Gregory Thomas Kennedy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gregory Thomas Kennedy has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
- Feredun Azari
Division of Thoracic Surgery, University of Pennsylvania Perelman School of Medicine, Philadelphia, USA
9 shared publications Alix Segil
8 shared publications- Ashley Chang
Department of Surgery, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania
8 shared publications Edward J. Delikatny
Department of Radiology, University of Pennsylvania School of Medicine, Philadelphia, USA
8 shared publications- Sunil Singhal
Division of Thoracic Surgery, Department of Surgery, University of Pennsylvania, Philadelphia, PA 19104, USA
8 shared publications - Bilal Nadeem
Department of Surgery, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania
7 shared publications
Latest Publications
- 11 July 2024
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 26 (4) , 585-592
A Phase 2 Multicenter Clinical Trial of Intraoperative Molecular Imaging of Lung Cancer with a pH-Activatable Nanoprobe
Purpose Intraoperative molecular imaging (IMI) uses tumor-targeted optical contrast agents to improve identification and clearance of cancer. Recently, a probe has been developed that only fluoresces when activated in an acidic pH, which is common to many malignancies. We report the first multicenter Phase 2 trial of a pH-activatable nanoprobe (pegsitacianine, ONM-100) for IMI of lung cancer. Methods Patients with suspected or biopsy-confirmed lung cancer scheduled for sublobar resection were administered a single intravenous infusion of pegsitacianine (1 mg/kg) one to three days prior to surgery. Intraoperatively, the patients underwent a white light thoracoscopic evaluation, and then were imaged with an NIR thoracoscope to detect tumor fluorescence. The primary study endpoint was the proportion of patients with a clinically significant event (CSE) which was defined as an intraoperative discovery during IMI that led to a change in the surgical procedure. Possible CSEs included (i) localizing the index lung nodule that could not be located by white light, (ii) identifying a synchronous malignant lesion, or (iii) recognizing a close surgical margin (< = 10 mm). Secondary endpoints were sensitivity, specificity, NPV, and PPV of pegsitacianine in detecting tumor-containing tissue. The safety evaluation was based on adverse event reporting, clinical laboratory parameters, and physical examinations. Results Twenty patients were confirmed as eligible and administered pegsitacianine. Most of the patients were female (n = 12 [60%]), middle-aged (mean age 63.4 years), and former smokers (n = 13 [65%], 28.6 mean pack years). Mean lesion size was 1.9 cm, and most lesions (n = 17 [85%]) were malignant. The most common histologic subtype was adenocarcinoma (n = 9). By utilizing IMI with pegsitacianine, one patient had a CSE in the detection of a close margin and another had localization of a tumor not detectable by traditional surgical means. Six of 19 (31.6%) malignant lesions fluoresced with mean tumor-to-background ratio (TBR) of 3.00, as compared to TBR of 1.20 for benign lesions (n = 3). Sensitivity and specificity of pegsitacianine-based IMI for detecting malignant tissue was 31.6% and 33.3%, respectively. Positive predictive value (PPV) and negative predictive value (NPV) of pegsitacianine-based IMI was 75% and 7.1%, respectively. Pegsitacianine-based imaging was not effective in differentiating benign and malignant lymph nodes. From a safety perspective, no drug-related serious adverse events occurred. Four patients experienced mild pegsitacianine-related infusion reactions which required discontinuing the study drug with complete resolution of symptoms. Conclusions Pegsitacianine-based IMI, though well tolerated from a safety perspective, does not consistently label lung tumors during resection and does not provide significant clinical benefit over existing standards of surgical care. The biology of lung tumors may not be as acidic as other solid tumors in the body thereby not activating the probe as predicted.
