    Concordance of a Laboratory-Data Integrated Fluid Targeting Algorithm with Bioimpedance-Derived Volume Measures in Maintenance Hemodialysis

    by Kazuhiko Shibata, Hiroyoshi Fukui, Tamio Iwamoto, Sanae Saka, Yuki Kawai, Takeshi Aoki, Ryo Shibata, Kanenori Maeda, Hiromichi Wakui, Kouichi Tamura

    Background: Objective fluid assessment in hemodialysis often requires dedicated bioimpedance equipment. The Laboratory-Data Integrated Fluid Targeting algorithm uses routine biochemical and dialysis treatment data to estimate extracellular water, intracellular water, and euvolemic body weight. We evaluated its concordance with the Fresenius Body Composition Monitor and explored determinants of method differences. Methods: In this prospective single-center study, 61 adults receiving stable maintenance hemodialysis for at least 3 months underwent paired assessment during one dialysis session. Agreement was evaluated using Pearson correlation, Deming regression, and Bland–Altman analysis. Exploratory multivariable models were used to examine age, sex, dialysis vintage, diabetes, heart failure, and ischemic heart disease. Clinically prescribed dry weight was analyzed as a separate clinical comparator. Results: Extracellular-water estimates were strongly correlated (correlation coefficient, 0.87). The mean difference between the Laboratory-Data Integrated Fluid Targeting and Body Composition Monitor estimates was +0.22 L, with 95% limits of agreement from −4.1 to +4.6 L. The correlation for intracellular water was lower (correlation coefficient, 0.80), with a mean difference of +2.7 L and limits of agreement from −3.5 to +8.9 L. Estimated euvolemic weight was strongly correlated (correlation coefficient, 1.0 after rounding), although this partly reflected the shared body-weight component (mean difference, −0.67 kg; limits of agreement, −4.0 to +2.6 kg). Older age was associated with a smaller extracellular-water difference, whereas sex, dialysis vintage, diabetes, heart failure, and ischemic heart disease were not independently associated with method differences. Conclusions: The laboratory-based algorithm approximated Body Composition Monitor outputs at the cohort level; however, proportional bias and wide individual limits, particularly for intracellular water, preclude interchangeability. These findings support method concordance but do not constitute independent physiological or outcome validation. Clinical actionability and outcome benefit remain untested.

  • Open Access

    Moist Wound Healing and Eutectic Mixture of Local Anesthetics Cream for Clean Buttonhole Cannulation

    by Kazuhiko Shibata, Shigeki Toma, Shigeru Nakai, Masumi Yamamoto, Kouichi Tamura

    Key Points: In buttonhole cannulation, where scabs are forcibly removed, the infection rate is higher than that in the rope ladder method. The clean buttonhole method enhances scab care by combining moist wound healing, thorough washing, and eutectic mixture of local anesthetics. The buttonhole technique allows patients to maintain healthy skin, except for the two puncture sites. Background: The buttonhole cannulation technique is recognized for its advantages in hemodialysis, including reduced cannulation errors, decreased pain, and prevention of hematoma formation. However, it has been criticized for possibly increasing the risk of local and systemic infections, including sepsis and death. Prior studies have shown the infection risks associated with the buttonhole technique compared with the rope ladder technique, but the role of scab removal methods at the puncture site has been overlooked. The clean buttonhole method was developed on the basis of softening and removing buttonhole scabs with liquid soap in home hemodialysis, incorporating moist wound-healing treatment, thorough washing, and eutectic mixture of local anesthetics cream to efficiently eliminate scabs. Methods: This observational study included patients undergoing maintenance hemodialysis at Toshin Clinic in Yokohama, Japan, from June 2020 to July 2024. Infection rates were documented in both the clean buttonhole and sharp needle groups. Statistical tests were used to compare the incidence of local infections between the groups. Results: Among 33,137 punctures performed using the clean buttonhole technique, only one localized infection was reported, characterized by mild redness without pain. By contrast, the sharp needle group experienced multiple infections with the rope ladder technique. The local infection rate was 0.030 cases per 1000 punctures in the clean buttonhole group compared with 0.025 cases per 1000 punctures in the sharp needle group, with no statistically significant difference observed ( P = 0.86). Conclusions: The clean buttonhole method demonstrates a comparable infection risk profile with traditional sharp needle techniques. These findings indicate that this method may enhance patient safety and comfort in hemodialysis. Further research with larger, multicenter populations is needed to validate these results and assess broader applications in various clinical settings.

