David Grundmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Grundmann has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
- Moritz Seiffert
Department of Cardiology and Angiology (Medical Clinic II), University Hospital Bergmannsheil, Ruhr University Bochum , Bürkle-de-la-Camp-Platz 1, Bochum 44789
6 shared publications Niklas Schofer
Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
5 shared publicationsHermann Reichenspurner
Department of Cardiovascular Surgery (H.R., A.S.), University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Germany
4 shared publicationsLenard Conradi
Department of Cardiovascular Surgery, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Department of Cardiac Surgery, University Hospital Cologne, Köln, Germany
4 shared publicationsDirk Westermann
Department of Cardiology and Angiology, University Heart Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany
3 shared publicationsLara Waldschmidt
Department of Cardiology, University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
3 shared publications
Latest Publications
- 1 August 2025
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 18 (8) , e014771
Procedural and Clinical Outcomes According to Ultrasound-Guided Access in TAVI: A Propensity-Matched Comparative Subanalysis From the PULSE Registry
BACKGROUND: Access-related vascular and bleeding complications during transcatheter aortic valve implantation (TAVI) are associated with significant morbidity and mortality. Ultrasound-guided (USG) puncture may reduce the incidence of these adverse events, particularly in large-bore arterial access. However, large-scale data on this approach are limited, and it has not yet been fully implemented into standard clinical practice. We compared access-related vascular and bleeding complications in USG versus fluoroscopy-guided access from a large multicenter TAVI registry. METHODS: The PULSE registry (Plug- or Suture-Based Vascular Closure After TAVI) retrospectively evaluated data of 9295 patients who underwent transfemoral TAVI at 10 high-volume German heart centers (2016–2021). USG and fluoroscopy-guided access were performed in 1992 (21.4%) and 7303 (78.6%) patients, respectively. Propensity score matching (1:1) yielded 895 matched pairs. The primary end point, a composite of minor and major vascular complications or bleeding type II-IV, was assessed according to Valve Academic Research Consortium definitions. RESULTS: Patients in the USG and fluoroscopy-guided groups (median age, 81.9 [78.3–85.0] years; 47.8% female patients) showed well-balanced baseline characteristics. The overall risk profile was comparable (median EuroSCORE II: 3.2 versus 3.5; SD, 0.007 [−0.086 to 0.099]). The composite primary end point occurred less frequently in the USG group (11.7% versus 16.0%; odds ratio, 0.7; P =0.01), driven by lower rates of procedural bleeding (5.4% versus 9.2%; odds ratio, 0.56; P =0.002) and with lower rates of endovascular treatment (0.7% versus 2.5%; P =0.005). CONCLUSIONS: In patients with transfemoral TAVI, USG access demonstrated lower rates of access-related vascular complications and type II-IV bleeding compared with fluoroscopy-guided access. Implementing USG puncture as the standard of care may improve access-related outcomes after TAVI.
- 1 August 2025
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 18 (8) , e014771
Procedural and Clinical Outcomes According to Ultrasound-Guided Access in TAVI: A Propensity-Matched Comparative Subanalysis From the PULSE Registry
BACKGROUND: Access-related vascular and bleeding complications during transcatheter aortic valve implantation (TAVI) are associated with significant morbidity and mortality. Ultrasound-guided (USG) puncture may reduce the incidence of these adverse events, particularly in large-bore arterial access. However, large-scale data on this approach are limited, and it has not yet been fully implemented into standard clinical practice. We compared access-related vascular and bleeding complications in USG versus fluoroscopy-guided access from a large multicenter TAVI registry. METHODS: The PULSE registry (Plug- or Suture-Based Vascular Closure After TAVI) retrospectively evaluated data of 9295 patients who underwent transfemoral TAVI at 10 high-volume German heart centers (2016–2021). USG and fluoroscopy-guided access were performed in 1992 (21.4%) and 7303 (78.6%) patients, respectively. Propensity score matching (1:1) yielded 895 matched pairs. The primary end point, a composite of minor and major vascular complications or bleeding type II-IV, was assessed according to Valve Academic Research Consortium definitions. RESULTS: Patients in the USG and fluoroscopy-guided groups (median age, 81.9 [78.3–85.0] years; 47.8% female patients) showed well-balanced baseline characteristics. The overall risk profile was comparable (median EuroSCORE II: 3.2 versus 3.5; SD, 0.007 [−0.086 to 0.099]). The composite primary end point occurred less frequently in the USG group (11.7% versus 16.0%; odds ratio, 0.7; P =0.01), driven by lower rates of procedural bleeding (5.4% versus 9.2%; odds ratio, 0.56; P =0.002) and with lower rates of endovascular treatment (0.7% versus 2.5%; P =0.005). CONCLUSIONS: In patients with transfemoral TAVI, USG access demonstrated lower rates of access-related vascular complications and type II-IV bleeding compared with fluoroscopy-guided access. Implementing USG puncture as the standard of care may improve access-related outcomes after TAVI.