- 11 July 2024
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 26 (4) , 585-592
A Phase 2 Multicenter Clinical Trial of Intraoperative Molecular Imaging of Lung Cancer with a pH-Activatable Nanoprobe
Purpose Intraoperative molecular imaging (IMI) uses tumor-targeted optical contrast agents to improve identification and clearance of cancer. Recently, a probe has been developed that only fluoresces when activated in an acidic pH, which is common to many malignancies. We report the first multicenter Phase 2 trial of a pH-activatable nanoprobe (pegsitacianine, ONM-100) for IMI of lung cancer. Methods Patients with suspected or biopsy-confirmed lung cancer scheduled for sublobar resection were administered a single intravenous infusion of pegsitacianine (1 mg/kg) one to three days prior to surgery. Intraoperatively, the patients underwent a white light thoracoscopic evaluation, and then were imaged with an NIR thoracoscope to detect tumor fluorescence. The primary study endpoint was the proportion of patients with a clinically significant event (CSE) which was defined as an intraoperative discovery during IMI that led to a change in the surgical procedure. Possible CSEs included (i) localizing the index lung nodule that could not be located by white light, (ii) identifying a synchronous malignant lesion, or (iii) recognizing a close surgical margin (< = 10 mm). Secondary endpoints were sensitivity, specificity, NPV, and PPV of pegsitacianine in detecting tumor-containing tissue. The safety evaluation was based on adverse event reporting, clinical laboratory parameters, and physical examinations. Results Twenty patients were confirmed as eligible and administered pegsitacianine. Most of the patients were female (n = 12 [60%]), middle-aged (mean age 63.4 years), and former smokers (n = 13 [65%], 28.6 mean pack years). Mean lesion size was 1.9 cm, and most lesions (n = 17 [85%]) were malignant. The most common histologic subtype was adenocarcinoma (n = 9). By utilizing IMI with pegsitacianine, one patient had a CSE in the detection of a close margin and another had localization of a tumor not detectable by traditional surgical means. Six of 19 (31.6%) malignant lesions fluoresced with mean tumor-to-background ratio (TBR) of 3.00, as compared to TBR of 1.20 for benign lesions (n = 3). Sensitivity and specificity of pegsitacianine-based IMI for detecting malignant tissue was 31.6% and 33.3%, respectively. Positive predictive value (PPV) and negative predictive value (NPV) of pegsitacianine-based IMI was 75% and 7.1%, respectively. Pegsitacianine-based imaging was not effective in differentiating benign and malignant lymph nodes. From a safety perspective, no drug-related serious adverse events occurred. Four patients experienced mild pegsitacianine-related infusion reactions which required discontinuing the study drug with complete resolution of symptoms. Conclusions Pegsitacianine-based IMI, though well tolerated from a safety perspective, does not consistently label lung tumors during resection and does not provide significant clinical benefit over existing standards of surgical care. The biology of lung tumors may not be as acidic as other solid tumors in the body thereby not activating the probe as predicted.
- 11 September 2023
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 25 (5) , 824-832
A pH-Activatable Nanoprobe Labels Diverse Histologic Subtypes of Human Lung Cancer During Resection
Background Intraoperative molecular imaging (IMI) uses tumor-targeted optical contrast agents to improve identification and clearance of cancer during surgery. Recently, pH-activatable contrast agents have been developed but none has been tested in lung cancer. Here, we report the successful clinical translation of pegsitacianine (ONM-100), a pH-activatable nanoprobe, for fluorescence-guided lung cancer resection. Methods We first characterized the pH setpoint for pegsitacianine fluorescence activation in vitro. We then optimized the specificity, dosing, and timing of pegsitacianine in murine flank xenograft models of lung adenocarcinoma and squamous cell carcinoma. Finally, we tested pegsitacianine in humans undergoing lung cancer surgery as part of an ongoing phase 2 trial. Results We found that the fluorescence activation of pegsitacianine occurred below physiologic pH in vitro. Using preclinical models of lung cancer, we found that the probe selectively labeled both adenocarcinoma and squamous cell carcinoma xenografts (mean tumor-to-background ratio [TBR] > 2.0 for all cell lines). In the human pilot study, we report cases in which pegsitacianine localized pulmonary adenocarcinoma and pulmonary squamous cell carcinoma (TBRs= 2.7 and 2.4) in real time to illustrate its successful clinical translation and potential to improve surgical management. Conclusions This translational study demonstrates the feasibility of pegsitacianine as an IMI probe to label the two most common histologic subtypes of human lung cancer.
