Darren Lui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Darren Lui has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Jason Bernard
Department of Trauma and Orthopaedics, St George’s University Hospitals NHS Foundation Trust, London, United Kingdom
3 shared publications- Bisola Ajayi
Complex Spinal Division, Neurosciences Atkinson Morley Wing, St. George’s Hospital, London, UK
2 shared publications - Jason Bernard
St George’s University Hospitals, NHS Foundation Trust, London SW17 0OT, UK
2 shared publications Timothy Bishop
Department of Orthopaedics, St George′s NHS Foundation Trust, London, UK
2 shared publications- Timothy Bishop
St George’s University Hospitals, NHS Foundation Trust, London SW17 0OT, UK
2 shared publications - Adrian Gardner
The Royal Orthopedic Hospital NHS Foundation Trust, Birmingham, UK
1 shared publication
Latest Publications
- Open Access
- 23 June 2026
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 9 (2) , 46645
IMMEDIATE HEIGHT GAIN DURING SCOLIOSIS BRACE FITTING AS A PREDICTOR OF IN-BRACE SKELETAL CORRECTION: A NON-RADIOGRAPHIC CLINICAL INDICATOR
BACKGROUND: Spinal curvature in adolescent idiopathic scoliosis (AIS) is associated with a reduction in standing height. While height loss due to scoliosis and height gain following surgical correction are well described, little is known about immediate height change during scoliosis brace fitting and its relationship to in-brace skeletal correction. In-brace Cobb angle correction remains a primary indicator of brace effectiveness; however, no radiation-free clinical tool exists to support early assessment during fitting. OBJECTIVE: To investigate whether immediate standing height change during scoliosis brace fitting is associated with in-brace Cobb angle correction. METHODOLOGY: A retrospective audit was conducted on 60 adolescents with idiopathic scoliosis (13 males, 47 females; mean age 12.4 ± 1.7 years; mean standing height 156.6 ± 10.7 cm) treated at The London Orthotic Consultancy in Kingston, UK. Clinical data were collected between January and October 2022. Standing height was measured immediately before and after brace fitting, and Cobb angles were assessed at baseline and in-brace. Correlation and simple linear regression analyses were performed to explore the relationship between height change and in-brace correction. RESULTS: The mean baseline Cobb angle was 38.0 ± 10.7°, correcting to a mean in-brace Cobb angle of 10.3 ± 9.4°, corresponding to a mean absolute Cobb angle correction of 27.8 ± 9.9° and mean percentage correction of 74.3 ± 19.2%. Mean height gain at fitting was 1.24 ± 0.74 cm (range −0.2 to 3.5 cm). Descriptive analyses included the full cohort (n = 60), including participants demonstrating radiographic over-correction (n = 6). Following exclusion of cases demonstrating radiographic over-correction (>100%), a moderate positive association was observed (R = 0.45, p = 0.001). Sex-specific subgroup analysis was not performed due to limited statistical power. CONCLUSION: Immediate height gain during scoliosis brace fitting demonstrates a moderate association with in-brace skeletal correction and may serve as a simple, radiation-free clinical indicator of mechanical brace response. Height measurement should be interpreted as an adjunct to, rather than a replacement for, radiographic assessment. Prospective studies using multivariable predictive models are warranted to further evaluate its clinical utility. Layman's Abstract Scoliosis is a condition in which the spine curves sideways. In children and adolescents, this curvature can make a person appear slightly shorter because the spine is not fully upright. One of the main goals of brace treatment is to straighten the spine as much as possible while the child is still growing. Currently, the main way to check how well a brace is working is by taking an X-ray, but repeated X-rays expose young patients to radiation. This study explored whether a simple measurement, standing height, could provide useful information during a brace fitting appointment without using radiation. We reviewed the clinical records of 60 adolescents with idiopathic scoliosis (13 males and 47 females) who were treated at The London Orthotic Consultancy in Kingston, UK. The average age of the patients was 12.4 years, and their average standing height was 156.6 cm. The data were collected between January and October 2022. During the brace fitting appointment, each patient’s height was measured immediately before and after putting on the brace. X-rays were