- Open Access
- 24 December 2024
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 17 (24) , 2923-2932
Femoral or Radial Secondary Access in TAVR
- 24 December 2024
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 17 (24) , 2923-2932
Open AccessFemoral or Radial Secondary Access in TAVR
- Open Access
- 4 March 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (5) , 1480
Intravascular Lithotripsy-Assisted Transfemoral Transcatheter Aortic Valve Implantation in Patients with Severe Iliofemoral Calcifications: Expanding Transfemoral Indications
(1) Background: Transfemoral transcatheter aortic valve implantation (TAVI) has become the standard treatment for most patients with severe symptomatic aortic stenosis. Intravascular lithotripsy may facilitate transfemoral TAVI (IVL-TAVI) even in patients with severely calcified iliofemoral disease. We assessed technical aspects and clinical outcomes of this novel approach compared to alternative transaxillary access (TAX-TAVI). (2) Methods: IVL-TAVI was performed for severe iliofemoral calcifications precluding standard transfemoral access in 30 patients from 2019 to 2022 at a single academic heart center. IVL was performed as part of the TAVI procedure in all cases. Results were compared to a control group of 44 TAX-TAVI procedures performed for the same indication from 2016 to 2021. The safety outcome was a composite of all-cause death, stroke, access-related bleeding ≥ type 2 within 24 h and major vascular access site complications at 30 days. The efficacy outcome was defined as a technical success according to VARC-3. (3) Results: Median age was 78.2 [74.3, 82.6] years, 45.9% were female and mean STS-PROM was 3.6% [2.3, 6.0]. Iliofemoral calcifications were more severe in the IVL-TAVI vs. TAX-TAVI groups (lesion length: 63.0 mm [48.6, 80.3] vs. 48.5 mm [33.1, 68.8]; p = 0.043, severe calcification at target lesion: 90.0% vs. 68.2%; p = 0.047, and median arc calcification 360.0° [297.5, 360.0] vs. 360.0° [180.0, 360.0]; p = 0.033). Technical success was achieved in 93.3% vs. 81.8% (p = 0.187) in IVL- and TAX-TAVI and the safety outcome occurred in 10.0% vs. 31.8% in IVL- and TAX-TAVI (p = 0.047), respectively. (4) Conclusions: IVL-assisted transfemoral TAVI was feasible and safe with favorable outcomes compared to TAX-TAVI. IVL may further expand the number of patients eligible for transfemoral TAVI and may help overcome limitations of an alternative access.