- 11 September 2023
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 25 (5) , 824-832
A pH-Activatable Nanoprobe Labels Diverse Histologic Subtypes of Human Lung Cancer During Resection
Background Intraoperative molecular imaging (IMI) uses tumor-targeted optical contrast agents to improve identification and clearance of cancer during surgery. Recently, pH-activatable contrast agents have been developed but none has been tested in lung cancer. Here, we report the successful clinical translation of pegsitacianine (ONM-100), a pH-activatable nanoprobe, for fluorescence-guided lung cancer resection. Methods We first characterized the pH setpoint for pegsitacianine fluorescence activation in vitro. We then optimized the specificity, dosing, and timing of pegsitacianine in murine flank xenograft models of lung adenocarcinoma and squamous cell carcinoma. Finally, we tested pegsitacianine in humans undergoing lung cancer surgery as part of an ongoing phase 2 trial. Results We found that the fluorescence activation of pegsitacianine occurred below physiologic pH in vitro. Using preclinical models of lung cancer, we found that the probe selectively labeled both adenocarcinoma and squamous cell carcinoma xenografts (mean tumor-to-background ratio [TBR] > 2.0 for all cell lines). In the human pilot study, we report cases in which pegsitacianine localized pulmonary adenocarcinoma and pulmonary squamous cell carcinoma (TBRs= 2.7 and 2.4) in real time to illustrate its successful clinical translation and potential to improve surgical management. Conclusions This translational study demonstrates the feasibility of pegsitacianine as an IMI probe to label the two most common histologic subtypes of human lung cancer.
- Open Access
- 1 May 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (05) , 050901-33
Intraoperative molecular imaging: 3rd biennial clinical trials update
According to the World Health Organization, there were almost 18 million patients living with cancer in 2020. It is estimated that over 14 million patients will require oncologic surgery in 2040. This is a 52% increase from 2018 estimations.1 Due to the importance of a complete (R0) resection on survival and the increase in detection of early-stage disease, surgical resection remains an important treatment of solid tumors.2,3 Achieving an R0 resection and identifying disease in lymph nodes or synchronous lesions has been shown repeatedly to improve oncologic outcomes and is a mainstay of curative-intent treatment.4 However, achieving these margins and finding residual disease during surgery remains a challenge for surgical oncologists. This is mainly due to the inability to see microscopic disease left behind and, at times, uncertainty about involvement of vital structures.
- 1 May 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (05) , 050901-33
Open AccessIntraoperative molecular imaging: 3rd biennial clinical trials update
According to the World Health Organization, there were almost 18 million patients living with cancer in 2020. It is estimated that over 14 million patients will require oncologic surgery in 2040. This is a 52% increase from 2018 estimations.1 Due to the importance of a complete (R0) resection on survival and the increase in detection of early-stage disease, surgical resection remains an important treatment of solid tumors.2,3 Achieving an R0 resection and identifying disease in lymph nodes or synchronous lesions has been shown repeatedly to improve oncologic outcomes and is a mainstay of curative-intent treatment.4 However, achieving these margins and finding residual disease during surgery remains a challenge for surgical oncologists. This is mainly due to the inability to see microscopic disease left behind and, at times, uncertainty about involvement of vital structures.
- Open Access
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Data from A Cathepsin-Targeted Quenched Activity–Based Probe Facilitates Enhanced Detection of Human Tumors during Resection
Supplementary Data from A Cathepsin-Targeted Quenched Activity–Based Probe Facilitates Enhanced Detection of Human Tumors during Resection
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Data from A Cathepsin-Targeted Quenched Activity–Based Probe Facilitates Enhanced Detection of Human Tumors during Resection
Supplementary Data from A Cathepsin-Targeted Quenched Activity–Based Probe Facilitates Enhanced Detection of Human Tumors during Resection
- Open Access
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Data from A Cathepsin-Targeted Quenched Activity–Based Probe Facilitates Enhanced Detection of Human Tumors during Resection
Purpose:Fluorescence-guided surgery using tumor-targeted contrast agents has been developed to improve the completeness of oncologic resections. Quenched activity–based probes that fluoresce after covalently binding to tumor-specific enzymes have been proposed to improve specificity, but none have been tested in humans. Here, we report the successful clinical translation of a cathepsin activity–based probe (VGT-309) for fluorescence-guided surgery.Experimental Design:We optimized the specificity, dosing, and timing of VGT-309 in preclinical models of lung cancer. To evaluate clinical feasibility, we conducted a canine study of VGT-309 during pulmonary tumor resection. We then conducted a randomized, double-blind, dose-escalation study in healthy human volunteers receiving VGT-309 to evaluate safety. Finally, we tested VGT-309 in humans undergoing lung cancer surgery.Results:In preclinical models, we found highly specific tumor cell labeling that was blocked by a broad spectrum cathepsin inhibitor. When evaluating VGT-309 for guidance during resection of canine tumors, we found that the probe selectively labeled tumors and demonstrated high tumor-to-background ratio (TBR; range: 2.15–3.71). In the Phase I human study, we found that VGT-309 was safe at all doses studied. In the ongoing Phase II trial, we report two cases in which VGT-309 localized visually occult, non-palpable tumors (TBRs = 2.83 and 7.18) in real time to illustrate its successful clinical translation and potential to improve surgical management.Conclusions:This first-in-human study demonstrates the safety and feasibility of VGT-309 to label human pulmonary tumors during resection. These results may be generalizable to other cancers due to cathepsin overexpression in many solid tumors.