also taken to measure how much the spinal curve improved while wearing the brace. On average, patients became about 1.24 cm taller when the brace was first fitted, although the change ranged from a decrease of 0.2 cm to an increase of 3.5 cm. The average spinal curve improved from 38° before bracing to 10° while wearing the brace, corresponding to an average absolute correction of 28° and an average percentage correction of 74%. In general, larger increases in height were associated with greater straightening of the spine seen on X-rays. These findings suggest that measuring height during a brace fitting appointment may provide clinicians with a quick, safe, and radiation-free way to gain early insight into how well a brace is working. Although height measurement cannot replace X-rays, it may help clinicians make better decisions during brace fitting and potentially reduce unnecessary radiation exposure for young patients with scoliosis. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/46645/35062 How To Cite: Courtney A, Walmsley S, Bishop T, Bernard J, Darren L, Jones R.K, et al. Immediate height gain during scoliosis brace fitting as a predictor of in-brace skeletal correction: A non-radiographic clinical indicator. Can Prosthet Orthot J. 2026;9(2):3. https://doi.org/10.33137/cpoj.v9i2.46645 Corresponding Author: Anna Courtney, Affiliation: The London Orthotic Consultancy, Kingston upon Thames, United Kingdom.E-Mails: anna.courtney@londonorthotics.co.ukORCID ID: https://orcid.org/0009-0009-0726-1186
- 23 June 2026
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 9 (2) , 46645
Open AccessIMMEDIATE HEIGHT GAIN DURING SCOLIOSIS BRACE FITTING AS A PREDICTOR OF IN-BRACE SKELETAL CORRECTION: A NON-RADIOGRAPHIC CLINICAL INDICATOR
BACKGROUND: Spinal curvature in adolescent idiopathic scoliosis (AIS) is associated with a reduction in standing height. While height loss due to scoliosis and height gain following surgical correction are well described, little is known about immediate height change during scoliosis brace fitting and its relationship to in-brace skeletal correction. In-brace Cobb angle correction remains a primary indicator of brace effectiveness; however, no radiation-free clinical tool exists to support early assessment during fitting. OBJECTIVE: To investigate whether immediate standing height change during scoliosis brace fitting is associated with in-brace Cobb angle correction. METHODOLOGY: A retrospective audit was conducted on 60 adolescents with idiopathic scoliosis (13 males, 47 females; mean age 12.4 ± 1.7 years; mean standing height 156.6 ± 10.7 cm) treated at The London Orthotic Consultancy in Kingston, UK. Clinical data were collected between January and October 2022. Standing height was measured immediately before and after brace fitting, and Cobb angles were assessed at baseline and in-brace. Correlation and simple linear regression analyses were performed to explore the relationship between height change and in-brace correction. RESULTS: The mean baseline Cobb angle was 38.0 ± 10.7°, correcting to a mean in-brace Cobb angle of 10.3 ± 9.4°, corresponding to a mean absolute Cobb angle correction of 27.8 ± 9.9° and mean percentage correction of 74.3 ± 19.2%. Mean height gain at fitting was 1.24 ± 0.74 cm (range −0.2 to 3.5 cm). Descriptive analyses included the full cohort (n = 60), including participants demonstrating radiographic over-correction (n = 6). Following exclusion of cases demonstrating radiographic over-correction (>100%), a moderate positive association was observed (R = 0.45, p = 0.001). Sex-specific subgroup analysis was not performed due to limited statistical power. CONCLUSION: Immediate height gain during scoliosis brace fitting demonstrates a moderate association with in-brace skeletal correction and may serve as a simple, radiation-free clinical indicator of mechanical brace response. Height measurement should be interpreted as an adjunct to, rather than a replacement for, radiographic assessment. Prospective studies using multivariable predictive models are warranted to further evaluate its clinical utility. Layman's Abstract Scoliosis is a condition in which the spine curves sideways. In children and adolescents, this curvature can make a person appear slightly shorter because the spine is not fully upright. One of the main goals of brace treatment is to straighten the spine as much as possible while the child is still growing. Currently, the main way to check how well a brace is working is by taking an X-ray, but repeated X-rays