Chengyu Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chengyu Zhang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jimin Chen
Institute of Laser Engineering, Beijing University of Technology, Beijing 100124, China
2 shared publications - Yanping Yuan
Beijing University of Technology
2 shared publications Chengkun Shi
Faculty of Materials and Manufacturing, Institute of Laser Engineering, Beijing University of Technology, Beijing, China
1 shared publicationJimin Chen
Institute of Laser Engineering, Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing 100124, China
1 shared publication- Shibo Xiang
Institute of Laser Engineering, Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing 100124, China
1 shared publication - Yanping Yuan
Beijing Engineering Research Center of 3D Printing for Digital Medical Health, Beijing University of Technology, Beijing 100124, China
1 shared publication
Latest Publications
- 18 September 2023
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 129 (1-2) , 587-599
Material extrusion-based fabrication of 316L stainless steel: analysis of debinding and sintering, mechanical properties, and corrosion resistance
- 18 September 2023
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 129 (1-2) , 587-599
Material extrusion-based fabrication of 316L stainless steel: analysis of debinding and sintering, mechanical properties, and corrosion resistance
- Open Access
Material Extrusion Based Fabrication of Surgical Implant Template and Accuracy Analysis
An implant template with great precision is significantly critical for clinical application. Currently, the application of an immediate implant remains limited by the deviations between the planned and actual achieved positions and long periods required for preparation of implant templates. Material Extrusion (MEX), as one kind of 3D printing method, is well known for its low cost and easy operation. However, the accuracy of the implant template printed by MEX has not been fully researched. To investigate the accuracy and feasibility of in vitro computer-guided surgery assisted with a MEX printed template, unidentified plaster samples missing a maxillary molar are digitalized. Mimics software (Materialise, Leuven, Belgium) is used for preoperative design. Surgical templates are fabricated by a MEX 3D printer (Lingtong III, Beijing SHINO, Beijing, China). Postoperative CBCT data are obtained after surgical template placement. The differences in positions of X, Y, Z, and dXYZ as well as angulations between the placed and the designed template are measured on labiolingual and mesiodistal planes. The deviations of the planned and the actual outcome in each dimension are observed and analyzed. Data from different samples indicate that the mean deviation of the angle measures approximately 3.640°. For position deviation, the maximum deviation is found in the z-direction and the mean deviation is about 0.365 ± 0.136 mm. The mean deviation of space Euclidean distance dXYZ is approximately 0.537 ± 0.123 mm. Implant templates fabricated by MEX present a relatively high accuracy for tooth-supported guide implantation.
Open AccessMaterial Extrusion Based Fabrication of Surgical Implant Template and Accuracy Analysis
An implant template with great precision is significantly critical for clinical application. Currently, the application of an immediate implant remains limited by the deviations between the planned and actual achieved positions and long periods required for preparation of implant templates. Material Extrusion (MEX), as one kind of 3D printing method, is well known for its low cost and easy operation. However, the accuracy of the implant template printed by MEX has not been fully researched. To investigate the accuracy and feasibility of in vitro computer-guided surgery assisted with a MEX printed template, unidentified plaster samples missing a maxillary molar are digitalized. Mimics software (Materialise, Leuven, Belgium) is used for preoperative design. Surgical templates are fabricated by a MEX 3D printer (Lingtong III, Beijing SHINO, Beijing, China). Postoperative CBCT data are obtained after surgical template placement. The differences in positions of X, Y, Z, and dXYZ as well as angulations between the placed and the designed template are measured on labiolingual and mesiodistal planes. The deviations of the planned and the actual outcome in each dimension are observed and analyzed. Data from different samples indicate that the mean deviation of the angle measures approximately 3.640°. For position deviation, the maximum deviation is found in the z-direction and the mean deviation is about 0.365 ± 0.136 mm. The mean deviation of space Euclidean distance dXYZ is approximately 0.537 ± 0.123 mm. Implant templates fabricated by MEX present a relatively high accuracy for tooth-supported guide implantation.
- Open Access
- 10 February 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (7) , 5954-5961
Effects of Process Parameters on the Corrosion Resistance and Biocompatibility of Ti6Al4V Parts Fabricated by Selective Laser Melting
Excellent biocompatibility and corrosion resistance of implants are essential for Ti6Al4V parts fabricated by selective laser melting (SLM) for biomedical applications. To achieve better corrosion resistance and biocompatibility of Ti6Al4V parts, the effects of SLM processing parameters on the corrosion resistance and the biocompatibility of Ti6Al4V parts are investigated by changing the scanning speeds and laser powers. The detailed influence mechanism of processing parameters on the properties of Ti6Al4V parts is studied from two aspects, including microstructure and defects. It is found that the corrosion resistance and biocompatibility of Ti6Al4V parts can be adjusted by changing the scanning speed and the laser power due to the constituent phase and the number and size of defect holes of Ti6Al4V parts. Compared with the laser power, the scanning speed has a stronger influence on the performance of the part, which can be used as “coarse tuning” based on the performance requirements. At the scanning speed of 1100 mm/s and the laser power of 280 W, Ti6Al4V parts with better corrosion resistance can be obtained. Ti6Al4V parts with better biocompatibility are fabricated at the scanning speed of 1200 mm/s and the laser power of 200 W.
- 10 February 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (7) , 5954-5961
Open AccessEffects of Process Parameters on the Corrosion Resistance and Biocompatibility of Ti6Al4V Parts Fabricated by Selective Laser Melting
Excellent biocompatibility and corrosion resistance of implants are essential for Ti6Al4V parts fabricated by selective laser melting (SLM) for biomedical applications. To achieve better corrosion resistance and biocompatibility of Ti6Al4V parts, the effects of SLM processing parameters on the corrosion resistance and the biocompatibility of Ti6Al4V parts are investigated by changing the scanning speeds and laser powers. The detailed influence mechanism of processing parameters on the properties of Ti6Al4V parts is studied from two aspects, including microstructure and defects. It is found that the corrosion resistance and biocompatibility of Ti6Al4V parts can be adjusted by changing the scanning speed and the laser power due to the constituent phase and the number and size of defect holes of Ti6Al4V parts. Compared with the laser power, the scanning speed has a stronger influence on the performance of the part, which can be used as “coarse tuning” based on the performance requirements. At the scanning speed of 1100 mm/s and the laser power of 280 W, Ti6Al4V parts with better corrosion resistance can be obtained. Ti6Al4V parts with better biocompatibility are fabricated at the scanning speed of 1200 mm/s and the laser power of 200 W.