Koji Kosaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Koji Kosaka has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Yoshifumi Nakazawa
2 shared publications- Detlef R. U. Knappe
Department of Civil, Construction, and Environmental Engineering North Carolina State University Raleigh North Carolina USA
1 shared publication - Klon D. C. Hinneh
Kyoto University Sakyo
1 shared publication M. Akiba
National Institute of Public Health, 2-3-6 Minami, Wako, Saitama 351-0197, Japan
1 shared publicationM. Asami
Department of Environmental Health, National Institute of Public Health, 2-3-6 Minami, Wako, Saitama 351-0197, Japan
1 shared publicationMari Asami
Department of Environmental Health, National Institute of Public Health, 2-3-6 Minami, Wako, Saitama 351-0197, Japan
1 shared publication
Latest Publications
- Open Access
- 9 October 2026
- Published by Elsevier in Water Research
- Vol. 309
Release of per- and polyfluoroalkyl substances (PFAS) from spent granular activated carbon: Importance of the long-term releasable PFAS pool and suppression by calcium ions
- 9 October 2026
- Published by Elsevier in Water Research
- Vol. 309
Open AccessRelease of per- and polyfluoroalkyl substances (PFAS) from spent granular activated carbon: Importance of the long-term releasable PFAS pool and suppression by calcium ions
- Open Access
- 30 April 2026
- Published by IWA Publishing in Water Practice & Technology
- Vol. 21 (6) , 2144-2153
Monitoring of organic matter during water treatment processes using a continuous excitation emission matrix monitor
Using a continuous excitation-emission matrix (EEM) monitor, EEM data were collected at each treatment process, and the relationship between component changes identified by PARAFAC analysis and water quality data was evaluated. At water treatment plants using surface water as raw water, the raw water quality constantly fluctuates. To supply tap water of stable quality, it is important to understand and respond to water quality fluctuations in the water purification and treatment process. The dissolved organic matter (DOM) in water is composed of various types of compounds, and thus, the treatability of DOM is dependent on its composition. In this study, the behavior of DOM during the drinking water treatment processes was analyzed using three-dimensional fluorescence spectroscopy (excitation-emission matrix). The results showed that treated water at Plant A was composed of three types of organic matter, and among them, the seasonal variation of protein-like substances was large. Furthermore, the results showed that the type of easily removed organic matter is dependent on the water treatment.
- 30 April 2026
- Published by IWA Publishing in Water Practice & Technology
- Vol. 21 (6) , 2144-2153
Open AccessMonitoring of organic matter during water treatment processes using a continuous excitation emission matrix monitor
Using a continuous excitation-emission matrix (EEM) monitor, EEM data were collected at each treatment process, and the relationship between component changes identified by PARAFAC analysis and water quality data was evaluated. At water treatment plants using surface water as raw water, the raw water quality constantly fluctuates. To supply tap water of stable quality, it is important to understand and respond to water quality fluctuations in the water purification and treatment process. The dissolved organic matter (DOM) in water is composed of various types of compounds, and thus, the treatability of DOM is dependent on its composition. In this study, the behavior of DOM during the drinking water treatment processes was analyzed using three-dimensional fluorescence spectroscopy (excitation-emission matrix). The results showed that treated water at Plant A was composed of three types of organic matter, and among them, the seasonal variation of protein-like substances was large. Furthermore, the results showed that the type of easily removed organic matter is dependent on the water treatment.