expose young patients to radiation. This study explored whether a simple measurement, standing height, could provide useful information during a brace fitting appointment without using radiation. We reviewed the clinical records of 60 adolescents with idiopathic scoliosis (13 males and 47 females) who were treated at The London Orthotic Consultancy in Kingston, UK. The average age of the patients was 12.4 years, and their average standing height was 156.6 cm. The data were collected between January and October 2022. During the brace fitting appointment, each patient’s height was measured immediately before and after putting on the brace. X-rays were also taken to measure how much the spinal curve improved while wearing the brace. On average, patients became about 1.24 cm taller when the brace was first fitted, although the change ranged from a decrease of 0.2 cm to an increase of 3.5 cm. The average spinal curve improved from 38° before bracing to 10° while wearing the brace, corresponding to an average absolute correction of 28° and an average percentage correction of 74%. In general, larger increases in height were associated with greater straightening of the spine seen on X-rays. These findings suggest that measuring height during a brace fitting appointment may provide clinicians with a quick, safe, and radiation-free way to gain early insight into how well a brace is working. Although height measurement cannot replace X-rays, it may help clinicians make better decisions during brace fitting and potentially reduce unnecessary radiation exposure for young patients with scoliosis. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/46645/35062 How To Cite: Courtney A, Walmsley S, Bishop T, Bernard J, Darren L, Jones R.K, et al. Immediate height gain during scoliosis brace fitting as a predictor of in-brace skeletal correction: A non-radiographic clinical indicator. Can Prosthet Orthot J. 2026;9(2):3. https://doi.org/10.33137/cpoj.v9i2.46645 Corresponding Author: Anna Courtney, Affiliation: The London Orthotic Consultancy, Kingston upon Thames, United Kingdom.E-Mails: anna.courtney@londonorthotics.co.ukORCID ID: https://orcid.org/0009-0009-0726-1186
- Open Access
- 1 January 2026
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2026 (1)
Lumbar Plexopathy and Exploration Following an Oblique Lumbar Interbody Fusion (OLIF) iFactor‐Associated Complication: A Case Report
Background: Oblique lumbar interbody fusion (OLIF) is a minimally invasive surgical technique used for lumbar spine stabilisation, known for reducing the morbidity associated with traditional posterior lumbar fusion techniques. iFactor, a synthetic bone graft composed of P‐15 osteogenic cell‐binding peptide and anorganic bone mineral (ABM), is often used in such procedures for its reported high fusion rates and minimal complications. iFactor reports to only form bone when grafted into bone tissue, and not soft tissue. This case report presents a rare but significant complication requiring reoperation due to extruded iFactor putty. Case Presentation: A 65‐year‐old female smoker with a history of failed conservative management for back and right radicular leg pain underwent an OLIF procedure at the L4/5 intervertebral level. Postoperatively, she was well for the first 2 weeks but suddenly developed left leg and lower back pain. Delayed diagnosis of a rare complication was detected only after postoperative CT scans were analysed 6 months after surgery. Initial imaging suggested exogenous bone growth affecting the lumbar plexus. Management and Outcome: Diagnostic nerve blocks revealed that L3 and L4 roots were affected. Exploratory surgery importantly revealed that de novo bone had not encased the nerve roots but revealed a chalky paste appearance consistent with extruded iFactor putty. Following the surgery, the patient′s symptoms improved considerably, emphasising the importance of accurate diagnosis and multidisciplinary team (MDT) involvement. Conclusion: This is a rare complication following OLIF, allowing extruded artificial graft to encase part of the lumbar plexus. This case supports the manufacturer′s assertion that iFactor does not lead to exogenous bone growth. The surgical exploration revealed a chalk‐like paste that was irritating the nerve plexus and highlights that surgical debridement of this substance under the psoas muscle is possible. This case also highlights that exploration of extruded bone grafts can be considered for patients presenting similarly after spinal fusion surgeries involving bone grafts.