  • Open Access

    Novel Capped-Needle Device: A Novel Safety Feature to Eliminate Air Bubbles in Hemodialysis

    by Kazuhiko Shibata, Takahiro Shinzato, Shigeki Toma, Shigeru Nakai, Yusuke Kobayashi, Tatsuo Hashimoto, Koichi Tamura

    Introduction: Air bubbles in the dialysis circuit are rarely visible after automatic priming; however, they are often visible after the needles are manually connected to the circuit. To prevent this issue, we thought to prime needles with a circuit at automatic priming by the hemodialysis machine. In order to achieve this idea, we designed and manufactured a novel capped needle to connect the needles to the extracorporeal circuit before the automatic priming of the hemodialysis machine. This study investigated the effectiveness of this novel capped needle and compared it with the conventional method for preventing air bubble contamination. Methods: We tested novel capped needles ten times to evaluate whether the dialysis machine works appropriately and removes air bubbles even with the attached capped needle. Next, we performed 25 trials using the conventional method, in which skilled nurses manually connect the needle. In both methods, we thoroughly counted the air bubbles with our naked eyes. We predicted that the capped needle would leave few bubbles in the circuit. In order to evaluate fewer bubbles, we conducted an additional experiment using a microparticle counter to measure the size and number of the bubbles. Results: We thoroughly searched for air bubbles during each of the ten tests but could not find any bubbles visible to the naked eye. In the conventional method, bubbles were visible in 29 out of 50 cases. The bubble count was significantly lower in the capped-needle method than in the conventional method (p < 0.0001, Pearson’s χ2 test). In the additional experiments using the microparticle counter, the average remaining air volume in the extracorporeal circuit was 0.0999 ± 0.2438 nL when the priming was performed using the novel capped needles. Conclusion: The novel capped needle eliminated all visible bubbles efficiently and effectively; therefore, it could be a valuable device for hemodialysis treatment. The reduction of air from the dialysis circuit may improve patient prognosis.

  • Comparison of Body Fluid Volumes Determined by Kinetic Modeling and by Bioimpedance Spectroscopy

    by Takeshi Aoki, Shigeru Nakai, Junji Uchino, Kazuhiko Shibata, Takahiro Shinzato, Ikuto Masakane, Shigeki Toma, Hiroyoshi Fukui, Teppei Matsuoka, Shinya Kato, et al.

    Introduction: The bioimpedance spectroscopy (BIS) method is used in individual patients requiring body fluid volume measurement. In a hemodialysis facility, however, regular screening of body fluid volumes is also necessary. Such screening, by kinetic modeling, may become possible by calculating distribution volumes of urea and uric acid from regular blood test results. Objective: The aim is to compare uric acid distribution volumes with BIS-extracellular volume, urea distribution volume with BIS-total body water, and difference between urea and uric acid distribution volumes with BIS-intracellular volume. Methods: We reanalyzed stored blood test data of 53 hemodialysis patients obtained together with BIS data of the same patients in our previous study. Results: Significant correlations were found between urea distribution volume and total body water predicted by the BIS method, between uric acid distribution volume and extracellular volume predicted by the BIS method, and between the difference of uric acid distribution volume from urea distribution volume and intracellular volume predicted by the BIS method. In Bland-Altman analysis, comparison of each pair showed no systematic error. The mean difference between each pair was minimal. Conclusion: Fluid volumes in different body compartments can be estimated by kinetic modeling as well as by the BIS method.