Joshua Anani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joshua Anani has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Hassan El Shazly
Chemical and Petrochemicals Engineering Department, Egypt-Japan University of Science and Technology, Alexandria 21934, Egypt
2 shared publications - Hussien Noby
Chemical and Petrochemicals Engineering, Egypt-Japan University of Science and Technology, Alexandria 21934, Egypt
2 shared publications - Kingsley Safo
Department of Chemical and Petrochemicals Engineering, Egypt-Japan University of Science and Technology, New Borg Al-Arab City 21934, Egypt
2 shared publications - Marwa Elkady
Chemical and Petrochemical Engineering Department, Egypt-Japan University of Science and Technology (E-JUST), New Borg El-Arab City 21934, Egypt
2 shared publications - Abdelrahman Zkria
Department of Applied Science for Electronics and Materials, Kyushu University
1 shared publication - Tsuyoshi Yoshitake
Kyushu University, Fukuoka, Japan
1 shared publication
Latest Publications
- 14 October 2024
- Published by Springer Nature in Journal of Coatings Technology and Research
- Vol. 22 (2) , 675-689
Novel eco-friendly self-healing nanozirconium vanadate@alginate hybrid microcapsules for corrosion prevention
- 14 October 2024
- Published by Springer Nature in Journal of Coatings Technology and Research
- Vol. 22 (2) , 675-689
Novel eco-friendly self-healing nanozirconium vanadate@alginate hybrid microcapsules for corrosion prevention
- Open Access
- 26 September 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 67 (1) , 54
Enhancing Microfluidic Systems’ Mixing Efficiency Using Design Models with Convergent–Divergent Sinusoidal Microchannel Walls: Experimental Investigations Based on Entropy Minimization Flow Structures
This study presents an innovative passive micromixer design featuring convergent–divergent sinusoidal walls, evaluated using the Villermaux–Dushman protocol. Five distinct designs were fabricated and tested, demonstrating superior mixing efficiency without additional obstructions. Testing of flow rates from 1000 to 50 mL/h revealed that the square-wave micromixer had the highest efficiency due to repeated fluid perturbations from its 90-degree angles. The loop-wave mixer performed the worst due to its lack of angles. The circular and box-wave mixers outperformed the loop-wave and backward arrow mixers due to their split and recombination effects. These designs, especially the circular and box-wave designs, offer optimal mixing for short-length applications, improving the efficiency and manufacturing simplicity for biomedical and biochemical analyses.
- 26 September 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 67 (1) , 54
Open AccessEnhancing Microfluidic Systems’ Mixing Efficiency Using Design Models with Convergent–Divergent Sinusoidal Microchannel Walls: Experimental Investigations Based on Entropy Minimization Flow Structures
This study presents an innovative passive micromixer design featuring convergent–divergent sinusoidal walls, evaluated using the Villermaux–Dushman protocol. Five distinct designs were fabricated and tested, demonstrating superior mixing efficiency without additional obstructions. Testing of flow rates from 1000 to 50 mL/h revealed that the square-wave micromixer had the highest efficiency due to repeated fluid perturbations from its 90-degree angles. The loop-wave mixer performed the worst due to its lack of angles. The circular and box-wave mixers outperformed the loop-wave and backward arrow mixers due to their split and recombination effects. These designs, especially the circular and box-wave designs, offer optimal mixing for short-length applications, improving the efficiency and manufacturing simplicity for biomedical and biochemical analyses.
- 1 February 2024
- Published by Walter de Gruyter GmbH in International Journal of Chemical Reactor Engineering
- Vol. 22 (4) , 415-425
Investigations of the mixing efficiency of five novel micromixer designs with backward arrow inlet using the Villermaux Dushman protocol
This study explores and analyzes the mixing efficiency of five innovative micromixers, each featuring serpentine microchannels, through comprehensive experimentation. The mixing experiments were conducted on micromixers with distinct shapes: backward arrow, loop, square, circular, and box waves, all equipped with backward arrow-shaped inlets, using the Villermaux–Dushman protocol. The assessment of mixing performance was carried out across a range of Reynolds numbers (Re) from 100 to 700, accompanied by varying pressure drop measurements. The efficiency of mixing was determined using ultraviolet spectrophotometry to measure the absorbance values and times for mixed fluids from the five micromixers. At Re values greater than 100, the mixing performance ranked as follows: Square-wave > Circular-wave > Box-wave > Loop-wave > Backward Arrow-shaped micromixers. Factors such as repeated perturbations, the presence of crests and troughs, the angle of the channels, and the split and recombination effects played significant roles in these outcomes. With increasing Re from 100 to 700, we observed progressive and consistent results across all microchannels. Remarkably, at a broad range of Reynolds numbers, the five micromixers demonstrated superior mixing performance compared to designs based on unbalanced split and collisions, achieving an impressive mixing efficiency of over 93 %, while keeping the pressure drop under 80 kPa. This pressure drop range is suitable for a variety of lab-on-a-chip and micro-total analysis systems. Furthermore, the experimental results show that the mixing performance of microfluidic systems can be improved by incorporating the presented design method of microchannel shapes, especially the Square-wave.