- 1 January 2026
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2026 (1)
Open AccessLumbar Plexopathy and Exploration Following an Oblique Lumbar Interbody Fusion (OLIF) iFactor‐Associated Complication: A Case Report
Background: Oblique lumbar interbody fusion (OLIF) is a minimally invasive surgical technique used for lumbar spine stabilisation, known for reducing the morbidity associated with traditional posterior lumbar fusion techniques. iFactor, a synthetic bone graft composed of P‐15 osteogenic cell‐binding peptide and anorganic bone mineral (ABM), is often used in such procedures for its reported high fusion rates and minimal complications. iFactor reports to only form bone when grafted into bone tissue, and not soft tissue. This case report presents a rare but significant complication requiring reoperation due to extruded iFactor putty. Case Presentation: A 65‐year‐old female smoker with a history of failed conservative management for back and right radicular leg pain underwent an OLIF procedure at the L4/5 intervertebral level. Postoperatively, she was well for the first 2 weeks but suddenly developed left leg and lower back pain. Delayed diagnosis of a rare complication was detected only after postoperative CT scans were analysed 6 months after surgery. Initial imaging suggested exogenous bone growth affecting the lumbar plexus. Management and Outcome: Diagnostic nerve blocks revealed that L3 and L4 roots were affected. Exploratory surgery importantly revealed that de novo bone had not encased the nerve roots but revealed a chalky paste appearance consistent with extruded iFactor putty. Following the surgery, the patient′s symptoms improved considerably, emphasising the importance of accurate diagnosis and multidisciplinary team (MDT) involvement. Conclusion: This is a rare complication following OLIF, allowing extruded artificial graft to encase part of the lumbar plexus. This case supports the manufacturer′s assertion that iFactor does not lead to exogenous bone growth. The surgical exploration revealed a chalk‐like paste that was irritating the nerve plexus and highlights that surgical debridement of this substance under the psoas muscle is possible. This case also highlights that exploration of extruded bone grafts can be considered for patients presenting similarly after spinal fusion surgeries involving bone grafts.
- Open Access
- 27 November 2023
- Published by SAGE Publications in Global Spine Journal
- Vol. 15 (2) , 961-968
Six-Month Survivorship Prediction in Spinal Metastatic Patients by Oncologists Shows Reliable Prognostication
Study Design: A retrospective analysis of oncologist-provided prognoses vs actual survival outcomes of patients referred with Metastatic spinal cord compression (MSCC) to a supra-regional multidisciplinary team (MDT). Objectives: Prognostic scoring systems, such as the revised Tokuhashi, are commonly used to help guide the treatment of MSCC. However, scoring systems do not accommodate for the improved outcomes of contemporary cancer therapy. Oncologist-provided prognoses play an important role in real world rapid decision making. There is a paucity of evidence assessing the accuracy of the oncologist-provided prognosis. We conducted a retrospective study to evaluate this. Methods: Data was captured between January 2015 and December 2018. Patients were split into 2 groups: Group 1 (prognosis estimated 6 months). Median overall survival (mOS) and hazard ratio for death (HR) was assessed. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of the oncologist’s prognosis. Results: 829 patients were included. mOS in Group 1 was 5.8 months (95% CI 4.2-7.4 m), and in Group 2 mOS was not reached. Log rank test gave a Chi 2 of 131 ( P < .001). Cox regression analysis revealed a HR of .30 ( P < .001). Area under the ROC curve was 78%. Conclusions: Oncologist-provided prognosis is accurate in this cohort of unselected, consecutive MSCC patients. It reduced reliance on scoring systems that can become outdated. Given the rapid progress in cancer treatment, the oncologist’s prognostic prediction is integral in efficient and effective MSCC management to help rapidly determine surgical candidacy.
