Naseer A. Alhaboubi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Naseer A. Alhaboubi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Shahad Fadhil Alrubaye
Chemical Engineering Department, College of Engineering, Al Nahrain University, Baghdad, Iraq
3 shared publications - Hussein A. Al-Amili
Automated Manufacturing Engineering, Al-Khawarizmi College of Engineering, University of Baghdad, Baghdad, Iraq
2 shared publications - Ahmed A. Salman1 shared publication
Aiman H. Al-Allaq
Old Dominion University (ODU)/ USA
1 shared publication- Aiman H. Al-Allaq
Department of Mechanical and Aerospace Engineering, Old Dominion University 1 , 5115 Hampton Blvd, Norfolk, Virginia 23529
1 shared publication Ann A. Jawad Alani
Department of Chemical Engineering, Al-Nahrain University, Baghdad, Iraq
1 shared publication
Latest Publications
- 4 November 2026
- Published by Elsevier in Journal of Electrostatics
- Vol. 144
Electrohydrodynamic intensification of acetic acid mass transfer across a planar ethyl acetate/water interface
- 4 November 2026
- Published by Elsevier in Journal of Electrostatics
- Vol. 144
Electrohydrodynamic intensification of acetic acid mass transfer across a planar ethyl acetate/water interface
- Open Access
- 17 August 2025
- Published by Stecab Publishing in Journal of Medical Science, Biology, and Chemistry
- Vol. 2 (2) , 101-109
A Comprehensive Review of Solar Stills Performance and Design
The worldwide scarcity of potable water has increased significantly due to population expansion and the pollution of accessible water sources from anthropogenic activities. Solar stills are essential for supplying potable water via solar-powered distillation. Alterations, including phase change materials (PCM), nano fluids, and reflectors, markedly enhance heat retention and evaporation rates, leading to increased distillate production. Also, the efficacy of distillate production is significantly affected by design specifications, materials, and operational conditions. This paper delineates the passive and active designs, classifications of solar stills, single - effect and multi - effect kinds, and various improvements made to these types to augment yield, including heat storage, fins, reflectors, and collector types. Also, photovoltaic-thermal stills are encompassed in this review.
- 17 August 2025
- Published by Stecab Publishing in Journal of Medical Science, Biology, and Chemistry
- Vol. 2 (2) , 101-109
Open AccessA Comprehensive Review of Solar Stills Performance and Design
The worldwide scarcity of potable water has increased significantly due to population expansion and the pollution of accessible water sources from anthropogenic activities. Solar stills are essential for supplying potable water via solar-powered distillation. Alterations, including phase change materials (PCM), nano fluids, and reflectors, markedly enhance heat retention and evaporation rates, leading to increased distillate production. Also, the efficacy of distillate production is significantly affected by design specifications, materials, and operational conditions. This paper delineates the passive and active designs, classifications of solar stills, single - effect and multi - effect kinds, and various improvements made to these types to augment yield, including heat storage, fins, reflectors, and collector types. Also, photovoltaic-thermal stills are encompassed in this review.
- Open Access
- 8 March 2025
- Published by Tikrit University in Tikrit Journal of Engineering Sciences
- Vol. 32 (1) , 1-10
Impact of CO2 Flow Rate and Nutrient Augmentation on the Production of Bioelectricity in a Photosynthetic Microbial Carbon Capture Cell
This study investigates the potential of microbial carbon capture cells (MCCs) as a promising solution for energy generation and carbon capture. MCCs comprise two cylinders of plexiglass cells that serve as anode and cathode compartments (both utilize platinum mesh electrodes) and are separated by an ion exchange membrane (AMI-7001). Synechococcus is used as a photosynthetic microorganism in the cathode compartment, which plays a role in carbon dioxide (CO2) sequestration. Various factors, such as CO2 flow rate, nutrient augmentation, and light-dark cycles (16:8) (16 hours of light: 8 hours of darkness), were investigated for their impact on MCC performance. The results demonstrate that the high performance of MCC, presenting in a maximum output voltage, was obtained at a CO2 flow rate of 1.5 L/h as optimal conditions with 539 mV compared to 469 and 407 mV at a flow rate of 3 L/h and 4.5 L/h, respectively. Increasing the CO2 flow rate positively influenced power generation, with the highest power density of 22 mW/m2 achieved at a flow rate of 4.5 L/h. Nutrient augmentation was critical in enhancing power density, leading to an impressive outcome of 43.87 mW/m2. Enough illumination has been discovered as an important component in boosting higher voltage and power output. The study also looked at the development of microalgae growth in MCCs, employing absorbance to determine concentration. It was revealed that the kind of Synechococcus had considerable expansion in growth over time. This investigation provides helpful information about the factors affecting voltage output and biomass growth within MCCs. Optimizing carbon dioxide (CO2) flow rates, nutrition supplementation, and exposure to light appear to be essential requirements for enhancing power generation performance and permitting a long-term capture of carbon in microbial carbon capture cells.
