Xue Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xue Wang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Hong-Juan Li
Sleep Medicine Center, Beijing HuiLongGuan Hospital, Peking University HuiLongGuan Clinical Medical School, Beijing, People’s Republic of China
1 shared publication- Jingxu Chen
Beijing Huilongguan Hospital, Capital Medical University
1 shared publication Lei-Lei Wang
Sleep Medicine Center, Beijing HuiLongGuan Hospital, Peking University HuiLongGuan Clinical Medical School, Beijing, People’s Republic of China
1 shared publicationLijuan Yang
The National Clinical Research Center for Mental Disorders & Beijing Key Laboratory of Mental Disorders, Beijing Anding Hospital, Capital Medical University, Beijing, China; Advanced Innovation Center for Human Brain Protection, Capital Medical University, Beijing, China
1 shared publication- Lina Jia
Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing, China
1 shared publication Meng Qi
Sleep Medicine Center, Beijing HuiLongGuan Hospital, Peking University HuiLongGuan Clinical Medical School, Beijing, People’s Republic of China
1 shared publication
Latest Publications
- Open Access
- 1 May 2023
- Published by Taylor & Francis in Nature and Science of Sleep
- Vol. ume 15, 353-362
Measuring Sleep Stages and Screening for Obstructive Sleep Apnea with a Wearable Multi-Sensor System in Comparison to Polysomnography
Objective: To assess the performance of a wearable multi-sensor system (SensEcho) in comparison to polysomnography (PSG) in measuring sleep stages and searching for obstructive sleep apnea (OSA). Methods: Participants underwent overnight simultaneous monitoring using SensEcho and PSG in a sleep laboratory. SensEcho analyzed the recordings spontaneously, and PSG was assessed as per standard guidelines. The degree of snoring was evaluated according to the guidelines for the diagnosis and treatment of OSA hypopnea syndrome (2011 revision). The Epworth Sleepiness Scale (ESS) was used to assess general daytime sleepiness. Results: This study included 103 Han Chinese, 91 of whom (age 39.02 ± 13.84 years, body mass index 27.28 ± 5.12 kg/m2, 61.54% male) completed the assessments. The measures of total sleep time (P = 0.198); total wake time (P = 0.182); shallow sleep (P = 0.297), deep sleep (P = 0.422), rapid eye movement sleep (P = 0.570), and awake (P = 0.336) proportions were similar between SensEcho and PSG. Using an apnea-hypopnea index (AHI) cutoff of ≥ 5 events/h, the SensEcho had 82.69% sensitivity and 89.74% specificity. Almost the same results were obtained at an AHI threshold of ≥ 15 events/h. Although the specificity increased to 94.67%, it decreased to 43.75% at an AHI cutoff of ≥ 30 events/h. Conclusion: This study demonstrated that SensEcho can be used to evaluate sleep status and screen for OSA. Nevertheless, improving the accuracy of its assessment of severe OSA and further testing its effectiveness in community and home environments is necessary.
- 1 May 2023
- Published by Taylor & Francis in Nature and Science of Sleep
- Vol. ume 15, 353-362
Open AccessMeasuring Sleep Stages and Screening for Obstructive Sleep Apnea with a Wearable Multi-Sensor System in Comparison to Polysomnography
Objective: To assess the performance of a wearable multi-sensor system (SensEcho) in comparison to polysomnography (PSG) in measuring sleep stages and searching for obstructive sleep apnea (OSA). Methods: Participants underwent overnight simultaneous monitoring using SensEcho and PSG in a sleep laboratory. SensEcho analyzed the recordings spontaneously, and PSG was assessed as per standard guidelines. The degree of snoring was evaluated according to the guidelines for the diagnosis and treatment of OSA hypopnea syndrome (2011 revision). The Epworth Sleepiness Scale (ESS) was used to assess general daytime sleepiness. Results: This study included 103 Han Chinese, 91 of whom (age 39.02 ± 13.84 years, body mass index 27.28 ± 5.12 kg/m2, 61.54% male) completed the assessments. The measures of total sleep time (P = 0.198); total wake time (P = 0.182); shallow sleep (P = 0.297), deep sleep (P = 0.422), rapid eye movement sleep (P = 0.570), and awake (P = 0.336) proportions were similar between SensEcho and PSG. Using an apnea-hypopnea index (AHI) cutoff of ≥ 5 events/h, the SensEcho had 82.69% sensitivity and 89.74% specificity. Almost the same results were obtained at an AHI threshold of ≥ 15 events/h. Although the specificity increased to 94.67%, it decreased to 43.75% at an AHI cutoff of ≥ 30 events/h. Conclusion: This study demonstrated that SensEcho can be used to evaluate sleep status and screen for OSA. Nevertheless, improving the accuracy of its assessment of severe OSA and further testing its effectiveness in community and home environments is necessary.
- 5 February 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 143, 105287
Scale-free dynamics of microstate sequence in negative schizophrenia and depressive disorder
- 5 February 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 143, 105287
Scale-free dynamics of microstate sequence in negative schizophrenia and depressive disorder