Megat Muhammad Ikhsan Megat Hasnan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Megat Muhammad Ikhsan Megat Hasnan has a total of 155 co-authors. Here are the top co-authors by number of shared publications:
- Suhana Mohd Said
Department of Electrical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia
9 shared publications - Hazlihan Haris
Universiti Malaysia Sabah
6 shared publications - Ismail Saad
Universiti Malaysia Sabah
6 shared publications - Mohd Faizul Mohd Sabri
Department of Mechanical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia
6 shared publications - Nafarizal Nayan
Faculty of Electrical and Electronic Engineering Universiti Tun Hussein Onn Malaysia 86400 Johor Malaysia
6 shared publications - Ahmad Razif Muhammad
Universiti Kebangsaan Malaysia
5 shared publications
Latest Publications
- 3 June 2026
- Published by Springer Nature
- p. 220-230
Thermally Driven Electrical Response of Cobalt(ii) Spin Crossover/Graphene Oxide Composite Devices
- 3 June 2026
- Published by Springer Nature
- p. 220-230
Thermally Driven Electrical Response of Cobalt(ii) Spin Crossover/Graphene Oxide Composite Devices
- 27 May 2025
- Published by Springer Nature
- p. 67-73
Investigation of Aqueous Sea Salt Thermoelectrochemical Power Generation Using Graphene Nanoplatelet Additive
- 27 May 2025
- Published by Springer Nature
- p. 67-73
Investigation of Aqueous Sea Salt Thermoelectrochemical Power Generation Using Graphene Nanoplatelet Additive
- 14 March 2025
- Published by Springer Nature in Ionics
- Vol. 31  (5) , 4853-4873
Electrochemical properties of Fe(II) spincrossover complexes in different spin states: an investigation through electrochemical impedance spectroscopy
- 14 March 2025
- Published by Springer Nature in Ionics
- Vol. 31  (5) , 4853-4873
Electrochemical properties of Fe(II) spincrossover complexes in different spin states: an investigation through electrochemical impedance spectroscopy
- Open Access
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 13  (6) , 3976-3982
Dissipative soliton generation with sidebands using Bismuth Telluride (Bi2Te3) in erbium doped fiber laser
In this work, the demonstration of dissipative soliton (DS) was observed in erbium doped fiber laser (EDFL) using of Bismuth Telluride (Bi2Te3) nanosheets saturable absorber (SA). The prepared SA was deposited on a fiber ferrule using optical deposition method. Interestingly, the DS generatered was accompanied with sidebands and the number of sidebands grew with laser diode pump power. Sidebands were observed as a result of modulation instability (MI) process, which arises from the interaction between DS and nonlinear gain in the fiber laser cavity. Signal to noise ratio (SNR) of 58 dB was attained, confirming the stability of the generated pulse. This work proved the capability of Bi2Te3 as SA for generating DS with sidebands in an EDFL.
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 13  (6) , 3976-3982
Open AccessDissipative soliton generation with sidebands using Bismuth Telluride (Bi2Te3) in erbium doped fiber laser
In this work, the demonstration of dissipative soliton (DS) was observed in erbium doped fiber laser (EDFL) using of Bismuth Telluride (Bi2Te3) nanosheets saturable absorber (SA). The prepared SA was deposited on a fiber ferrule using optical deposition method. Interestingly, the DS generatered was accompanied with sidebands and the number of sidebands grew with laser diode pump power. Sidebands were observed as a result of modulation instability (MI) process, which arises from the interaction between DS and nonlinear gain in the fiber laser cavity. Signal to noise ratio (SNR) of 58 dB was attained, confirming the stability of the generated pulse. This work proved the capability of Bi2Te3 as SA for generating DS with sidebands in an EDFL.
- Open Access
- 30 October 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Mechanics
- Vol. 126  (1) , 178-187
Brain Tumor Detection and Size Estimation using Microwave Imaging
This project focuses on developing an antenna that utilising microwave imaging technology for visualising, detecting, and estimating the size of human tumors using simulation approach. A rectangular microstrip patch antenna is chosen for its advantages of low cost, convenience, efficiency, and compactness, offering a non-ionised alternative. To meet the antenna specifications, rectangular slots are incorporated into the design. The antenna performs effectively at 7.5 GHz, exhibiting a return loss of -24.20383 dB, well below the -10 dB threshold. Placing the antenna 15 mm away from the human brain model results in a specific absorption rate (SAR) value of 0.2 W/kg for 10g, indicating its safety for brain imaging. By scanning a human head phantom with and without a tumor, the antenna captures reflected signals from different locations, enabling the generation of tumour images. A 10-mm-radius tumor is introduced to the phantom, and the unique reflected signal serves as an indicator for tumor detection, using the signal without a tumor as a reference. MATLAB software is employed for image processing, allowing the generation of tumour images and the estimation of tumor size. The simulation results demonstrate 63% accuracy in tumor size estimation. In conclusion, the antenna proves to be a safe and effective brain imaging system for tumor detection.