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessData from A Cathepsin-Targeted Quenched Activity–Based Probe Facilitates Enhanced Detection of Human Tumors during Resection
Purpose:Fluorescence-guided surgery using tumor-targeted contrast agents has been developed to improve the completeness of oncologic resections. Quenched activity–based probes that fluoresce after covalently binding to tumor-specific enzymes have been proposed to improve specificity, but none have been tested in humans. Here, we report the successful clinical translation of a cathepsin activity–based probe (VGT-309) for fluorescence-guided surgery.Experimental Design:We optimized the specificity, dosing, and timing of VGT-309 in preclinical models of lung cancer. To evaluate clinical feasibility, we conducted a canine study of VGT-309 during pulmonary tumor resection. We then conducted a randomized, double-blind, dose-escalation study in healthy human volunteers receiving VGT-309 to evaluate safety. Finally, we tested VGT-309 in humans undergoing lung cancer surgery.Results:In preclinical models, we found highly specific tumor cell labeling that was blocked by a broad spectrum cathepsin inhibitor. When evaluating VGT-309 for guidance during resection of canine tumors, we found that the probe selectively labeled tumors and demonstrated high tumor-to-background ratio (TBR; range: 2.15–3.71). In the Phase I human study, we found that VGT-309 was safe at all doses studied. In the ongoing Phase II trial, we report two cases in which VGT-309 localized visually occult, non-palpable tumors (TBRs = 2.83 and 7.18) in real time to illustrate its successful clinical translation and potential to improve surgical management.Conclusions:This first-in-human study demonstrates the safety and feasibility of VGT-309 to label human pulmonary tumors during resection. These results may be generalizable to other cancers due to cathepsin overexpression in many solid tumors.
- Open Access
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Data from A Cathepsin-Targeted Quenched Activity–Based Probe Facilitates Enhanced Detection of Human Tumors during Resection
Supplementary Data from A Cathepsin-Targeted Quenched Activity–Based Probe Facilitates Enhanced Detection of Human Tumors during Resection
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Data from A Cathepsin-Targeted Quenched Activity–Based Probe Facilitates Enhanced Detection of Human Tumors during Resection
Supplementary Data from A Cathepsin-Targeted Quenched Activity–Based Probe Facilitates Enhanced Detection of Human Tumors during Resection
- Open Access
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Data from A Cathepsin-Targeted Quenched Activity–Based Probe Facilitates Enhanced Detection of Human Tumors during Resection
Purpose:Fluorescence-guided surgery using tumor-targeted contrast agents has been developed to improve the completeness of oncologic resections. Quenched activity–based probes that fluoresce after covalently binding to tumor-specific enzymes have been proposed to improve specificity, but none have been tested in humans. Here, we report the successful clinical translation of a cathepsin activity–based probe (VGT-309) for fluorescence-guided surgery.Experimental Design:We optimized the specificity, dosing, and timing of VGT-309 in preclinical models of lung cancer. To evaluate clinical feasibility, we conducted a canine study of VGT-309 during pulmonary tumor resection. We then conducted a randomized, double-blind, dose-escalation study in healthy human volunteers receiving VGT-309 to evaluate safety. Finally, we tested VGT-309 in humans undergoing lung cancer surgery.Results:In preclinical models, we found highly specific tumor cell labeling that was blocked by a broad spectrum cathepsin inhibitor. When evaluating VGT-309 for guidance during resection of canine tumors, we found that the probe selectively labeled tumors and demonstrated high tumor-to-background ratio (TBR; range: 2.15–3.71). In the Phase I human study, we found that VGT-309 was safe at all doses studied. In the ongoing Phase II trial, we report two cases in which VGT-309 localized visually occult, non-palpable tumors (TBRs = 2.83 and 7.18) in real time to illustrate its successful clinical translation and potential to improve surgical management.Conclusions:This first-in-human study demonstrates the safety and feasibility of VGT-309 to label human pulmonary tumors during resection. These results may be generalizable to other cancers due to cathepsin overexpression in many solid tumors.