- 8 March 2025
- Published by Tikrit University in Tikrit Journal of Engineering Sciences
- Vol. 32 (1) , 1-10
Open AccessImpact of CO2 Flow Rate and Nutrient Augmentation on the Production of Bioelectricity in a Photosynthetic Microbial Carbon Capture Cell
This study investigates the potential of microbial carbon capture cells (MCCs) as a promising solution for energy generation and carbon capture. MCCs comprise two cylinders of plexiglass cells that serve as anode and cathode compartments (both utilize platinum mesh electrodes) and are separated by an ion exchange membrane (AMI-7001). Synechococcus is used as a photosynthetic microorganism in the cathode compartment, which plays a role in carbon dioxide (CO2) sequestration. Various factors, such as CO2 flow rate, nutrient augmentation, and light-dark cycles (16:8) (16 hours of light: 8 hours of darkness), were investigated for their impact on MCC performance. The results demonstrate that the high performance of MCC, presenting in a maximum output voltage, was obtained at a CO2 flow rate of 1.5 L/h as optimal conditions with 539 mV compared to 469 and 407 mV at a flow rate of 3 L/h and 4.5 L/h, respectively. Increasing the CO2 flow rate positively influenced power generation, with the highest power density of 22 mW/m2 achieved at a flow rate of 4.5 L/h. Nutrient augmentation was critical in enhancing power density, leading to an impressive outcome of 43.87 mW/m2. Enough illumination has been discovered as an important component in boosting higher voltage and power output. The study also looked at the development of microalgae growth in MCCs, employing absorbance to determine concentration. It was revealed that the kind of Synechococcus had considerable expansion in growth over time. This investigation provides helpful information about the factors affecting voltage output and biomass growth within MCCs. Optimizing carbon dioxide (CO2) flow rates, nutrition supplementation, and exposure to light appear to be essential requirements for enhancing power generation performance and permitting a long-term capture of carbon in microbial carbon capture cells.
- Open Access
- 1 July 2024
- Published by Mustansiriyah University College of Engineering in Journal of Engineering and Sustainable Development
- Vol. 28 (4) , 428-438
Hardness Removal by A Continuous Flow Electrochemical Reactor from Different Types of Water
The present study focuses on the technique of hardness removal by using a novel reactor performing an electrocoagulation (EC) process. The variation of alkalinity is also recorded. Continuous flow experiments were conducted for Total Hardness (TH) removal using a transparent plastic reactor using aluminum plate electrodes that have holes so that the water flows through the plates in a zigzag way. The influence of various operating parameters such as the number of plates (two and four), flow rate (600, 1000 L/h), and water type (Tigris River & rejected water from Reverse Osmosis system RO) was investigated. The results showed that an increase in the number of electrodes led to an increase in the total hardness removal efficiency. In addition, the increase in the flow rate led to a decrease in the removal efficiency. For the rejected RO water type, the highest hardness removal rate was 16.16% for 4 plates electrodes and 600 L/h flow rate while for the river water was 29% for 4 plates electrodes and 1000 L/h.