- 27 November 2023
- Published by SAGE Publications in Global Spine Journal
- Vol. 15 (2) , 961-968
Open AccessSix-Month Survivorship Prediction in Spinal Metastatic Patients by Oncologists Shows Reliable Prognostication
Study Design: A retrospective analysis of oncologist-provided prognoses vs actual survival outcomes of patients referred with Metastatic spinal cord compression (MSCC) to a supra-regional multidisciplinary team (MDT). Objectives: Prognostic scoring systems, such as the revised Tokuhashi, are commonly used to help guide the treatment of MSCC. However, scoring systems do not accommodate for the improved outcomes of contemporary cancer therapy. Oncologist-provided prognoses play an important role in real world rapid decision making. There is a paucity of evidence assessing the accuracy of the oncologist-provided prognosis. We conducted a retrospective study to evaluate this. Methods: Data was captured between January 2015 and December 2018. Patients were split into 2 groups: Group 1 (prognosis estimated 6 months). Median overall survival (mOS) and hazard ratio for death (HR) was assessed. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of the oncologist’s prognosis. Results: 829 patients were included. mOS in Group 1 was 5.8 months (95% CI 4.2-7.4 m), and in Group 2 mOS was not reached. Log rank test gave a Chi 2 of 131 ( P < .001). Cox regression analysis revealed a HR of .30 ( P < .001). Area under the ROC curve was 78%. Conclusions: Oncologist-provided prognosis is accurate in this cohort of unselected, consecutive MSCC patients. It reduced reliance on scoring systems that can become outdated. Given the rapid progress in cancer treatment, the oncologist’s prognostic prediction is integral in efficient and effective MSCC management to help rapidly determine surgical candidacy.
- Open Access
- 3 February 2023
- Published by MDPI AG in Healthcare
- Vol. 11 (3) , 445
An Examination of the Number of Adolescent Scoliotic Curves That Are Braceable at First Presentation to a Scoliosis Service
Adolescent idiopathic scoliosis (AIS) affects between 0.5% and 5.2% of adolescents and is progressive in two-thirds of cases. Bracing is an effective non-operative treatment for AIS and has been shown to prevent up to 72% of curves from requiring surgery. This paper explores the presentation of AIS in the UK and identifies who would be suitable for bracing, as per guidelines published by the Scoliosis Research Society (SRS) and British Scoliosis Society (BSS), through curve severity and skeletal maturity at presentation. There were 526 patients with AIS eligible for inclusion across three tertiary referral centres in the UK. The study period was individualised to each centre, between January 2012 and December 2021. Only 10% were appropriate for bracing via either SRS or BSS criteria. The rest were either too old, skeletally mature or had a curve size too large to benefit. By the end of data collection, 38% had undergone surgery for their scoliosis. In the UK, bracing for AIS is only suitable for a small number at presentation. Future efforts to minimise delays in specialist review and intervention will increase the number of those with AIS suitable for bracing and reduce the number and burden of operative interventions for AIS in the UK.
- 3 February 2023
- Published by MDPI AG in Healthcare
- Vol. 11 (3) , 445
Open AccessAn Examination of the Number of Adolescent Scoliotic Curves That Are Braceable at First Presentation to a Scoliosis Service
Adolescent idiopathic scoliosis (AIS) affects between 0.5% and 5.2% of adolescents and is progressive in two-thirds of cases. Bracing is an effective non-operative treatment for AIS and has been shown to prevent up to 72% of curves from requiring surgery. This paper explores the presentation of AIS in the UK and identifies who would be suitable for bracing, as per guidelines published by the Scoliosis Research Society (SRS) and British Scoliosis Society (BSS), through curve severity and skeletal maturity at presentation. There were 526 patients with AIS eligible for inclusion across three tertiary referral centres in the UK. The study period was individualised to each centre, between January 2012 and December 2021. Only 10% were appropriate for bracing via either SRS or BSS criteria. The rest were either too old, skeletally mature or had a curve size too large to benefit. By the end of data collection, 38% had undergone surgery for their scoliosis. In the UK, bracing for AIS is only suitable for a small number at presentation. Future efforts to minimise delays in specialist review and intervention will increase the number of those with AIS suitable for bracing and reduce the number and burden of operative interventions for AIS in the UK.