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessData from A Cathepsin-Targeted Quenched Activity–Based Probe Facilitates Enhanced Detection of Human Tumors during Resection
Purpose:Fluorescence-guided surgery using tumor-targeted contrast agents has been developed to improve the completeness of oncologic resections. Quenched activity–based probes that fluoresce after covalently binding to tumor-specific enzymes have been proposed to improve specificity, but none have been tested in humans. Here, we report the successful clinical translation of a cathepsin activity–based probe (VGT-309) for fluorescence-guided surgery.Experimental Design:We optimized the specificity, dosing, and timing of VGT-309 in preclinical models of lung cancer. To evaluate clinical feasibility, we conducted a canine study of VGT-309 during pulmonary tumor resection. We then conducted a randomized, double-blind, dose-escalation study in healthy human volunteers receiving VGT-309 to evaluate safety. Finally, we tested VGT-309 in humans undergoing lung cancer surgery.Results:In preclinical models, we found highly specific tumor cell labeling that was blocked by a broad spectrum cathepsin inhibitor. When evaluating VGT-309 for guidance during resection of canine tumors, we found that the probe selectively labeled tumors and demonstrated high tumor-to-background ratio (TBR; range: 2.15–3.71). In the Phase I human study, we found that VGT-309 was safe at all doses studied. In the ongoing Phase II trial, we report two cases in which VGT-309 localized visually occult, non-palpable tumors (TBRs = 2.83 and 7.18) in real time to illustrate its successful clinical translation and potential to improve surgical management.Conclusions:This first-in-human study demonstrates the safety and feasibility of VGT-309 to label human pulmonary tumors during resection. These results may be generalizable to other cancers due to cathepsin overexpression in many solid tumors.
- Open Access
- 9 December 2022
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 17 (1) , 1-7
Novel intraoperative near-infrared imaging strategy to identify abnormalities in the anterior mediastinum
Thoracic surgeons are frequently asked to biopsy suspicious tissues in the anterior mediastinum to discriminate between a reactive versus malignant pathology such as lymph nodes. The most common benign cause of a mediastinal lymph node is a reactive lymph node from a prior infection or inflammatory process such as post-COVID or granulomatous disease. The most common malignant cause is a lymphoproliferative disorder but also metastatic disease from neck, breast and other regional cancers. Biopsies in this location are challenging because they are far from the trachea and the sternum is a barrier to most diagnostic procedures. Thus, a surgical biopsy is frequently required and a common procedure for Thoracic surgeons. Technically, identifying these lesions can be challenging, particularly for small lesions or those in patients with high body mass index. In order to improve contrast between diseased tissue in the anterior mediastinum and surrounding adipose tissue, we have been studying near-infrared imaging during surgery using indocyanine green (ICG) to give contrast to the abnormal tissues and to avoid an unnecessary extended resection. We developed a modified technique to give ICG to a patient during a biopsy in the anterior mediastinum to specifically highlight abnormal tissues. As a proof-of-principle, we present a case of a young woman with a suspicious 2 cm mediastinal lymph node that required surgical biopsy.
