GFGiovanni Faoro

Giovanni Faoro

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Giovanni Faoro has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Improving Trans-Esophageal Echocardiography: A Miniaturized Cooling System

    by Francesca Parrotta, Giovanni Faoro, Selene Tognarelli, Alberto Giannoni, Arianna Menciassi

    Minimally Invasive Surgery (MIS) for cardiac procedures was adopted in the late 90s as a valid alternative to open-heart surgeries, allowing for a minor operative trauma and a faster post-operative recovery. In the context of MIS, the presence of accurate imaging techniques is of paramount importance, as surgeons operate without a direct view of the surgical site. Nowadays, fluoroscopic and ultrasound (US) images, using a Trans-Esophageal probe, are simultaneously employed. The development of real-time three-dimensional Trans-Esophageal Echocardiography has enabled the execution of various trans-catheter procedures. However, recent studies have highlighted the occurrence of esophageal lesions following TEE-guided cardiac interventions. Specifically, blind probe insertion and repeated adjustment for optimal instrument guidance, along with prolonged use-induced heating, appear to be the primary causes of complications. The major reason for using a dual imaging technique is that commercial probes automatically switch off once a temperature threshold of approximately 42.5∘C is reached; for safety reasons related to potential thermal damage to the internal walls of the esophagus. Based on numerical simulations and experimental results, a miniaturized cooling device for TEE probes is proposed, thus reinforcing the reliability of US images in the intraoperative scenario, as they are completely harmless to both patients and doctors. The proposed system consists of a silicone cap incorporating an internal cooling circuit. It does not interfere with the clinical workflow, effectively maintains the probe within a safe temperature range for the entire duration of a surgical procedure, and does not compromise intraoperative image quality.

  • Open Access

    A Multi-Sensorization Approach to Improve Safety in Transesophageal Echocardiography

    by Giovanni Faoro, Izadyar Tamadon, Selene Tognarelli, Arianna Menciassi

    Real-time 3D transesophageal echocardiography (RT-3D TEE) allows 3D visualization of patient heart and catheters without exposing patient and operators to ionizing radiations. Nonetheless, during such procedures esophageal injuries occur due to improper probe manipulation and probe overheating. To tackle these problems, we propose a multisensorization approach to provide information on probe pose and temperature throughout the procedure. Electromagnetic (EM) tracking is fused with inertial sensing thanks to a finite state machine integrating Extended and Incremental Kalman filters. This approach allows for a statistically significant improvement in static tracking with respect to standard EM, as reported by the Mann-Withney test. A novel sensor fault detection based on angular velocities discrepancy allows for robust tracking under different electromagnetic interferences, such as the one provided by ferro-, dia-and paramagnetic materials occupying the interventional room. Fiber optic technology is exploited for temperature estimation, taking advantage of its immunity to EM fields and the possibility of distributed sensing. Performances are compared with a commercial thermistor to guarantee feasibility and a root mean square error of 1.59 C is finally reported. We believe that these results demonstrate how sensing technologies can be integrated in TEE-guided surgical procedures to improve overall outcome and safety.


  • Open Access

    Optical Flow and Acoustic Phase Analysis Comparison in Ultrasound-Based Microrobot Tracking

    by Giovanni Faoro, Veronica Iacovacci, Arianna Menciassi

    Micrometer-sized devices hold the potential to revolutionize medicine by improving diagnostic abilities, increasing therapeutic efficiency and reducing adverse effects. To safely operate microrobots (MRs) inside the human body, accurate localization strategies based on medical imaging should be adopted. Ultrasound (US) imaging has recently gained attention for medical robotics and microrobotics thanks to its noninvasiveness and real-time performances. In this letter we compare US Acoustic Phase Analysis (US-APA), a state-of-the-art Phase tracking method, with US Optical Flow (US-OF), a computer vision Speckle tracking method. To this aim, different MRs dimensions, different locomotion strategies and working environments were considered. In particular, cylindrical magnetic MRs with diameters spanning from 1.20 down to 0.25 mm were fabricated. They were actuated in tissue-mimicking phantoms through a permanent magnet mounted on a robotic arm to reproduce intravascular rolling and in place vibration in tissue. US-OF proved to be comparable to US-APA in localizing vibrating MRs, achieving a tracking error comparable to one body length. It slightly improved localization during rolling, by consistently tracking the MR with errors lower than 0.6 body length. Additionally, US-OF outperformed US-APA in temporal performances, reaching an output rate forty times higher (about 40 Hz in US-OF and about 1 Hz in US-APA). We believe that these results demonstrate the possible effective use of Optical Flow for MRs tracking, with a relevant advantage in terms of portability and intelligibility.


  • Open Access

    An Artificial Intelligence-Aided Robotic Platform for Ultrasound-Guided Transcarotid Revascularization

    by Giovanni Faoro, Sabina Maglio, Stefano Pane, Veronica Iacovacci, Arianna Menciassi

    Transcarotid Artery Revascularization (TCAR) is typically performed by manual catheter insertion and implies radiation exposure for both the patient and the surgeon. Taking advantage from robotics and artificial intelligence (AI), this letter presents a robotic ultrasound (RUS) platform for improving the procedure. To this purpose, ultrasound (US) imaging is considered both in the pre-operative stage for procedure planning and in the intra-operative stage to track a catheter. 3D vascular volumes can be precisely reconstructed from sequences of 2D images exploiting robotic probe manipulation and AI-based image analysis. The method proved a median reconstruction error lower than 1 mm. Pre-operative information are mapped to the intra-operative scenario thanks to a US-based registration routine. The automatic probe alignment on the target vessel demonstrated to be as precise as 0.84°. The reconstructed 3D model can be exploited to automatically generate a catheter trajectory based on user inputs. Such trajectory enabled automatic insertion of a magnetic catheter steered by an external permanent magnet actuated by the RUS platform. Our results demonstrate a catheter tip target reaching error of 3.3 mm. We believe that these results can open the way for the introduction of robotics and AI in TCAR procedures enabling precise and automatic small-scale intravascular devices control.


  • Ultrasound Acoustic Phase Analysis Enables Robotic Visual-Servoing of Magnetic Microrobots

    by Stefano Pane, Giovanni Faoro, Edoardo Sinibaldi, Veronica Iacovacci, Arianna Menciassi

    Microrobots (MRs) have attracted growing interest for their potentialities in diagnosis and noninvasive intervention in hard-to-reach body areas. The safe operation of biomedical MRs requires fine control capabilities, which strongly depend on precise and robust feedback about their position over time. Ultrasound acoustic phase analysis (US-APA) may allow for a reliable feedback strategy for MR imaging and tracking in tissue. In this article, we combine task-specific magnetic actuation and related US-APA motion tracking to achieve closed-loop navigation of a magnetic MR, rolling on the boundary of a lumen in a tissue-mimicking phantom. A C-arm system attached to a robotic platform is used to precisely position the magnetic actuation source and US-APA detection unit within the workspace, thus enabling MR visual-servoing. In the first place, the proposed approach allows to perform supervised localization of the MR without any a-priori knowledge of its position. After localization, a robust real-time tracking enables closed-loop MR teleoperation in the phantom lumina over a travel distance of 80 mm (145 body lengths), both in static and counter flow, thus achieving an average position tracking error of 368 micron (0.67 body lengths). For the first time, our results validate US-APA as a reliable feedback strategy for visual-servoing control of MRs in simulated in-body environment.