Xiaocheng Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Xiaocheng Guo has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Chunyong Yang
Hubei Key Laboratory of Intelligent Wireless Communications, Hubei Engineering Research Center of Intelligent IOT Technology, College of Electronics and Information Engineering, South-Central Minzu University, Wuhan, China
1 shared publication - Hao Long
Department of Mechanical Engineering, Zhonghuan Information College Tianjin University of Technology, Tianjin, China
1 shared publication Haoning Wang
Hubei Key Laboratory of Intelligent Wireless Communications, College of Electronic and Information Engineering, South-Central University for Nationalities, Wuhan, China
1 shared publicationHong Tao
Foshan (Southern China) Institute for New Materials, Foshan, China
1 shared publication- Jin Hou
South-Central Minzu University
1 shared publication - Jing Yang
Huazhong University of Science and Technology, Wuhan, China
1 shared publication
Latest Publications
- 27 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 34 (4) , 211-214
(Mg)ZnO Photoconductive Detector Development for Direct-Conversion Hard X-Ray Detection
Wide-bandgap semiconductor-based X-ray detectors provide a number of advantages. As presented in this letter, (Mg)ZnO photoconductive direct-conversion X-ray detectors with various Mg contents were fabricated and demonstrated. The signal-to-noise ratio (SNR) and response time of the devices under 6 MV hard X-ray irradiation were significantly improved after doping with Mg. The Ag-Mg 0.19 Zn 0.81 O-Ag photoconductive detector with optimal Mg contents exhibited a sensitivity of 3.03 $\mu \text{C}$ /(mGy $_{\mathrm {air}}\cdot $ cm 3 ), a short response time of approximately 0.2 s (rise time) and 0.3 s (decay time), and a large SNR of 278 with a bias of 30 V under hard X-ray irradiation (100 mGy air /s). The results indicate great application prospects for wide-bandgap MgZnO in direct-conversion X-ray detectors.
- 27 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 34 (4) , 211-214
(Mg)ZnO Photoconductive Detector Development for Direct-Conversion Hard X-Ray Detection
Wide-bandgap semiconductor-based X-ray detectors provide a number of advantages. As presented in this letter, (Mg)ZnO photoconductive direct-conversion X-ray detectors with various Mg contents were fabricated and demonstrated. The signal-to-noise ratio (SNR) and response time of the devices under 6 MV hard X-ray irradiation were significantly improved after doping with Mg. The Ag-Mg 0.19 Zn 0.81 O-Ag photoconductive detector with optimal Mg contents exhibited a sensitivity of 3.03 $\mu \text{C}$ /(mGy $_{\mathrm {air}}\cdot $ cm 3 ), a short response time of approximately 0.2 s (rise time) and 0.3 s (decay time), and a large SNR of 278 with a bias of 30 V under hard X-ray irradiation (100 mGy air /s). The results indicate great application prospects for wide-bandgap MgZnO in direct-conversion X-ray detectors.