- 9 December 2022
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 17 (1) , 1-7
Open AccessNovel intraoperative near-infrared imaging strategy to identify abnormalities in the anterior mediastinum
Thoracic surgeons are frequently asked to biopsy suspicious tissues in the anterior mediastinum to discriminate between a reactive versus malignant pathology such as lymph nodes. The most common benign cause of a mediastinal lymph node is a reactive lymph node from a prior infection or inflammatory process such as post-COVID or granulomatous disease. The most common malignant cause is a lymphoproliferative disorder but also metastatic disease from neck, breast and other regional cancers. Biopsies in this location are challenging because they are far from the trachea and the sternum is a barrier to most diagnostic procedures. Thus, a surgical biopsy is frequently required and a common procedure for Thoracic surgeons. Technically, identifying these lesions can be challenging, particularly for small lesions or those in patients with high body mass index. In order to improve contrast between diseased tissue in the anterior mediastinum and surrounding adipose tissue, we have been studying near-infrared imaging during surgery using indocyanine green (ICG) to give contrast to the abnormal tissues and to avoid an unnecessary extended resection. We developed a modified technique to give ICG to a patient during a biopsy in the anterior mediastinum to specifically highlight abnormal tissues. As a proof-of-principle, we present a case of a young woman with a suspicious 2 cm mediastinal lymph node that required surgical biopsy.
- Open Access
- 14 July 2022
- Published by SAGE Publications in Molecular Imaging
- Vol. 2022, 5447290
Preclinical Evaluation of an Activity-Based Probe for Intraoperative Imaging of Esophageal Cancer
Background. Early detection and complete resection are important prognostic factors for esophageal cancer (EC). Intraoperative molecular imaging (IMI) using tumor-targeted tracers is effective in many cancer types. However, there are no EC-specific IMI tracers. We sought to test a cathepsin activity-based tracer (VGT-309) for EC resection. Methods. Murine (AKR, HNM007) and human (OE19) EC cell lines were screened for cathepsin expression by western blotting. In vitro binding affinity of VGT-309 was evaluated by fluorescence microscopy. Flank tumor models were developed by injecting EC cells into the flanks of BALB/c or athymic nude mice. Mice pretreated with a cathepsin inhibitor (JPM-OEt) were used to confirm on target binding. Animals were injected with 2mg/kg VGT-309, underwent IMI, and were sacrificed 24 hours after injection. Results. Cathepsins B, L, S, and X were expressed by EC cell lines, and all cell lines were labeled in vitro with VGT-309. Fluorescent signal was eliminated when cells were pretreated with JPM-OEt. On biodistribution analysis, VGT-309 accumulated in the liver, kidneys, and spleen without other organ involvement. VGT-309 selectively accumulated in flank allografts and xenografts, with mean signal-to-background ratio of 5.21 (IQR: 4.18-6.73) for flank allografts and 4.34 (IQR: 3.75-5.02) for flank xenografts. Fluorescence microscopy and histopathological analysis confirmed the selective accumulation of the tracer in tumors compared to background normal tissues. Conclusions. VGT-309 is an effective tracer for IMI of esophageal cancer. There is potential for clinical translation both as an adjunct to endoscopic detection and for complete removal of disease during esophagectomy.
- 14 July 2022
- Published by SAGE Publications in Molecular Imaging
- Vol. 2022, 5447290
Open AccessPreclinical Evaluation of an Activity-Based Probe for Intraoperative Imaging of Esophageal Cancer
Background. Early detection and complete resection are important prognostic factors for esophageal cancer (EC). Intraoperative molecular imaging (IMI) using tumor-targeted tracers is effective in many cancer types. However, there are no EC-specific IMI tracers. We sought to test a cathepsin activity-based tracer (VGT-309) for EC resection. Methods. Murine (AKR, HNM007) and human (OE19) EC cell lines were screened for cathepsin expression by western blotting. In vitro binding affinity of VGT-309 was evaluated by fluorescence microscopy. Flank tumor models were developed by injecting EC cells into the flanks of BALB/c or athymic nude mice. Mice pretreated with a cathepsin inhibitor (JPM-OEt) were used to confirm on target binding. Animals were injected with 2mg/kg VGT-309, underwent IMI, and were sacrificed 24 hours after injection. Results. Cathepsins B, L, S, and X were expressed by EC cell lines, and all cell lines were labeled in vitro with VGT-309. Fluorescent signal was eliminated when cells were pretreated with JPM-OEt. On biodistribution analysis, VGT-309 accumulated in the liver, kidneys, and spleen without other organ involvement. VGT-309 selectively accumulated in flank allografts and xenografts, with mean signal-to-background ratio of 5.21 (IQR: 4.18-6.73) for flank allografts and 4.34 (IQR: 3.75-5.02) for flank xenografts. Fluorescence microscopy and histopathological analysis confirmed the selective accumulation of the tracer in tumors compared to background normal tissues. Conclusions. VGT-309 is an effective tracer for IMI of esophageal cancer. There is potential for clinical translation both as an adjunct to endoscopic detection and for complete removal of disease during esophagectomy.