- 30 October 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Mechanics
- Vol. 126  (1) , 178-187
Open AccessBrain Tumor Detection and Size Estimation using Microwave Imaging
This project focuses on developing an antenna that utilising microwave imaging technology for visualising, detecting, and estimating the size of human tumors using simulation approach. A rectangular microstrip patch antenna is chosen for its advantages of low cost, convenience, efficiency, and compactness, offering a non-ionised alternative. To meet the antenna specifications, rectangular slots are incorporated into the design. The antenna performs effectively at 7.5 GHz, exhibiting a return loss of -24.20383 dB, well below the -10 dB threshold. Placing the antenna 15 mm away from the human brain model results in a specific absorption rate (SAR) value of 0.2 W/kg for 10g, indicating its safety for brain imaging. By scanning a human head phantom with and without a tumor, the antenna captures reflected signals from different locations, enabling the generation of tumour images. A 10-mm-radius tumor is introduced to the phantom, and the unique reflected signal serves as an indicator for tumor detection, using the signal without a tumor as a reference. MATLAB software is employed for image processing, allowing the generation of tumour images and the estimation of tumor size. The simulation results demonstrate 63% accuracy in tumor size estimation. In conclusion, the antenna proves to be a safe and effective brain imaging system for tumor detection.
- Open Access
- 31 March 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Mechanics
- Vol. 115  (1) , 131-140
Investigation Seebeck Effect of Industrial High Voltage Transformer Oil Towards Industrial Insulator Oil Condition Detection
Transformer oil serves as the main dielectric and interacts with solid insulation, encounters the environment, and conveys a lot of information. However, undesirable contamination of transformer oil like water or moisture in the transformer oil will reduce the transformer's effectiveness. This study is the first investigation of the potential of using the thermoelectric effect for transformer oil condition testing towards high voltage insulator oil condition detection. This study has found that the used oil sample with various percentages of water content produced a different Seebeck coefficient which shows the potential of using the thermoelectric effect as a simple, cheap, and versatile method to test industrial oil insulator conditions. The results of the Seebeck coefficient for each condition are 0.0003 mV/K (original), 0.0107 mV/K (4 % of water added), and 0.0131 mV/K (40 % of water added), respectively. The industrial oil shows different Seebeck magnitude between oil before and after thermal aging which show a significant decrease of Seebeck magnitude of the industrial oil insulator with an increase of thermal ageing.
- 31 March 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Mechanics
- Vol. 115  (1) , 131-140
Open AccessInvestigation Seebeck Effect of Industrial High Voltage Transformer Oil Towards Industrial Insulator Oil Condition Detection
Transformer oil serves as the main dielectric and interacts with solid insulation, encounters the environment, and conveys a lot of information. However, undesirable contamination of transformer oil like water or moisture in the transformer oil will reduce the transformer's effectiveness. This study is the first investigation of the potential of using the thermoelectric effect for transformer oil condition testing towards high voltage insulator oil condition detection. This study has found that the used oil sample with various percentages of water content produced a different Seebeck coefficient which shows the potential of using the thermoelectric effect as a simple, cheap, and versatile method to test industrial oil insulator conditions. The results of the Seebeck coefficient for each condition are 0.0003 mV/K (original), 0.0107 mV/K (4 % of water added), and 0.0131 mV/K (40 % of water added), respectively. The industrial oil shows different Seebeck magnitude between oil before and after thermal aging which show a significant decrease of Seebeck magnitude of the industrial oil insulator with an increase of thermal ageing.
- Open Access
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 13  (6) , 6000-6015
Fault localization on power cables using time delay estimation of partial discharge signals
Precise localization of partial discharge (PD) sources on power cables is vital to prevent power line failures that can lead to significant economic losses for electrical suppliers. This study proposes four methods to estimate the time delay of PD signals under electromagnetic interference, including white Gaussian noise (WGN) and discrete sinusoidal interference (DSI), using denoised PD signals with signal-to-noise ratios ranging from 10.6 to -7.02 dB. The maximum peak detection (MPD) and cross-correlation (CC) approaches, as well as two new techniques, interpolation cross-correlation (ICC) and envelope cross-correlation (ECC), are evaluated for their effectiveness in PD source localization. The researchers employ the time difference of arrival (TDoA) algorithm to compute PD location using the double-end PD location algorithm, where the PD location precision serves as an indicator of the accuracy of the time delay estimation methods. The study concludes that CC and ICC are the most suitable methods for estimating the time delay of PD signals in the PD location algorithm, as they exhibit the lowest error rates. These results suggest that CC and ICC can be used effectively for precise PD source localization under electromagnetic interference on power cables.