- 1 February 2024
- Published by Walter de Gruyter GmbH in International Journal of Chemical Reactor Engineering
- Vol. 22 (4) , 415-425
Investigations of the mixing efficiency of five novel micromixer designs with backward arrow inlet using the Villermaux Dushman protocol
This study explores and analyzes the mixing efficiency of five innovative micromixers, each featuring serpentine microchannels, through comprehensive experimentation. The mixing experiments were conducted on micromixers with distinct shapes: backward arrow, loop, square, circular, and box waves, all equipped with backward arrow-shaped inlets, using the Villermaux–Dushman protocol. The assessment of mixing performance was carried out across a range of Reynolds numbers (Re) from 100 to 700, accompanied by varying pressure drop measurements. The efficiency of mixing was determined using ultraviolet spectrophotometry to measure the absorbance values and times for mixed fluids from the five micromixers. At Re values greater than 100, the mixing performance ranked as follows: Square-wave > Circular-wave > Box-wave > Loop-wave > Backward Arrow-shaped micromixers. Factors such as repeated perturbations, the presence of crests and troughs, the angle of the channels, and the split and recombination effects played significant roles in these outcomes. With increasing Re from 100 to 700, we observed progressive and consistent results across all microchannels. Remarkably, at a broad range of Reynolds numbers, the five micromixers demonstrated superior mixing performance compared to designs based on unbalanced split and collisions, achieving an impressive mixing efficiency of over 93 %, while keeping the pressure drop under 80 kPa. This pressure drop range is suitable for a variety of lab-on-a-chip and micro-total analysis systems. Furthermore, the experimental results show that the mixing performance of microfluidic systems can be improved by incorporating the presented design method of microchannel shapes, especially the Square-wave.
- Open Access
Monothetic Analysis and Response Surface Methodology Optimization of Calcium Alginate Microcapsules Characteristics
Owing to bio-polymer’s low-cost, environmental friendliness and mechanically stable nature, calcium alginate microcapsules have attracted much interest for their applications in numerous fields. Among the common production methods, the Electrospraying technique has shown a great potential due to smaller shape capsule production and ease of control of independent affecting parameters. Although one factor at a time (OFAT) can predict the trends of parameter effect on size and sphericity, it is inefficient in explaining the complex parameter interaction of the electrospray process. In the current study, the effects of the main parameters affecting on size and sphericity of the microcapsules using OFAT were optimized to attain calcium alginate microcapsules with an average diameter below 100 µm. Furthermore, we propose a statistical model employing the Surface Responses Methodology (RSM) and Central Composite Design (CDD) to generate a quadratic order linear regression model for the microcapsule diameter and sphericity coefficient. Experimentally, microcapsules with a size of 92.586 µm and sphericity coefficient of 0.771 were predicted and obtained from an alginate concentration of 2.013 w/v, with a flowrate of 0.560 mL/h, a needle size of 27 G and a 2.024 w/v calcium chloride concentration as optimum parameters. The optimization processes were successfully aligned towards formation of the spherical microcapsules with smaller average diameter of less than 100 µm, owing to the applied high voltage that reached up to 21 kV.
Open AccessMonothetic Analysis and Response Surface Methodology Optimization of Calcium Alginate Microcapsules Characteristics
Owing to bio-polymer’s low-cost, environmental friendliness and mechanically stable nature, calcium alginate microcapsules have attracted much interest for their applications in numerous fields. Among the common production methods, the Electrospraying technique has shown a great potential due to smaller shape capsule production and ease of control of independent affecting parameters. Although one factor at a time (OFAT) can predict the trends of parameter effect on size and sphericity, it is inefficient in explaining the complex parameter interaction of the electrospray process. In the current study, the effects of the main parameters affecting on size and sphericity of the microcapsules using OFAT were optimized to attain calcium alginate microcapsules with an average diameter below 100 µm. Furthermore, we propose a statistical model employing the Surface Responses Methodology (RSM) and Central Composite Design (CDD) to generate a quadratic order linear regression model for the microcapsule diameter and sphericity coefficient. Experimentally, microcapsules with a size of 92.586 µm and sphericity coefficient of 0.771 were predicted and obtained from an alginate concentration of 2.013 w/v, with a flowrate of 0.560 mL/h, a needle size of 27 G and a 2.024 w/v calcium chloride concentration as optimum parameters. The optimization processes were successfully aligned towards formation of the spherical microcapsules with smaller average diameter of less than 100 µm, owing to the applied high voltage that reached up to 21 kV.