Albano Peñalva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Albano Peñalva has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Martin Zalazar
Laboratorio de Prototipado Electrónico y 3D. Facultad de Ingeniería. Universidad Nacional de Entre Ríos / Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - IBB-CONICET/UNER
5 shared publications - Gabriel Guillermo Muñoz
Faculty of Engineering, National University of Entre Ríos, Oro Verde 3100, Argentina
4 shared publications - Juan Ignacio Cerrudo
Faculty of Engineering, National University of Entre Ríos, Oro Verde 3100, Argentina
4 shared publications - Martín Javier Millicovsky
Institute for Research and Development in Bioengineering and Bioinformatics, National University of Entre Ríos—National Scientific and Technical Research Council, Oro Verde 3100, Argentina
4 shared publications - Juan Manuel Reta
Faculty of Engineering, National University of Entre Ríos, Oro Verde 3100, Argentina
3 shared publications - Matías Machtey
Laboratorio de Salud y Bienestar Integral. Facultad de Ingeniería. Universidad Nacional de Entre Rios
2 shared publications
Latest Publications
- Open Access
- 2 October 2026
- Published by Universidad Nacional de Entre Rios in Ciencia, Docencia y Tecnología Suplemento
- Vol. 16 (21)
Desarrollo de un sensor portable para la determinación de la Actividad Biológica en suelos
La salud y el bienestar de los seres humanos están inseparablemente vinculados a la salud de otros componentes del ecosistema, como el suelo, las plantas y los animales. El suelo es un recurso viviente, dinámico y vital para diversos ecosistemas y el mantenimiento de la calidad ambiental. En estos últimos años, la caracterización de los suelos se redujo al análisis físico-químico, y escasamente a indicadores biológicos. Entre éstos últimos, se destaca un método, la hidrólisis de diacetato de fluoresceína, que determina la actividad de diversas enzimas, considerándose un indicador de la actividad microbiológica del suelo. En el presente proyecto, se desarrolló una metodología analítica que permite monitorear la calidad biológica del suelo en campo a partir de simplificar esta metodología de referencia que hasta el presente sólo pueden realizarse en un laboratorio. La misma monitorear el avance de una reacción enzimática de forma continua y asistidas por un celular que registra fotográficamente el interior de una caja oscura; para su posterior análisis digital. Las pruebas de conceptos, demuestran su capacidad para estimar semicuantitativamente la calidad biológica de suelos de forma robusta, portable, rápida, colaborando en la comunicación y entendimiento de los procesos biológicos del suelo y los usos del mismo.
- 2 October 2026
- Published by Universidad Nacional de Entre Rios in Ciencia, Docencia y Tecnología Suplemento
- Vol. 16 (21)
Open AccessDesarrollo de un sensor portable para la determinación de la Actividad Biológica en suelos
La salud y el bienestar de los seres humanos están inseparablemente vinculados a la salud de otros componentes del ecosistema, como el suelo, las plantas y los animales. El suelo es un recurso viviente, dinámico y vital para diversos ecosistemas y el mantenimiento de la calidad ambiental. En estos últimos años, la caracterización de los suelos se redujo al análisis físico-químico, y escasamente a indicadores biológicos. Entre éstos últimos, se destaca un método, la hidrólisis de diacetato de fluoresceína, que determina la actividad de diversas enzimas, considerándose un indicador de la actividad microbiológica del suelo. En el presente proyecto, se desarrolló una metodología analítica que permite monitorear la calidad biológica del suelo en campo a partir de simplificar esta metodología de referencia que hasta el presente sólo pueden realizarse en un laboratorio. La misma monitorear el avance de una reacción enzimática de forma continua y asistidas por un celular que registra fotográficamente el interior de una caja oscura; para su posterior análisis digital. Las pruebas de conceptos, demuestran su capacidad para estimar semicuantitativamente la calidad biológica de suelos de forma robusta, portable, rápida, colaborando en la comunicación y entendimiento de los procesos biológicos del suelo y los usos del mismo.