- Open Access
- 28 October 2025
- Published by IWA Publishing in Water Supply
- Vol. 25 (11) , 1530-1538
Investigating the sources of perfluorobutanesulfonic acid in a watershed of the Chugoku region in Japan
Perfluorobutanesulfonic acid (PFBS), one of the per- and polyfluorinated alkyl substances (PFAS), was found in higher concentrations than other PFAS in drinking water at a drinking water treatment plant (DWTP) located in the Chugoku region, western Japan. Raw water of the DWTP is the underflow water of the Takaya River, part of the Ashida River system. In this study, surveys of 18 PFAS were conducted in the surface waters of the Ashida River system from June 2022 to June 2023 to investigate the sources of PFBS in DWTP water. PFBS was found in all samples at concentrations of 1.4–9,200 ng/L, and was widely present in the Ashida River system. Two PFBS sources were found in the tributaries of the Takaya River: the Shimizu and Miyama Rivers, involving a creek. The PFBS concentrations near the PFBS sources in the two rivers were 6,700 and 9,200 ng/L, respectively. Among the target PFAS, molar percentages of PFBS in the two PFBS sources were very high (99.6 and 79%, respectively). The estimations of PFBS loads indicated that the PFBS sources in the Shimizu and Miyama Rivers were the major PFBS sources of the DWTP, and the contribution of the Shimizu River was higher.
- 28 October 2025
- Published by IWA Publishing in Water Supply
- Vol. 25 (11) , 1530-1538
Open AccessInvestigating the sources of perfluorobutanesulfonic acid in a watershed of the Chugoku region in Japan
Perfluorobutanesulfonic acid (PFBS), one of the per- and polyfluorinated alkyl substances (PFAS), was found in higher concentrations than other PFAS in drinking water at a drinking water treatment plant (DWTP) located in the Chugoku region, western Japan. Raw water of the DWTP is the underflow water of the Takaya River, part of the Ashida River system. In this study, surveys of 18 PFAS were conducted in the surface waters of the Ashida River system from June 2022 to June 2023 to investigate the sources of PFBS in DWTP water. PFBS was found in all samples at concentrations of 1.4–9,200 ng/L, and was widely present in the Ashida River system. Two PFBS sources were found in the tributaries of the Takaya River: the Shimizu and Miyama Rivers, involving a creek. The PFBS concentrations near the PFBS sources in the two rivers were 6,700 and 9,200 ng/L, respectively. Among the target PFAS, molar percentages of PFBS in the two PFBS sources were very high (99.6 and 79%, respectively). The estimations of PFBS loads indicated that the PFBS sources in the Shimizu and Miyama Rivers were the major PFBS sources of the DWTP, and the contribution of the Shimizu River was higher.
- 4 February 2022
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 56 (4) , 2345-2354
Predictable Liquid Chromatography Quadrupole Time-of-Flight Mass Spectrometry Fragmentation of Ozone-Reactive N-Nitrosodimethylamine Precursors Coupled with In Silico Fragmentation and Ion Mobility-Quadrupole Time-of-Flight Facilitates Their Identification in Sewage
This study investigated the liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QTOF/MS) fragmentation of 10 potent model ozone (O3)-reactive N-nitrosodimethylamine (NDMA) precursors bearing (CH3)2N–N or (CH3)2N–(SO2)–N. Fragments (m/z 61.0766, 60.0688 Da loss, and 72.0688 Da loss) were discovered as pertinent diagnostic fragments for precursors bearing (CH3)2N–N, whereas a loss of 108.0119 Da was consistent for precursors bearing (CH3)2N–S(O2)–N. Using the fragments as structural hints on a sewage fraction with a high concentration of O3-reactive precursors, peaks of precursors sharing m/z 61.0766, a 60.0688 Da loss, or both were flagged. Then, using in silico fragmenters and (CH3)2N–N as a substructure filter on online-chemical structure databases, we identified PubChem’s compound identifier (PCCID) 141210417 and 1,1,1′,1′-tetramethyl-4,4′-(methylene-di-p-phenylene)disemicarbazide (TMDS). TMDS was confirmed using an authentic standard, and ion mobility (IM)-QTOF/MS confirmed its rider peak as PCCID 141210417. PCCID 141210417 is an isomer of TMDS, and its environmental occurrence is associated with technical-grade TMDS and industrial effluents. The estimated contribution of TMDS to the total NDMA formation potential of the sewage fraction was 20–24%, which was suggestive of the significance of PCCID 141210417 and other precursors.