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 13  (6) , 6000-6015
Open AccessFault localization on power cables using time delay estimation of partial discharge signals
Precise localization of partial discharge (PD) sources on power cables is vital to prevent power line failures that can lead to significant economic losses for electrical suppliers. This study proposes four methods to estimate the time delay of PD signals under electromagnetic interference, including white Gaussian noise (WGN) and discrete sinusoidal interference (DSI), using denoised PD signals with signal-to-noise ratios ranging from 10.6 to -7.02 dB. The maximum peak detection (MPD) and cross-correlation (CC) approaches, as well as two new techniques, interpolation cross-correlation (ICC) and envelope cross-correlation (ECC), are evaluated for their effectiveness in PD source localization. The researchers employ the time difference of arrival (TDoA) algorithm to compute PD location using the double-end PD location algorithm, where the PD location precision serves as an indicator of the accuracy of the time delay estimation methods. The study concludes that CC and ICC are the most suitable methods for estimating the time delay of PD signals in the PD location algorithm, as they exhibit the lowest error rates. These results suggest that CC and ICC can be used effectively for precise PD source localization under electromagnetic interference on power cables.
- Open Access
- 25 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 124911-124919
Capability of AgSiN/SU-8 Layer on Silver-Based SPR for Adulterated Honey Detection
This study introduces the capability of the AgSiN/SU-8 layer on the silver-based SPR structure for water content detection in stingless bee honey. The 30% water content in pure honey was adulterated by water bath procedure until they reached 18% adulterated honey. The experiment was carried out for two different SPR structures, with and without AgSiN/SU-8 layer to examine its potential in protecting the silver metal from eroding and minimize the formation of the silver oxide. The resonance angles of adulterated honey solutions for these two SPR structures denote a similar behavior by shifting to a higher angle from the pure honey solution. It indicates that the AgSiN/SU-8 layer can select and detect the variation percentage of honey water content. After 24 hours, the Cr/Ag/AgSiN/SU-8 structure produces the equivalent resonance angle value with only 5.26% changes in minimum reflectivity. It shows that the AgSiN/SU-8 layer can protect the silver surface from erosion and preserve the SPR characteristic. Besides, the presence of the AgSiN/SU-8 layer on the silver surface is capable of decreasing the oxygen atomic percentage by 21.48%, hence minimizing the growth of silver oxide. This work is a preliminary study of the AgSiN/SU-8 layer to detect water content in stingless bee honey, at the same time can protect the silver surface from erosion and minimize the formation of the silver oxide.
- 25 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 124911-124919
Open AccessCapability of AgSiN/SU-8 Layer on Silver-Based SPR for Adulterated Honey Detection
This study introduces the capability of the AgSiN/SU-8 layer on the silver-based SPR structure for water content detection in stingless bee honey. The 30% water content in pure honey was adulterated by water bath procedure until they reached 18% adulterated honey. The experiment was carried out for two different SPR structures, with and without AgSiN/SU-8 layer to examine its potential in protecting the silver metal from eroding and minimize the formation of the silver oxide. The resonance angles of adulterated honey solutions for these two SPR structures denote a similar behavior by shifting to a higher angle from the pure honey solution. It indicates that the AgSiN/SU-8 layer can select and detect the variation percentage of honey water content. After 24 hours, the Cr/Ag/AgSiN/SU-8 structure produces the equivalent resonance angle value with only 5.26% changes in minimum reflectivity. It shows that the AgSiN/SU-8 layer can protect the silver surface from erosion and preserve the SPR characteristic. Besides, the presence of the AgSiN/SU-8 layer on the silver surface is capable of decreasing the oxygen atomic percentage by 21.48%, hence minimizing the growth of silver oxide. This work is a preliminary study of the AgSiN/SU-8 layer to detect water content in stingless bee honey, at the same time can protect the silver surface from erosion and minimize the formation of the silver oxide.
- 14 May 2023
- Published by Springer Nature
- p. 469-475
Diffusion, Seebeck and Conductivity of Spin Crossover Complexes Towards Thermoelectric Power Generation
- 14 May 2023
- Published by Springer Nature
- p. 469-475
Diffusion, Seebeck and Conductivity of Spin Crossover Complexes Towards Thermoelectric Power Generation