- Open Access
Development of a Low-Cost, Open-Source Quartz Crystal Microbalance with Dissipation Monitoring for Potential Biomedical Applications
Quartz Crystal Microbalance with Dissipation monitoring (QCM-D) systems are widely used for the real-time analysis of mass changes and viscoelastic properties in biological samples, enabling applications such as biomolecular interaction studies, biosensing, and fluid characterization. However, their accessibility has been limited by high acquisition costs. To address this limitation, a low-cost, open-source QCM-D system was developed. Unlike other affordable, open-hardware alternatives, this system is specifically optimized for potential biomedical applications by integrating active thermal control to preserve the physical properties of the samples and dissipation monitoring to characterize their viscoelastic behavior. A 10 MHz quartz crystal with a sensor module and a control and acquisition unit were integrated. The full system was built at a total cost below USD 500. Performance validation showed a temperature stability of ±0.13 °C, a frequency stability of ±2 Hz in air, and a limit of detection (LOD) of 0.46% polyethylene glycol (PEG), thereby enabling stable, reproducible measurements and the sensitive detection of small mass and interfacial changes in low-concentration samples. These results demonstrate that key QCM-D sensing capabilities can be achieved at a fraction of the cost, providing an accessible and reliable platform for potential biomedical research.
Open AccessDevelopment of a Low-Cost, Open-Source Quartz Crystal Microbalance with Dissipation Monitoring for Potential Biomedical Applications
Quartz Crystal Microbalance with Dissipation monitoring (QCM-D) systems are widely used for the real-time analysis of mass changes and viscoelastic properties in biological samples, enabling applications such as biomolecular interaction studies, biosensing, and fluid characterization. However, their accessibility has been limited by high acquisition costs. To address this limitation, a low-cost, open-source QCM-D system was developed. Unlike other affordable, open-hardware alternatives, this system is specifically optimized for potential biomedical applications by integrating active thermal control to preserve the physical properties of the samples and dissipation monitoring to characterize their viscoelastic behavior. A 10 MHz quartz crystal with a sensor module and a control and acquisition unit were integrated. The full system was built at a total cost below USD 500. Performance validation showed a temperature stability of ±0.13 °C, a frequency stability of ±2 Hz in air, and a limit of detection (LOD) of 0.46% polyethylene glycol (PEG), thereby enabling stable, reproducible measurements and the sensitive detection of small mass and interfacial changes in low-concentration samples. These results demonstrate that key QCM-D sensing capabilities can be achieved at a fraction of the cost, providing an accessible and reliable platform for potential biomedical research.
- Open Access
- 30 September 2025
- Published by MDPI AG in Preprints.org
Development of a Low-Cost, Open-Source Quartz Crystal Microbalance with Dissipation Monitoring for Potential Biomedical Applications
Quartz Crystal Microbalance with Dissipation monitoring (QCM-D) systems are widely used for the real-time analysis of mass changes and viscoelastic properties in biological samples, enabling applications such as biomolecular interaction studies, biosensing, and fluid characterization. However, their accessibility has been limited by high acquisition costs. To address this limitation, the development of a low-cost, open-source QCM-D system tailored for biomedical applications has been carried out. A 10 MHz quartz crystal with a sensor module and a control and acquisition unit were integrated. The full system was built at a total cost below USD 500. Performance validation showed a temperature stability of ±0.13°C, a frequency stability of ±2 Hz in air, and a limit of detection of 0.46% polyethylene glycol (PEG) in batch mode. These results demonstrate that key sensing capabilities can be achieved at a fraction of the cost, making it a viable alternative for certain biomedical applications. Its open-source nature allows full customization and future upgrades, offering a flexible alternative for laboratories seeking affordable yet reliable tools for biophysical analysis.