- 4 March 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (5) , 1480
Open AccessIntravascular Lithotripsy-Assisted Transfemoral Transcatheter Aortic Valve Implantation in Patients with Severe Iliofemoral Calcifications: Expanding Transfemoral Indications
(1) Background: Transfemoral transcatheter aortic valve implantation (TAVI) has become the standard treatment for most patients with severe symptomatic aortic stenosis. Intravascular lithotripsy may facilitate transfemoral TAVI (IVL-TAVI) even in patients with severely calcified iliofemoral disease. We assessed technical aspects and clinical outcomes of this novel approach compared to alternative transaxillary access (TAX-TAVI). (2) Methods: IVL-TAVI was performed for severe iliofemoral calcifications precluding standard transfemoral access in 30 patients from 2019 to 2022 at a single academic heart center. IVL was performed as part of the TAVI procedure in all cases. Results were compared to a control group of 44 TAX-TAVI procedures performed for the same indication from 2016 to 2021. The safety outcome was a composite of all-cause death, stroke, access-related bleeding ≥ type 2 within 24 h and major vascular access site complications at 30 days. The efficacy outcome was defined as a technical success according to VARC-3. (3) Results: Median age was 78.2 [74.3, 82.6] years, 45.9% were female and mean STS-PROM was 3.6% [2.3, 6.0]. Iliofemoral calcifications were more severe in the IVL-TAVI vs. TAX-TAVI groups (lesion length: 63.0 mm [48.6, 80.3] vs. 48.5 mm [33.1, 68.8]; p = 0.043, severe calcification at target lesion: 90.0% vs. 68.2%; p = 0.047, and median arc calcification 360.0° [297.5, 360.0] vs. 360.0° [180.0, 360.0]; p = 0.033). Technical success was achieved in 93.3% vs. 81.8% (p = 0.187) in IVL- and TAX-TAVI and the safety outcome occurred in 10.0% vs. 31.8% in IVL- and TAX-TAVI (p = 0.047), respectively. (4) Conclusions: IVL-assisted transfemoral TAVI was feasible and safe with favorable outcomes compared to TAX-TAVI. IVL may further expand the number of patients eligible for transfemoral TAVI and may help overcome limitations of an alternative access.
- Open Access
- 22 June 2023
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 113 (1) , 192
Response
- 22 June 2023
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 113 (1) , 192
Open AccessResponse
- Open Access
- 19 January 2023
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 112 (5) , 667-676
Prognostic impact and diagnostic value of invasively derived hemodynamic measures in patients with severe aortic stenosis undergoing TAVI
Background: Ejection time (ET), acceleration time (AT) and time between left ventricular and aortic systolic pressure peaks (T-LVAo) might be of diagnostic and prognostic use in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). Aim: We aimed to assess the diagnostic value and prognostic impact of invasively measured ET, AT, and T-LVAo in patients undergoing TAVI. Methods: A total of 1274 patients received invasive measurement of ET, AT and T-LVAo prior to TAVI. Anatomic AS severity was assessed by CT-derived aortic valve calcification density (AVCd). Impact on all-cause mortality was retrospectively analyzed. Results: In multivariable linear regression, T-LVAo showed the strongest correlation with AVCd. No prognostic impact of T-LVAo was found according to uni- and multivariable analyses. In contrast, using an individual C-statistic derived cutoff (CD), patients with ET or AT ≥ CD showed lower mortality rates compared to patients with ET or AT < CD (1-year mortality: ET ≥ vs. < CD: 15.01vs. 33.1%, AT ≥ vs < CD 16.3 vs. 26.5%, p < 0.001). Moreover, multivariable analysis identified ET ≥ CD (HR 0.61 [95% CI 0.43–0.87; p < 0.007]) to be associated with beneficial outcome after TAVI, independent from clinical risk factors and echocardiography-derived parameters. Conclusion: Among the studied hemodynamic parameters T-LVAo provides the highest diagnostic value, whereas ET is an outcome predictor beyond clinical risk factors and echocardiographic parameters in AS patients following TAVI. These parameters could be of considerable use in diagnostic evaluation and risk assessment of patients scheduled for TAVI. Graphical T-LVAo (yellow): defined as time between left ventricular and aortic systolic pressure peaks. ET (green): Ejection Time defined as time from the start to flow end. AT (orange): Acceleration time defined as time from the start to the peak flow. AOP: aortic pressure, AVC: aortic valve calcification, CI: confidence interval, HGAS: high-gradient aortic stenosis, LGAS: low-gradient aortic stenosis, LVP: left ventricular pressure, SD: standard deviation.
