.Results: From 1048 studies, 18 studies were included. Eight of these reported accuracy data, and 12 reported reproducibility properties. A total of 1070 individuals were analyzed, whose mean age ranged from 20 to 90 years. The accuracy of the long‐duration protocols was generally moderate to high (sensitivity, 60%–93%; specificity, 60%–84%). The 1‐h protocols obtained higher accuracy values. The overall reproducibility was moderate to high (κ ≥ 0.66).Limitations: The RoB was high and, due to different cutoff points adopted by studies, the bivariate model was not satisfied to perform a meta‐analysis.Discussion: The 1‐h pad test was more accurate but less reproducible when compared to the long‐duration tests. Pad test results should be used with caution in clinical practice.
- 3 February 2022
- Published by Wiley in Neurourology and Urodynamics
- Vol. 41 (3) , 696-709
Pad test for urinary incontinence diagnosis in adults: Systematic review of diagnostic test accuracy
Introduction: The pad test is an assessment tool for urinary incontinence (UI) severity classification and therapeutic response monitoring. However, the reliability and reproducibility of this test have been questioned.Objectives: To summarize the evidence regarding the accuracy measures and reproducibility of different pad test protocols for assessing UI.Methods: A systematic review of the diagnostic accuracy of this tool was performed (CRD42020219392). Eligibility criteria: Studies reporting data on the accuracy measures and reproducibility of the pad test when used for detecting UI in adult men and women. Data sources: MEDLINE, Science Direct, Cochrane, Web of Science, LILACS, and Pedro. Data extraction and synthesis: Two reviewers independently screened the articles, extracted the data, and evaluated the risk of bias (RoB) using the QUADAS‐2 tool.Results: From 1048 studies, 18 studies were included. Eight of these reported accuracy data, and 12 reported reproducibility properties. A total of 1070 individuals were analyzed, whose mean age ranged from 20 to 90 years. The accuracy of the long‐duration protocols was generally moderate to high (sensitivity, 60%–93%; specificity, 60%–84%). The 1‐h protocols obtained higher accuracy values. The overall reproducibility was moderate to high (κ ≥ 0.66).Limitations: The RoB was high and, due to different cutoff points adopted by studies, the bivariate model was not satisfied to perform a meta‐analysis.Discussion: The 1‐h pad test was more accurate but less reproducible when compared to the long‐duration tests. Pad test results should be used with caution in clinical practice.