- 30 September 2025
- Published by MDPI AG in Preprints.org
Open AccessDevelopment of a Low-Cost, Open-Source Quartz Crystal Microbalance with Dissipation Monitoring for Potential Biomedical Applications
Quartz Crystal Microbalance with Dissipation monitoring (QCM-D) systems are widely used for the real-time analysis of mass changes and viscoelastic properties in biological samples, enabling applications such as biomolecular interaction studies, biosensing, and fluid characterization. However, their accessibility has been limited by high acquisition costs. To address this limitation, the development of a low-cost, open-source QCM-D system tailored for biomedical applications has been carried out. A 10 MHz quartz crystal with a sensor module and a control and acquisition unit were integrated. The full system was built at a total cost below USD 500. Performance validation showed a temperature stability of ±0.13°C, a frequency stability of ±2 Hz in air, and a limit of detection of 0.46% polyethylene glycol (PEG) in batch mode. These results demonstrate that key sensing capabilities can be achieved at a fraction of the cost, making it a viable alternative for certain biomedical applications. Its open-source nature allows full customization and future upgrades, offering a flexible alternative for laboratories seeking affordable yet reliable tools for biophysical analysis.
- Open Access
Low-Cost Open-Source Biosensing System Prototype Based on a Love Wave Surface Acoustic Wave Resonator
Love wave surface acoustic wave (LSAW) sensors are crystal resonators known for their high potential for biosensing applications due to their high sensitivity, real-time detection, and compatibility with microfluidic systems. Commercial LSAW devices are costly, and manufacturing them is even more expensive, making accessibility a significant challenge. Additionally, their use requires specialized systems, and with only a few manufacturers dominating the market, most available solutions are proprietary, limiting customization and adaptability for specific research needs. In this work, a low-cost open-source LSAW biosensing system prototype was developed based on a commercially acquired resonator. The development integrates microfluidics through a polydimethylsiloxane (PDMS) chip, low-cost electronics, and both 3D printed ultraviolet (UV) resin and polylactic acid (PLA) parts. The instrument used for measurements was a vector network analyzer (VNA) that features open-source software. The code was customized for this study to enable real-time, label-free biosensing. Experimental validation consisted of evaluating the sensitivity and repeatability of the system, from the setup to its use with different fluids. Results demonstrated that the development is able to advance to more complex applications.
Open AccessLow-Cost Open-Source Biosensing System Prototype Based on a Love Wave Surface Acoustic Wave Resonator
Love wave surface acoustic wave (LSAW) sensors are crystal resonators known for their high potential for biosensing applications due to their high sensitivity, real-time detection, and compatibility with microfluidic systems. Commercial LSAW devices are costly, and manufacturing them is even more expensive, making accessibility a significant challenge. Additionally, their use requires specialized systems, and with only a few manufacturers dominating the market, most available solutions are proprietary, limiting customization and adaptability for specific research needs. In this work, a low-cost open-source LSAW biosensing system prototype was developed based on a commercially acquired resonator. The development integrates microfluidics through a polydimethylsiloxane (PDMS) chip, low-cost electronics, and both 3D printed ultraviolet (UV) resin and polylactic acid (PLA) parts. The instrument used for measurements was a vector network analyzer (VNA) that features open-source software. The code was customized for this study to enable real-time, label-free biosensing. Experimental validation consisted of evaluating the sensitivity and repeatability of the system, from the setup to its use with different fluids. Results demonstrated that the development is able to advance to more complex applications.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Exploring tear viscosity with quartz crystal microbalance technology