- 4 February 2022
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 56 (4) , 2345-2354
Predictable Liquid Chromatography Quadrupole Time-of-Flight Mass Spectrometry Fragmentation of Ozone-Reactive N-Nitrosodimethylamine Precursors Coupled with In Silico Fragmentation and Ion Mobility-Quadrupole Time-of-Flight Facilitates Their Identification in Sewage
This study investigated the liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QTOF/MS) fragmentation of 10 potent model ozone (O3)-reactive N-nitrosodimethylamine (NDMA) precursors bearing (CH3)2N–N or (CH3)2N–(SO2)–N. Fragments (m/z 61.0766, 60.0688 Da loss, and 72.0688 Da loss) were discovered as pertinent diagnostic fragments for precursors bearing (CH3)2N–N, whereas a loss of 108.0119 Da was consistent for precursors bearing (CH3)2N–S(O2)–N. Using the fragments as structural hints on a sewage fraction with a high concentration of O3-reactive precursors, peaks of precursors sharing m/z 61.0766, a 60.0688 Da loss, or both were flagged. Then, using in silico fragmenters and (CH3)2N–N as a substructure filter on online-chemical structure databases, we identified PubChem’s compound identifier (PCCID) 141210417 and 1,1,1′,1′-tetramethyl-4,4′-(methylene-di-p-phenylene)disemicarbazide (TMDS). TMDS was confirmed using an authentic standard, and ion mobility (IM)-QTOF/MS confirmed its rider peak as PCCID 141210417. PCCID 141210417 is an isomer of TMDS, and its environmental occurrence is associated with technical-grade TMDS and industrial effluents. The estimated contribution of TMDS to the total NDMA formation potential of the sewage fraction was 20–24%, which was suggestive of the significance of PCCID 141210417 and other precursors.
- 1 October 2012
- Published by IWA Publishing in Water Supply
- Vol. 12 (6) , 791-798
Elution of bisphenol A and its chlorination by-products from lined pipes in water supply process
Elution of bisphenol A (BPA), chlorinated BPAs (i.e., 3-chlorobisphenol A, sum of 3,5-dichlorobisphenol A and 3,3′-dichlorobisphenol A, 3,3′,5-trichlorobisphenol A, and 3,3′,5,5′-tetrachlorobisphenol A) and 2,4,6-trichlorophenol (TCP) from lined pipes coated with two epoxy resins were investigated in a 24-month continuous test passing tap water. BPA, chlorinated BPAs, and TCP were not detected in the tap water at the outlet of lined pipes in most cases. However, all of these chemicals were detected in the tap water after 16 h of retention. The sums of BPA and chlorinated BPAs in the retained tap water were usually high when the residual chlorine levels were low. The residual chlorine was related to temperature, residual chlorine in the tap water at the inlet of lined pipes, and the elapsed time. From the results of leach tests, it was indicated that no marked changes in BPA concentration over the 24 months of the continuous test. Chlorinated BPAs and TCP were accumulated on the surface of lined pipes during the continuous test.
- 1 October 2012
- Published by IWA Publishing in Water Supply
- Vol. 12 (6) , 791-798
Elution of bisphenol A and its chlorination by-products from lined pipes in water supply process
Elution of bisphenol A (BPA), chlorinated BPAs (i.e., 3-chlorobisphenol A, sum of 3,5-dichlorobisphenol A and 3,3′-dichlorobisphenol A, 3,3′,5-trichlorobisphenol A, and 3,3′,5,5′-tetrachlorobisphenol A) and 2,4,6-trichlorophenol (TCP) from lined pipes coated with two epoxy resins were investigated in a 24-month continuous test passing tap water. BPA, chlorinated BPAs, and TCP were not detected in the tap water at the outlet of lined pipes in most cases. However, all of these chemicals were detected in the tap water after 16 h of retention. The sums of BPA and chlorinated BPAs in the retained tap water were usually high when the residual chlorine levels were low. The residual chlorine was related to temperature, residual chlorine in the tap water at the inlet of lined pipes, and the elapsed time. From the results of leach tests, it was indicated that no marked changes in BPA concentration over the 24 months of the continuous test. Chlorinated BPAs and TCP were accumulated on the surface of lined pipes during the continuous test.