- Open Access
- 1 February 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (2) , 123-129
Dual modality of vertebral body tethering
Aims: Vertebral body tethering (VBT) is a non-fusion technique to correct scoliosis. It allows correction of scoliosis through growth modulation (GM) by tethering the convex side to allow concave unrestricted growth similar to the hemiepiphysiodesis concept. The other modality is anterior scoliosis correction (ASC) where the tether is able to perform most of the correction immediately where limited growth is expected. Methods: We conducted a retrospective analysis of clinical and radiological data of 20 patients aged between 9 and 17 years old, (with a 19 female: 1 male ratio) between January 2014 to December 2016 with a mean five-year follow-up (4 to 7). Results: There were ten patients in each group with a total of 23 curves operated on. VBT-GM mean age was 12.5 years (9 to 14) with a mean Risser classification of 0.63 (0 to 2) and VBT-ASC was 14.9 years (13 to 17) with a mean Risser classification of 3.66 (3 to 5). Mean preoperative VBT-GM Cobb was 47.4° (40° to 58°) with a Fulcrum unbend of 17.4 (1° to 41°), compared to VBT-ASC 56.5° (40° to 79°) with 30.6 (2° to 69°)unbend. Postoperative VBT-GM was 20.3° and VBT-ASC Cobb angle was 11.2°. The early postoperative correction rate was 54.3% versus 81% whereas Fulcrum Bending Correction Index (FBCI) was 93.1% vs 146.6%. The last Cobb angle on radiograph at mean five years’ follow-up was 19.4° (VBT-GM) and 16.5° (VBT-ASC). Patients with open triradiate cartilage (TRC) had three over-corrections. Overall, 5% of patients required fusion. This one patient alone had a over-correction, a second-stage tether release, and final conversion to fusion. Conclusion: We show a high success rate (95%) in helping children avoid fusion at five years post-surgery. VBT is a safe technique for correction of scoliosis in the skeletally immature patient. This is the first report at five years that shows two methods of VBT can be employed depending on the skeletal maturity of the patient: GM and ASC. Cite this article: Bone Jt Open 2022;3(2):123–129.
- 1 February 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (2) , 123-129
Open AccessDual modality of vertebral body tethering
Aims: Vertebral body tethering (VBT) is a non-fusion technique to correct scoliosis. It allows correction of scoliosis through growth modulation (GM) by tethering the convex side to allow concave unrestricted growth similar to the hemiepiphysiodesis concept. The other modality is anterior scoliosis correction (ASC) where the tether is able to perform most of the correction immediately where limited growth is expected. Methods: We conducted a retrospective analysis of clinical and radiological data of 20 patients aged between 9 and 17 years old, (with a 19 female: 1 male ratio) between January 2014 to December 2016 with a mean five-year follow-up (4 to 7). Results: There were ten patients in each group with a total of 23 curves operated on. VBT-GM mean age was 12.5 years (9 to 14) with a mean Risser classification of 0.63 (0 to 2) and VBT-ASC was 14.9 years (13 to 17) with a mean Risser classification of 3.66 (3 to 5). Mean preoperative VBT-GM Cobb was 47.4° (40° to 58°) with a Fulcrum unbend of 17.4 (1° to 41°), compared to VBT-ASC 56.5° (40° to 79°) with 30.6 (2° to 69°)unbend. Postoperative VBT-GM was 20.3° and VBT-ASC Cobb angle was 11.2°. The early postoperative correction rate was 54.3% versus 81% whereas Fulcrum Bending Correction Index (FBCI) was 93.1% vs 146.6%. The last Cobb angle on radiograph at mean five years’ follow-up was 19.4° (VBT-GM) and 16.5° (VBT-ASC). Patients with open triradiate cartilage (TRC) had three over-corrections. Overall, 5% of patients required fusion. This one patient alone had a over-correction, a second-stage tether release, and final conversion to fusion. Conclusion: We show a high success rate (95%) in helping children avoid fusion at five years post-surgery. VBT is a safe technique for correction of scoliosis in the skeletally immature patient. This is the first report at five years that shows two methods of VBT can be employed depending on the skeletal maturity of the patient: GM and ASC. Cite this article: Bone Jt Open 2022;3(2):123–129.