Tear viscosity is a critical property affecting tear distribution and ocular surface stability. While not widely established as a primary diagnostic marker, deviations from normal viscosity can impact ocular health, potentially contributing to conditions such as dry eye syndrome. Despite their importance, traditional viscometers require sample volumes that are not feasible to use with tear volume. This research introduces a novel Quartz Crystal Microbalance (QCM)-based method for tear viscosity measurement, offering a viscometer prototype that operates with minimal sample volumes. Human tear samples, solutions used in artificial eye drops, and various commercial eye drop brands were evaluated. Results show that the QCM method aligns with established viscosity ranges. The average viscosity of healthy human tears was found to be 1.73 ± 0.61 cP, aligning with the typical range of 1–10 cP. Variability in the viscosities of eye drop can be attributed to differences in their chemical compositions. The QCM method offers benefits such as reduced sample consumption and rapid results, enhancing understanding of tear dynamics for ocular health. Further research with larger sample sizes is needed to establish normative viscosity values in healthy individuals and those with dry eye syndrome, which is crucial for validating the device’s clinical efficacy.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Exploring tear viscosity with quartz crystal microbalance technology
Tear viscosity is a critical property affecting tear distribution and ocular surface stability. While not widely established as a primary diagnostic marker, deviations from normal viscosity can impact ocular health, potentially contributing to conditions such as dry eye syndrome. Despite their importance, traditional viscometers require sample volumes that are not feasible to use with tear volume. This research introduces a novel Quartz Crystal Microbalance (QCM)-based method for tear viscosity measurement, offering a viscometer prototype that operates with minimal sample volumes. Human tear samples, solutions used in artificial eye drops, and various commercial eye drop brands were evaluated. Results show that the QCM method aligns with established viscosity ranges. The average viscosity of healthy human tears was found to be 1.73 ± 0.61 cP, aligning with the typical range of 1–10 cP. Variability in the viscosities of eye drop can be attributed to differences in their chemical compositions. The QCM method offers benefits such as reduced sample consumption and rapid results, enhancing understanding of tear dynamics for ocular health. Further research with larger sample sizes is needed to establish normative viscosity values in healthy individuals and those with dry eye syndrome, which is crucial for validating the device’s clinical efficacy.
- Open Access
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Quartz Crystal Microbalance with Dissipation Monitoring for Biomedical Applications: Open Source and Low Cost Prototype with Active Temperature Control
Advances in sensors have revolutionized biomedical engineering, having an extreme affinity for specific analytes and providing an effective, real-time, point-of-care testing to obtain an accurate diagnosis. Quartz Crystal Microbalance (QCM) is a well-established sensor that has been successfully applied in a broad range of applications to monitor and explore various surface interactions, in situ thin-film formations, and layer properties. This technology has gained interest in biomedical applications since novel QCM systems were able to work in liquid media. Quartz crystal microbalance with dissipation monitoring (QCM-D) is an expanded version of QCM that measures changes in damping properties of adsorbed layers and provides information on its viscoelastic nature. In this article, a QCM-D prototype designed for biomedical applications was developed and its validation was done by studying the viscosity of Polyethylene Glycol (PEG). Quantification of physical properties of PEG results important for vast medical applications. The statistics show a bigger dissipation as the fluid becomes more viscous and a very acceptable sensibility of the system when temperature is controlled.
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Open AccessQuartz Crystal Microbalance with Dissipation Monitoring for Biomedical Applications: Open Source and Low Cost Prototype with Active Temperature Control
Advances in sensors have revolutionized biomedical engineering, having an extreme affinity for specific analytes and providing an effective, real-time, point-of-care testing to obtain an accurate diagnosis. Quartz Crystal Microbalance (QCM) is a well-established sensor that has been successfully applied in a broad range of applications to monitor and explore various surface interactions, in situ thin-film formations, and layer properties. This technology has gained interest in biomedical applications since novel QCM systems were able to work in liquid media. Quartz crystal microbalance with dissipation monitoring (QCM-D) is an expanded version of QCM that measures changes in damping properties of adsorbed layers and provides information on its viscoelastic nature. In this article, a QCM-D prototype designed for biomedical applications was developed and its validation was done by studying the viscosity of Polyethylene Glycol (PEG). Quantification of physical properties of PEG results important for vast medical applications. The statistics show a bigger dissipation as the fluid becomes more viscous and a very acceptable sensibility of the system when temperature is controlled.