DSDimitrios Stoupis

Dimitrios Stoupis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dimitrios Stoupis has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Anatomy-informed recommendations for electrode montage and shape in electrical stimulation methods: a tDCS case study

    by Dimitrios Stoupis, Sara Assecondi

    Objective. Transcranial direct current stimulation (tDCS) shows potential for cognitive enhancement and neuromodulation, yet its efficacy is limited by substantial inter-individual variability in the induced electric field ( E -field) distribution in targeting brain areas and functional networks. This study aims to develop an anatomy-informed framework to select electrode montage and geometry that optimizes network-level E -field delivery. Approach. Using high-resolution T1-weighted/T2-weighted MRI from 590 participants (ages 36–80) in the Human Connectome Project-Aging, we extracted anatomical features, including cortical, skull, and cerebrospinal fluid (CSF) thickness, and sulcal depth. We simulated E -fields with finite-element models (SimNIBS 4.1) across multiple commonly used montages in working memory research. Network-level analyses, based on the Schaefer atlas, were performed to assess the spatial distribution and intensity of tDCS-induced E -fields. Main results. Montage configuration and individual anatomy strongly shape the spatial distribution and intensity of tDCS-induced E -fields. For montages targeting the dorsolateral prefrontal cortex, the resulting fields extended beyond the intended site and exhibited considerable variability in their cortical focality and magnitude. Principal component and feature importance analyses indicated local gyrification index, cortical thickness, skull thickness, CSF thickness, and sulcal depth as primary determinants of network-level E -field distribution, with executive and default mode networks most consistently receiving suprathreshold E -field magnitudes. Importantly, peak induced E -field varied markedly between individuals even under standardized protocols, highlighting substantial inter-individual variability in both dosing and targeting outcomes. Significance. We present a practical workflow for anatomy-guided montage selection that addresses the need for personalized approaches in tDCS. This framework has the potential to improve the efficacy and reproducibility of tDCS in both research and clinical practice by accounting for individual anatomical differences in stimulation planning.


  • Open Access

    The On-Board Computer of the AcubeSAT Mission

    by Konstantinos Tsoupos, Stylianos Tzelepis, Georgios Sklavenitis, Dimitrios Stoupis, Grigorios Pavlakis, Panagiotis Bountzioukas, Christina Athanasiadou, Lily Ha, David Palma, Loris Franchi, et al.

    AcubeSAT is an open-source CubeSat mission aiming to explore the effects of microgravity and radiation on eukaryotic cells using a compact microfluidic lab-on-a-chip platform. It is developed by SpaceDot, a volunteer, interdisciplinary student team at the Aristotle University of Thessaloniki and supported by the "Fly Your Satellite! 3" program of the European Space Agency (ESA) Education Office. The nanosatellite features an in-house designed on-board computer subsystem responsible for telecommand execution, telemetry fetching, onboard time synchronization, in-orbit patching, and fault recovery. The subsystem is designed on one PC/104 standard compatible Printed Circuit Board (PCB) that hosts the On-board Computer (OBC) on the one side and the Attitude and Orbit Control Subsystem (AOCS) on the other, and it is compatible with the LibreCube standard. The hosted subsystems are functionally isolated and feature an ARM Cortex-M7, radiation-tolerant microcontroller each. Before sending anything to space thorough testing is required and specifically the on-board computer board underwent vibration and thermal cycling tests to ensure nominal operation in all conditions. This paper aims to elucidate the decision-making process, design iterations, and development stages of the custom board and accompanying in-house software. Insights garnered from the initial partially successful environmental test campaign at the ESA CubeSat Support Facility will be shared, along with the ensuing preparations, results, and lessons learned from subsequent testing endeavors in April 2024. Furthermore, the current developmental status will be discussed alongside future electromagnetic compatibility testing, integration plan on a FlatSat, and prospects for the open-source design as a cost-effective, and modular solution that can be tailored with little effort for upcoming missions.

  • Open Access

    The Evolution from Design to Verification of the Antenna System and Mechanisms in the AcubeSAT mission

    by Panagiotis Bountzioukas, Georgios Kikas, Christoforos Tsiolakis, Dimitrios Stoupis, Eleftheria Chatziargyriou, Alkis Hatzopoulos, Vasiliki Kourampa-Gottfroh, Ilektra Karakosta-Amarantidou, Aggelos Mavropoulos, Ioannis-Nikolaos Komis, et al.