- Open Access
- 1 May 2021
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2021 (5) , rjab229
Corrigendum to: Tranexamic acid use in a patient with sickle cell disease undergoing posterior scoliosis correction surgery: safely mitigating bleeding and vaso-occlusive crises
In the originally published version of this manuscript, the authors were listed in the incorrect order. The correct order is: Millie Newall, Thamer A. Hamdan, Bisola Ajayi, Simon Weil, Timothy Bishop and Darren F. Lui. This has been corrected online.
- 1 May 2021
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2021 (5) , rjab229
Open AccessCorrigendum to: Tranexamic acid use in a patient with sickle cell disease undergoing posterior scoliosis correction surgery: safely mitigating bleeding and vaso-occlusive crises
In the originally published version of this manuscript, the authors were listed in the incorrect order. The correct order is: Millie Newall, Thamer A. Hamdan, Bisola Ajayi, Simon Weil, Timothy Bishop and Darren F. Lui. This has been corrected online.
- Open Access
- 28 May 2020
- Published by Wiley
St George's COVID shield for use by ENT surgeons performing tracheostomies
Objectives To investigate the ability of a physical barrier to reduce aerosol particle spread during a simulated aerosol generating procedure. Design A simulated aerosol generating procedure. Setting Standard hospital ward, St George’s Hospital, London. Participant One volunteer participant - they were healthy, asymptomatic, and a non-smoker. Main Outcome Measures 1. To compare the effect of the shield on particle frequency (according to particle size) at different locations. 2. To evaluate the length of time that particles remained within the shield, both with and without an aspiration unit. Results Clinical investigations using the shield demonstrated a twelve-fold decrease in the number of particles detected at the position of the operating surgeon when the shield was used (particle size 0.3μm; with shield 8662 versus 103800 without shield). Over a 7-minute period, there was a reduction in the number of particles. At 7 minutes, the total number of particles (size 0.3μm) measured within the shield was comparable to the particle frequency at ambient levels (8752 within the shield compared with 8592 within the ambient environment). The aspiration unit reduced the number of particles detected within the shield over time. An average of 9649 particles (similar to ambient level) sized 0.3μm were measured under the shield after 2 minutes when the aspiration unit was used. Conclusion The clinical simulation illustrates a significant decrease in the number of particles detected at varying locations when the shield is used. The shield, used with appropriate PPE, could help to minimise exposure to aerosol-generated particles such as during tracheostomies on patients with COVID-19.
- 28 May 2020
- Published by Wiley
Open AccessSt George's COVID shield for use by ENT surgeons performing tracheostomies
Objectives To investigate the ability of a physical barrier to reduce aerosol particle spread during a simulated aerosol generating procedure. Design A simulated aerosol generating procedure. Setting Standard hospital ward, St George’s Hospital, London. Participant One volunteer participant - they were healthy, asymptomatic, and a non-smoker. Main Outcome Measures 1. To compare the effect of the shield on particle frequency (according to particle size) at different locations. 2. To evaluate the length of time that particles remained within the shield, both with and without an aspiration unit. Results Clinical investigations using the shield demonstrated a twelve-fold decrease in the number of particles detected at the position of the operating surgeon when the shield was used (particle size 0.3μm; with shield 8662 versus 103800 without shield). Over a 7-minute period, there was a reduction in the number of particles. At 7 minutes, the total number of particles (size 0.3μm) measured within the shield was comparable to the particle frequency at ambient levels (8752 within the shield compared with 8592 within the ambient environment). The aspiration unit reduced the number of particles detected within the shield over time. An average of 9649 particles (similar to ambient level) sized 0.3μm were measured under the shield after 2 minutes when the aspiration unit was used. Conclusion The clinical simulation illustrates a significant decrease in the number of particles detected at varying locations when the shield is used. The shield, used with appropriate PPE, could help to minimise exposure to aerosol-generated particles such as during tracheostomies on patients with COVID-19.