- 19 January 2023
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 112 (5) , 667-676
Open AccessPrognostic impact and diagnostic value of invasively derived hemodynamic measures in patients with severe aortic stenosis undergoing TAVI
Background: Ejection time (ET), acceleration time (AT) and time between left ventricular and aortic systolic pressure peaks (T-LVAo) might be of diagnostic and prognostic use in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). Aim: We aimed to assess the diagnostic value and prognostic impact of invasively measured ET, AT, and T-LVAo in patients undergoing TAVI. Methods: A total of 1274 patients received invasive measurement of ET, AT and T-LVAo prior to TAVI. Anatomic AS severity was assessed by CT-derived aortic valve calcification density (AVCd). Impact on all-cause mortality was retrospectively analyzed. Results: In multivariable linear regression, T-LVAo showed the strongest correlation with AVCd. No prognostic impact of T-LVAo was found according to uni- and multivariable analyses. In contrast, using an individual C-statistic derived cutoff (CD), patients with ET or AT ≥ CD showed lower mortality rates compared to patients with ET or AT < CD (1-year mortality: ET ≥ vs. < CD: 15.01vs. 33.1%, AT ≥ vs < CD 16.3 vs. 26.5%, p < 0.001). Moreover, multivariable analysis identified ET ≥ CD (HR 0.61 [95% CI 0.43–0.87; p < 0.007]) to be associated with beneficial outcome after TAVI, independent from clinical risk factors and echocardiography-derived parameters. Conclusion: Among the studied hemodynamic parameters T-LVAo provides the highest diagnostic value, whereas ET is an outcome predictor beyond clinical risk factors and echocardiographic parameters in AS patients following TAVI. These parameters could be of considerable use in diagnostic evaluation and risk assessment of patients scheduled for TAVI. Graphical T-LVAo (yellow): defined as time between left ventricular and aortic systolic pressure peaks. ET (green): Ejection Time defined as time from the start to flow end. AT (orange): Acceleration time defined as time from the start to the peak flow. AOP: aortic pressure, AVC: aortic valve calcification, CI: confidence interval, HGAS: high-gradient aortic stenosis, LGAS: low-gradient aortic stenosis, LVP: left ventricular pressure, SD: standard deviation.
- 17 March 2022
- Published by Elsevier in The American Journal of Cardiology
- Vol. 171, 115-121
Contemporary Outcome Trends in Transcatheter Aortic Valve-in-Valve Implantation Versus Redo Aortic Valve Replacement
- 17 March 2022
- Published by Elsevier in The American Journal of Cardiology
- Vol. 171, 115-121
Contemporary Outcome Trends in Transcatheter Aortic Valve-in-Valve Implantation Versus Redo Aortic Valve Replacement
- 8 February 2022
- Published by Elsevier in American Heart Journal
- Vol. 247, 112-122
Stroke events after transcatheter aortic valve implantation: Temporal relationships and affected brain regions
- 8 February 2022
- Published by Elsevier in American Heart Journal
- Vol. 247, 112-122
Stroke events after transcatheter aortic valve implantation: Temporal relationships and affected brain regions
- 1 January 2021
- Published by Georg Thieme Verlag KG
- Vol. 69 (S 01) , DGTHG-eP96
Comparison of Two Contemporary Balloon-Expandable Transcatheter Heart Valves: Sapien 3 versus Sapien 3 Ultra
Objectives: Transcatheter aortic valve implantation (TAVI) is an established therapy for severe aortic valve stenosis in patients at high or intermediate risk. Balloon-expandable (BE) transcatheter heart valves (THV) from the Sapien family (Edwards Lifesciences Inc., Irvine, California, USA) are among the most frequently used TAVI systems. We herein aimed to compare outcomes of patients receiving with Sapien 3 (S3) with S3 Ultra (S3U) at our center. Methods: Between 05/2018 and 05/2020, a total of 100 consecutive patients (41% female, 80.2 ± 6.7 years, logEuroSCORE I 15.7 ± 14.2%) received transfemoral TAVI using the S3 device and 100 consecutive patients (32% female, 79.8 ± 6.4 years, logEuroSCORE I 11.7 ± 10.3%) received S3U THV. Data were retrospectively analyzed according to updated Valve Academic Research Consortium (VARC-2) definitions. Result: Patients receiving a S3 THV were at significantly increased preoperative risk compared with the S3U cohort (logEuroSCORE I: S3 15.7 ± 14.2 vs. S3U 11.7 ± 10.3, p = 0.02). Device success (98 vs. 97%, p = 