    AcubeSAT is an open-source CubeSat mission aiming to explore the effects of microgravity and radiation on eukaryotic cells using a compact microfluidic LoC platform. It is developed by SpaceDot, a volunteer, interdisciplinary student team at the Aristotle University of Thessaloniki and supported by the "Fly Your Satellite! 3" program of the ESA Education Office. The scientific data of the mission is comprised of microscope images captured through the on-board integrated camera setup. As the total size of the payload data is expected to be close to 2GB over 12 months, a fast and efficient downlink fulfilling the restrictive power, cost and complexity budgets is required. Currently, there is no open-source communications system design which fully supports these specific constraints, so we opted to develop our own solutions. The antenna system underwent multiple iterations as the design matured, a process highly aided by the feedback received from the ESA experts. The final communications system configuration consists of an S-band microstrip antenna operating at 2.4GHz and a UHF deployable antenna, for the payload data and TM&TC respectively, both in-house designed. In this paper, we will present AcubeSAT's antenna system iterations that span over 3 years, as well as the rationale and analysis results behind each. The development decisions will be highlighted throughout the paper in an effort to aid in the future development of such a low-cost CubeSat mission communications system.

  • Open Access

    Non-invasive stimulation with temporal interference: optimization of the electric field deep in the brain with the use of a genetic algorithm

    by D Stoupis, T Samaras

    Objective. Since the introduction of transcranial temporal interference stimulation, there has been an ever-growing interest in this novel method, as it theoretically allows non-invasive stimulation of deep brain target regions. To date, attempts have been made to optimize the electrode montages and injected current to achieve personalized area targeting using two electrode pairs. Most of these methods use exhaustive search to find the best match, but faster and, at the same time, reliable solutions are required. In this study, the electrode combinations as well as the injected current for a two-electrode pair stimulation were optimized using a genetic algorithm, considering the right hippocampus as the region of interest (ROI). Approach. Simulations were performed on head models from the Population Head Model repository. First, each model was fitted with an electrode array based on the 10–10 international EEG electrode placement system. Following electrode placement, the models were meshed and solved for all single-pair electrode combinations, using an electrode on the left mastoid as a reference (ground). At the optimization stage, different electrode pairs and injection currents were tested using a genetic algorithm to obtain the optimal combination for each model, by setting three different maximum electric field thresholds (0.2, 0.5, and 0.8 V m−1) in the ROI. The combinations below the set threshold were given a high penalty. Main results. Greater focality was achieved with our optimization, specifically in the ROI, with a significant decrease in the surrounding electric field intensity. In the non-optimized case, the mean brain volumes stimulated above 0.2 V m−1 were 99.9% in the ROI, and 76.4% in the rest of the gray matter. In contrast, the stimulated mean volumes were 91.4% and 29.6%, respectively, for the best optimization case with a threshold of 0.8 V m−1. Additionally, the maximum electric field intensity inside the ROI was consistently higher than that outside of the ROI for all optimized cases. Objective. Given that the accomplishment of a globally optimal solution requires a brute-force approach, the use of a genetic algorithm can significantly decrease the optimization time, while achieving personalized deep brain stimulation. The results of this work can be used to facilitate further studies that are more clinically oriented; thus, enabling faster and at the same time accurate treatment planning for the stimulation sessions.


  • Open Access

    Non-invasive stimulation with Temporal Interference: Optimization of the electric field deep in the brain with the use of a genetic algorithm

    by D. Stoupis, T. Samaras

    Objective Since the introduction of transcranial temporal interference stimulation (tTIS), there has been an ever-growing interest in this novel method, as it theoretically allows non-invasive stimulation of deep brain target regions. To date, attempts have been made to optimize the electrode montages and injected current to achieve personalized area targeting using two electrode pairs. Most of these methods use exhaustive search to find the best match, but faster and, at the same time, reliable solutions are required. In this study, the aforementioned stimulation settings were optimized using a genetic algorithm. Methods Simulations were performed on head models from the Population Head Model (PHM) repository. First, each model was fitted with an electrode array based on the 10-10 international EEG electrode placement system. Following electrode placement, the models were meshed and solved for all single-pair electrode combinations using an electrode on the left mastoid as a reference (ground). At the optimization stage, different electrode pairs and injection currents were tested using a genetic algorithm to obtain the optimal combination for each model. Results Greater focality was achieved with optimization, specifically for the right hippocampus (region of interest), with a significant decrease in the surrounding electric field intensity. In the non-optimized case, the brain volumes stimulated above 0.2V/m were 99.9% in the region of interest (ROI), and 76.4% in the rest of the gray matter. In contrast, the stimulated volumes were 91.4% and 29.6% for the best optimization case. Additionally, the maximum electric field intensity inside the region of interest was consistently higher than that outside the ROI for all optimized cases. Significance Given that the accomplishment of a globally optimal solution requires a brute-force approach, the use of a genetic algorithm can significantly decrease the optimization time and provide usable results. Although the method is promising and the indications are becoming more robust, such that optimal solutions can be achieved at the individual level, there are limitations on what can be achieved using only two electrode pairs.