- 1 July 2024
- Published by Mustansiriyah University College of Engineering in Journal of Engineering and Sustainable Development
- Vol. 28 (4) , 428-438
Open AccessHardness Removal by A Continuous Flow Electrochemical Reactor from Different Types of Water
The present study focuses on the technique of hardness removal by using a novel reactor performing an electrocoagulation (EC) process. The variation of alkalinity is also recorded. Continuous flow experiments were conducted for Total Hardness (TH) removal using a transparent plastic reactor using aluminum plate electrodes that have holes so that the water flows through the plates in a zigzag way. The influence of various operating parameters such as the number of plates (two and four), flow rate (600, 1000 L/h), and water type (Tigris River & rejected water from Reverse Osmosis system RO) was investigated. The results showed that an increase in the number of electrodes led to an increase in the total hardness removal efficiency. In addition, the increase in the flow rate led to a decrease in the removal efficiency. For the rejected RO water type, the highest hardness removal rate was 16.16% for 4 plates electrodes and 600 L/h flow rate while for the river water was 29% for 4 plates electrodes and 1000 L/h.
- Open Access
- 27 April 2024
- Published by Tikrit University in Tikrit Journal of Engineering Sciences
- Vol. 31 (2) , 205-218
Removal of Sulfate and Iron from a Water Solution Using a New Flow Pattern in an Electrocoagulation Reactor
This research examines the application of electrocoagulation (EC) by employing two water sources: river water and rejected water from a reverse osmosis system. To assess the impact of numerous factors on the removal efficiency of sulfate and iron, continuous flow experiments were conducted using bipolar and monopolar aluminum electrodes. The parameters studied included the number of electrodes (2, and 4) and flow rates (600, and 1000 L/h). The experimental findings revealed that increasing the number of electrodes improved the removal efficiency. Conversely, an increase in flow rate resulted in a decrease in removal efficiency for both water sources. For concentrated water, the best sulfate removal reached 47% (for four plates with 600L/h), whereas for the river, the highest sulfate removal was 50% (for four plates and a flow rate of 1000 L/h). For river water samples, the best iron removal was 56% (for four plates and 600L/h), whereas for concentrated water samples, the most significant removal was 79% (for four plates and 600L/h).
- 27 April 2024
- Published by Tikrit University in Tikrit Journal of Engineering Sciences
- Vol. 31 (2) , 205-218
Open AccessRemoval of Sulfate and Iron from a Water Solution Using a New Flow Pattern in an Electrocoagulation Reactor
This research examines the application of electrocoagulation (EC) by employing two water sources: river water and rejected water from a reverse osmosis system. To assess the impact of numerous factors on the removal efficiency of sulfate and iron, continuous flow experiments were conducted using bipolar and monopolar aluminum electrodes. The parameters studied included the number of electrodes (2, and 4) and flow rates (600, and 1000 L/h). The experimental findings revealed that increasing the number of electrodes improved the removal efficiency. Conversely, an increase in flow rate resulted in a decrease in removal efficiency for both water sources. For concentrated water, the best sulfate removal reached 47% (for four plates with 600L/h), whereas for the river, the highest sulfate removal was 50% (for four plates and a flow rate of 1000 L/h). For river water samples, the best iron removal was 56% (for four plates and 600L/h), whereas for concentrated water samples, the most significant removal was 79% (for four plates and 600L/h).
- Open Access
- 1 March 2024
- Published by Al-Khwarizmi Engineering Journal in Al-Khwarizmi Engineering Journal
- Vol. 20 (1) , 17-32
Factors Affecting Electrocoagulation Process for Different Water Types: A review
Raw water must meet specific physical, chemical, and biological requirements to be suitable for drinking. There are various techniques available for treating wastewater, and aside from conventional methods that involve chemicals, electrocoagulation is an efficient and advanced approach. Electrocoagulation has proven effective in treating many pollutants, including bacteria, viruses, iron, fluoride, sulfate, boron, hardness, and turbidity. Total suspended solids, organic and inorganic materials, chemical oxygen demand COD, biochemical oxygen demand BOD, and color. It finds extensive application in treating different types of water and wastewater due to its exceptional ability to remove diverse contaminants. Recently, electrocoagulation has garnered significant attention due to its remarkable efficiency in treating various pollutants. This article provides a thorough analysis of contemporary literature that is committed to using electrocoagulation in a variety of water treatment methods, with a focus on the different variables affecting the process performance, such as electrical current, electrode type, electrode configuration, initial pH, electrode distance, NaCl concentration, initial concentration of pollutants, operating temperature and electrolysis time.