1.0), early safety (87 vs. 92%, p = 0.36), 30-day mortality (4 vs. 2%, p = 0.36), periprocedural stroke (2 vs. 2%, p = 1.0), myocardial Infarction (1 vs. 0%, p = 1.0), access site complications (5 vs. 3%, p = 0.72), acute kidney injury (6 vs. 1%, p = 0.12), postprocedural permanent pacemaker implantation (10 vs. 11%, p = 1.0) and postprocedural transvalvular pressure gradients (peak gradient: 20.9 ± 10.7 vs. 19.6 ± 8.3, p = 0.37; mean gradient: 10.5 ± 5.6 vs. 10.1 ± 4.7, p = 0.59) showed no significant differences between the two THV cohorts. Although rates of paravalvular leakage (PVL) ≥ moderate were not different at 30-day follow-up (1 vs. 0%, p = 1.0), incidence of mild PVL was observed more frequently in S3 patients (36 vs. 22%, p = 0.04). Conclusion: Both herein investigated THV demonstrated adequate 30-day outcomes and hemodynamic results. Comparison of the two systems revealed similar clinical results, despite a significantly higher preoperative risk profile in the S3 cohort. Incidence of mild PVL was significantly lower in the S3U cohort, which may be of particular importance for future indication of TAVI in younger patients with lower risk profiles. These results have to be confirmed in larger patient cohorts. Publication Date: 19 February 2021 (online) © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 1 January 2021
- Published by Georg Thieme Verlag KG
- Vol. 69 (S 01) , DGTHG-eP96
Comparison of Two Contemporary Balloon-Expandable Transcatheter Heart Valves: Sapien 3 versus Sapien 3 Ultra
Objectives: Transcatheter aortic valve implantation (TAVI) is an established therapy for severe aortic valve stenosis in patients at high or intermediate risk. Balloon-expandable (BE) transcatheter heart valves (THV) from the Sapien family (Edwards Lifesciences Inc., Irvine, California, USA) are among the most frequently used TAVI systems. We herein aimed to compare outcomes of patients receiving with Sapien 3 (S3) with S3 Ultra (S3U) at our center. Methods: Between 05/2018 and 05/2020, a total of 100 consecutive patients (41% female, 80.2 ± 6.7 years, logEuroSCORE I 15.7 ± 14.2%) received transfemoral TAVI using the S3 device and 100 consecutive patients (32% female, 79.8 ± 6.4 years, logEuroSCORE I 11.7 ± 10.3%) received S3U THV. Data were retrospectively analyzed according to updated Valve Academic Research Consortium (VARC-2) definitions. Result: Patients receiving a S3 THV were at significantly increased preoperative risk compared with the S3U cohort (logEuroSCORE I: S3 15.7 ± 14.2 vs. S3U 11.7 ± 10.3, p = 0.02). Device success (98 vs. 97%, p = 1.0), early safety (87 vs. 92%, p = 0.36), 30-day mortality (4 vs. 2%, p = 0.36), periprocedural stroke (2 vs. 2%, p = 1.0), myocardial Infarction (1 vs. 0%, p = 1.0), access site complications (5 vs. 3%, p = 0.72), acute kidney injury (6 vs. 1%, p = 0.12), postprocedural permanent pacemaker implantation (10 vs. 11%, p = 1.0) and postprocedural transvalvular pressure gradients (peak gradient: 20.9 ± 10.7 vs. 19.6 ± 8.3, p = 0.37; mean gradient: 10.5 ± 5.6 vs. 10.1 ± 4.7, p = 0.59) showed no significant differences between the two THV cohorts. Although rates of paravalvular leakage (PVL) ≥ moderate were not different at 30-day follow-up (1 vs. 0%, p = 1.0), incidence of mild PVL was observed more frequently in S3 patients (36 vs. 22%, p = 0.04). Conclusion: Both herein investigated THV demonstrated adequate 30-day outcomes and hemodynamic results. Comparison of the two systems revealed similar clinical results, despite a significantly higher preoperative risk profile in the S3 cohort. Incidence of mild PVL was significantly lower in the S3U cohort, which may be of particular importance for future indication of TAVI in younger patients with lower risk profiles. These results have to be confirmed in larger patient cohorts. Publication Date: 19 February 2021 (online) © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 27 February 2020
- Published by Elsevier in International Journal of Cardiology
- Vol. 312, 42-47
Long-term follow-up and predictors of target lesion failure after implantation of everolimus-eluting bioresorbable scaffolds in real-world practice
- 27 February 2020
- Published by Elsevier in International Journal of Cardiology
- Vol. 312, 42-47
Long-term follow-up and predictors of target lesion failure after implantation of everolimus-eluting bioresorbable scaffolds in real-world practice