- 6 July 2022
- Published by American Association for Cancer Research (AACR) in Clinical Cancer Research
- Vol. 28 (17) , 3729-3741
A Cathepsin-Targeted Quenched Activity–Based Probe Facilitates Enhanced Detection of Human Tumors during Resection
Purpose: Fluorescence-guided surgery using tumor-targeted contrast agents has been developed to improve the completeness of oncologic resections. Quenched activity–based probes that fluoresce after covalently binding to tumor-specific enzymes have been proposed to improve specificity, but none have been tested in humans. Here, we report the successful clinical translation of a cathepsin activity–based probe (VGT-309) for fluorescence-guided surgery. Experimental Design: We optimized the specificity, dosing, and timing of VGT-309 in preclinical models of lung cancer. To evaluate clinical feasibility, we conducted a canine study of VGT-309 during pulmonary tumor resection. We then conducted a randomized, double-blind, dose-escalation study in healthy human volunteers receiving VGT-309 to evaluate safety. Finally, we tested VGT-309 in humans undergoing lung cancer surgery. Results: In preclinical models, we found highly specific tumor cell labeling that was blocked by a broad spectrum cathepsin inhibitor. When evaluating VGT-309 for guidance during resection of canine tumors, we found that the probe selectively labeled tumors and demonstrated high tumor-to-background ratio (TBR; range: 2.15–3.71). In the Phase I human study, we found that VGT-309 was safe at all doses studied. In the ongoing Phase II trial, we report two cases in which VGT-309 localized visually occult, non-palpable tumors (TBRs = 2.83 and 7.18) in real time to illustrate its successful clinical translation and potential to improve surgical management. Conclusions: This first-in-human study demonstrates the safety and feasibility of VGT-309 to label human pulmonary tumors during resection. These results may be generalizable to other cancers due to cathepsin overexpression in many solid tumors.
- 6 July 2022
- Published by American Association for Cancer Research (AACR) in Clinical Cancer Research
- Vol. 28 (17) , 3729-3741
A Cathepsin-Targeted Quenched Activity–Based Probe Facilitates Enhanced Detection of Human Tumors during Resection
Purpose: Fluorescence-guided surgery using tumor-targeted contrast agents has been developed to improve the completeness of oncologic resections. Quenched activity–based probes that fluoresce after covalently binding to tumor-specific enzymes have been proposed to improve specificity, but none have been tested in humans. Here, we report the successful clinical translation of a cathepsin activity–based probe (VGT-309) for fluorescence-guided surgery. Experimental Design: We optimized the specificity, dosing, and timing of VGT-309 in preclinical models of lung cancer. To evaluate clinical feasibility, we conducted a canine study of VGT-309 during pulmonary tumor resection. We then conducted a randomized, double-blind, dose-escalation study in healthy human volunteers receiving VGT-309 to evaluate safety. Finally, we tested VGT-309 in humans undergoing lung cancer surgery. Results: In preclinical models, we found highly specific tumor cell labeling that was blocked by a broad spectrum cathepsin inhibitor. When evaluating VGT-309 for guidance during resection of canine tumors, we found that the probe selectively labeled tumors and demonstrated high tumor-to-background ratio (TBR; range: 2.15–3.71). In the Phase I human study, we found that VGT-309 was safe at all doses studied. In the ongoing Phase II trial, we report two cases in which VGT-309 localized visually occult, non-palpable tumors (TBRs = 2.83 and 7.18) in real time to illustrate its successful clinical translation and potential to improve surgical management. Conclusions: This first-in-human study demonstrates the safety and feasibility of VGT-309 to label human pulmonary tumors during resection. These results may be generalizable to other cancers due to cathepsin overexpression in many solid tumors.