- 1 March 2024
- Published by Al-Khwarizmi Engineering Journal in Al-Khwarizmi Engineering Journal
- Vol. 20 (1) , 17-32
Open AccessFactors Affecting Electrocoagulation Process for Different Water Types: A review
Raw water must meet specific physical, chemical, and biological requirements to be suitable for drinking. There are various techniques available for treating wastewater, and aside from conventional methods that involve chemicals, electrocoagulation is an efficient and advanced approach. Electrocoagulation has proven effective in treating many pollutants, including bacteria, viruses, iron, fluoride, sulfate, boron, hardness, and turbidity. Total suspended solids, organic and inorganic materials, chemical oxygen demand COD, biochemical oxygen demand BOD, and color. It finds extensive application in treating different types of water and wastewater due to its exceptional ability to remove diverse contaminants. Recently, electrocoagulation has garnered significant attention due to its remarkable efficiency in treating various pollutants. This article provides a thorough analysis of contemporary literature that is committed to using electrocoagulation in a variety of water treatment methods, with a focus on the different variables affecting the process performance, such as electrical current, electrode type, electrode configuration, initial pH, electrode distance, NaCl concentration, initial concentration of pollutants, operating temperature and electrolysis time.
- Open Access
- 11 February 2022
- Published by EDP Sciences in Science and Technology for Energy Transition
- Vol. 77, 2
Constant distillate composition of batch distillation column with variable reflux mode based on still pot concentration
The objective of this work is to control the constant distillate composition of batch distillation column xD. A new correlation developed involved the instant reflux ratio value R with a composition of the remaining mixture in the bottom pot (boiler) xB. Also adding the dynamic time as ahead time (+dt) to the control algorithm to increase the R to anticipate the changes in xD. +dt was calculated using an electroconductive tracer that was injected both in the bottom pot and in the top tray to estimate the upward and the downward dynamic time. The proposed correlation was successfully applied as a control strategy on a glass batch distillation pilot plant that has 5 cm diameter, 1 m long, eight sieve trays, and Methanol–Water mixture as a system. The real-time experimental runs of the suggested control algorithm applied by manipulating the reflux stream that affects the changes that happened in the top composition product to keep it constant. The proposed procedure shows a quick and stable response for distillate product composition during the operating time that minimizes and saves the energy supplied to the boiler. Moreover, the system gives a straight, smooth linear constant distillate product even in case of disturbing the system.
- 11 February 2022
- Published by EDP Sciences in Science and Technology for Energy Transition
- Vol. 77, 2
Open AccessConstant distillate composition of batch distillation column with variable reflux mode based on still pot concentration
The objective of this work is to control the constant distillate composition of batch distillation column xD. A new correlation developed involved the instant reflux ratio value R with a composition of the remaining mixture in the bottom pot (boiler) xB. Also adding the dynamic time as ahead time (+dt) to the control algorithm to increase the R to anticipate the changes in xD. +dt was calculated using an electroconductive tracer that was injected both in the bottom pot and in the top tray to estimate the upward and the downward dynamic time. The proposed correlation was successfully applied as a control strategy on a glass batch distillation pilot plant that has 5 cm diameter, 1 m long, eight sieve trays, and Methanol–Water mixture as a system. The real-time experimental runs of the suggested control algorithm applied by manipulating the reflux stream that affects the changes that happened in the top composition product to keep it constant. The proposed procedure shows a quick and stable response for distillate product composition during the operating time that minimizes and saves the energy supplied to the boiler. Moreover, the system gives a straight, smooth linear constant distillate product even in case of disturbing the system.